998 resultados para Image statistics
Resumo:
The Institute of Public Health in Ireland (IPH) is an all-island body which aims to improve health in Ireland, by working to combat health inequalities and influence public policies in favour of health. IPH promotes co-operation in research, training, information and policy in order to contribute to policies which tackle inequalities in health. Over the past ten years IPH has worked closely with the Department of Health and Children and the Department of Health, Social Services and Public Safety in Northern Ireland to build capacity for public health across the island of Ireland. Key pointsIPH welcomes the opportunity to contribute to the questionnaire content for the 2011 Census of Population. We are particularly interested in how information collected by the Census can contribute to improved health and in this regard are broadly supportive of the questions addressing health in the current Census questionnaire. We feel that an additional question that assesses self-perceived health would be extremely useful as, while this is a subjective assessment, it has been shown to correlate well with actual health status and use of health services.
Resumo:
2008/09 Pre-Release Access List
Resumo:
Annual Reports and Deprivation Maps
Resumo:
Statistics of Scientific Procedures on Living Animals NI 2005
Resumo:
Volume 1: Programme of Care
Resumo:
The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.