988 resultados para MICRO-CT IMAGING


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Although several approaches have been already used to reduce radiation dose, CT doses are still among the high doses in radio-diagnostic. Recently, General Electric introduced a new imaging reconstruction technique, adaptive statistical iterative reconstruction (ASIR), allows to taking into account the statistical fluctuation of noise. The benefits of ASIR method were assessed through classic metrics and the evaluations of cardiac structures by radiologists. Methods and materials: A 64-row CT (MDCT) was employed. Catphan600 phantom acquisitions and 10 routine-dose CT examinations performed at 80 kVp were reconstructed with FBP and with 50% of ASIR. Six radiologists then assessed the visibility of main cardiac structures using the visual grading analysis (VGA) method. Results: On phantoms, for a constant value of SD (25 HU), CTDIvol is divided by 2 (8 mGy to 4 mGy) when 50% of ASIR is used. At constant CTDIvol, MTF medium frequencies were also significantly improved. First results indicated that clinical images reconstructed with ASIR had a better overall image quality compared with conventional reconstruction. This means that at constant image quality the radiation dose can be strongly reduced. Conclusion: The first results of this study shown that the ASIR method improves the image quality on phantoms by decreasing noise and improving resolution with respect to the classical one. Moreover, the benefit obtained is higher at lower doses. In clinical environment, a dose reduction can still be expected on 80 kVp low dose pediatric protocols using 50% of iterative reconstruction. Best ASIR percentage as a function of cardiac structures and detailed protocols will be presented for cardiac examinations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Patients with symptoms of semicircular canal dehiscence often undergo both CT and MR imaging. We assessed whether FIESTA can replace temporal bone CT in evaluating patients for SC dehiscence. MATERIALS AND METHODS: We retrospectively reviewed 112 consecutive patients (224 ears) with vestibulocochlear symptoms who underwent concurrent MR imaging and CT of the temporal bones between 2007 and 2009. MR imaging protocol included a FIESTA sequence covering the temporal bone (axial 0.8-mm section thickness, 0.4-mm spacing, coronal/oblique reformations; 41 patients at 1.5T, 71 patients at 3T). CT was performed on a 64-row multidetector row scanner (0.625-mm axial acquisition, with coronal/oblique reformations). Both ears of each patient were evaluated for dehiscence of the superior and posterior semicircular canals in consensual fashion by 2 neuroradiologists. Analysis of the FIESTA sequence and reformations was performed first for the MR imaging evaluation. CT evaluation was performed at least 2 weeks after the MR imaging review, resulting in a blinded comparison of CT with MR imaging. CT was used as the reference standard to evaluate the MR imaging results. RESULTS: For SSC dehiscence, MR imaging sensitivity was 100%, specificity was 96.5%, positive predictive value was 61.1%, and negative predictive value was 100% in comparison with CT. For PSC dehiscence, MR imaging sensitivity was 100%, specificity was 99.1%, positive predictive value was 33.3%, and negative predictive value was 100% in comparison with CT. CONCLUSIONS: MR imaging, with a sensitivity and negative predictive value of 100%, conclusively excludes SSC or PSC dehiscence. Negative findings on MR imaging preclude the need for CT to detect SC dehiscence. Only patients with positive findings on MR imaging should undergo CT evaluation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the technical quality and the diagnostic performance of a protocol with use of low volumes of contrast medium (25 mL) at 64-detector spiral computed tomography (CT) in the diagnosis and management of adult, nontraumatic subarachnoid hemorrhage (SAH). MATERIALS AND METHODS: This study was performed outside the United States and was approved by the institutional review board. Intracranial CT angiography was performed in 73 consecutive patients with nontraumatic SAH diagnosed at nonenhanced CT. Image quality was evaluated by two observers using two criteria: degree of arterial enhancement and venous contamination. The two independent readers evaluated diagnostic performance (lesion detection and correct therapeutic decision-making process) by using rotational angiographic findings as the standard of reference. Sensitivity, specificity, and positive and negative predictive values were calculated for patients who underwent CT angiography and three-dimensional rotational angiography. The intraclass correlation coefficient was calculated to assess interobserver concordance concerning aneurysm measurements and therapeutic management. RESULTS: All aneurysms were detected, either ruptured or unruptured. Arterial opacification was excellent in 62 cases (85%), and venous contamination was absent or minor in 61 cases (84%). In 95% of cases, CT angiographic findings allowed optimal therapeutic management. The intraclass correlation coefficient ranged between 0.93 and 0.95, indicating excellent interobserver agreement. CONCLUSION: With only 25 mL of iodinated contrast medium focused on the arterial phase, 64-detector CT angiography allowed satisfactory diagnostic and therapeutic management of nontraumatic SAH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: This study was performed to compare the sensitivity of ultrasonography, computerized tomography during arterial portography, delayed computerized tomography, and magnetic resonance imaging to detect focal liver lesions. Forty three patients with primary or secondary malignant liver lesions were studied prior to surgical intervention. METHODS: The results of the imaging studies were compared with intraoperative examination of the liver, intraoperative ultrasonography and pathology results (29 patients). In the non-operated (14 patients) group, we compared the number of lesions detected by each technique. RESULTS: One hundred and forty six lesions were detected. There was 84% sensitivity with computerized tomography during arterial portography, 61.3% with delayed scan, 63.3% with magnetic resonance imaging and 51% with ultrasonography in operated patients. In patients who did not undergo surgery, magnetic resonance imaging was more sensitive in detecting lesions. CONCLUSIONS: In operated and non-operated patients series, CT during arterial portography had the highest sensitivity, but magnetic resonance imaging had the most consistent overall results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare the diagnostic value of post-mortem computed tomography angiography (PMCTA) to conventional, ante-mortem computed tomography (CT)-scan, CT-angiography (CTA) and digital subtraction angiography (DSA) in the detection and localization of the source of bleeding in cases of acute hemorrhage with fatal outcomes. The medical records and imaging scans of nine individuals who underwent a conventional, ante-mortem CT-scan, CTA or DSA and later died in the hospital as a result of an acute hemorrhage were reviewed. Post-mortem computed tomography angiography, using multi-phase post-mortem CTA, as well as medico-legal autopsies were performed. Localization accuracy of the bleeding was assessed by comparing the diagnostic findings of the different techniques. The results revealed that data from ante-mortem and post-mortem radiological examinations were similar, though the PMCTA showed a higher sensitivity for detecting the hemorrhage source than did ante-mortem radiological investigations. By comparing the results of PMCTA and conventional autopsy, much higher sensitivity was noted in PMCTA in identifying the source of the bleeding. In fact, the vessels involved were identified in eight out of nine cases using PMCTA and only in three cases through conventional autopsy. Our study showed that PMCTA, similar to clinical radiological investigations, is able to precisely identify lesions of arterial and/or venous vessels and thus determine the source of bleeding in cases of acute hemorrhages with fatal outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 912 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. PassingBablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: αvβ3 integrin is of great interest for tumor targeting because of its high concentration in tumor tissue. It recognizes ligands containing an arginine-glycine-aspartate motif (RGD), and a number of RGD-containing peptides have been developed as PET imaging probes of angiogenesis. We synthesized a series of 18F-labeled cyclic-[RGDfK] peptides for in vivo imaging of αvβ3 expression. Our F-18 labeled prosthetic groups were attached to the αvβ3 ligand via click chemistry, and the reaction conditions (time, temperature, solvent and pH) were optimized by using single modified amino acids.Methods: Seven amino acids were selected considering their different biochemical properties (polarity, total charge, presence of aromatic ring and heteroatom). All the amino acids were modified by the introduction of azido moiety to allow the interaction with alkyne prosthetic groups. Once the conditions of the click chemistry were optimized, the prosthetic groups were also coupled with the cyclic-[RGDfK] exhibiting an azido function. 4- Trimethylammonium-nitrobenzene triflate was used as precursor for the radiosynthesis of the prosthetic groups. The fluorination was carried out with K2CO3/K2.2.2 in CH3CN at 95 oC, and the nitro group was reduced with NaBH4 and Pd/C in MeOH. The resulting 18F-aniline was subsequently coupled to alkynoic acids to yield the final F-18 labeled prosthetic groups. Finally, the prosthetic groups were attached to the peptides via Huisgen's cycloaddition. Figure 1. F-18 labeled αvβ3 ligand.Results: Our new prosthetic groups were successfully clicked to the modified amino acids and to the cyclic- [RGDfK], and the reactions were almost quantitative within 1 to 3.5 h. The pH of the reaction did not influence the reaction kinetic and yield. The four steps of the F-18 labeling were completely automated providing the final products in quantities and yields practical for PET imaging. IC50 values of our ligands for αvβ3 and α5β1 demonstrated a high selectivity of our compounds towards αvβ3, as well as the negligible effect of the prosthetic groups on the affinity of the ligand to its receptor, as confirmed by the prediction of the molecular modeling.Conclusions: We have successfully synthesized novel F-18 labeled prosthetic groups, as well as novel PET imaging probes of αvβ3 expression. The reaction conditions of the Huisgen's cycloaddition were optimized with selected modified amino acids, and subsequently transposed to the cyclic-[RGDfK] peptide. IC50 data demonstrate that our 18F-labeled ligands were selective for αvβ3. In vivo microPET/CT studies in tumor bearing mice are underway.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Cross-sectional imaging techniques have pioneered forensic medicine. The involvement of a radiographer and formation of "forensic radiographers" allows an improvement of the quality of radiological examinations and facilitates the implementation of techniques, such as sample collections, and the performance of post-mortem angiography. Methods and Materials: During a period of three months, five radiographers with clinical experience have undergone a special training in order to learn procedures dedicated to forensic imaging. These procedures involved: I). acquisition of MDCT data, II). sample collection for toxicological or histological analyses by performing CT-guided biopsies and liquid sampling, III). post-mortem angiography and IV). post-processing of all data acquired. To perform the post-mortem angiography, radiographers were in charge of the preparation of the perfusion device and the investigated body. Therefore, cannulas were inserted into the femoral vessels and connected to the machine. For angiography, the radiographers had to synchronize the perfusion with the CT-acquisitions. Results: All five radiographers have acquired new skills to become "forensic radiographers". They were able to perform post-mortem MDCT, sample collection, post-mortem angiography and post-processing of the acquired data all by themselves. Most problems have been observed concerning the preparation of the body for post-mortem angiography. Conclusion: Our experience shows that radiographers are able to perform high quality examinations after a short period of training. Their collaboration is well accepted by the forensic team and regarding the increase of radiological exams in forensic department, it would be nonsense to exclude radiographers from the forensic-radiological team.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate helical CT angiography in the assessment of occlusive arterial disease of abdominal aorta and the lower extremities. Sixteen patients underwent both transcatheter angiography and helical CT. Helical CT was inconclusive in 6.2% of segments whereas angiography was inconclusive in 5%. The overall sensitivity of helical CT was 91% and specificity 93%. Segmental analysis found a sensitivity of 43% in infrapopliteal arteries, and a specificity of 86%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cases of fatal outcome after surgical intervention are autopsied to determine the cause of death and to investigate whether medical error caused or contributed to the death. For medico-legal purposes, it is imperative that autopsy findings are documented clearly. Modern imaging techniques such as multi-detector computed tomography (MDCT) and postmortem CT angiography, which is used for vascular system imaging, are useful tools for determining cause of death. The aim of this study was to determine the utility of postmortem CT angiography for the medico-legal death investigation. This study investigated 10 medico-legal cases with a fatal outcome after surgical intervention using multi-phase postmortem whole body CT angiography. A native CT scan was performed as well as three angiographic phases (arterial, venous, and dynamic) using a Virtangio((R)) perfusion device and the oily contrast agent, Angiofil((R)). The results of conventional autopsy were compared to those from the radiological investigations. We also investigated whether the radiological findings affected the final interpretation of cause-of-death. Causes of death were hemorrhagic shock, intracerebral hemorrhage, septic shock, and a combination of hemorrhage and blood aspiration. The diagnoses were made by conventional autopsy as well as by postmortem CT angiography. Hemorrhage played an important role in eight of ten cases. The radiological exam revealed the exact source of bleeding in seven of the eight cases, whereas conventional autopsy localized the source of bleeding only generally in five of the seven cases. In one case, neither conventional autopsy nor CT angiography identified the source of hemorrhage. We conclude that postmortem CT angiography is extremely useful for investigating deaths following surgical interventions. This technique helps document autopsy findings and allows a second examination if it is needed; specifically, it detects and visualizes the sources of hemorrhages in detail, which is often of particular interest in such cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In oncology, positron emission computed tomography (PET/CT) has become an essential tool for initial staging, response evaluation and follow-up of cancer patients. Most of the frequent tumors (lung, breast, esophagus, and lymphomas) are highly avid for (18)F-fluorodeoxyglucose ((18)FDG), but prostate cancer has not demonstrated significant uptake of FDG. The development of new tracers labeled with (18)F such as choline analogs allowed already to obtain interesting results particularly in patients with biological relapse and inconclusive conventional imaging workup. The impact of (18)F-flurocholine PET/CT on patient management needs to be validated in large studies, but many centers use already this examination in order to guide further management, including radiotherapy planning. (C) 2011 Elsevier Masson SAS. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Knowledge of cerebral blood flow (CBF) alterations in cases of acute stroke could be valuable in the early management of these cases. Among imaging techniques affording evaluation of cerebral perfusion, perfusion CT studies involve sequential acquisition of cerebral CT sections obtained in an axial mode during the IV administration of iodinated contrast material. They are thus very easy to perform in emergency settings. Perfusion CT values of CBF have proved to be accurate in animals, and perfusion CT affords plausible values in humans. The purpose of this study was to validate perfusion CT studies of CBF by comparison with the results provided by stable xenon CT, which have been reported to be accurate, and to evaluate acquisition and processing modalities of CT data, notably the possible deconvolution methods and the selection of the reference artery. METHODS: Twelve stable xenon CT and perfusion CT cerebral examinations were performed within an interval of a few minutes in patients with various cerebrovascular diseases. CBF maps were obtained from perfusion CT data by deconvolution using singular value decomposition and least mean square methods. The CBF were compared with the stable xenon CT results in multiple regions of interest through linear regression analysis and bilateral t tests for matched variables. RESULTS: Linear regression analysis showed good correlation between perfusion CT and stable xenon CT CBF values (singular value decomposition method: R(2) = 0.79, slope = 0.87; least mean square method: R(2) = 0.67, slope = 0.83). Bilateral t tests for matched variables did not identify a significant difference between the two imaging methods (P >.1). Both deconvolution methods were equivalent (P >.1). The choice of the reference artery is a major concern and has a strong influence on the final perfusion CT CBF map. CONCLUSION: Perfusion CT studies of CBF achieved with adequate acquisition parameters and processing lead to accurate and reliable results.