989 resultados para Load tests
Resumo:
Objective: To compare head relocation accuracy in traumatic ( whiplash), insidious onset neck pain patients and asymptomatic subjects when targeting a natural head posture (NHP) and complex predetermined positions. Design: A case-control study. Setting: University-based musculoskeletal research clinic. Participants: Sixty-three volunteers divided into three groups of similar gender and age: Group 1 (n=21) an asymptomatic group; group 2 (n=20) insidious onset neck pain; group 3 (n=22) a history of whiplash injury. Intervention: Five randomly ordered tests designed to detect relocation accuracy of the head. Outcome measures: A 3-Space Fastrak system measured the mean absolute relocation error of three trials of each relocation test. Results: A significant difference was found between groups in one of the tests targeting the NHP (p=0.001). Post-hoc pairwise comparisons revealed a significant difference (pless than or equal to0.05) between the asymptomatic group and each symptomatic group. The difference between the symptomatic groups just failed to reach significance (p=0.07). None of the other four tests revealed significant differences. Conclusion: The test of targeting the NHP indicates that relocation inaccuracy exists in patients with neck pain with a trend to suggest that the deficit may be greater in whiplash patients. Tests employing unfamiliar postures or more complex movement were not successful in differentiating subject groups.
Resumo:
Objective To develop and validate specific, sensitive and rapid diagnostic tests using RT-PCR for the detection of Ross River virus (RRV), Kunjin virus (KV) and Murray Valley encephalitis virus (MVEV) infections in horses. Methods Primer sets based on nucleotide sequence encoding the envelope glycoprotein E2 of RRV and on the nonstructural protein 5 (NS5) of KV and MVEV were designed and used in single round PCRs to test for the respective viruses in infected cell cultures and, in the case of RRV, in samples of horse blood and synovial fluid. Results The primer pairs designed for each of the three viruses amplified a product of expected size from prototype viruses that were grown in cell culture. The identity of each of the products was confirmed by nucleotide sequencing indicating that in the context used the RT-PCRs were specific. RRV was detected in serums from 8 horses for which there were clinical signs consistent with RRV infection such that an acute-phase serum sample was taken and submitted for RRV serology testing. The RRV RT-PCR was analytically sensitive in that it was estimated to detect as little as 50 TCID50 of RRV per mL of serum and was specific in that the primer pairs did not amplify other products from the 8 serum samples. The RRV primers also detected virus in three independent mosquito pools known to contain RRV by virus isolation in cell culture. Samples from horses suspected to be infected with KV and MVEV were not available. Conclusion Despite much anecdotal and serological evidence for infection of horses with RRV actual infection and associated clinical disease are infrequently confirmed. The availability of a specific and analytically sensitive RT-PCR for the detection of RRV provides additional opportunities to confirm the presence of this virus in clinical samples. The RTPCR primers for the diagnosis of KV and MVEV infections were shown to be specific for cell culture grown viruses but the further validation of these tests requires the availability of appropriate clinical samples from infected horses.
Resumo:
This paper is concerned with evaluating the performance of loss networks. Accurate determination of loss network performance can assist in the design and dimen- sioning of telecommunications networks. However, exact determination can be difficult and generally cannot be done in reasonable time. For these reasons there is much interest in developing fast and accurate approximations. We develop a reduced load approximation that improves on the famous Erlang fixed point approximation (EFPA) in a variety of circumstances. We illustrate our results with reference to a range of networks for which the EFPA may be expected to perform badly.
Resumo:
Neste trabalho, as distribuições de tamanhos das partículas de dois pós de Carboneto de Silício foram previamente avaliadas e os resultados indicaram uma distribuição Gaussiana para ambos, com tamanhos médios na ordem de 2 μm para o primeiro e 6 μm para o segundo. Posteriormente foram misturados os dois pós originais com diferentes frações mássicas, proporcionando uma nova série de pós de Carboneto de Silício (SiC), que seriam usados nos ensaios de microabrasão com configuração de esfera fixa. A caracterização desta nova série de pós mostrou larguras maiores para aqueles com alto porcentagem do abrasivo pequeno (2,11 μm), conservando a aparência Gaussiana dos originais. Por outro lado para os pós com uma quantidade maior do abrasivo grande (6,57 μm), foram obtidas curvas com uma leve tendência bimodal, mas também apresentaram maiores larguras. As provas foram conduzidas sobre aço carbono AISI 1020, para duas condições diferentes de carga normal e os resultados foram analisados em termos da taxa de desgaste, bem como dos micromecanismos de desgaste (abrasão por rolamento ou abrasão por riscamento). Os resultados indicaram que a fração mássica dos pós originais tem um efeito significante sobre os micromecanismos de desgaste observados e que as taxas de desgaste não segue uma relação linear com a fração mássica do pó com maior tamanho da partícula abrasiva. Além disso, a análise da severidade de contato determinou que esta diminui durante os ensaios conduzidos com carga constante. Este fenômeno está associado ao aumento da área da cratera de desgaste que produz uma diminuição da pressão de contato. Assim, um incremento para o número de eventos associado ao rolamento de partículas seria esperado, favorecendo a observação de múltiplas indentações ao longo dos sulcos formados previamente. Isto foi confirmado por meio de micrografias eletrônicas de varredura das amostras após ensaios de microabrasão.
Resumo:
O coeficiente de atrito e o desgaste nas superligas de cobalto são fortemente influenciados pela transformação de fase de CFC para HC que ocorre devido ao trabalho mecânico, conforme já reportado pela literatura. Após essa transformação, os valores de μ costumam se situar na faixa de 0,15 a 0,20. Este trabalho apresenta o comportamento do atrito e do desgaste em um ensaio de deslizamento sem lubrificação utilizando uma configuração pino-disco, sendo o pino feito de aço inoxidável supermartensítico e o disco de uma superliga de cobalto fundida, num tribômetro PLINT TE67. Os ensaios foram conduzidos em temperatura ambiente, com uma velocidade e variando-se a carga normal de deslizamento entre 5 e 500 N. O coeficiente de atrito e o potencial elétrico de contato foram monitorados durante os ensaios. Utilizou-se a MEV e a perfilometria 3D para caracterizar o volume e o mecanismo de desgaste. Para as cargas de 350, 400 e 450 N, após atingir condições de regime estacionário, um valor de coeficiente de atrito não usual (μ<0,01) e uma baixa taxa de desgaste foram encontradas. A análise da difração de raios-X revelou a presença de transformação de fases.
Resumo:
Wireless medical systems are comprised of four stages, namely the medical device, the data transport, the data collection and the data evaluation stages. Whereas the performance of the first stage is highly regulated, the others are not. This paper concentrates on the data transport stage and argues that it is necessary to establish standardized tests to be used by medical device manufacturers to provide comparable results concerning the communication performance of the wireless networks used to transport medical data. Besides, it suggests test parameters and procedures to be used to produce comparable communication performance results.
Resumo:
This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. This study is defined as study of diagnostic performance. The diagnostic accuracy of 5 visual tests -near convergence point, near accommodation point, stereopsis, contrast sensibility and amsler grid—was evaluated by means of the ROC method (receiver operating characteristics curves), sensitivity, specificity, positive and negative likelihood ratios (LR+/LR−). Visual acuity was used as the reference standard. A sample of 44 elderly aged 76.7 years (±9.32), who were institutionalized, was collected. The curves of contrast sensitivity and stereopsis are the most accurate (area under the curves were 0.814−p = 0.001, C.I.95%[0.653;0.975]— and 0.713−p = 0.027, C.I.95%[0,540;0,887], respectively). The scores with the best diagnostic validity for the stereopsis test were 0.605 (sensitivity 0.87, specificity 0.54; LR+ 1.89, LR−0.24) and 0.610 (sensitivity 0.81, specificity 0.54; LR+1.75, LR−0.36). The scores with higher diagnostic validity for the contrast sensibility test were 0.530 (sensitivity 0.94, specificity 0.69; LR+ 3.04, LR−0.09). The contrast sensitivity and stereopsis test's proved to be clinically useful in detecting vision loss in the elderly.
Resumo:
The aging of Portuguese population is characterized by an increase of individuals aged older than 65 years. Preventable visual loss in older persons is an important public health problem. Tests used for vision screening should have a high degree of diagnostic validity confirmed by means of clinical trials. The primary aim of a screening program is the early detection of visual diseases. Between 20% and 50% of older people in the UK have undetected reduced vision and in most cases is correctable. Elderly patients do not receive a systematic eye examination unless a problem arises with their glasses or suspicion vision loss. This study aimed to determine and evaluate the diagnostic accuracy of visual screening tests for detecting vision loss in elderly. Furthermore, it pretends to define the ability to find the subjects affected with vision loss as positive and the subjects not affected with the same disease as negative. The ideal vision screening method should have high sensitivity and specificity for early detection of risk factors. It should be also low cost and easy to implement in all geographic and socioeconomic regions. Sensitivity is the ability of an examination to identify the presence of a given disease and specificity is the ability of the examination to identify the absence of a given disease. It was not an aim of this study to detect abnormalities that affect visual acuity. The aim of this study was to find out what´s the best test for the identification of any vision loss.
Resumo:
Nesta dissertação descreve-se uma metodologia de dimensionamento do sistema de tracção para equipar um veículo eléctrico ecológico (VEECO) com inclusão de um sistema de travagem regenerativa. Apresenta-se uma perspectiva geral de diversas topologias de sistemas de tracção utilizadas nos veículos eléctricos e realiza-se a sua comparação através do estudo e análise dos acionamentos electromecânicos que podem ser utilizados nesses sistemas de tracção eléctrica. Utilizando ferramentas de simulação numérica, estuda-se o modelo matemático de um veículo eléctrico com travagem regenerativa. A partir deste modelo matemático é adoptado uma possível configuração para o seu sistema de tracção eléctrica e são obtidas características teóricas de desempenho do veículo eléctrico, através da análise de testes padrão ao veículo. Em banco de ensaios, constrói-se um sistema de tracção eléctrica que permite a validação experimental do modelo matemático do veículo eléctrico. Para a construção deste banco de ensaios foram concebidos os sistemas de tracção eléctrica, de carga mecânica e de controlo e monitorização do banco de ensaios. A validação experimental realiza-se através dos mesmos testes padrão ao veículo eléctrico, como o teste NEDC (New European Driving Cycle), o teste de aceleração entre 0 e 100km/h e o teste de gradeabilidade. Desenvolve-se o dimensionamento do sistema de tracção eléctrica a equipar o VEECO, através da componente de modelação paramétrica do modelo matemático do veículo eléctrico. Com esta metodologia é adoptado um conjunto de variáveis paramétricas relacionadas com os elementos que constituem o sistema de tracção eléctrica do VEECO. Estuda-se a influência destas variáveis paramétricas nas características de desempenho pretendidas para o VEECO. Como resultado da análise de modelação paramétrica é apresentada uma solução para o sistema de tracção eléctrica do VEECO que cumpre a execução do NEDC, apresenta um tempo de aceleração entre 0 e 100km/h inferior a 10 segundos, supera uma gradeabilidade de 10% e uma autonomia de 200 km. O sistema de tracção do VEECO também permite realizar a travagem regenerativa com rendimento até 33%. Possui controlo de tracção e anti bloqueio da roda motora, através de uma unidade de controlo que permite reduzir a potência transmitida ao veio, quando a velocidade da roda de tracção difere do valor de referência da velocidade do veículo. Os conhecimentos adquiridos através do processo de investigação e desenvolvimento, para a realização da presente dissertação permitem apresentar perspectivas de desenvolvimento futuro com aplicação nos sistemas de tracção de veículos eléctricos rodoviários.
Resumo:
Preliminary version
Resumo:
Multiple-Choice items are used in many different kinds of tests in several areas of knowledge. They can be considered an interesting tool to the self-assessing or as an alternative or complementary instrument to the traditional methods for assessing knowledge. The objectivity and accuracy of the multiple-choice tests is an important reason to think about. They are especially useful when the number of students to evaluate is too large. Moodle (Modular Object-Oriented Dynamic Learning Environment) is an Open Source course management system centered around learners' needs and designed to support collaborative approaches to teaching and learning. Moodle offers to the users a rich interface, context-specific help buttons, and a wide variety of tools such as discussion forums, wikis, chat, surveys, quizzes, glossaries, journals, grade books and more, that allow them to learn and collaborate in a truly interactive space. Come together the interactivity of the Moodle platform and the objectivity of this kind of tests one can easily build manifold random tests. The proposal of this paper is to relate our journey in the construction of these tests and share our experience in the use of the Moodle platform to create, take advantage and improve the multiple-choices tests in the Mathematic area.
Resumo:
The purpose of this paper is to analyse if Multiple-Choice Tests may be considered an interesting alternative for assessing knowledge, particularly in the Mathematics area, as opposed to the traditional methods, such as open questions exams. In this sense we illustrate some opinions of the researchers in this area. Often the perception of the people about the construction of this kind of exams is that they are easy to create. But it is not true! Construct well written tests it’s a hard work and needs writing ability from the teachers. Our proposal is analyse the construction difficulties of multiple - choice tests as well some advantages and limitations of this type of tests. We also show the frequent critics and worries, since the beginning of this objective format usage. Finally in this context some examples of Multiple-Choice Items in the Mathematics area are given, and we illustrate as how we can take advantage and improve this kind of tests.
Resumo:
A definition of medium voltage (MV) load diagrams was made, based on the data base knowledge discovery process. Clustering techniques were used as support for the agents of the electric power retail markets to obtain specific knowledge of their customers’ consumption habits. Each customer class resulting from the clustering operation is represented by its load diagram. The Two-step clustering algorithm and the WEACS approach based on evidence accumulation (EAC) were applied to an electricity consumption data from a utility client’s database in order to form the customer’s classes and to find a set of representative consumption patterns. The WEACS approach is a clustering ensemble combination approach that uses subsampling and that weights differently the partitions in the co-association matrix. As a complementary step to the WEACS approach, all the final data partitions produced by the different variations of the method are combined and the Ward Link algorithm is used to obtain the final data partition. Experiment results showed that WEACS approach led to better accuracy than many other clustering approaches. In this paper the WEACS approach separates better the customer’s population than Two-step clustering algorithm.
Resumo:
With the electricity market liberalization, the distribution and retail companies are looking for better market strategies based on adequate information upon the consumption patterns of its electricity consumers. A fair insight on the consumers’ behavior will permit the definition of specific contract aspects based on the different consumption patterns. In order to form the different consumers’ classes, and find a set of representative consumption patterns we use electricity consumption data from a utility client’s database and two approaches: Two-step clustering algorithm and the WEACS approach based on evidence accumulation (EAC) for combining partitions in a clustering ensemble. While EAC uses a voting mechanism to produce a co-association matrix based on the pairwise associations obtained from N partitions and where each partition has equal weight in the combination process, the WEACS approach uses subsampling and weights differently the partitions. As a complementary step to the WEACS approach, we combine the partitions obtained in the WEACS approach with the ALL clustering ensemble construction method and we use the Ward Link algorithm to obtain the final data partition. The characterization of the obtained consumers’ clusters was performed using the C5.0 classification algorithm. Experiment results showed that the WEACS approach leads to better results than many other clustering approaches.
Resumo:
The present research paper presents five different clustering methods to identify typical load profiles of medium voltage (MV) electricity consumers. These methods are intended to be used in a smart grid environment to extract useful knowledge about customer’s behaviour. The obtained knowledge can be used to support a decision tool, not only for utilities but also for consumers. Load profiles can be used by the utilities to identify the aspects that cause system load peaks and enable the development of specific contracts with their customers. The framework presented throughout the paper consists in several steps, namely the pre-processing data phase, clustering algorithms application and the evaluation of the quality of the partition, which is supported by cluster validity indices. The process ends with the analysis of the discovered knowledge. To validate the proposed framework, a case study with a real database of 208 MV consumers is used.