973 resultados para MR PERFUSION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the utility of inversion recovery with ON-resonant water suppression (IRON) to create positive signal in normal lymph nodes after injection of superparamagnetic nanoparticles. MATERIALS AND METHODS: Experiments were conducted on six rabbits, which received a single bolus injection of 80 mumol Fe/kg monocrystalline iron oxide nanoparticle (MION-47). Magnetic resonance imaging (MRI) was performed at baseline, 1 day, and 3 days after MION-47 injection using conventional T(1)- and T(2)*-weighted sequences and IRON. Contrast-to-noise ratios (CNR) were measured in blood and in paraaortic lymph nodes. RESULTS: On T(2)*-weighted images, as expected, signal attenuation was observed in areas of paraaortic lymph nodes after MION-47 injection. However, using IRON the paraaortic lymph nodes exhibited very high contrast enhancement, which remained 3 days after injection. CNR with IRON was 2.2 +/- 0.8 at baseline, increased markedly 1 day after injection (23.5 +/- 5.4, P < 0.01 vs. baseline), and remained high after 3 days (21.8 +/- 5.7, *P < 0.01 vs. baseline). CNR was also high in blood 1 day after injection (42.7 +/- 7.2 vs. 1.8 +/- 0.7 at baseline, P < 0.01) but approached baseline after 3 days (1.9 +/- 1.4, P = NS vs. baseline). CONCLUSION: IRON in conjunction with superparamagnetic nanoparticles can be used to perform 'positive contrast' MR-lymphography, particularly 3 days after injection of the contrast agent, when signal is no longer visible within blood vessels. The proposed method may have potential as an adjunct for nodal staging in cancer screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To investigate the effect of chronic hyperglycemia on cerebral microvascular remodeling using perfusion computed tomography. METHODS: We retrospectively identified 26 patients from our registry of 2453 patients who underwent a perfusion computed tomographic study and had their hemoglobin A1c (HbA1c) measured. These 26 patients were divided into 2 groups: those with HbA1c>6.5% (n=15) and those with HbA1c≤6.5% (n=11). Perfusion computed tomographic studies were processed using a delay-corrected, deconvolution-based software. Perfusion computed tomographic values were compared between the 2 patient groups, including mean transit time, which relates to the cerebral capillary architecture and length. RESULTS: Mean transit time values in the nonischemic cerebral hemisphere were significantly longer in the patients with HbA1c>6.5% (P=0.033), especially in the white matter (P=0.005). Significant correlation (R=0.469; P=0.016) between mean transit time and HbA1c level was observed. CONCLUSIONS: Our results from a small sample suggest that chronic hyperglycemia may be associated with cerebral microvascular remodeling in humans. Additional prospective studies with larger sample size are required to confirm this observation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Diaphragmatic navigators are frequently used in free-breathing coronary MR angiography, either to gate or prospectively correct slice position or both. For such approaches, a constant relationship between coronary and diaphragmatic displacement throughout the respiratory cycle is assumed. The purpose of this study was to evaluate the relationship between diaphragmatic and coronary artery motion during free breathing. SUBJECTS AND METHODS: A real-time echoplanar MR imaging sequence was used in 12 healthy volunteers to obtain 30 successive images each (one per cardiac cycle) that included the left main coronary artery and the domes of both hemidiaphragms. The coronary artery and diaphragm positions (relative to isocenter) were determined and analyzed for effective diaphragmatic gating windows of 3, 5, and 7 mm (diaphragmatic excursions of 0-3, 0-5, and 0-7 mm from the end-expiratory position, respectively). RESULTS: Although the mean slope correlating the displacement of the right diaphragm and the left main coronary artery was approximately 0.6 for all diaphragmatic gating windows, we also found great variability among individual volunteers. Linear regression slopes varied from 0.17 to 0.93, and r2 values varied from .04 to .87. CONCLUSION: Wide individual variability exists in the relationship between coronary and diaphragmatic respiratory motion during free breathing. Accordingly, coronary MR angiographic approaches that use diaphragmatic navigator position for prospective slice correction may benefit from patient-specific correction factors. Alternatively, coronary MR angiography may benefit from a more direct assessment of the respiratory displacement of the heart and coronary arteries, using left ventricular navigators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An autoregulation-oriented strategy has been proposed to guide neurocritical therapy toward the optimal cerebral perfusion pressure (CPPOPT). The influence of ventilation changes is, however, unclear. We sought to find out whether short-term moderate hypocapnia (HC) shifts the CPPOPT or affects its detection. Thirty patients with traumatic brain injury (TBI), who required sedation and mechanical ventilation, were studied during 20 min of normocapnia (5.1±0.4 kPa) and 30 min of moderate HC (4.4±3.0 kPa). Monitoring included bilateral transcranial Doppler of the middle cerebral arteries (MCA), invasive arterial blood pressure (ABP), and intracranial pressure (ICP). Mx -autoregulatory index provided a measure for the CPP responsiveness of MCA flow velocity. CPPOPT was assessed as the CPP at which autoregulation (Mx) was working with the maximal efficiency. During normocapnia, CPPOPT (left: 80.65±6.18; right: 79.11±5.84 mm Hg) was detectable in 12 of 30 patients. Moderate HC did not shift this CPPOPT but enabled its detection in another 17 patients (CPPOPT left: 83.94±14.82; right: 85.28±14.73 mm Hg). The detection of CPPOPT was achieved via significantly improved Mx-autoregulatory index and an increase of CPP mean. It appeared that short-term moderate HC augmented the detection of an optimum CPP, and may therefore usefully support CPP-guided therapy in patients with TBI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combination of cardiac viability and functional information enhances the identification of different heart tissues in the setting of ischemic heart disease. A method has recently been proposed for obtaining black-blood delayed-enhancement (DE) viability images using the stimulated-echo acquisition mode (STEAM) MRI pulse sequence in a single short breathhold. The method was validated against conventional inversion-recovery (IR) DE images for identifying regions of myocardial infarction (MI). The method was based on the acquisition of three consecutive images of the same anatomical slice. One image has T(1)-weighted contrast in which infarction appears bright. The two other images are used to construct an anatomical image of the heart, which is combined with the first image to produce a black-blood viability image. However, using appropriate modulation and demodulation frequencies, the latter two images bear useful information about myocardial deformation that results in a cardiac strain-encoding (SENC) functional image. In this work, a method is proposed for obtaining three consecutive SENC images in a single acquisition that can be combined to produce a composite image of the heart, which shows both functional and viability information. The proposed technique reduces scan time by one-half, compared with separate acquisitions of functional and viability images, and alleviates misregistration problems caused by separate breathholds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effect of a real-time adaptive trigger delay on image quality to correct for heart rate variability in 3D whole-heart coronary MR angiography (MRA). MATERIALS AND METHODS: Twelve healthy adults underwent 3D whole-heart coronary MRA with and without the use of an adaptive trigger delay. The moment of minimal coronary artery motion was visually determined on a high temporal resolution MRI. Throughout the scan performed without adaptive trigger delay, trigger delay was kept constant, whereas during the scan performed with adaptive trigger delay, trigger delay was continuously updated after each RR-interval using physiological modeling. Signal-to-noise, contrast-to-noise, vessel length, vessel sharpness, and subjective image quality were compared in a blinded manner. RESULTS: Vessel sharpness improved significantly for the middle segment of the right coronary artery (RCA) with the use of the adaptive trigger delay (52.3 +/- 7.1% versus 48.9 +/- 7.9%, P = 0.026). Subjective image quality was significantly better in the middle segments of the RCA and left anterior descending artery (LAD) when the scan was performed with adaptive trigger delay compared to constant trigger delay. CONCLUSION: Our results demonstrate that the use of an adaptive trigger delay to correct for heart rate variability improves image quality mainly in the middle segments of the RCA and LAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To develop and assess the diagnostic performance of a three-dimensional (3D) whole-body T1-weighted magnetic resonance (MR) imaging pulse sequence at 3.0 T for bone and node staging in patients with prostate cancer. MATERIALS AND METHODS This prospective study was approved by the institutional ethics committee; informed consent was obtained from all patients. Thirty patients with prostate cancer at high risk for metastases underwent whole-body 3D T1-weighted imaging in addition to the routine MR imaging protocol for node and/or bone metastasis screening, which included coronal two-dimensional (2D) whole-body T1-weighted MR imaging, sagittal proton-density fat-saturated (PDFS) imaging of the spine, and whole-body diffusion-weighted MR imaging. Two observers read the 2D and 3D images separately in a blinded manner for bone and node screening. Images were read in random order. The consensus review of MR images and the findings at prospective clinical and MR imaging follow-up at 6 months were used as the standard of reference. The interobserver agreement and diagnostic performance of each sequence were assessed on per-patient and per-lesion bases. RESULTS: The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significantly higher with whole-body 3D T1-weighted imaging than with whole-body 2D T1-weighted imaging regardless of the reference region (bone or fat) and lesion location (bone or node) (P < .003 for all). For node metastasis, diagnostic performance (area under the receiver operating characteristic curve) was higher for whole-body 3D T1-weighted imaging (per-patient analysis; observer 1: P < .001 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P = .006 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging; observer 2: P = .006 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P = .006 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging), as was sensitivity (per-lesion analysis; observer 1: P < .001 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P < .001 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging; observer 2: P < .001 for 2D T1-weighted imaging vs 3D T1-weighted imaging, P < .001 for 2D T1-weighted imaging + PDFS imaging vs 3D T1-weighted imaging). CONCLUSION: Whole-body MR imaging is feasible with a 3D T1-weighted sequence and provides better SNR and CNR compared with 2D sequences, with a diagnostic performance that is as good or better for the detection of bone metastases and better for the detection of lymph node metastases.