455 resultados para GLAUCOMA


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Measures that reflect patients' assessment of their health are of increasing importance as outcome measures in randomised controlled trials. The methodological approach used in the pre-validation development of new instruments (item generation, item reduction and question formatting) should be robust and transparent. The totality of the content of existing PRO instruments for a specific condition provides a valuable resource (pool of items) that can be utilised to develop new instruments. Such 'top down' approaches are common, but the explicit pre-validation methods are often poorly reported. This paper presents a systematic and generalisable 5-step pre-validation PRO instrument methodology.

METHODS: The method is illustrated using the example of the Aberdeen Glaucoma Questionnaire (AGQ). The five steps are: 1) Generation of a pool of items; 2) Item de-duplication (three phases); 3) Item reduction (two phases); 4) Assessment of the remaining items' content coverage against a pre-existing theoretical framework appropriate to the objectives of the instrument and the target population (e.g. ICF); and 5) qualitative exploration of the target populations' views of the new instrument and the items it contains.

RESULTS: The AGQ 'item pool' contained 725 items. Three de-duplication phases resulted in reduction of 91, 225 and 48 items respectively. The item reduction phases discarded 70 items and 208 items respectively. The draft AGQ contained 83 items with good content coverage. The qualitative exploration ('think aloud' study) resulted in removal of a further 15 items and refinement to the wording of others. The resultant draft AGQ contained 68 items.

CONCLUSIONS: This study presents a novel methodology for developing a PRO instrument, based on three sources: literature reporting what is important to patient; theoretically coherent framework; and patients' experience of completing the instrument. By systematically accounting for all items dropped after the item generation phase, our method ensures that the AGQ is developed in a transparent, replicable manner and is fit for validation. We recommend this method to enhance the likelihood that new PRO instruments will be appropriate to the research context in which they are used, acceptable to research participants and likely to generate valid data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lowering intraocular pressure in adults with glaucoma may be associated with an improvement in appearance of the optic nerve head. The stage of disease, the amount of intraocular pressure reduction, and the age of the patient probably influence the occurrence of this event. The clinical relevance of 'reversal' has not been established with certainty. The reversibility of glaucomatous cupping can be detected by subjective and qualitative means (examination of the patient or of fundus photographs) or by quantitative techniques such as photogrammetry, computerized image analysis, and scanning laser tomography. Clinical and experimental studies are providing new information about the behavior of the optic nerve head tissues in response to changes in intraocular pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.

OBJECTIVES: To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG.

SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012.

SELECTION CRITERIA: We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations, using laser peripheral iridoplasty to break acute crisis.

DATA COLLECTION AND ANALYSIS: No analysis was carried out as only one trial was included in the review.

MAIN RESULTS: We included one RCT with 158 participants. The trial reported laser peripheral iridoplasty as an adjunct to laser peripheral iridotomy compared to iridotomy alone. The authors report no superiority in using iridoplasty as an adjunct to iridotomy for IOP, number of medications or need for surgery.

AUTHORS' CONCLUSIONS: There is currently no strong evidence for laser peripheral iridoplasty's use in treating angle-closure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations. OBJECTIVES: To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles, PAC and PACG. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library), MEDLINE, EMBASE and LILACS (Latin American and Caribbean Literature on Health Sciences). The databases were last searched on 11 February 2008. SELECTION CRITERIA: Only randomised controlled trials (RCTs) were eligible for inclusion in this review. Patients with narrow angles, PAC or PACG were eligible. Studies that included only patients with acute presentations, using laser peripheral iridoplasty to break acute crisis were excluded. DATA COLLECTION AND ANALYSIS: No analysis was carried out due to lack of trials. MAIN RESULTS: There were no RCTs assessing laser peripheral iridoplasty in the non-acute setting of angle-closure. AUTHORS' CONCLUSIONS: There is currently no strong evidence for laser peripheral iridoplasty's use in treating angle-closure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A paracentesis is performed in glaucoma procedures as a flat, beveled tract to allow access into the anterior chamber after the filtration fistula is made. Complications related to the paracentesis are infrequent because it is a self-sealing wound. The authors report a case of infectious keratitis that developed in a paracentesis tract.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The authors sought to quantify neighboring and distant interpoint correlations of threshold values within the visual field in patients with glaucoma. Methods: Visual fields of patients with confirmed or suspected glaucoma were analyzed (n = 255). One eye per patient was included. Patients were examined using the 32 program of the Octopus 1-2-3. Linear regression analysis among each of the locations and the rest of the points of the visual field was performed, and the correlation coefficient was calculated. The degree of correlation was categorized as high (r > 0.66), moderate (0.66 = r > 0.33), or low (r = 0.33). The standard error of threshold estimation was calculated. Results: Most locations of the visual field had high and moderate correlations with neighboring points and with distant locations corresponding to the same nerve fiber bundle. Locations of the visual field had low correlations with those of the opposite hemifield, with the exception of locations temporal to the blind spot. The standard error of threshold estimation increased from 0.6 to 0.9 dB with an r reduction of 0.1. Conclusion: Locations of the visual field have highest interpoint correlation with neighboring points and with distant points in areas corresponding to the distribution of the retinal nerve fiber layer. The quantification of interpoint correlations may be useful in the design and interpretation of visual field tests in patients with glaucoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has been shown that mitomycin-C increases the success rate of trabeculectomy; however, a rise in the incidence of postoperative complications has also been reported. Consequently, the use of antimetabolite is usually reserved for patients who are at high risk of surgical failure or for patients with advanced glaucoma in whom low intraocular pressure is desired. This report describes a patient who suffered severe visual loss which was a direct result of hypotonous maculopathy after trabeculectomy with mitomycin-C and various other complications from the subsequent interventions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the outcome of combined mitomycin-C filtering surgery, phacoemulsification, and foldable intraocular lens (IOL) implantation. Setting: Wills Eye Hospital, Thomas Jefferson University, Philadelphia, Pennsylvania, USA. Methods: This retrospective study evaluated 182 eyes of 174 patients who had combined mitomycin-C trabeculectomy, phacoemulsification, and insertion of a foldable IOL through a 3.5 mm incision. Success of the combined procedure was defined as intraocular pressure (IOP) below 21 mm Hg, with or without medications, and no serious complication. Success rates were calculated using the Kaplan-Meier actuarial method. Results: Mean follow-up was 16.7 months ± 5.4 (SD). The probability of success at 6, 12, 18, and 24 months was 98.3, 95.6, 90.6, and 88.0%, respectively. When compared with preoperativety, visual acuity improved one or more lines in 148 eyes (81.3%) and worsened one or more lines in 15 (8.2%); 111 eyes (61.0%) achieved visual acuity of 20/40 or better. The most frequent complication was posterior capsule opacification requiring capsulotomy, which occurred in 22 cases (12.0%). Conclusion: The 1 year and 2 year IOP control rate of combined mitomycin-C filtering procedures and phacoemulsification in glaucoma patients was high.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose . To investigate alternative surgical method to cover subconjunctival portion of the tube in tube shunt surgery in glaucoma Methods. In thirteen eyes of twelve patients who underwent tube shunt surgery at WEH between July 1991 to November 1996 a "rotating" autologous scleral lamellar graft was created to cover the subconjuctival course of the tube. These patients were followed for clinical signs of conjuctival breakdown, graft melt, tube erosion, anterior staphylomas, graft related inflammation, infections or graft related complications. Results. The patients were followed up for a mean of 16 5 months( range 1-60 months). All eyes tolerated the autologous graft well without any clinical evidence of tube erosions, graft melting , graft related or intraocular inflammation Conclusions The use of autologous sciera, to cover the tube in a tube shunt procedure appears to be effective and without inappropriate short term risk. It offers the advantages of availability , lower cost, and eliminates the potential risk of transmission of infectious disease( i.e. slow-virus, HIV etc.).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to assess the effect on intraocular pressure (IOP) and the safety and tolerability of oromucosal administration of a low dose of delta-9-tetrahydrocannabinol (?-9-THC) and cannabidiol (CBD). PATIENTS AND METHODS: A randomized, double-masked, placebo-controlled, 4 way crossover study was conducted at a single center, using cannabis-based medicinal extract of ?-9-THC and CBD. Six patients with ocular hypertension or early primary open angle glaucoma received a single sublingual dose at 8 AM of 5 mg ?-9-THC, 20 mg CBD, 40 mg CBD, or placebo. Main outcome measure was IOP. Secondary outcomes included visual acuity, vital signs, and psychotropic effects. RESULTS: Two hours after sublingual administration of 5 mg ?-9-THC, the IOP was significantly lower than after placebo (23.5 mm Hg vs. 27.3 mm Hg, P=0.026). The IOP returned to baseline level after the 4-hour IOP measurement. CBD administration did not reduce the IOP at any time. However, the higher dose of CBD (40 mg) produced a transient elevation of IOP at 4 hours after administration, from 23.2 to 25.9 mm Hg (P=0.028). Vital signs and visual acuity were not significantly changed. One patient experienced a transient and mild paniclike reaction after ?-9-THC administration. CONCLUSIONS: A single 5 mg sublingual dose of ?-9-THC reduced the IOP temporarily and was well tolerated by most patients. Sublingual administration of 20 mg CBD did not reduce IOP, whereas 40 mg CBD produced a transient increase IOP rise. Copyright © 2006 by Lippincott Williams & Wilkins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study was designed to evaluate the clinical agreement in the detection of optic disc changes and the ability of computerized image analysis to detect glaucomatous deterioration of the optic disc. Methods: Pairs of stereophotographs of 35 glaucomatous optic discs taken 5 years apart and of 5 glaucomatous discs photographed twice on the same day. Two glaucoma specialists examined the pairs of stereophotographs (35 cases and 5 controls) in a masked manner and judged whether the optic disc showed changes in the optic disc compatible with progression of glaucomatous damage. The stereophotographs of the five optic discs photographed twice on the same day (which by definition did not change) and of five cases judged to have deteriorated by both glaucoma specialists were analyzed by computerized image analysis with the Topcon ImageNet system. Intra- and inter-observer agreement in the detection of optic disc changes (evaluated using kappa statistic), and changes in the rim area to disc area ratio (evaluated using descriptive statistics and paired t-test). Results: Intra-observer agreement had a kappa value of 0.75 for observer 1 and 0.60 for the observer 2. Inter-observer agreement between the glaucoma specialists had a kappa value of 0.60. The image analyzer did not discriminate between controls and cases with clinically apparent glaucomatous change of the optic disc. Conclusion: Clinical agreement in detecting changes in the optic disc was moderate to substantial. Computerized image analysis with the Topcon ImageNet system appeared not to be useful in detecting glaucomatous changes of the optic disc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare the diagnostic abilities of the standard bracketing strategy (BR) and a fast strategy, the tendency-oriented perimetry (TOP). Methods: Seventy-seven controls and 91 eyes from patients with glaucoma were analyzed with the strategies TOP and BR. Sensitivity (Se), specificity (Sp), the area under the receiver operating characteristic (ROC) curve (AC) and the optimum cutoff value (CO) were calculated for the visual field indices mean defect (MD), the square root of the loss variance (sLV) and the number of pathological points (NPP). Results: In the glaucoma group, the mean MD value using TOP and BR was 7.5 and 8.3 dB, respectively. The mean sLV value using TOP and BR was 5.0 and 5.3 dB, respectively. Indices provided by TOP had higher ROC values than the ones provided by BR. Using TOP, the index with the best diagnostic ability was sLV (Sp = 94.8, Se = 90.1, AC = 0.966, CO = 2.5 dB), followed by NPP and MD. Using BR, the best results were obtained for MD (Sp = 92.2, Se = 81.3, AC = 0.900, CO = 2.5 dB) followed by sLV and NPP. Conclusions: A fast strategy, TOP, had superior diagnostic ability than the standard BR. Although TOP provided lower LV values than BR, the diagnostic ability of this index was higher than that of the conventional strategy. Copyright © 2005 S. Karger AG.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To study the long-term outcome of deep sclerectomy in patients with open angle glaucoma. Methods: Prospective consecutive series of 43 eyes (38 patients) with medically uncontrolled open-angle glaucoma undergoing deep sclerectomy. All patients underwent clinical assessment before and after surgery at day 7 and at months 1, 3, 6, 12, 18, 24, 36. Surgical success was considered if the patient's intraocular pressure (IOP)>22 mmHg and the IOP was lowered by more than 20% without the use of any medication. Kaplan-Meier survival curves were used to evaluate the success rate. Results: The mean follow-up time was 28.1±8.2 months. Mean IOP decreased significantly from a preoperative value of 24.6±5.5 mmHg to a postoperative value of 18.5±4.6 mmHg at 36 months (P>0.001). Microperforation of TDM occurred in three cases (7.0%) and ciliary body prolapse in one case (2.3%) but did not prevent completion of the operation. Postoperatively, hyphaema was detected in one case and shallow anterior chamber in another case and both were treated conservatively. Bleb encapsulation with elevation of IOP occurred in two cases (4.7%) and was treated with 5-fluorouracil subconjunctival injection. Goniopuncture with neodymium : YAG laser was performed in two cases (4.7%). There were no other late complications with the exception of failure of the operation. On the life-table analysis the success rate at 12, 24, and 30 months were 61.4, 36.6, and 18.9%, respectively. Conclusion: Deep sclerectomy reduced the IOP temporarily while minimising the risk of postoperative complications commonly encountered with standard trabeculectomy. However, after long-term follow-up surgery failed to maintain a low IOP. © 2006 Nature Publishing Group. All rights reserved.