1000 resultados para Ives Gandra Martins
Resumo:
OBJECTIVE: To characterize the behavior of premature newborns in the first year of chronological age. METHODS: This is a cross-sectional descriptive study, bound to a longitudinal study titled: Comparison of visual behavior on the first quarter of year of life of premature nursling born at two maternities of Recife/PE. The sample was composed by 52 premature newborns selected from June, 2007 to June, 2008 from the Maternity of the Federal University of Pernambuco (UFPE). Biological, socioeconomic and demographic data was collected through medical records and interviews with progeny. Newborns were evaluated by the Assessment Guide of Visual Ability in Infants. RESULTS: Most of the newborns were male at a gestational period between 33 weeks and 36 weeks and 6 days, showed a good visual behavior development for the age researched, and most of the families showed good socioeconomical and demographic profile. Besides, it was possible to detect ocular signs in 19% of sample, that were referred to an Ophthalmology Service. CONCLUSION: This study results point out the method like an important key in the early detection and visual screening for premature nursling since the first month of life and it led us to believe that clinical view for occupational therapy intervention must be focused not only on biological risks but also at the influence environment in newborn performance.
Resumo:
The authors analysed 34 cases of resistant epilepsy (20 males and 14 females, mean age 23 years), treated clinically between February/1984 and May/1986. The patients underwent neurological, neuropsychological, psychological, psychiatric, cerebrospinal fluid, electroencephalographic, tomographic and/or angiographic examination. Most of the patients had complex partial seizures. The etiology was unknown in 19 patients (55.8%), probable neurocysticercosis in 6, perinatal hypoxia in 5, delivery trauma in 3 and probable sequelae of encephalitis in 2 patients. There was a clear past history of infantile febrile convulsion in 2 patients. Most patients received carbamazepine (mean dose 24.5 mg/kg/day), phenytoin (5 mg/kg and valproic acid (28 mg/kg) as monotherapy or in association. Twenty-two patients (64.7%) had more than 80% decrease of the seizure frequency. Nine resistant epilepsy-cases (24.5%) were evaluated as candidates for surgical therapy. The authors concluded that the resistant epilepsy is best managed by a specialised, multidisciplinary team, and pointed out the need of a correct diagnosis of the seizure type, an adequate drug therapy and a good engagement of the patient and his family in the treatment.
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
INTRODUÇÃO: Alterações neurológicas ou sensoriais, entre elas as alterações auditivas periféricas e/ou centrais, são enfatizadas na população com baixo peso ao nascimento (BP), assim como, na presença de malformação craniofacial, tal como a fissura labiopalatina (FLP). OBJETIVO: Verificar e comparar o resultado de testes de processamento auditivo, Teste Dicótico de Dígitos (TDD) e Teste de Fusão Auditiva-Revisado (AFT-R), de crianças com FLP com e BP ao nascimento, com o de crianças sem FLP e nascida com peso normal. MÉTODO: Estudo retrospectivo e comparativo de 73 prontuários, dos quais foram verificados o sexo, peso ao nascimento, presença/ausência de FLP e o resultado de TDD e AFT-R. Foram constituídos três grupos de acordo com a análise do peso ao nascimento e presença ou ausência de FLP. RESULTADOS: Para o TDD a Análise de Covariância não mostrou diferença entre os grupos e sexos, porém a co-variável idade mostrou relação estatisticamente significante. Para o AFT-R não mostrou diferença entre os grupos, sexos e idades. CONCLUSÃO: Crianças com FLP e BP, embora sem significância estatística, apresentam maiores alterações nos testes de processamento auditivo utilizados ao comparar com crianças com FLP isolada e com crianças sem esta malformação craniofacial e sem BP. Ressalta-se ainda que o aumento da idade melhorou o desempenho no TDD.
Resumo:
In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.
Resumo:
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.
Resumo:
The biological fixation between the dental implant surfaces and jaw bones should be considered a prerequisite for the long-term success of implant-supported prostheses. In this context, the implant surface modifications gained an important and decisive place in implant research over the last years. As the most investigated topic in, it aided the development of enhanced dental treatment modalities and the expansion of dental implant use. Nowadays, a large number of implant types with a great variety of surface properties and other features are commercially available and have to be treated with caution. Although surface modifications have been shown to enhance osseointegration at early implantation times, for example, the clinician should look for research evidence before selecting a dental implant for a specific use. This paper reviews the literature on dental implant surfaces by assessing in vitro and in vivo studies to show the current perspective of implant development. The review comprises quantitative and qualitative results on the analysis of bone-implant interface using micro and nano implant surface topographies. Furthermore, the perspective of incorporating biomimetic molecules (e.g.: peptides and bone morphogenetic proteins) to the implant surface and their effects on bone formation and remodeling around implants are discussed.