973 resultados para Implant-retained prostheses
Resumo:
PURPOSE: To describe a case with bullous keratopathy and anterior segment inflammation associated with heavy liquids. DESIGN: Observational case report. METHODS: Review of clinical and histopathologic changes. RESULTS: A 65-year-old patient underwent a pars plana vitrectomy for a rhegmatogenous retinal detachment. Perfluorodecalin was used as a temporary retinal tamponade. After surgery, bubbles of heavy liquid were noted in the anterior chamber. Fifteen months later, severe corneal edema developed, associated with corneal vascularization and keratic precipitates. Removal of heavy liquid through a paracentesis was attempted but the cornea remained edematous, and a penetrating keratoplasty was performed. In the histopathologic examination inflammatory changes from retention of perfluorodecalin were observed. There was a decompensated cornea with florid bullous keratopathy, inflammatory infiltration with vascularization, and deposition of perfluorodecalin within keratocytes and perivascular macrophages. CONCLUSION: Presence of heavy liquids in the anterior chamber may be associated with an intense inflammatory response and corneal decompensation. © 2005 by Elsevier Inc. All rights reserved.
Resumo:
Porous titanium samples were manufactured using the 3D printing and sintering method in order to determine the effects of final sintering temperature on morphology and mechanical properties. Cylindrical samples were printed and split into groups according to a final sintering temperature (FST). Irregular geometry samples were also printed and split into groups according to their FST. The cylindrical samples were used to determine part shrinkage, in compressive tests to provide stress-strain data, in microCT scans to provide internal morphology data and for optical microscopy to determine surface morphology. All of the samples were used in microhardness testing to establish the hardness. Below 1100 C FST, shrinkage was in the region of 20% but increased to approximately 30% by a FST of 1300 C. Porosity varied from a maximum of approximately 65% at the surface to the region of 30% internally. Between 97 and 99% of the internal porosity is interconnected. Average pore size varied between 24 µm at the surface and 19 µm internally. Sample hardness increased to in excess of 300 HV0.05 with increasing FST while samples with an FST of below 1250 C produced an elastic-brittle stress/strain curve and samples above this displayed elastic-plastic behaviour. Yield strength increased significantly through the range of sintering temperatures while the Young's modulus remained fairly consistent. © 2013 Elsevier B.V.
Resumo:
OBJECTIVE:
This study aimed to investigate antimicrobial treatment of an infected cochlear implant, undertaken in an attempt to salvage the infected device.
METHODS:
We used the broth microdilution method to assess the susceptibility of meticillin-sensitive Staphylococcus aureus isolate, cultured from an infected cochlear implant, to common antimicrobial agents as well as to novel agents such as tea tree oil. To better simulate in vivo conditions, where bacteria grow as microcolonies encased in glycocalyx, the bactericidal activity of selected antimicrobial agents against the isolate growing in biofilm were also compared.
RESULTS:
When grown planktonically, the S aureus isolate was susceptible to 17 of the 18 antimicrobials tested. However, when grown in biofilm, it was resistant to all conventional antimicrobials. In contrast, 5 per cent tea tree oil completely eradicated the biofilm following exposure for 1 hour.
CONCLUSION:
Treatment of infected cochlear implants with novel agents such as tea tree oil could significantly improve salvage outcome.
Resumo:
Introduction: Immediate reconstruction following mastectomy for breast cancer has been shown to be oncologically safe and associated with improved psychosocial outcomes for patients. Bostwick described a technique for one-stage implant based reconstruction, combining skin-sparing mastectomy with concurrent reduction of the skin envelope. This report reviews the experience of a single centre using skin-reducing mastectomy and one-stage implant reconstruction in both early stage breast cancer and risk-reducing mastectomy, with specific reference to frequency of complications, implant loss and oncological outcomes.
Methods and results: A retrospective review was undertaken to identify women who had undergone skin-reducing mastectomy and one-stage implant reconstruction using a de-epithelialised dermal flap, between October 2008 and October 2012. One hundred and four consecutive mastectomies, with reconstruction, were performed by two surgeons on 64 patients. No complications were seen in 43.8% of patients. At three months, four implants were lost (3.8% of breast reconstructions, 6.3% of patients), due to either peri-implant infection or mastectomy skin flap necrosis. One patient required unplanned return to theatre for evacuation of a haematoma. Minor mastectomy skin flap necrosis was seen in 10 breasts (9.6% of reconstructed breasts) and superficial wound infection in 8 breasts (7.7% of reconstructed breasts). All of these complications were managed conservatively and none required operative intervention. At a median follow up of 35 months (4-53 months) there had been one episode of ipsilateral axillary nodal recurrence.
Conclusion: One-stage implant reconstruction using a myo-dermal flap technique following skin-reducing mastectomy is safe and should be considered in selected patients. Most complications are minor and will resolve with conservative management. Major complications such as implant failure or immediate reoperation, were relatively uncommon (6.3% patients, 3.8% of reconstructed breasts). Early follow-up suggests that oncological outcomes are satisfactory, but longer follow-up is required to substantiate this. (C) 2013 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Resumo:
Breast augmentation for cosmetic purposes is an increasingly common procedure in the USA and UK. In the USA in 2003, a total of 254 140 breast augmentation procedures were carried out [American Society of Plastic Surgeons, http://www.plasticsurgery.org/newsroom/ Procedural-Statistics-Press-Kit-Index.cfm9-1-2005; 2006.(1)]. It has been previously estimated that between 1 and 1.5 million women in the USA have prosthetic breast implants [Cook RR, Delongchamp RR, Woodbury M, et at. The prevalence of women with breast implants in the United States, 1989. J Clin Epidemiol 1995;48:519-25.(2)]. The UK National Breast Implant Registry has recorded a rise in the numbers of women receiving breast implants, with over 13 000 procedures registered in 2001; an estimated 77% of these were for cosmetic purposes. No association has been found between the presence of breast implants in a breast and an increased risk of breast cancer, and this subject has been comprehensively reviewed elsewhere [Hoshaw SJ, Klein PJ, Clark BD, et al. Breast implants and cancer: causation, delayed detection, and survival. Plast Reconstr Surg 2001; 107:1393-407.(3)]. However, as the population of women with breast implants ages, an increasing number of them will develop breast cancer; a reflection of the fact that the incidence of the disease increases with increasing age. Debate continues on the effect of breast implants on the efficacy of mammography in diagnosing breast cancer, and the role of other imaging techniques for this purpose, as well as the limitations that the presence of implants place on percutaneous biopsy techniques. We review the Literature on the radiological and tissue diagnosis of breast cancer in women with a history of previous augmentation mammaplasty. (c) 2007 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.