974 resultados para IONIZING RADIATION
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course
Resumo:
This paper consists in the evaluation of the exposure rate to ionizing radiation to which professionals working in surgical procedures which require radiological examinations are subjected. Were initially performed real-time readings of exposure rate within four distinct operating rooms during the execution of four surgical procedures that made use of fluoroscopy equipment (including three orthopedic surgeries, one in the shoulder, one in the arm, another for deployment of metal pin in the leg region, and a fourth for vascular procedure); in these surgeries were used ionization chamber detector and an electrometer. In order to check the values achieved, was made a re-evaluation of the distribution of the rate of exposure to radiation, from the surgical procedures, now with thermoluminescent dosimeters (TLDs). For this, thirty TLDs were distributed in the operating rooms, arranged in points of interest as occupation by professionals. The TLDs were prepared for thirty consecutive days, after which they were removed and replaced with new dosimeters not exposed yet. The dosimeters were subjected to reading of the rate of exposure; this procedure was repeated for four months without interruption. The quantification of the results sought primarily to convert the rate of exposure for equivalent dose rate, both in measurements with ionization chamber as in measurements with TLDs, in order to highlight the presence of the biological effect of ionizing radiation for comparisons within scientific context. Then, the results were plotted to establish the relationship between the values of equivalent dose and the distance to the central axis of the x -ray source, confirming the inverse square law for distance. Finally, the values were associated with the maximum limit recommended by the legislation for occupationally exposed individuals. The methodology for the analysis and quantification of the data in this work aims at implementing a work plan that meets ...
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciências Biológicas (Genética) - IBB
Resumo:
Nuclear Medicine is a medical modality of therapy and diagnostic imaging using unsealed radioactive sources for its purposes. This routine activity promotes the transit of radioactive sources for the area of installation, beyond the transit of patients injected with radioisotope, which also contribute to raising the radiometric level of environment. As a consequence, it has exposured workers and public individuals to the ionizing radiation. There are protective mechanisms of radiation exposure, personal protective equipments, and measurement planes established in standard measurement at certain points of the environment in order to identify any increase in radiometric levels and \ or contamination, but do not cover the entire space occupied by workers and patients. To accomplish with the individual dose limits established by the National Commission of Nuclear Energy, it is interesting if there is an individualized classification for each Nuclear Medicine service. This work aimed to promote an analysis of the radiometric level distribution across the extent of the Technical Nuclear Medicine Sector of Hospital of the Botucatu Medical School, and produce a spatial map to identify locations with higher exposure rate to the ionizing radiation, can be used as a risk map to assist the Occupationally Exposed Individuals (IOE). To perform the radiometric levels checking it was used a digital Geiger-Muller detector available in the sector, due to its practicality compared to other detectors. Measurements were carried out at four different times for all days of the week, at points strategically established to cover all the installation
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Biociências e Biotecnologia Aplicadas à Farmácia - FCFAR
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Head and neck cancer (HNC) is the sixth most common human malignancy worldwide. The main forms of treatment for HNC are surgery, radiotherapy (RT) and chemotherapy (CT). However, the choice of therapy depends on the tumor staging and approaches, which are aimed at organ preservation. Because of systemic RT and CT genotoxicity, one of the important side effects is a secondary cancer that can result from the activity of radiation and antineoplastic drugs on healthy cells. Ionizing radiation can affect the DNA, causing single and double-strand breaks, DNA-protein crosslinks and oxidative damage. The severity of radiotoxicity can be directly associated with the radiation dosimetry and the dose-volume differences. Regarding CT, cisplatin is still the standard protocol for the treatment of squamous cell carcinoma, the most common cancer located in the oral cavity. However, simultaneous treatment with cisplatin, bleomycin and 5-fluorouracil or treatment with paclitaxel and cisplatin are also used. These drugs can interact with the DNA, causing DNA crosslinks, double and single-strand breaks and changes in gene expression. Currently, the late effects of therapy have become a recurring problem, mainly due to the increased survival of HNC patients. Herein, we present an update of the systemic activity of RT and CT for HNC, with a focus on their toxicogenetic and toxicogenomic effects.
Resumo:
Pós-graduação em Biociências e Biotecnologia Aplicadas à Farmácia - FCFAR
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
Pós-graduação em Química - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordination compounds of trivalent lanthanides cations with diphenylphosphinate are originated from direct reaction between a lanthanide salt and diphenylphosphinic acid. These complexes have peculiar and intriguing features, as (i) quickly obtainment through wet process precipitation, (ii) appreciable thermal stability, similar to inorganic phosphates, (iii) polymeric structure, and consequently, (iv) low solubility in both polar and non-polar solvents. Nowadays, coordination polymers are classified as coordination networks or, in case of porous materials, as metal-organic frameworks (MOFs). By this study, we aim to determine some optical properties of rare-earth diphenylphosphinate (RE = La3+, Eu3+, Gd3+, Lu3+) and conduct an updated classification of these compounds, bringing more details of its structure and the possible proposal of new materials with applications in lighting, detection of ionizing radiation and magnetism. The complexes of trivalent rare-earth cation with diphenylphosphinate were prepared by direct mixture of diphenylphosphinic acid with rare-earth metal chloride, both in ethanolic solution. The solution of diphenylphosphinic acid was kept in a beaker under constant stirring with pH measurements of the solution and gadolinium chloride solution was then dripped slowly with the aid of a burette until its complete addition; the following metal:ligand molar ratios were tested: 1:1, 1:2, 1:3, 2:1 e 3:1. The compounds were characterized by spectroscopic and structural techniques. By Fourier Transform Infrared Spectroscopy (FT-IR), it was possible to check the total ionization of diphenylphosphinic acid in synthesized complexes, confirmed by the absence of the band type A, B, C related to ѵ(O-H) of the acid (2663 cm-1, 2168 cm-1, 1684 cm-1), as well as the disappearance of ѵ(P-OH)=961 cm-1. Furthermore, the occurrence of bands shifts of ѵ(POO-) [symmetrical and asymmetrical] of...