872 resultados para Hand-held devices
Resumo:
Heart failure is the final stage of most of cardiac diseases. It is a complex syndrome in which the patients should have the following features: symptoms of heart failure, typically shortness of breath at rest or during exertion, and/or fatigue; signs of fluid retention such as pulmonary congestion or ankle swelling; and objective evidence of an abnormality of the structure or function of the heart at rest. This progressive syndrome as a high incidence and prevalence and poor prognosis: four-year mortality is around 50% with 40% of the patients admitted to hospital dying or readmitted within a year. With ageing, many patients will develop chronic heart failure, which, because of its symptoms, patient’s awareness of their risk of dying, and the effects of therapy, together with frequent hospitalizations, has considerable impact on patient’s health-related quality of life.
Resumo:
Esta tese tem como principal objectivo a investigação teórica e experimental do desempenho de um sensor polarimétrico baseado num cristal líquido para medição da concentração de glicose. Recentemente uma série de sensores polarimétricos baseados em cristais líquidos foram propostos na literatura e receberam considerável interesse devido as suas características únicas. De facto, em comparação com outros moduladores electro-ópticos, o cristal líquido funciona com tensões mais baixas, tem baixo consumo de energia e maior ângulo de rotação. Além disso, este tipo de polarímetro pode ter pequenas dimensões que é uma característica interessante para dispositivos portáteis e compactos. Existem por outro lado algumas desvantagens, nomeadamente o facto do desempenho do polarímetro ser fortemente dependente do tipo de cristal líquido e da tensão a ele aplicada o que coloca desafios na escolha dos parâmetros óptimos de operação. Esta tese descreve o desenvolvimento do sensor polarimétrico, incluindo a integração dos componentes de óptica e electrónica, os algoritmos de processamento de sinal e um interface gráfico que facilita a programação de diversos parâmetros de operação e a calibração do sensor. Após a optimização dos parâmetros de operação verificou-se que o dispositivo mede a concentração da glicose em amostras com uma concentração de 8 mg/ml, com uma percentagem de erro inferior a 6% e um desvio padrão de 0,008o. Os resultados foram obtidos para uma amostra com percurso óptico de apenas 1 cm.
Resumo:
In this paper we present results on the optimization of multilayered a-SiC:H heterostructures for wavelength-division (de) multiplexing applications. The non selective WDM device is a double heterostructure in a glass/ITO/a-SiC:H (p-i-n) /a-SiC:H(-p) /a-Si:H(-i')/a-SiC:H (-n')/ITO configuration. The single or the multiple modulated wavelength channels are passed through the device, and absorbed accordingly to its wavelength, giving rise to a time dependent wavelength electrical field modulation across it. The effect of single or multiple input signals is converted to an electrical signal to regain the information (wavelength, intensity and frequency) of the incoming photogenerated carriers. Here, the (de) multiplexing of the channels is accomplished electronically, not optically. This approach offers advantages in terms of cost since several channels share the same optical components; and the electrical components are typically less expensive than the optical ones. An electrical model gives insight into the device operation.
Resumo:
In this review paper different designs based on stacked p-i'-n-p-i-n heterojunctions are presented and compared with the single p-i-n sensing structures. The imagers utilise self-field induced depletion layers for light detection and a modulated laser beam for sequential readout. The effect of the sensing element structure, cell configurations (single or tandem), and light source properties (intensity and wavelength) are correlated with the sensor output characteristics (light-to-dark sensivity, spatial resolution, linearity and S/N ratio). The readout frequency is optimized showing that scans speeds up to 104 lines per second can be achieved without degradation in the resolution. Multilayered p-i'-n-p-i-n heterostructures can also be used as wavelength-division multiplexing /demultiplexing devices in the visible range. Here the sensor element faces the modulated light from different input colour channels, each one with a specific wavelength and bit rate. By reading out the photocurrent at appropriated applied bias, the information is multiplexed or demultiplexed and can be transmitted or recovered again. Electrical models are present to support the sensing methodologies.
Resumo:
In this paper we present results on the optimization of device architectures for colour and imaging applications, using a device with a TCO/pinpi'n/TCO configuration. The effect of the applied voltage on the color selectivity is discussed. Results show that the spectral response curves demonstrate rather good separation between the red, green and blue basic colors. Combining the information obtained under positive and negative applied bias a colour image is acquired without colour filters or pixel architecture. A low level image processing algorithm is used for the colour image reconstruction.
Resumo:
ZnO:Al/p (SiC:H)/i (Si:H)/n (SiC:H) large area image and colour sensor are analysed. Carrier transport and collection efficiency are investigated from dark and illuminated current-voltage (I-V) dependence and spectral response measurements under different optical and electrical bias conditions. Results show that the carrier collection depends on the optical bias and on the applied voltage. By changing the electrical bias around the open circuit voltage it is possible to filter the absorption at a given wavelength and so to tune the spectral sensitivity of the device. Transport and optical modelling give insight into the internal physical process and explain the bias control of the spectral response and the image and colour sensing properties of the devices.
Resumo:
Introdução – Avaliar a força de preensão mostrou ser de primordial importância pela sua relação com a capacidade funcional dos indivíduos, permitindo determinar níveis de risco para incapacidade futura e, assim, estabelecer estratégias de prevenção. Grande parte dos estudos utiliza o dinamómetro hidráulico JAMAR que fornece o valor da força isométrica obtida durante a execução do movimento de preensão palmar. Contudo, existem outros dinamómetros disponíveis, como é o caso do dinamómetro portátil computorizado E‑Link (Biometrics) que fornece o valor da força máxima (peak force), para além de outras variáveis, como a taxa de fadiga. Não existem, contudo, estudos que nos permitam aceitar e comparar ou não os valores obtidos com os dois equipamentos e porventura utilizá‑los indistintamente. Objetivos – Avaliar a concordância entre as medições da força de preensão (força máxima ou peak force em Kg) obtida a partir de dois equipamentos diferentes (dinamómetros portáteis): um computorizado (E‑Link, Biometrics) e outro hidráulico (JAMAR). Metodologia – Foram avaliados 29 indivíduos (13H; 16M; 22±7 anos; 23,2±3,3 kg/m2) em 2 dias consecutivos, na mesma altura do dia. A posição de teste escolhida foi a recomendada pela Associação Americana de Terapeutas Ocupacionais e foi escolhido o melhor resultado de entre 3 tentativas para a mão dominante. Realizou‑se uma análise correlacional entre os valores obtidos na variável analisada em cada equipamento (coeficiente de Spearman) e uma análise de Bland & Altman para verificar a concordância entre as duas medições. Resultados – O coeficiente de correlação entre as duas medições foi elevado (rS= 0,956; p<0,001) e, pela análise de Bland & Altman, os valores obtidos encontram‑se todos dentro do intervalo da média±2SD. Conclusões – As duas medições mostraram ser concordantes, revelando que os dinamómetros testados podem ser comparáveis ou utilizados indistintamente em diferentes estudos e populações. ABSTRACT: Introduction – Assess grip strength has proved to be of vital importance because of its relationship with functional capacity of individuals, in order to determine levels of risk for future disability and thereby establish prevention strategies. Most studies use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement. However, there are other dynamometers available, such as portable computerized dynamometer E‑Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue. There are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. Purpose – To evaluate the agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E‑Link, Biometrics) and a hydraulic (JAMAR). Methodology – 29 subjects (13H, 16M, 22 ± 7 years, 23.2 ± 3.3 kg/m2) were assessed on two consecutive days at the same time of day. The test position chosen was recommended by the American Association of Occupational Therapists and was considered the best result from three attempts for the dominant hand. A correlation was studied between values obtained in the variable analyzed in each equipment (Spearman coefficient) and Bland‑Altman analysis to assess the agreement between the two measurements. Results – The correlation coefficient between the two measurements was high (rs = 0,956, p <0,001) and Bland & Altman analysis of the values obtained are all within the range of mean±2SD. Conclusions – The two measurements were shown to be concordant, revealing that the tested dynamometers can be comparable or used interchangeably in different studies and populations.
Resumo:
A mat of electrospun cellulose fibers are deposed on transparent conductive oxide covered glass, and two such plates enclose a nematic liquid crystal. Thus two new types of Cellulose based Polymer Dispersed Liquid Crystal devices, based on hydroxypropylcellulose and Cellulose Acetate and the nematic liquid crystal E7 have been obtained. The current-voltage characteristics indicates ionic type conduction. Heating-cooling cycles have been applied on the samples and the activation energies have been determined. Simultaneously with the thermo-stimulated currents, the optical transmission dependence on the d.c. electric field and temperature was registered. ON-OFF switching times have been determined for different control voltages. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
O trabalho descrito nesta dissertação de mestrado foca-se em geral na investigação de antenas impressas. São apresentados conceitos básicos, em conjunto com alguns exemplos desenvolvidos. No entanto, o principal foco prende-se com técnicas de miniaturização e reconfigurabilidade de antenas. A miniaturização de antenas é um tema de investigação de longa data, no entanto, novas técnicas e soluções são apresentadas regularmente. Nesta tese, é aplicada uma técnica recente, baseada na introdução de indutores encapsulados no elemento ressonante de uma antena, que permite miniaturizar um monopólio impresso com uma frequência de ressonância de 2.5 GHz. Outro assunto abordado neste trabalho é a reconfigurabilidade de antenas. Algumas das técnicas mais comuns na investigação actual são apresentadas e debatidas. Uma solução com recurso a díodos PIN é usada para estudar esta capacidade. Os conceitos e características deste tipo de componentes são apresentadas sendo feito o desenho e fabrico de um possível monopólio impresso reconfigurável para operação em dupla banda. Por fim, são combinadas as técnicas de miniaturização com inductor encapsulado e reconfigurabilidade através de díodos PIN, por forma a projectar uma antena reconfigurável muito pequena, para operação em duas bandas distintas. Os resultados são discutidos e com base nestes, algumas possíveis otimizações são propostas. The work reported in this dissertation is focused in the printed antenna research. Basic concepts of printed antennas are presented, along with a few examples that were developed. The main focus however, is around miniaturization and reconfigurability of antennas. Antenna miniaturization is a long time research subject, however, new techniques and solutions are presented everyday. In this thesis, a recent technique based on the introduction of chip inductors in the resonating element of a printed antenna is used in order to miniaturize a monopole with a resonating frequency at 2.5 GHz. Another issue approached in this work is antenna reconfigurability. Some common techniques used in antenna reconfiguration are presented and debated. A solution with PIN diodes is used to study this capability. The concepts and characteristics of this type of components are presented and an example of a reconfigurable printed monopole for dual-band operation is designed and fabricated. At last, miniaturization with chip inductor and reconfigurability through PIN diodes are used together to create a very small antenna for dual-band operation. The simulated and measured results are discussed and upon these, some possible optimizations are proposed.
Resumo:
The characteristics of tunable wavelength filters based on a-SiC:H multilayered stacked pin cells are studied both theoretically and experimentally. The optical transducers were produced by PECVD and tested for a proper fine tuning of the cyan and yellow fluorescent proteins emission. The active device consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructures sandwiched between two transparent contacts. Experimental data on spectral response analysis, current-voltage characteristics and color and transmission rate discrimination are reported. Cyan and yellow fluorescent input channels were transmitted together, each one with a specific transmission rate and different intensities. The multiplexed optical signal was analyzed by reading out, under positive and negative applied voltages, the generated photocurrents. Results show that the optimized optical transducer has the capability of combining the transient fluorescent signals onto a single output signal without losing any specificity (color and intensity). It acts as a voltage controlled optical filter: when the applied voltages are chosen appropriately the transducer can select separately the cyan and yellow channel emissions (wavelength and frequency) and also to quantify their relative intensities. A theoretical analysis supported by a numerical simulation is presented.
Resumo:
In this paper, we present PSiS (Personalized Sightseeing Tours Recommendation System) Mobile. PSiS Mobile is our proposal to a mobile recommendation and planning support system, which is designed to provide effective support during the tourist visit with context-aware information and recommendations about places of interest (POI), exploiting tourist preferences and context.
Resumo:
Although we have many electric devices at home, there are just few systems to evaluate, monitor and control them. Sometimes users go out and leave their electric devices turned on what can cause energy wasting and dangerous situations. Therefore most of the users may want to know the using states of their electrical appliances through their mobile devices in a pervasive way. In this paper, we propose an Intelligent Supervisory Control System to evaluate, monitor and control the use of electric devices in home, from outside. Because of the transferring data to evaluate, monitor and control user's location and state of home (ex. nobody at home) may be opened to attacks leading to dangerous situations. In our model we include a location privacy module and encryption module to provide security to user location and data. Intelligent Supervising Control System gives to the user the ability to manage electricity loads by means of a multi-agent system involving evaluation, monitoring, control and energy resource agents.
Resumo:
Dissertação apresentada à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ciências da Educação - Especialidade Supervisão em Educação
Resumo:
Levels of risk for future disability can be assessed with grip strength. This assessment is of fundamental importance for establishing prevention strategies. It also allows verifying relationships with functional capacity of individuals. Most studies on grip strength use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement and is considered the “gold standard” for measurement of grip strength. However, there are different dynamometers available commercially, such as portable computerized dynamometer E-Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue for hand strength, among others. Of our knowledge, there are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. The aim of this study was to evaluate the absolute agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E-Link, Biometrics) and one hydraulic (JAMAR).
Resumo:
In this paper we present a mobile recommendation and planning system, named PSiS Mobile. It is designed to provide effective support during a tourist visit through context-aware information and recommendations about points of interest, exploiting tourist preferences and context. Designing a tool like this brings several challenges that must be addressed. We discuss how these challenges have been overcame, present the overall system architecture, since this mobile application extends the PSiS project website, and the mobile application architecture.