289 resultados para Ionisation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work metal - Microwave Plasma CVD diamond Schottky devices were studied. The current density vs. applied voltage reveals rectification ratios up to 10(4) at \ +/- 2V \. Under illumination an inversion and increase of the rectification is observed. The carrier density is 10(15) cm(-3) and the ideality factors near 1.5. The dark current vs. temperature shows that below 150 K the bulk transport is controlled by a hopping process with a density of defects of 10(16) cm(-3). For higher temperatures an extrinsic ionisation with activation energy of 0.3 eV takes place. The correlation with the polycrystalline nature of the samples is focused.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work metal - Microwave Plasma CVD diamond Schottky devices were studied. The current density vs. applied voltage reveals rectification ratios up to 10(4) at \ +/- 2V \. Under illumination an inversion and increase of the rectification is observed. The carrier density is 10(15) cm(-3) and the ideality factors near 1.5. The dark current vs. temperature shows that below 150 K the bulk transport is controlled by a hopping process with a density of defects of 10(16) cm(-3). For higher temperatures an extrinsic ionisation with activation energy of 0.3 eV takes place. The correlation with the polycrystalline nature of the samples is focused.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple method for tracing carbon fixation and lipid synthesis in microalgae was developed using a combination of solid-phase extraction (SPE) and negative ion chemical ionisation gas chromatography mass spectrometry (NCI-GC-MS). NCI-GC-MS is an extremely sensitive technique that can produce an unfragmented molecular ion making this technique particularly useful for stable isotope enrichment studies. Derivatisation of fatty acids using pentafluorobenzyl bromide (PFBBr) allows the coupling of the high separation efficiency of GC and the measurement of unfragmented molecular ions for each of the fatty acids by single quadrupole MS. The key is that isotope spectra can be measured without interference from co-eluting fatty acids or other molecules. Pre-fractionation of lipid extracts by SPE allows the measurement of13C isotope incorporation into the three main lipid classes (phospholipids, glycolipids, neutral lipids) in microalgae thus allowing the study of complex lipid biochemistry using relatively straightforward analytical technology. The high selectivity of GC is necessary as it allows the collection of mass spectra for individual fatty acids, including cis/trans isomers, of the PFB-derivatised fatty acids. The combination of solid-phase extraction and GC-MS enables the accurate determination of13C incorporation into each lipid pool. Three solvent extraction protocols that are commonly used in lipidomics were also evaluated and are described here with regard to extraction efficiencies for lipid analysis in microalgae.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: La rápida detección e identificación bacteriana es fundamental para el manejo de los pacientes críticos que presentan una patología infecciosa, esto requiere de métodos rápidos para el inicio de un correcto tratamiento. En Colombia se usan pruebas microbiología convencional. No hay estudios de espectrofotometría de masas en análisis de muestras de pacientes críticos en Colombia. Objetivo general: Describir la experiencia del análisis microbiológico mediante la tecnología MALDI-TOF MS en muestras tomadas en la Fundación Santa Fe de Bogotá. Materiales y Métodos: Entre junio y julio de 2013, se analizaron 147 aislamientos bacterianos de muestras clínicas, las cuales fueron procesadas previamente por medio del sistema VITEK II. Los aislamientos correspondieron a 88 hemocultivos (60%), 28 urocultivos (19%), y otros cultivos 31 (21%). Resultados: Se obtuvieron 147 aislamientos con identificación adecuada a nivel de género y/o especie así: en el 88.4% (130 muestras) a nivel de género y especie, con una concordancia del 100% comparado con el sistema VITEK II. El porcentaje de identificación fue de 66% en el grupo de bacilos gram negativos no fermentadores, 96% en enterobacterias, 100% en gérmenes fastidiosos, 92% en cocos gram positivos, 100% bacilos gram negativos móviles y 100% en levaduras. No se encontró ninguna concordancia en bacilos gram positivos y gérmenes del genero Aggregatibacter. Conclusiones: El MALDI-TOF es una prueba rápida para la identificación microbiológica de género y especie que concuerda con los resultados obtenidos de manera convencional. Faltan estudios para hacer del MALDI-TOF MS la prueba oro en identificación de gérmenes.