994 resultados para Internal resonance
Resumo:
A versatile and flexible digital pulse programmer for two-pulse, three-pulse, saturation burst and Carr-Purcell sequences is described. Independently variable controls for pulse widths (0.2 mu s to 100 mu s), delay between pulses (0.2 mu s to 100 s) and for number of pulses (1 to 99) for the saturation burst and for the Carr-Purcell sequence, are brought to the front panel. The programmer can be used for one-shot experiments as well as for repetitive experiments.
Resumo:
Dielectric studies of the glassy crystalline states of cyclohexanol, cyclohexanone, and camphor obtained by upercooling the plastic crystalline phase demonstrate the presence of characteristic a- and p-relaxations. The parameters of the a-relaxation fit the Vogel-Tammann-Fulcher (VTF) equation. ESR spin-probe studies of the glassy crystalline phase of cyclohexanol show that there is a marked decrease in the correlation time above the glasslike transition temperature. The present studies suggest the similarity between glassy crystals having long-range orientational disorder and glasses which are known to betra nslationally disordered.
Resumo:
THE COMPLEXES of pyridine-l-oxide and 2- and 4-substituted pyridine-l-oxides have been investigated previously[l]. The complexes of 3-substituted pyfidine-l-oxides, however, have received little attention. The rare-earth complexes of pyridine-Ioxide[l, 2], 4-methylpyridine- l-oxide [1] and 2,6- dimethylpyfidine-l-oxide[3,4] have been reported earlier. The present paper deals with the isolation and characterisation of 3-methylpyridine-l-oxide (3-Picoline-N-oxide, 3-PicNO) complexes with rare-earth perchlorates.
Resumo:
FMR measurements have been carried out on several members of the Ln1âxSrxCoO3 (Ln = Rare earth) system. The results show that geff in these systems is around 1.25 independent of x as well as the rare earth ion. It is suggested that this unusual value of geff is due to the localized intermediate-spin Co3+ ions (t52ge1g) located at the top of the Ï* band.
Resumo:
Abstract is not available.
Resumo:
Jacalin [Artocarpus integrifolia (jack fruit) agglutinin] is made up of two types of chains, heavy and light, with M(r) values of 16,200 +/- 1200 and 2090 +/- 300 respectively (on the basis of gel-permeation chromatography under denaturing conditions). Its complete amino acid sequence was determined by manual degradation using a 4-dimethylaminoazobenzene 4'-isothiocyanate double-coupling method. Peptide fragments for sequence analysis were obtained by chemical cleavages of the heavy chain with CNBr, hydroxylamine hydrochloride and iodosobenzoic acid and enzymic cleavage with Staphylococcus aureus proteinase. The peptides were purified by a combination gel-permeation and reverse-phase chromatography. The light chains, being only 20 residues long, could be sequenced without fragmentation. Amino acid analyses and carboxypeptidase-Y-digestion C-terminal analyses of the subunits provided supportive evidence for their sequence. Computer-assisted alignment of the jacalin heavy-chain sequence failed to show sequence similarity to that of any lectin for which the complete sequence is known. Analyses of the sequence showed the presence of an internal repeat spanning residues 7-64 and 76-130. The internal repeat was found to be statistically significant.
Resumo:
The unconfined aquifer of the Continental Terminal in Niger was investigated by magnetic resonance sounding (MRS) and by 14 pumping tests in order to improve calibration of MRS outputs at field scale. The reliability of the standard relationship used for estimating aquifer transmissivity by MRS was checked; it was found that the parametric factor can be estimated with an uncertainty a parts per thousand currency sign150% by a single point of calibration. The MRS water content (theta (MRS)) was shown to be positively correlated with the specific yield (Sy), and theta (MRS) always displayed higher values than Sy. A conceptual model was subsequently developed, based on estimated changes of the total porosity, Sy, and the specific retention Sr as a function of the median grain size. The resulting relationship between theta (MRS) and Sy showed a reasonably good fit with the experimental dataset, considering the inherent heterogeneity of the aquifer matrix (residual error is similar to 60%). Interpreted in terms of aquifer parameters, MRS data suggest a log-normal distribution of the permeability and a one-sided Gaussian distribution of Sy. These results demonstrate the efficiency of the MRS method for fast and low-cost prospection of hydraulic parameters for large unconfined aquifers.
Resumo:
In recent years, identification of sequence patterns has been given immense importance to understand better their significance with respect to genomic organization and evolutionary processes. To this end, an algorithm has been derived to identify all similar sequence repeats present in a protein sequence. The proposed algorithm is useful to correlate the three-dimensional structure of various similar sequence repeats available in the Protein Data Bank against the same sequence repeats present in other databases like SWISS-PROT, PIR and Genome databases.
Resumo:
A Caucasian male aged 15 years presented with 2 years accelerated linear growth. He was 202 cm tall at presentation, with calculated mid-parental height of 173 cm. There were no features of hypopituitarism or acral growth. His visual fields and optic discs were normal...
Resumo:
Deviations from the usual R (-6) dependence of the rate of fluorescence resonance energy transfer (FRET) on the distance between the donor and the acceptor have been a common scenario in the recent times. In this paper, we present a critical analysis of the distance dependence of FRET, and try to illustrate the non R (-6) type behaviour of the rate for the case of transfer from a localized electronic excitation on the donor, a dye molecule to three different energy acceptors with delocalized electronic excitations namely, graphene,two-dimensional semiconducting sheet and the case of such a semiconducting sheet rolled to obtain a nanotube. We use simple analytic models to understand the distance dependence in each case.
Resumo:
The rupture of a cerebral artery aneurysm causes a devastating subarachnoid hemorrhage (SAH), with a mortality of almost 50% during the first month. Each year, 8-11/100 000 people suffer from aneurysmal SAH in Western countries, but the number is twice as high in Finland and Japan. The disease is most common among those of working age, the mean age at rupture being 50-55 years. Unruptured cerebral aneurysms are found in 2-6% of the population, but knowledge about the true risk of rupture is limited. The vast majority of aneurysms should be considered rupture-prone, and treatment for these patients is warranted. Both unruptured and ruptured aneurysms can be treated by either microsurgical clipping or endovascular embolization. In a standard microsurgical procedure, the neck of the aneurysm is closed by a metal clip, sealing off the aneurysm from the circulation. Endovascular embolization is performed by packing the aneurysm from the inside of the vessel lumen with detachable platinum coils. Coiling is associated with slightly lower morbidity and mortality than microsurgery, but the long-term results of microsurgically treated aneurysms are better. Endovascular treatment methods are constantly being developed further in order to achieve better long-term results. New coils and novel embolic agents need to be tested in a variety of animal models before they can be used in humans. In this study, we developed an experimental rat aneurysm model and showed its suitability for testing endovascular devices. We optimized noninvasive MRI sequences at 4.7 Tesla for follow-up of coiled experimental aneurysms and for volumetric measurement of aneurysm neck remnants. We used this model to compare platinum coils with polyglycolic-polylactic acid (PGLA) -coated coils, and showed the benefits of the latter in this model. The experimental aneurysm model and the imaging methods also gave insight into the mechanisms involved in aneurysm formation, and the model can be used in the development of novel imaging techniques. This model is affordable, easily reproducible, reliable, and suitable for MRI follow-up. It is also suitable for endovascular treatment, and it evades spontaneous occlusion.