869 resultados para Knee prosthesis replacement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Brazil, carbapenem-resistant Pseudomonas aeruginosa isolates are closely related to the São Paulo metallo-β-lactamase (SPM) Brazilian clone. In this study, imipenem-resistant isolates were divided in two sets, 2002/2003 and 2008/2009, analysed by pulsed field gel electrophoresis and tested for the Ambler class B metallo-β-lactamase (MBL) genes blaSPM-1, blaIMP and blaVIM. The results show a prevalence of one clone related to the SPM Brazilian clone in 2002/2003. In 2008/2009, P. aeruginosa isolates were mostly MBL negative, genetically diverse and unrelated to those that had been detected earlier. These findings suggest that the resistance to carbapenems by these recent P. aeruginosa isolates was not due to the spread of MBL-positive SPM-related clones, as often observed in Brazilian hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dengue fever is the most important arbovirus infection found in tropical regions around the world. Dispersal of the vector and an increase in migratory flow between countries have led to large epidemics and severe clinical outcomes, such as dengue haemorrhagic fever and dengue shock syndrome. This study analysed the genetic variability of the dengue virus serotype 1 (DENV-1) in Brazil with regard to the full-length structural genes C/prM/M/E among 34 strains isolated during epidemics that occurred in the country between 1994-2011. Virus phylogeny and time of divergence were also evaluated with only the E gene of the strains isolated from 1994-2008. An analysis of amino acid differences between these strains and the French Guiana strain (FGA/89) revealed the presence of important nonsynonymous substitutions in the amino acid sequences, including residues E297 (Met→Thr) and E338 (Ser→Leu). A phylogenetic analysis of E proteins comparing the studied isolates and other strains selected from the GenBank database showed that the Brazilian DENV-1 strains since 1982 belonged to genotype V. This analysis also showed that different introductions of strains from the 1990s represented lineage replacement, with the identification of three lineages that cluster all isolates from the Americas. An analysis of the divergence time of DENV-1 indicated that the lineage circulating in Brazil emerged from an ancestral lineage that originated approximately 44.35 years ago.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Ankle arthropathy is associated with a decreased motion of the ankle-hindfoot during ambulation. Ankle arthrodesis was shown to result in degeneration of the neighbour joints of the foot. Inversely, total ankle arthroplasty conceptually preserves the adjacent joints because of the residual mobility of the ankle but this has not been demonstrated yet in vivo. It has also been reported that degenerative ankle diseases, and even arthrodesis, do not result in alteration of the knee and hip joints. We present the preliminary results of a new approach of this problem based on ambulatory gait analysis. Patients and Methods: Motion analysis of the lower limbs was performed using a Physilog® (BioAGM, CH) system consisting of three-dimensional (3D) accelerometer and gyroscope, coupled to a magnetic system (Liberty©, Polhemus, USA). Both systems have been validated. Three groups of two patients were included into this pilot study and compared to healthy subjects (controls) during level walking: patients with ankle osteoarthritis (group 1), patients treated by ankle arthrodesis (group 2), patients treated by total ankle prosthesis (group 3). Results: Motion patterns of all analyzed joints over more than 20 gait cycles in each subject were highly repeatable. Motion amplitude of the ankle-hindfoot in control patients was similar to recently reported results. Ankle arthrodesis limited the motion of the ankle-hindfoot in the sagittal and horizontal planes. The prosthetic ankle allowed a more physiologic movement in the sagittal plane only. Ankle arthritis and its treatments did not influence the range of motion of the knee and hip joint during stance phase, excepted for a slight decrease of the hip flexion in groups 1 and 2. Conclusion: The reliability of the system was shown by the repeatability of the consecutive measurements. The results of this preliminary study were similar to those obtained through laboratory gait analysis. However, our system has the advantage to allow ambulatory analysis of 3D kinematics of the lower limbs outside of a gait laboratory and in real life conditions. To our knowledge this is a new concept in the analysis of ankle arthropathy and its treatments. Therefore, there is a potential to address specific questions like the difficult comparison of the benefits of ankle arthroplasty versus arthrodesis. The encouraging results of this pilot study offer the perspective to analyze the consequences of ankle arthropathy and its treatments on the biomechanics of the lower limbs ambulatory, in vivo and in daily life conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today, reconstructive arthroscopic knee surgery of the anterior cruciate ligament is a widely used technique. In addition to the usual complications of arthroscopic techniques, the extraction of the piece must be taken into consideration, with vascular complications being the rarest and most serious of them all. We present the case of a patient who suffered an arterial pseudoaneurysm during this procedure. The management and treatment are discussed and the current bibliography reviewed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 49-year-old woman, without known cardiovascular risk factors. Hoarseness of voice caused by a paralysis of left vocal cord. She was admitted to hospital because of acute coronary syndrome, associated to resuscitated cardiac arrest (asystolia documented) without later neurology sequels. Physical examination was anodyne. Echocardiographic study demonstrated a compatible image with a large left sinus of Valsalva aneurysm (SVA) (Panel A) and mild aortic regurgitation. Cardiac catheterization confirmed the presence of left SVA (Panel B) that produced extrinsic compression of the left main coronary artery (Panels C and D). Repair surgery was made by means of closing the aneurysmal orifice with a patch of dacron. Intra-operatory echocardiographic control study found severe aortic regurgitation, so valvular replacement with 19 mm mechanical prosthesis and extension of the valve annulus with patch of dacron was performed, associated with bypass with safena vein graft to left coronary artery. SVA is a very infrequent cardiac anomaly, generally with silent clinical course until it ruptures. Myocardial ischaemia caused by coronary artery compression is unusual. We described the case of a patient diagnosed of left SVA, whose initial clinical manifestation was the appearance of resuscitated sudden cardiac death in the context of an acute coronary syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimum treatment for prosthetic joint infections has not been clearly defined. We report our experience of the management of acute haematogenous prosthetic joint infection (AHPJI) in patients during a 3-year prospective study in nine Spanish hospitals. Fifty patients, of whom 30 (60%) were female, with a median age of 76 years, were diagnosed with AHPJI. The median infection-free period following joint replacement was 4.9 years. Symptoms were acute in all cases. A distant previous infection and/or bacteraemia were identified in 48%. The aetiology was as follows: Staphylococcus aureus, 19; Streptococcus spp., 14; Gram-negative bacilli, 12; anaerobes, two; and mixed infections, three. Thirty-four (68%) patients were treated with a conservative surgical approach (CSA) with implant retention, and 16 had prosthesis removal. At 2-year follow-up, 24 (48%) were cured, seven (14%) had relapsed, seven (14%) had died, five (10%) had persistent infection, five had re-infection, and two had an unknown evolution. Overall, the treatment failure rates were 57.8% in staphylococcal infections and 14.3% in streptococcal infections. There were no failures in patients with Gram-negative bacillary. By multivariate analysis, CSA was the only factor independently associated with treatment failure (OR 11.6; 95% CI 1.29-104.8). We were unable to identify any factors predicting treatment failure in CSA patients, although a Gram-negative bacillary aetiology was a protective factor. These data suggest that although conservative surgery was the only factor independently associated with treatment failure, it could be the first therapeutic choice for the management of Gram-negative bacillary and streptococcal AHPJI, and for some cases with acute S. aureus infections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction.- Knee injuries are frequent in a young and active population. Most of the patients resume their professional activity but few studies were interested in factors that predict a return to work. The aim of this study is to identify these predictors from a large panel of bio-psychosocial variables. We postulated that the return to work 3 months and 2 years after discharge is mostly predicted by psychosocial variables.Patients and methods.- Prospective study, patients hospitalized for a knee injury. Variables measured: the abbreviated injury score (AIS) for the gravity of the injuries, analog visual scale for the intensity of pain, INTERMED for the bio-psychosocial complexity, SF-36 for the quality of life, HADs for the anxiety/depression symptoms and IKDC score for the knee function. Univariate logistic regressions, adjusted for age and gender, were performed in order to predict return to work.Results.- One hundred and twenty-six patients hospitalized during 8 months after the accident were included into this prospective study. A total of 73 (58%) and 75 (59%) questionnaires were available after 3 months and 2 years, respectively. The SF-36 pain was the sole predictor of return to work at 3 months (odds Ratio 1.06 [1.02-1.10], P = 0.01; for a one point increase) and 2 years (odds Ratio 1.06 [1.02-1.10], P = 0.01). At three months, other factors are SF-36 (physic sub-scale), IKDC score, the presence of a work contract and the presence of litigation. The bio-psychosocial complexity, the presence of depressive symptoms predicts the return to work at two years.Discussion.- Our working hypothesis was partially confirmed: some psychosocial factors (i.e. depressive symptoms, work contract, litigation, INTERMED) predict the return to work but the physical health and the knee function, perceived by the patient, are also correlated. Pain is the sole factor isolated at both times (i.e. 3 months and 2 years) and, consequently, appears a key element in the prediction of the return to work. Some factors are accessible to the rehabilitation program but only if an interdisciplinary approach is performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is controversy over the use of the Ross procedure with regard to the sub-coronary and root replacement technique and its long-term durability. A systematic review of the literature may provide insight into the outcomes of these two surgical subvariants. A systematic review of reports between 1967 and February 2013 on sub-coronary and root replacement Ross procedures was undertaken. Twenty-four articles were included and divided into (i) sub-coronary technique and (ii) root replacement technique. The 10-year survival rate for a mixed-patient population in the sub-coronary procedure was 87.3% with a 95% confidence interval (CI) of 79.7-93.4 and 89.1% (95% CI, 85.3-92.1) in the root replacement technique category. For adults, it was 94 vs 95.3% (CI, 88.9-98.1) and in the paediatric series it was 90 vs 92.7% (CI, 86.9-96.0), respectively. Freedom from reoperation at 10 years was, in the mixed population, 83.3% (95% CI, 69.9-93.4) and 93.3% (95% CI, 89.4-95.9) for sub-coronary versus root replacement technique, respectively. In adults, it was 98 vs 91.2% (95% CI, 82.4-295.8), and in the paediatric series 93.3 vs 92.0% (95% CI, 86.1-96.5) for sub-coronary versus root replacement technique, respectively. The Ross procedure arguably has satisfactory results over 5 and 10 years for both adults and children. The results do not support the advantages of the sub-coronary technique over the root replacement technique. Root replacement was of benefit to patients undergoing reoperations on neoaorta and for long-term survival in mixed series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The Contegra bioprosthesis (valved heterologous bovine jugular vein) is used for reconstruction of the right ventricular outflow tract (RVOT) in congenital heart malformations and pulmonary valve replacement in different settings. Compared to pulmonary homografts, the Contegra conduit is readily available 'on the shelf'. So far, its use was mainly described in children. The aim of this study is to evaluate the feasibility and the outcome of Contegra graft implantation in the adult. METHODS: Between November 1999 and December 2007, a total of 32 Contegra grafts were implanted in 31 patients (24 men and 7 women), with a mean age of 35.7+/-10.5 years (range 18-54 years). All operations have been completed through median sternotomy with cardiopulmonary bypass. Indications included: Ross procedure for aortic valve disease (n=22); re-operation of corrected Fallot-tetralogy (n=5); isolated pulmonary valve disease (n=2); re-operation of double outlet right ventricle (DORV) (n=1); pulmonary stenosis in congenital dilated cardiomyopathy (DCM) (n=1). Conduit sizes included 22 mm (n=31), 20 mm (n=1). RESULTS: There was no hospital mortality and no valved conduit related early morbidity. In the median follow-up of 38 months (range 1-99 months) of 28 patients there was one late death, not conduit related (total mortality 3.6%). Re-operation for symptomatic graft stenosis was realised in two patients, 7 and 16 months after primo-implantation, corresponding to graft related late morbidity of 7.1%. CONCLUSIONS: In this small review of 32 operations using the Contegra graft for RVOT reconstruction in adult cardiac surgery for different indications, we observed good postoperative mid-term results concerning conduit function. Mean transpulmonary pressure gradients remain low (13.3+/-6.6 mmHg postoperative, 14.5+/-7.9 mmHg at follow-up). The use of the Contegra graft seems to be a good alternative to the homograft with low operative mortality and morbidity. Long-term outcome data are not available and further investigations must be performed to evaluate results.