962 resultados para Magnetic size effects
Resumo:
For their survival, humans and animals can rely on motivational systems which are specialized in assessing the valence and imminence of dangers and appetitive cues. The Orienting Response (OR) is a fundamental response pattern that an organism executes whenever a novel or significant stimulus is detected, and has been shown to be consistently modulated by the affective value of a stimulus. However, detecting threatening stimuli and appetitive affordances while they are far away compared to when they are within reach constitutes an obvious evolutionary advantage. Building on the linear relationship between stimulus distance and retinal size, the present research was aimed at investigating the extent to which emotional modulation of distinct processes (action preparation, attentional capture, and subjective emotional state) is affected when reducing the retinal size of a picture. Studies 1-3 examined the effects of picture size on emotional response. Subjective feeling of engagement, as well as sympathetic activation, were modulated by picture size, suggesting that action preparation and subjective experience reflect the combined effects of detecting an arousing stimulus and assessing its imminence. On the other hand, physiological responses which are thought to reflect the amount of attentional resources invested in stimulus processing did not vary with picture size. Studies 4-6 were conducted to substantiate and extend the results of studies 1-3. In particular, it was noted that a decrease in picture size is associated with a loss in the low spatial frequencies of a picture, which might confound the interpretation of the results of studies 1-3. Therefore, emotional and neutral images which were either low-pass filtered or reduced in size were presented, and affective responses were measured. Most effects which were observed when manipulating image size were replicated by blurring pictures. However, pictures depicting highly arousing unpleasant contents were associated with a more pronounced decrease in affective modulation when pictures were reduced in size compared to when they were blurred. The present results provide important information for the study of processes involved in picture perception and in the genesis and expression of an emotional response. In particular, the availability of high spatial frequencies might affect the degree of activation of an internal representation of an affectively charged scene, and might modulate subjective emotional state and preparation for action. Moreover, the manipulation of stimulus imminence revealed important effects of stimulus engagement on specific components of the emotional response, and the implications of the present data for some models of emotions have been discussed. In particular, within the framework of a staged model of emotional response, the tactic and strategic role of response preparation and attention allocation to stimuli varying in engaging power has been discussed, considering the adaptive advantages that each might represent in an evolutionary view. Finally, the identification of perceptual parameters that allow affective processing to be carried out has important methodological applications in future studies examining emotional response in basic research or clinical contexts.
Resumo:
Magnetic resonance imaging (MRI) is today precluded to patients bearing active implantable medical devices AIMDs). The great advantages related to this diagnostic modality, together with the increasing number of people benefiting from implantable devices, in particular pacemakers(PM)and carioverter/defibrillators (ICD), is prompting the scientific community the study the possibility to extend MRI also to implanted patients. The MRI induced specific absorption rate (SAR) and the consequent heating of biological tissues is one of the major concerns that makes patients bearing metallic structures contraindicated for MRI scans. To date, both in-vivo and in-vitro studies have demonstrated the potentially dangerous temperature increase caused by the radiofrequency (RF) field generated during MRI procedures in the tissues surrounding thin metallic implants. On the other side, the technical evolution of MRI scanners and of AIMDs together with published data on the lack of adverse events have reopened the interest in this field and suggest that, under given conditions, MRI can be safely performed also in implanted patients. With a better understanding of the hazards of performing MRI scans on implanted patients as well as the development of MRI safe devices, we may soon enter an era where the ability of this imaging modality may be more widely used to assist in the appropriate diagnosis of patients with devices. In this study both experimental measures and numerical analysis were performed. Aim of the study is to systematically investigate the effects of the MRI RF filed on implantable devices and to identify the elements that play a major role in the induced heating. Furthermore, we aimed at developing a realistic numerical model able to simulate the interactions between an RF coil for MRI and biological tissues implanted with a PM, and to predict the induced SAR as a function of the particular path of the PM lead. The methods developed and validated during the PhD program led to the design of an experimental framework for the accurate measure of PM lead heating induced by MRI systems. In addition, numerical models based on Finite-Differences Time-Domain (FDTD) simulations were validated to obtain a general tool for investigating the large number of parameters and factors involved in this complex phenomenon. The results obtained demonstrated that the MRI induced heating on metallic implants is a real risk that represents a contraindication in extending MRI scans also to patient bearing a PM, an ICD, or other thin metallic objects. On the other side, both experimental data and numerical results show that, under particular conditions, MRI procedures might be consider reasonably safe also for an implanted patient. The complexity and the large number of variables involved, make difficult to define a unique set of such conditions: when the benefits of a MRI investigation cannot be obtained using other imaging techniques, the possibility to perform the scan should not be immediately excluded, but some considerations are always needed.
Resumo:
The past decade has seen significant increases in combustion-generated ambient particles, which contain a nanosized fraction (less than 100 nm), and even greater increases have occurred in engineered nanoparticles (NPs) propelled by the booming nanotechnology industry. Although inhalation of these particulates has become a public health concern, human health effects and mechanisms of action for NPs are not well understood. Focusing on the human airway smooth muscle cell, here we show that the cellular mechanical function is altered by particulate exposure in a manner that is dependent upon particle material, size and dose. We used Alamar Blue assay to measure cell viability and optical magnetic twisting cytometry to measure cell stiffness and agonist-induced contractility. The eight particle species fell into four categories, based on their respective effect on cell viability and on mechanical function. Cell viability was impaired and cell contractility was decreased by (i) zinc oxide (40-100 nm and less than 44 microm) and copper(II) oxide (less than 50 nm); cell contractility was decreased by (ii) fluorescent polystyrene spheres (40 nm), increased by (iii) welding fumes and unchanged by (iv) diesel exhaust particles, titanium dioxide (25 nm) and copper(II) oxide (less than 5 microm), although in none of these cases was cell viability impaired. Treatment with hydrogen peroxide up to 500 microM did not alter viability or cell mechanics, suggesting that the particle effects are unlikely to be mediated by particle-generated reactive oxygen species. Our results highlight the susceptibility of cellular mechanical function to particulate exposures and suggest that direct exposure of the airway smooth muscle cells to particulates may initiate or aggravate respiratory diseases.
Resumo:
The purpose of the study was to quantify and compare the effect of CT dose and of size and density of nodules on the detectability of lung nodules and to quantify the influence of CT dose on the size of the nodules.
Resumo:
Triggered event-related functional magnetic resonance imaging requires sparse intervals of temporally resolved functional data acquisitions, whose initiation corresponds to the occurrence of an event, typically an epileptic spike in the electroencephalographic trace. However, conventional fMRI time series are greatly affected by non-steady-state magnetization effects, which obscure initial blood oxygen level-dependent (BOLD) signals. Here, conventional echo-planar imaging and a post-processing solution based on principal component analysis were employed to remove the dominant eigenimages of the time series, to filter out the global signal changes induced by magnetization decay and to recover BOLD signals starting with the first functional volume. This approach was compared with a physical solution using radiofrequency preparation, which nullifies magnetization effects. As an application of the method, the detectability of the initial transient BOLD response in the auditory cortex, which is elicited by the onset of acoustic scanner noise, was used to demonstrate that post-processing-based removal of magnetization effects allows to detect brain activity patterns identical with those obtained using the radiofrequency preparation. Using the auditory responses as an ideal experimental model of triggered brain activity, our results suggest that reducing the initial magnetization effects by removing a few principal components from fMRI data may be potentially useful in the analysis of triggered event-related echo-planar time series. The implications of this study are discussed with special caution to remaining technical limitations and the additional neurophysiological issues of the triggered acquisition.
Resumo:
To assess the effects of pioglitazone and rosiglitazone on fasting and postprandial low-density lipoprotein (LDL) size and subclasses in patients with Type 2 diabetes.
Resumo:
1H-magnetic resonance spectroscopy ((1)H-MRS) of deoxymyoglobin (DMb) provides a means to noninvasively monitor the oxygenation state of human skeletal muscle in work and disease. As shown in this work, it also offers the opportunity to measure the absolute tissue content of DMb, the basic oxygen consumption of resting muscle, and the reperfusion characteristics after release of a pressure cuff. The methodology to determine these tissue properties simultaneously at two positions along the calf is presented. The obtained values are in agreement with invasive determinations. The reproducibility of the (1)H-MRS measurements is established for healthy controls and patients with peripheral arterial disease (PAD). A location dependence in axial direction, as well as differences between controls and patients are demonstrated for all parameters. The reoxygenation time in particular is expected to provide a means to quantitatively monitor therapies aimed at improving muscular perfusion in these patients.
Resumo:
Reproductive skew theory seeks to integrate social and ecological factors thought to influence the division of reproduction among group-living animals. However, most reproductive skew models only examine interactions between individuals of the same sex. Here, we suggest that females can influence group stability and conflict among males by modifying their clutch size and may do so if they benefit from the presence of subordinate male helpers or from reduced conflict. We develop 3 models, based on concessions-based, restraint, and tug-of-war models, in which female clutch size is variable and ask when females will increase their clutch size above that which would be optimal in the absence of male-male conflict. In concessions-based and restraint models, females should increase clutch size above their optima if the benefits of staying for subordinate males are relatively low. Relatedness between males has no effect on clutch size. When females do increase clutch size, the division of reproduction between males is not influenced by relatedness and does not differ between restraint and concessions-based models. Both of these predictions are in sharp contrast to previous models. In tug-of-war models, clutch size is strongly influenced by relatedness between males, with the largest clutches, but the fewest surviving offspring, produced when males are unrelated. These 3 models demonstrate the importance of considering third-party interests in the decisions of group-living organisms.
Resumo:
Yearling steers were sorted into four groups based on hip height and fat cover at the start of the finishing period. Each group of sorted steers was fed diets containing 0.59 or 0.64 Mcal NEg per pound of diet. The value of each carcass was determined by use of the Oklahoma State University Boxed Beef Calculator. Sorting to increase hip height decreased the percentage of Choice carcasses and fat cover, increased ribeye area, and had no effect on carcass weight or yield grades 1 and 2. Sorting to decrease initial fat cover decreased carcass weight, carcass fat cover, and percentage of choice carcasses and increased the proportion of yield grades 1 and 2 carcasses. Concentration of energy in the finishing diet had no effect on carcass measurements. Increasing the percentage of yield grades 1 and 2 carcasses did not result in increased economic value of the carcasses when quality grades were lower and when there was a wide spread between Choice and Select carcasses, as occurred in 1996. With less spread between Choice and Select, as in 1997, sorting the cattle to increase yield grades 1 and 2 resulted in increased value, especially for close-trim boxed beef. The results of this study emphasize the importance of knowing how carcasses will grade before selecting a valuebased market for selling cattle.