959 resultados para Intermittent catheter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supervised exercise training has been shown to improve walking capacity in several studies of patients with intermittent claudication. However, data on long-term outcome are quite limited. The aim of this prospective study was to evaluate long-term effects of supervised exercise training on walking capacity and quality of life in patients with intermittent claudication. Patients and methods: Sixty-seven consecutive patients with intermittent claudication who completed a supervised 12-week exercise training program were asked for follow up evaluation 39 +/- 20 months after program completion. Pain-free walking distance (PWD) and maximum walking distances (MWD) were assessed by treadmill test and several questionnaires. Results: Forty (60%) patients agreed to participate, 22 (33%) refused participation, and 5 (7%) died during follow-up. PWD and MWD significantly improved at completion of 12-weeks supervised exercise training as compared to baseline (PWD 114 +/- 100 vs. 235 +/- 248, p = 0.002; MWD 297 +/- 273 vs. 474 +/- 359, p = 0.001). Improvement of PWD and MWD could be maintained at follow up (197 +/- 254, p = 0.014; 390 +/- 324, p = 0.035, respectively) with non-smokers showing significantly better sustained PWD and MWD improvement as compared to baseline. Overall, walking capacity correlated with functional status of quality of life. Conclusions: Major findings of this investigation were that improvement in walking capacity is sustained after completion of supervised exercise training program with best results in patients who quitted or never smoked. Improved walking capacity is associated with increased functional status of quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To clarify the role of the pulmonary artery catheter in the intensive care unit. DATA SOURCES: Recent and relevant literature from MEDLINE and authors' personal databases. STUDY SELECTION: Studies on pulmonary artery catheter use and use of other monitoring devices in critically ill patients. DATA EXTRACTION: Based largely on clinical experience and assessment of the relevant published literature and in response to recent articles attacking the pulmonary artery catheter, we propose that the pulmonary artery catheter is still a valuable tool for the hemodynamic monitoring of patients with complex disease processes in whom the information obtained from the pulmonary artery catheter may influence management. We suggest that there is a need to revisit the basics of hemodynamic management and reassess the way in which the pulmonary artery catheter is used, applying three key principles: correct measurement, correct data interpretation, and correct application. CONCLUSION: The pulmonary artery catheter is still a valuable tool for hemodynamic monitoring when used in selected patients and by physicians adequately trained to correctly interpret and apply the data provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: In male patients with ileal bladder substitute we ascertained the likelihood of spontaneous voiding failure, the corrective procedures required and the eventual outcomes. MATERIALS AND METHODS: Following cystectomy and ileal bladder substitution for urothelial cancer between April 1985 and September 2002 male patients were identified and analyzed from the prospective departmental database. Four patients underwent ileum conduit conversion following urethral recurrence or pouch necrosis and were excluded from study. Funnel-shaped outlets were avoided during bladder substitute surgery after the first 4 patients with this configuration experienced voiding failure and required corrective procedures. Only patients with a minimum 5-year followup were assessed for voiding failure, corrective procedures and final outcomes. RESULTS: Of 354 patients with a median age of 65 years (range 36 to 84) treated with bladder substitute 180 (51%) were alive at 5 years. All 180 of these patients spontaneously voided within 3 months of surgery. During this 5-year observation period 22 (12%) patients experienced voiding problems requiring de-obstructive procedures. Following intervention 177 (98%) patients were spontaneously voiding by 5 years. Of 237 patients 77 (32%) were alive at 10 years. Of these 77 patients followed for another 5 years 10 (13%) had similar voiding problems requiring de-obstructive procedures. Subsequently 74 (96%) were voiding spontaneously by 10 years. CONCLUSIONS: Patients often fail to void spontaneously after ileal bladder substitution. However, if a funnel-shaped outlet is avoided and de-obstructive surgery is appropriately implemented, excellent long-term results are seen with spontaneous voiding and clean intermittent catheterization can be avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Currently, only anecdotal information exists on the presentation and outcome of coronary arterial injury after ablation procedures. METHODS AND RESULTS: Four patients who sustained coronary artery injury of a cohort of patients undergoing 4655 consecutive ablation procedures (0.09%) are described. The patients' mean age was 45+/-11 years, and 1.8+/-0.5 prior ablation attempts had been unsuccessful. Coronary injury occurred from epicardial ventricular tachycardia ablation in 2 patients (irrigated radiofrequency ablation in one and cryoablation in the other) and ablation within the middle cardiac vein with irrigated radiofrequency in 2 patients. All involved branches of the right coronary artery. Acute occlusion presenting with ST-segment elevation immediately after ablation was recognized during the procedure in 2 cases. Occlusion failed to respond to nitroglycerin or balloon dilation, and stenting was required in both cases. Acute myocardial infarction occurred 2 weeks after epicardial ablation as a result of occlusion of a right ventricular branch of the right coronary artery giving rise to the posterior descending coronary artery in 1 patient. A moderate asymptomatic stenosis was seen on angiography after epicardial cryoablation in 1 patient. All patients recovered and remained asymptomatic from the coronary injury and arrhythmias during 37+/-53 months of follow-up. CONCLUSIONS: Coronary arterial injury after ablation procedures is rare. It may present acutely or several weeks after an ablation procedure. Acute occlusion appears to require coronary stenting. Unanticipated anatomic variations can predispose to coronary injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interventional cardiology in a day-case setting might reduce logistic constraints on hospital resources. However, in contrast with coronary angioplasty, few data support the feasibility and safety of radiofrequency catheter ablation (RCA). The aim of this prospective, multicenter cohort study was to evaluate the feasibility and safety of RCA in 1,342 patients (814 men; mean age 57 +/- 17 years) considered eligible for ambulatory RCA, according to specific set of criteria, for common atrial flutter (n = 632), atrioventricular nodal reentrant tachycardia (n = 436), accessory pathways (n = 202), and atrial tachycardia (n = 72). Patients suitable for early discharge (4 to 6 hours after uncomplicated RCA) were scheduled for 1-month follow-up. Predictive factors for delayed complications were studied by multivariate analysis. Of the 1,342 enrolled patients, 1,270 (94.6%) were discharged the same day and followed for 1 month; no deaths occurred, and the readmission rate was 0.79% (95% confidence interval 0.30% to 1.27%). Six patients had significant puncture complications, 2 presented with symptomatic delayed pulmonary embolism, and 2 had new onset of poorly tolerated atrial flutter. None of these complications was life threatening. Multivariate analysis did not identify any significant independent predictors for delayed complications. In conclusion, these data suggest that same-day discharge after uncomplicated RCA for routine supraventricular arrhythmias is safe and may be applicable in clinical practice. This approach is known to be associated with significant patient satisfaction and cost savings and can be considered a first-line option in most patients who undergo routine ablation procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To report the application of a true lumen re-entry device in the bailout treatment of chronic total occlusions (CTO) of the superficial femoral artery (SFA) after failed angioplasty. METHODS: Nineteen patients (12 men; mean age 81 years, range 61-97) with 20 SFA CTOs and Rutherford category 2 to 5 ischemia were prospectively evaluated. All CTOs had unsuccessful recanalization using conventional techniques and were subsequently treated with the Outback LTD catheter. Follow-up at 3, 6, and 12 months included ankle/toe pressure measurement and pulse volume recordings. Endpoints were revascularization rate, target lesion revascularization, and limb salvage. RESULTS: Revascularization was achieved in 95% of the cases. There were 2 (10%) periprocedural complications unrelated to the re-entry device, which were resolved by endovascular or surgical treatment. The target lesion revascularization rate was 10%, with the 2 events occurring at 3 and 6 months, respectively, in patients with Rutherford category 4-5 ischemia. There was one below-the-knee amputation in the patient with failed revascularization. CONCLUSION: The acute failure of endovascular treatment of SFA CTOs is most often due to an inability to re-enter the true lumen after the occlusion is crossed in a subintimal plane. Bailout revascularization with the Outback LTD catheter is highly successful and shows a low device-related complication rate. This needle- and fluoroscopic-based re-entry device increases the endovascular success rate and is therefore expanding the minimally invasive treatment options for surgically unfit patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the hypothesis that the need for clean intermittent self-catheterization after botulinum neurotoxin type A injections is outweighed by the efficacy of this treatment, so that clean intermittent self-catheterization is not a burden for patients with refractory idiopathic detrusor overactivity. METHODS: Women undergoing intradetrusor injections of 200 units botulinum neurotoxin type A for refractory idiopathic detrusor overactivity were evaluated prospectively. Clean intermittent self-catheterization was discussed with all patients and its possible need after botulinum neurotoxin type A treatment. As indicator of quality of life, lower urinary tract symptom distress and effect on daily activities were assessed using the validated Urogenital Distress Inventory (UDI-6) and Incontinence Impact Questionnaire (IIQ-7) before and 4 weeks after receiving botulinum neurotoxin type A injections. RESULTS: Mean age of the 65 women was 51 years, and all voided spontaneously before botulinum neurotoxin type A injections. After botulinum neurotoxin type A treatment, 28 (43%) required clean intermittent self-catheterization. Mean UDI-6 and IIQ-7 scores reduced from 61 to 33 (P<.001) and 62 to 30 (P<.001) in women performing clean intermittent self-catheterization and from 60 to 28 (P<.001) and 64 to 25 (P<.001) in those who did not, respectively. Comparison of quality of life in women performing clean intermittent self-catheterization and in those who did not revealed no significant differences before and after botulinum neurotoxin type A treatment. CONCLUSION: Clean intermittent self-catheterization after botulinum neurotoxin type A intradetrusor injections did not impair quality of life in appropriately informed and selected women in the short term. All patients should be informed of the potential need for clean intermittent self-catheterization after botulinum neurotoxin type A injections, and a willingness to do so should be a prerequisite for this still unlicensed off-label treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To assess patients' perception of clean intermittent self-catheterization (CISC) for voiding dysfunction. PATIENTS AND METHODS: A total of 101 patients performing CISC because of voiding dysfunction were invited to participate in this questionnaire survey. The response rate was 91% (92/101). RESULTS: The mean time over which CISC was performed was 5 years (standard deviation (SD) +/- 6.3) and the mean frequency of CISC per day was three times (SD +/- 2). Almost 80% (72/92) of the patients perceived CISC as easy or very easy and CISC did not interfere at all or interfered a little bit with work or other regular daily activities in more than 80% (76/92). Almost 90% (80/92) reported no or minimal pain while performing CISC. This did not interfere at all or interfered a little bit with work or other regular daily activities in almost 90% (80/92). Quality of life improved considerably due to CISC in more than 60% (56/92) and 12% (11/92) complained of a deterioration. In multivariable analysis, severe pain performing CISC (odds ratio 20.9, 95% confidence interval 1.7-259.9, P = 0.018) was the only factor that predicted poor quality of life. CONCLUSIONS: The majority of patients considered CISC to be an easy and painless procedure which did not interfere with daily activities. Consequently, quality of life improved in more than 60% of the patients. Therefore, CISC does not appear to be a burden for the patient and, from a patient's perspective, can be recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.