Endocrine treatment for breast cancer was introduced more than a century ago. The discovery of hormone receptors has allowed targeting of endocrine treatment to patients whose primary tumours express these receptors. In the adjuvant setting, different approaches are used in premenopausal or postmenopausal women. In premenopausal patients, suppression of ovarian function and the use of tamoxifen are the most important therapeutic options, even though questions on timing, duration, and combination of these compounds remain unanswered. The use of aromatase inhibitors in combination with ovarian-function suppression is currently under investigation in the premenopausal setting. In postmenopausal patients, aromatase inhibitors given after 2-3 years or 5 years of tamoxifen have shown a significant benefit over tamoxifen alone. However, questions on this treatment also remain unanswered. For example, whether all patients should receive an aromatase inhibitor or whether some subgroups of patients might be optimally treated by tamoxifen alone is yet to be established. In this paper we review the published work on adjuvant endocrine treatment in breast cancer and provide recommendations from the 2007 St Gallen International Conference on Primary Therapy of Early Breast Cancer.
Resumo:
This study aimed to identify the microbial contamination of water from dental chair units (DCUs) using the prevalence of Pseudomonas aeruginosa, Legionella species and heterotrophic bacteria as a marker of pollution in water in the area of St. Gallen, Switzerland. Water (250 ml) from 76 DCUs was collected twice (early on a morning before using all the instruments and after using the DCUs for at least two hours) either from the high-speed handpiece tube, the 3 in 1 syringe or the micromotor for water quality testing. An increased bacterial count (>300 CFU/ml) was found in 46 (61%) samples taken before use of the DCU, but only in 29 (38%) samples taken two hours after use. Pseudomonas aeruginosa was found in both water samples in 6/76 (8%) of the DCUs. Legionella were found in both samples in 15 (20%) of the DCUs tested. Legionella anisa was identified in seven samples and Legionella pneumophila was found in eight. DCUs which were less than five years old were contaminated less often than older units (25% und 77%, p<0.001). This difference remained significant (0=0.0004) when adjusted for manufacturer and sampling location in a multivariable logistic regression. A large proportion of the DCUs tested did not comply with the Swiss drinking water standards nor with the recommendations of the American Centers for Disease Control and Prevention (CDC).