998 resultados para LONGITUDINAL ACOUSTICAL MODE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern fully integrated transceivers architectures, require circuits with low area, low cost, low power, and high efficiency. A key block in modern transceivers is the power amplifier, which is deeply studied in this thesis. First, we study the implementation of a classical Class-A amplifier, describing the basic operation of an RF power amplifier, and analysing the influence of the real models of the reactive components in its operation. Secondly, the Class-E amplifier is deeply studied. The different types of implementations are reviewed and theoretical equations are derived and compared with simulations. There were selected four modes of operation for the Class-E amplifier, in order to perform the implementation of the output stage, and the subsequent comparison of results. This led to the selection of the mode with the best trade-off between efficiency and harmonics distortion, lower power consumption and higher output power. The optimal choice was a parallel circuit containing an inductor with a finite value. To complete the implementation of the PA in switching mode, a driver was implemented. The final block (output stage together with the driver) got 20 % total efficiency (PAE) transmitting 8 dBm output power to a 50 W load with a total harmonic distortion (THD) of 3 % and a total consumption of 28 mW. All implementations are designed using standard 130 nm CMOS technology. The operating frequency is 2.4 GHz and it was considered an 1.2 V DC power supply. The proposed circuit is intended to be used in a Bluetooth transmitter, however, it has a wider range of applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an on-board Electric Vehicle (EV) battery charger with enhanced Vehicle-to-Home (V2H) operation mode. For such purpose was adapted an on-board bidirectional battery charger prototype to allow the Grid-to-Vehicle (G2V), Vehicle-to-Grid (V2G) and V2H operation modes. Along the paper are presented the hardware topology and the control algorithms of this battery charger. The idea underlying to this paper is the operation of the on-board bidirectional battery charger as an energy backup system when occurs a power outages. For detecting the power outage were compared two strategies, one based on the half-cycle rms calculation of the power grid voltage, and another in the determination of the rms value based in a Kalman filter. The experimental results were obtained considering the on-board EV battery charger under the G2V, V2G, and V2H operation modes. The results show that the power outage detection is faster using a Kalman filter, up to 90% than the other strategy. This also enables a faster transition between operation modes when a power outage occurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research is showing that the addition of Recycled Steel Fibres (RSF) from wasted tyres can decrease significantly the brittle behaviour of cement based materials, by improving its toughness and post-cracking resistance. In this sense, Recycled Steel Fibre Reinforced Concrete (RSFRC) seems to have the potential to constitute a sustainable material for structural and non-structural applications. To assess this potential, experimental and numerical research was performed on the use of RSFRC in elements failing in bending and in beams failing in shear. The values of the fracture mode I parameters of the developed RSFRC were determined by performing inverse analysis with test results obtained in three point notched beam bending tests. To assess the possibility of using RSF as shear reinforcement in Reinforced Concrete (RC) beams, three point bending tests were executed with three series of RSFRC beams flexurally reinforced with a relatively high reinforcement ratio of longitudinal steel bars in order to assure shear failure for all the tested beams. By performing material nonlinear simulations with a computer program based on the finite element method (FEM), the applicability of the fracture mode I crack constitutive law derived from the inverse analysis is assessed for the prediction of the behaviour of these beams. The performance of the formulation proposed by RILEM TC 162 TDF and CEB-FIP 2010 for the prediction of the shear resistance of fibre reinforced concrete elements was also evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Our Lady of Conception church is located in village of Monforte (Portugal) and is not in use nowadays. The church presents structural damage and, consequently, a study was carried out. The study involved the survey of the damage, dynamic identification tests under ambient vibration and the numerical analysis. The church is constituted by the central nave, the chancel, the sacristy and the corridor to access the pulpit. The masonry walls present different thickness, namely 0.65 m in the chancel, 0.70 m in the sacristy, 0.92 in the central nave and 0.65 m in the corridor. The masonry walls present 8 buttresses with different dimensions. The total longitudinal and transversal dimensions of the church are equal to 21.10 m and 14.26 m, respectively. The survey of the damage showed that, in general, the masonry walls are in good conditions, with exception of the transversal walls of the nave, which present severe cracks. The arches of the vault presents also severe cracks along the central nave. As consequence, the infiltrations have increased the degradation of the vault and paintings. Furthermore, the foundations present settlements in the Southwest direction. The dynamic identification test were carried out under the action of ambient excitation of the wind and using 12 piezoelectric accelerometers of high sensitivity. The dynamic identification tests allowed to estimate the dynamic properties of the church, namely frequencies, mode shapes and damping ratios. A FEM numerical model was prepared and calibrated, based on the first four experimental modes estimated in the dynamic identification tests. The average error between the experimental and numerical frequencies of the first four modes is equal to 5%. After calibration of the numerical model, pushover analyses with a load pattern proportional to the mass, in the transversal and longitudinal direction of the church, were performed. The results of the analysis numerical allow to conclude that the most vulnerable direction of the church is in the transversal one and the maximum load factor is equal to 0.35.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A search for a charged Higgs boson, H±, decaying to a W± boson and a Z boson is presented. The search is based on 20.3 fb−1 of proton-proton collision data at a center-of-mass energy of 8 TeV recorded with the ATLAS detector at the LHC. The H± boson is assumed to be produced via vector-boson fusion and the decays W±→qq′¯ and Z→e+e−/μ+μ− are considered. The search is performed in a range of charged Higgs boson masses from 200 to 1000 GeV. No evidence for the production of an H± boson is observed. Upper limits of 31--1020 fb at 95% CL are placed on the cross section for vector-boson fusion production of an H± boson times its branching fraction to W±Z. The limits are compared with predictions from the Georgi-Machacek Higgs Triplet Model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a single-phase reconfigurable battery charger for Electric Vehicle (EV) that operates in three different modes: Grid-to-Vehicle (G2V) mode, in which the traction batteries are charged from the power grid; Vehicle-to-Grid (V2G) mode, in which the traction batteries deliver part of the stored energy back to the power grid; and in Traction-to-Auxiliary (T2A) mode, in which the auxiliary battery is charged from the traction batteries. When connected to the power grid, the battery charger works with sinusoidal current in the AC side, for both G2V and V2G modes, and also regulates the reactive power. When the EV is disconnected from the power grid, the control algorithms are modified and the full-bridge AC-DC bidirectional converter works as a full-bridge isolated DC-DC converter that is used to charge the auxiliary battery of the EV, avoiding the use of an additional charger to accomplish this task. To assess the behavior of the proposed reconfigurable battery charger under different operation scenarios, a 3.6 kW laboratory prototype has been developed and experimental results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long-term exposure to transmeridian flights has been shown to impact cognitive functioning. Nevertheless, the immediate effects of jet lag in the activation of specific brain networks have not been investigated. We analyzed the impact of short-term jet lag on the activation of the default mode network (DMN). A group of individuals who were on a transmeridian flight and a control group went through a functional magnetic resonance imaging acquisition. Statistical analysis was performed to test for differences in the DMN activation between groups. Participants from the jet lag group presented decreased activation in the anterior nodes of the DMN, specifically in bilateral medial prefrontal and anterior cingulate cortex. No areas of increased activation were observed for the jet lag group. These results may be suggestive of a negative impact of jet lag on important cognitive functions such as introspection, emotional regulation and decision making in a few days after individuals arrive at their destination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências (Especialidade em Matemática)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Undergraduate medical education is moving from traditional disciplinary basic science courses into more integrated curricula. Integration models based on organ systems originated in the 1950s, but few longitudinal studies have evaluated their effectiveness. This article outlines the development and implementation of the Organic and Functional Systems (OFS) courses at the University of Minho in Portugal, using evidence collected over 10 years. It describes the organization of content, student academic performance and acceptability of the courses, the evaluation of preparedness for future courses and the retention of knowledge on basic sciences. Students consistently rated the OFS courses highly. Physician tutors in subsequent clinical attachments considered that students were appropriately prepared. Performance in the International Foundations of Medicine examination of a self-selected sample of students revealed similar performances in basic science items after the last OFS course and 4 years later, at the moment of graduation. In conclusion, the organizational and pedagogical approaches of the OFS courses achieve high acceptability by students and result in positive outcomes in terms of preparedness for subsequent training and long-term retention of basic science knowledge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivos : Constatando que a depressão é comum em idosos institucionalizados, associando-se à solidão, à ansiedade e à afetividade, pretendemos descrever a evolução da depressão durante dois anos e verificar que fatores se associam a essa evolução. Métodos : Em um estudo de coorte prospectivo em dois momentos (2011 e 2013), avaliamos 83 idosos institucionalizados, com idade no primeiro momento entre os 60 e os 100 anos, sendo 79,5% mulheres, 86,7% sem companheiro(a), e 72,3% com algum grau de escolaridade. Usamos a Escala Geriátrica da Depressão (GDS), a Escala de Solidão (UCLA-L), o Inventário Geriátrico de Ansiedade (GAI) e a Lista de Afetos Positivos e Negativos (PANAS). Resultados: Verificamos que 59,0% mantiveram a depressão e 10,8% desenvolveram depressão. Os idosos com depressão tiveram significativamente piores resultados na UCLA, GAI e PANAS, e os não depressivos tiveram afetos positivos mais altos. Quanto à evolução da depressão, os idosos que mantiveram depressão tiveram inicialmente pontuações elevadas no GDS, GAI, UCLA e na subescala PANAS negativo e pontuações baixas na subescala PANAS positivo. Esses idosos apresentaram associadamente um agravamento dos sentimentos de solidão, dos sintomas ansiosos e do afeto negativo ao longo dos dois anos. Os que desenvolveram depressão tiveram, no primeiro momento, pontuações elevadas na UCLA. Conclusões: Os sintomas de depressão com ou sem solidão no momento inicial, o agravamento da solidão, a ansiedade, o afeto negativo e o baixo afeto positivo poderão ser fatores de risco para a manutenção da depressão. A solidão poderá ainda ser um fator de risco para o desenvolvimento de depressão.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Allied to an epidemiological study of population of the Senology Unit of Braga’s Hospital that have been diagnosed with malignant breast cancer, we describe the progression in time of repeated measurements of tumor marker Carcinoembryonic antigen (CEA). Our main purpose is to describe the progression of this tumor marker as a function of possible risk factors and, hence, to understand how these risk factors influences that progression. The response variable, values of CEA, was analyzed making use of longitudinal models, testing for different correlation structures. The same covariates used in a previous survival analysis were considered in the longitudinal model. The reference time used was time from diagnose until death from breast cancer. For diagnostic of the models fitted we have used empirical and theoretical variograms. To evaluate the fixed term of the longitudinal model we have tested for a changing point on the effect of time on the tumor marker progression. A longitudinal model was also fitted only to the subset of patients that died from breast cancer, using the reference time as time from date of death until blood test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Decision-making on embryo disposition is a source of distress and is subject to change over time. This paper analyses the willingness of couples undergoing in vitro fertilization to donate cryopreserved embryos for research from 15 days after embryo transfer to 12 months later, taking into account the influence of psychosocial, demographic, and reproductive factors. Materials and methods. Prospective longitudinal study, with 74 heterosexual couples undergoing in vitro fertilization in a public fertility centre in Portugal, recruited between 2011 and 2012. Participants were evaluated twice: 15 days after embryo transfer and 12 months later. Results. A significant decrease in patients’ willingness to donate embryos for research over time was observed [86.5% to 73.6%; relative risk (RR) = 0.85; 95% CI 0.76–0.95]. A higher education level (>12 years) [adjusted RR (RRadj) = 0.79; 95% CI 0.64–0.96], considering research on human embryos to be important (vs. very important) (RRadj = 0.59; 95% CI 0.39–0.85) and practicing a religion less than once a month (vs. at least once a month) (RRadj = 0.73; 95% CI 0.53–1.00) seemed associated with unwillingness to donate embryos for research over time. Change towards non-donation happened mainly among couples who first considered that it was better to donate than wasting the embryos. Change towards donation occurred mostly among those stating that their priority at time 1 was to have a baby and who became pregnant in the meantime. Conclusions. Quality of care guided by patients’ characteristics, values, preferences, and needs calls for considering the factors and reasons underlying couples’ willingness to donate embryos for research over time as a topic in psychosocial guidelines for infertility and medically assisted reproductive care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Article first published online: 13 NOV 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Determinação da freqüência das alterações cardíacas e sua evolução nas crianças expostas ao HIV-1 por via perinatal. MÉTODOS: Realizada avaliação seqüencial clínico-cardiológica, eletrocardiográfica e ecocardiográfica Doppler em 84 crianças expostas ao HIV-1. RESULTADOS: Grupo I (sororreversão) 43 crianças (51,2%). Ausência de alterações clínicas. ECG: distúrbio de condução de ramo direito 5 casos. ECO: CIA (1 caso) e CIV (1 caso). Grupo II 41 infectados (48,8%) com 51,2% de alterações cardiológicas. Crianças assintomáticas ou com sintomas leves, sem imunossupressão: alterações clínico-ecocardiográficas ausentes; ECG: distúrbio de condução de ramo direito (2 casos). Crianças com comprometimento clínico-imunológico moderado e severo: Alterações encontradas: 1) Clínicas (31,7%): taquicardia isolada (1 caso), ICC (12 casos). 2) Eletrocardiográficas (43,9%): taquicardia sinusal associada a outras alterações (10 casos), distúrbio de condução de ramo direito (5 casos), BDAS (1 caso), HBAD (1 caso), alterações da repolarização ventricular (11 casos), SVD (2 casos), SVE (1 caso), desvio do AQRS para direita (1 caso), arritmias (3 casos). 3) Ecocardiográficas (26,8%): miocardiopatia dilatada (5 casos), derrame pericárdico com tamponamento (2 casos), hipertensão pulmonar (2 casos) e prolapso da valva mitral (1 caso). CONCLUSÃO: O envolvimento cardíaco foi uma característica do grupo infectado. Houve maior prevalência de alterações nas crianças pertencentes à categoria clínico-imunológica mais avançada. Os achados clínicos, eletrocardiográficos e ecocardiográficos mais freqüentes foram, respectivamente, ICC, alterações da repolarização ventricular e miocardiopatia dilatada. Esta foi reversível em um caso. As alterações eletrocardiográficas foram significantemente mais freqüentes que as clínicas e ecocardiográficas.