998 resultados para Ising Onsager transizioni fase ferromagnetismo dualita
Resumo:
Analysis of diazepam (DZP) and its active metabolite nordiazepam (NDZP) in plasma is commonly performed in clinical medicine to ensure proper therapeutic effects while minimizing the incidence of toxicity. This study aimed to optimize analytical parameters and compare two pre-treatment techniques, liquid-liquid (LLE) and solid phase extraction (SPE), as well as liquid chromatographic conditions to analyze simultaneously DZP and NDZP in plasma from 20 patients treated with a daily dose of 10 mg. Both techniques showed to be well in line with the international criteria for analytical validation, which permitted to quantify DZP (66.2 - 1148.6 ng mL-1) and NDZP (138.5 - 808.6 ng mL -1) in all samples. The correlation coefficients between SPE and LLE were respectively 0.9729 for DZP and 0.9643 for NDZP.
Resumo:
El objetivo de este trabajo es describir detalladamente los tetrasporófitos de las especies Fauchea repens y Gloiocladia furcata y determinar si existen diferencias taxonómicas entre ellas
Resumo:
A new solid phase microextraction (SPME) system, known as in-tube SPME, was recently developed using an open tubular fused-silica capilary column, instead of an SPME fiber, as the SPME device. On-line in-tube SPME is usually used in combination with high performance liquid chromatography. Drugs in biological samples are directly extracted and concentrated in the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and then directly transferred to the liquid chromatographic column. In-tube SPME is suitable for automation. Automated sample handling procedures not only shorten the total analysis time, but also usually provide better accuracy and precision relative to manual techniques. In-tube SPME has been demonstrated to be a very effective and highly sensitive technique to determine drugs in biological samples for various purposes such as therapeutic drug monitoring, clinical toxicology, bioavailability and pharmacokinetics.
Resumo:
En el presente artículo hemos tratado de analizar las características de las almazaras cooperativas catalanas con la finalidad de destacar no solamente sus elementos más importantes de gestión sino también sus principales debilidades. Las cooperativas se consideran instrumentos útiles para acometer políticas de desarrollo económico y bienestar social. A pesar de ello hay un gran debate abierto acerca de la eficiencia de estas organizaciones, que plantean el interrogante de si están en condiciones de competir con éxito en una economía cada vez más abierta, liberalizada y global. A través de las encuestas que hemos realizado al conjunto de las cooperativas oleícolas de Catalunya, hemos podido averiguar sus características distintivas, así como las principales desventajas y problemas a los que se enfrentan. Creemos puede ser de interés analizar las características de estas organizaciones, que tanto desde el punto de vista organizativo como de recursos humanos, como financiero, las hace diferentes de otro tipo de organizaciones pero que sin embargo, han de hacer frente a un mercado cada día más exigente y competitivo
Resumo:
This paper presents an easy and practical procedure to obtain silica-based C-8 type sorbents for use in solid-phase extraction. The materials are prepared by depositing poly(methyloctylsiloxane), PMOS, on the silica support. Two different treatments for immobilization were used: thermal treatment or gamma irradiation. Suitable recoveries were obtained after pre-concentration of dilute solutions, at the ng/L level, of a mixture of pesticides, indicating the good performance of the materials.
Resumo:
A partir de una primera experiencia en el desarrollo de una aplicación interactiva multimedia, como fue la elaboración de comprimidos infantiles de paracetamol y aplicación de las Normas de Correcta Fabricación , y visto que ha tenido una gran aceptación por parte de los alumnos, se decidió el realizar una nueva aplicación interactiva multimedia que considerara la otra práctica que se realizaba en la planta piloto del SDM (Servei de Desenvolupament del Medicament), la cual consiste en la elaboración de una emulsión silicónica. Ambas prácticas se llevan a cabo presencialmente en la asignatura de Tecnología Farmacéutica II. En esta segunda aplicación multimedia, si bien se ha mantenido una estructura similar a la primera editada, se ha intentado mejorar todos aquellos aspectos que surgieron durante la programación y la fase de pruebas de dicha multimedia, como por ejemplo el más importante que ha sido el utilizar un tipo de programación que permita visualizar la actividad a través de Internet entre otras muchas mejoras. Además en esta nueva aplicación se ha introducido una actividad que consiste en un simulador de la elaboración de una emulsión en donde los alumnos podrán probar diferentes parámetros de fabricación (velocidad y tiempo de agitación) para encontrar aquellos que den unas características de viscosidad y extensión lo más óptimas posibles. A día de hoy faltan todavía algunos ajustes a dicha aplicación que se pretende ensayar en el curso académico 2004-2005 donde se valorará por parte de los alumnos y profesores su aplicabilidad y su aceptación real. En esta comunicación se presenta las áreas desarrolladas.
Resumo:
El ß LÍNH4SO4 (ß LAS) presenta dos transiciones de fase, una alrededor de 10 °C y la otra a 186 °C. La fase intermedia es ferroeléctrica. En este trabajo se estudia el efecto que produce la sustitución parcial del catión amonio por rubidio y del anión sulfato por seleniato en dichas transiciones de fase. Se establece la zona de existencia de las soluciones sólidas Li(NH4)-^_^Rb^S04 y LiNH4(SO^)^_^(Se04)^ en las que se mantiene la estructura del ß LAS. La presencia de aniones seleniato o de cationes rubidio afecta a las transiciones de fase de alta y baja temperatura, por lo que, tanto los tetraedros sulfato como el catión amonio intervienen en dichas transiciones. Hay un efecto cooperativo entre el desorden de los grupos sulfato y las distorsiones de los tetraedros amonio. El mecanismo que puede explicar estas transiciones es del tipo orden-desorden.
Resumo:
The nonequilibrium phase transitions occurring in a fast-ionic-conductor model and in a reaction-diffusion Ising model are studied by Monte Carlo finite-size scaling to reveal nonclassical critical behavior; our results are compared with those in related models.
Resumo:
The properties of water can have a strong dependence on the confinement. Here, we consider a water monolayer nanoconfined between hydrophobic parallel walls under conditions that prevent its crystallization. We investigate, by simulations of a many-body coarse-grained water model, how the properties of the liquid are affected by the confinement. We show, by studying the response functions and the correlation length and by performing finite-size scaling of the appropriate order parameter, that at low temperature the monolayer undergoes a liquid-liquid phase transition ending in a critical point in the universality class of the two-dimensional (2D) Ising model. Surprisingly, by reducing the linear size L of the walls, keeping the walls separation h constant, we find a 2D-3D crossover for the universality class of the liquid-liquid critical point for L/h=~50, i.e. for a monolayer thickness that is small compared to its extension. This result is drastically different from what is reported for simple liquids, where the crossover occurs for , and is consistent with experimental results and atomistic simulations. We shed light on these findings showing that they are a consequence of the strong cooperativity and the low coordination number of the hydrogen bond network that characterizes water.
Resumo:
Polycyclic aromatic hydrocarbons (PAHs) are a great environmental concern mainly because of their toxic, mutagenic and carcinogenic potential. This paper reports utilization of the solid-phase extraction (SPE) technique to determine PAHs in environmental aqueous matrices. The recovery from environmental aqueous matrices fortified with PAHs varied from 63.7 to 93.1% for atmospheric liquid precipitation, from 38.3 to 95.1% for superficial river water, and from 71.0 to 95.5% for marine water. No negative matrix effect was observed for the recovery of PAHs from atmospheric liquid precipitation and marine water, but was observed for superficial river water, particularly for PAHs possessing 5 and 6 aromatic rings.
Resumo:
In this study a new approach, solid phase micro extraction (SPME), is used in the evaluation of the infinite dilution activity coefficient of the solute in a given solvent. It is the purpose of the current work to demonstrate a different approach to obtain the data needed for studying the solution thermodynamics of binary liquid mixtures as well as for designing multi-component separations. The solutes investigated at the temperature 298.15 K were toluene, ethyl benzene and xylene in the solvent methanol.
Resumo:
Chromatography is a means of separating mixtures into their several components. TLC, mainly a liquid/solid process, is one of the separation techniques most often used. It is indispensable in laboratories dealing with natural products, organic and analytical chemistry. Commercial chromatography plates are offered at relatively high cost. In this work the construction of a hand-operated plate coater of stationary phases of low cost and good reproducibility is described to be used in teaching laboratories and research.
Resumo:
A method for determining copper by solid phase spectrophotometry (SPS) was optimized using the Doehlert design. Copper(II) was sorbed on a styrene-divinylbenzene anion-exchange resin as a Cu(II)-1-(2-pyridylazo)-2-naphthol (PAN) complex, at pH 7.0. Resin phase absorbances at 560 and 800 nm were measured directly. The detection limit was found to be 2.5 µg L-1. The relative standard deviation on ten replicate determinations of 10 µg Cu(II) in 1000 mL samples was 1.1%. The linear range of the determination was 5.0-100 µg L-1. The method was applied successfully to the determination of Cu(II) in natural water and vegetable samples.
Resumo:
Aquest treball és la culminació de les pràctiques realitzades al sincrotró ALBA. Situat a Cerdanyola del Vallès, ALBA és un accelerador de 3a generació que permet emmagatzemar un feix d'electrons confinat de fins a 400 mA a 3GeV d'energia, amb l'objectiu d'obtenir llum a partir dels girs provocats al feix. Els sincrotrons moderns com el d'ALBA, el que pretenen és aconseguir un major control i estabilitat de la llum. Per aconseguir-ho, cal que el feix d'electrons que creen la llum estigui controlat al màxim i la seva òrbita sigui estable. Amb aquest objectiu els sincrotrons estant implementant sistemes de Fast Orbit FeedBack (FOFB) o sistemes realimentats de correcció ràpida de l'òrbita, per realitzar correccions d'almenys 100Hz que estabilitzin el feix d'electrons amb menys d'un 10% de l'amplada del feix (5-10μm). El treball exposa el desenvolupament d'una part del sistema de correcció ràpida de l'òrbita dels electrons (FOFB) que s'està duent a terme al sincrotró ALBA. Concretament, s’han revisat els estudis previs realitzats durant la fase de disseny del sincrotró, s’han recalculat funcions de transferència i retards de tots els elements involucrats al sistema. També s’han realitzat simulacions per confirmar la viabilitat del sistema amb les noves dades i finalment s’ha desenvolupat part de la unitat de control determinant el Hardware i s'ha adquirit dades que permetran analitzar el soroll de l'òrbita que en futurs treballs determinaran millor l'algorisme de la unitat de control.