875 resultados para Equilíbrio músculo-esquelético


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patellofemoral pain syndrome (PFPS) is described as anterior or retropatellar pain knee in the absence of other pathologies and is frequently associated with dysfunction of the vastus medialis oblique (VMO). However, several studies have demonstrated the inability to selectively activate this muscle through exercise. To evaluate the effect of Neuromuscular Electrical Stimulation (NMES) selective VMO in women with syndrome. We evaluated thirty-eight women: twenty in the control group (24.15 ± 2.60 years) and eighteen diagnosed with PFPS (25.56 ± 3.55 years). Both groups were evaluated before and after a protocol of electro stimulation. To measure for comparing groups before and after treatment, we assessed the extensor torque concentric and eccentric knee through an isokinetic dynamometer, the intensity (Root Mean Square - RMS) and the onset of activation (onset) of VMO compared to the vastus lateralis (VL) in two types of exercise: open and closed kinetic chain. . Statistical analysis was performed using SPSS 15.0, with a significance level of 5%. Results: Our data showed an increase in the intensity of activation (RMS) of the VMO muscle after NMES in both study groups. During concentric contraction the RMS of the VMO before the NMES was 105.69 ± 32.26 μV and after a single intervention was 122.10 ± 39.62 μV (p = 0.048) for the control group. In the group with PPS, we found a similar behavior, with RMS of the VMO before NMES of 96.25 ± 18.83 μV and 139.80 ± 65.88 μV after the intervention (p = 0.0001). However, there was no evidence in the RMS value of VL muscle. The onset was calculated by subtracting the onset of VL by the onset of VMO. For the group with PFPS, the onset before the intervention was -0.007 ± 0.14 ms, indicating a delay of the VMO relative to VL, and after NMES was 0.074 ± 0.09 ms (p = 0.016), showing an activation previous VMO to VL. The same occurred for the control group. We also observed that NMES increased knee extensor power during the concentric contraction in both groups. Before the intervention the mean power was 28.97 ± 9.01 W for the PPS group and after NMES was 34.38 ± 7.61 W (p = 0.0001). Conclusion: We observed an increase in electromyographic activity of the VMO and also an anticipatory effect of this muscle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the effects of warm-up and stretching, singly or combined, on isokinetic performance and electromyographic activity of the biceps femoris. Materials and methods: Sixty-four volunteers of both sexes, with mean age of 23,1 ± 3,5 years and mean body mass index of 23,5 ± 2,5 Kg/m2 were randomly assigned into 4 groups: control, warm-up (stationary bicycle for 10 minutes), stretching (4 sets of 30 seconds of hamstring muscles static stretching) and warm-up + stretching. All the volunteers were submitted to evaluation pre and post-intervention of the muscle latency time and biceps femoris RMS and the passive torque, peak torque and power of the hamstring muscles. Results: The warm-up + stretching group had reduction of muscle latency time. There was a reduction of RMS during passive torque evaluation in stretching group. The RMS during isometric evaluation was reduced in all experimental groups. The RMS during eccentric evaluation showed reduction in control and warm-up + stretching groups. The passive torque and the eccentric peak torque had no significant differences pre to post-intervention in any group. There was reduction in isometric peak torque in all groups. Conclusion: The warm-up and stretching, when applied in combination can reduce the muscle latency time; stretching protocol promoted neural changes; the protocols used did not alter the muscle viscoelastic properties

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze the effects of electrical stimulation at two frequencies on the EMG parameters (EMG) and dynamometer, in muscles with different typing. MATERIALS AND METHODS: This is a controlled clinical trial, randomized and double blind. Sixty healthy volunteers (23.6 ± 4.2anos; 54.2 ± 7.7kg, 1.62 ± 0.009 cm) of both sexes were divided randomly into three groups: control group (CG), experimental group 1 (SG1) with application of the current Russian 30 HZ and experimental group 2 (EG2) at 70 Hz The volunteers performed an initial assessment (AV1) on the isokinetic dynamometer with three repetitions maximum voluntary isometric (MVC) for knee extension concomitant uptake of EMG for the VM muscle, VL and RF. Later, after application of NMES, they underwent an experimental protocol of isometric fatigue using 70% of MVIC, ending with the completion of a final assessment (AV2) in the same manner as the AV1. RESULTS: By analyzing the profile of the 60 subjects in three broad, VM showed a higher value of RMS behavior when the VL and RF (p = 0.03 and p = 0.02). With respect to Fmed the RF muscle (p = 0.001) showed a higher value for the VM. The VM muscle showed significant increases of Fmed (p = 0.05) after electrical stimulation at 70 Hz when compared the AV1 AV2 and RF showed significant decreases (p = 0.009) after stimulation at 30 Hz during the fatigue showed an increase RMS in the VM and VL, with a reduction in RF. For the variable Fmed was observed in three broad decline during fatigue. CONCLUSION: Our findings provide evidence that the muscles VM, VL and RF fiber typing are different besides indicating that the frequency of NMES tend to relate to the muscle stimulated. Finally suggests the surface EMG as a noninvasive method for characterizing muscle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective:To analyze the immediate effects of the Kinesio Taping® application on the quadriceps neuromuscular performance, postural balance and lower limb function in healthy subjects. Materials andmethods:This is a randomized, controlled, blinded clinical trial. Sixtyfemale volunteers(age: 23.3±2.5 years old, BMI: 22.2±2.1kg/m2)wererandomly assigned intothreegroups with20memberseach,and performedone of these threeprotocols: control -10 minutesof rest,experimental 1- patch application ontherectusfemoris (RF), vastuslateralis(VL) and vastusmedialis(VM) and experimental 2-KT application on the same muscles. Allunderwent an evaluationfor singleand triple hop distance, postural balance (baropodometry), joint position sense(JPS), peak torque (concentric and eccentricevaluation at 60°/s)and electromyographic activityof VL,before andafter intervention.Results: There wasasignificant increasein the jump distanceof thethreestudied groups,with no differencebetween groups.There were nosignificant changesin postural balance,JPS, concentricpeak torqueand RMSof the VLin none of the groups. There was a reduction ineccentricpeak torquein all groups, without differencesbetween groups.Conclusion:The KT application on the RF, VL and VMmusclesis not able tosignificantly improvelower limbfunction and postural balance, as well as the kneeextensor peaktorque, JPSand the VL muscleactivation amplitudeof healthy women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Pilates Method is a modality of exercise that has been growing in recent decades, but few researches has been conducted with elderly and little is known about its benefits in this population. Objective: To evaluate the effect of a program of Mat Pilates exercises in muscle performance and postural balance in elderly women. Materials and Method: This is a randomized controlled trial that evaluated the muscle performance (isokinetic dynamometer Biodex System 3 Pro®) and postural balance (Balance Master System®) of 33 women aged 65-80 years. The experimental group (EG) participated of a 12-week program of Mat Pilates exercises with two weekly sessions. Data normality was verified by the Shapiro - Wilk test and were adopted p value < 0.05 as significance level. Results: There were no differences between groups after training. However, the EG showed an increase in the values of extension and flexion average power to 60 ° / s after training (32.19 W to 37.04 W and 14.48 W to 17.56 W, respectively). Conclusion: The proposed exercise program was not effective in the total work and average power of flexor and extensor of the knee, as well as static and dynamic balance of participants

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aging process modifies various systems in the body, leading to changes in mobility, balance and muscle strength. This can cause a drop in the elderly, or not changing the perceived self-efficacy in preventing falls. Objective: To compare the mobility, body balance and muscle performance according to self-efficacy for falls in community-dwelling elderly. Methods: A cross-sectional comparative study with 63 older (65-80 years) community. Were evaluated for identification data and sociodemographic, cognitive screening using the Mini Mental State Examination (MMSE), effective for the fall of Falls Efficacy Scale International Brazil (FES-I-BRAZIL), Mobility through the Timed Up and Go Test , the balance Berg Balance Scale (BBS) and the Modified Clinical Test tests of Sensory Interaction on Balance (mCTSIB), tandem walk (TW) and Sit to Stand (STS) of the Balance Master® System. Finally, muscle performance by using isokinetic dynamometry. Statistical analysis was performed Student t test for comparison between groups, with p value ≤ 0.05. Results: Comparing the elderly with low-efficacy for falls with high-efficacy for falls, we found significant differences only for the variable Timed Up and Go Test (p = 0.04). With regard to data on balance tests were significant differences in the speed of oscillation firm surface eyes open modified Clinical Test of Sensory Interaction on Test of Balance (p = 0.01). Variables to isokinetic dynamometry were no significant differences in movement knee extension, as regards the variables peak torque (p = 0.04) and power (p = 0.03). Conclusion: The results suggest that, compared to older community with low-and high-efficacy for falls, we observed differences in variables related to mobility, balance and muscle function

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Wii Balance Board (WBB) began to be investigated as a low-cost alternative for assessing static balance in vertical posture. However, studies employed methodological procedures that did not eliminate result variability between the tests and equipment used. Objective: Determine the validity and reproducibility of the WBB as an instrument for assessing static balance in the vertical position, using simultaneous data analysis and superimposed equipment. Methods: This is an accuracy study of 29 healthy young individuals of both sexes aged 18 to 30 years. Subjects were assessed 24h apart (test-retest), using unipodal and bipodal support tests, with eyes closed and open. To that end the WBB was placed on top of a force platform (FP) and data (postural sway) were collected simultaneously on both devices. Validity and reproducibility were analyzed using the interclass correlation coefficient (ICC). Finally, Bland-Altman analysis was applied to assess agreement. Results: The sample was composed of 23 women and 6 men, with mean age of 24.2±6.3 years, 60.7±6.3 kg and 1.64±4.2 m. The validity of the WBB compared to the FP was excellent for all 4 tasks proposed (ICC = 0.93 0.98). The reproducibility analyzed by test-retest was excellent for the bipodal support tasks (ICC = 0.93-0.98) and only moderate for the unipodal support tests (ICC = 0.46 0.70). Graphic analysis exhibited good agreement between the devices, since most of the measures were within the limits of agreement. Conclusion: this study proved the validity and reproducibility of the Wii Balance Board as an instrument for assessing static balance in vertical posture, using simultaneous analysis with superimposed equipment. Thus, the WBB has been increasingly used by physical therapists and other health professionals in their clinical practice, as both a rehabilitation and assessment tool

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The phenomenon of adsorption is of fundamental importance for the treatment of textile effluents and removal of dyes. Chitosan is characterized as an excellent adsorbent material, not only for its adsorption capacity but also the low cost production. Equilibrium and kinetic studies were developed in this study to describe the mechanism of adsorption of the anionic azo dye Orange G in chitosan, with the isotherms obtained from the variation of the concentration of dye in the continuous phase. The kinetics of the process was analyzed based on models involving the adsorption of molecules of the dye in nonpolar and polar sites. Adsorption experiments were carried out in water and in saline media with different NaCl concentrations, both for the determination of the equilibrium time as isotherms for making kinetic curves in which the amount of dye adsorbed measured indirectly varied with time. The experiments revealed the opening of the biopolymer structure with increasing concentration of Orange G, accompanied by high pH values and change on the type of interaction between the dye and the adsorbent surface, suggesting behavior advocated by the Langmuir equation in a certain range of concentration of the adsorbate and following the Henry's Law at higher concentrations, from the increased number of sites available for adsorption. The studies conducted showed that the saline medium reduces the chitosan s adsorption capacity according to a certain concentration, the occurrence of the cooperative adsorption process steps kinetic mechanism suggested as a new alternative for the interpretation of the phenomenon

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of analogies in high school is often useful for chemistry teaching, either on textbooks or by teachers in the classroom.This use is justified by the large number of abstract concepts that rules this course. Analogies are conceptualized by several authors, which converge on the idea that these are tools that seek a way to elucidate an unknown concept by comparing it to a familiar one, relating their similar and dissimilar features. An analysis on a survey of analogies found in high school chemistry textbooks and chemical equilibrium studies is performed in order to verify whether they are leading to misconceptions for their use by students and/or for their use by teachers in the classroom, or whether they promote a learning facilitation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO: Diagnosticar os parâmetros clínicos associados com as quedas em idosos tornou-se um grande desafio para a comunidade científica. Apesar da existência de diversos instrumentos direcionados à avaliação do equilíbrio corporal em idosos, ainda é escasso o número de trabalhos que investigaram e discutiram a concordância entre os diversos métodos. OBJETIVO: Analisar a correlação entre alguns testes usados para avaliar o equilíbrio corporal no idoso. MÉTODOS: Tratou-se de um estudo transversal, observacional, realizado com 30 voluntárias idosas comunitárias, hígidas, com diferentes níveis de condicionamento físico. Foram utilizados o Teste de Alcance Funcional Anterior (TAF), a Escala de Equilíbrio de Berg (EEB), o teste Timed Up and Go (TUG) e o Teste de Equilíbrio de Tinetti (Performance Oriented Mobility Assessment - POMA). A correlação dos dados foi realizada por meio da aplicação do Coeficiente de Correlação de Spearman, com nível de significância de 5% (p<0,05). RESULTADOS: Observou-se correlação positiva e moderada entre o TAF e a EEB (r=0,4845; p=0,0067), entre o TAF e a POMA (r=0,4136; p= 0,0231), entre a EEB e a POMA (r=0,6088; p=0,0004). CONCLUSÃO: Os testes são complementares, dado que se mostraram com particularidades e limitações distintas. Torna-se razoável, portanto, a aplicação conjunta desses instrumentos para melhor avaliar o equilíbrio de idosas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVOS: Avaliar o equilíbrio postural e o risco de quedas em idosos institucionalizados e não-institucionalizados. MÉTODOS: Foram incluídos no estudo 45 idosos institucionalizados e 43 idosos não-institucionalizados. O equilíbrio e o risco de quedas foram avaliados através da Escala de Equilíbrio de Berg. A comparação do equilíbrio entre os grupos foi feita por meio do teste de Mann-Whitney. Foi avaliado o risco para queda entre as populações. Adotou-se um valor de p ≤ 0,05 como significante. RESULTADOS: Houve diferença entre os escores da Escala de Berg nas populações estudadas (p < 0,0001). Os resultados mostraram que a população institucionalizada apresenta nove vezes mais risco de cair do que idosos da comunidade (p=0,0001). CONCLUSÕES: Os resultados indicam que o equilíbrio postural é menor na população institucionalizada, aumentando seu risco de cair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complex systems have stimulated much interest in the scientific community in the last twenty years. Examples this area are the Domany-Kinzel cellular automaton and Contact Process that are studied in the first chapter this tesis. We determine the critical behavior of these systems using the spontaneous-search method and short-time dynamics (STD). Ours results confirm that the DKCA e CP belong to universality class of Directed Percolation. In the second chapter, we study the particle difusion in two models of stochastic sandpiles. We characterize the difusion through diffusion constant D, definite through in the relation h(x)2i = 2Dt. The results of our simulations, using finite size scalling and STD, show that the diffusion constant can be used to study critical properties. Both models belong to universality class of Conserved Directed Percolation. We also study that the mean-square particle displacement in time, and characterize its dependence on the initial configuration and particle density. In the third chapter, we introduce a computacional model, called Geographic Percolation, to study watersheds, fractals with aplications in various areas of science. In this model, sites of a network are assigned values between 0 and 1 following a given probability distribution, we order this values, keeping always its localization, and search pk site that percolate network. Once we find this site, we remove it from the network, and search for the next that has the network to percole newly. We repeat these steps until the complete occupation of the network. We study the model in 2 and 3 dimension, and compare the bidimensional case with networks form at start real data (Alps e Himalayas)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Quantificar a gordura presente no músculo levantador da pálpebra de portadores de ptose congênita, correlacionando este achado com fatores clínico-epidemiológicos desta afecção. MÉTODOS: Vinte e duas amostras de músculo levantador da pálpebra superior, provenientes de portadores de ptose congênita, foram avaliadas morfometricamente, com o intuito de quantificar a gordura presente nos espécimes e correlacionar este achado com características como idade, sexo, grau de ptose e função do músculo levantador. RESULTADOS: Não houve correlação entre a quantidade de gordura encontrada no músculo levantador de portadores de ptose congênita e os dados clínicos dos pacientes estudados. CONCLUSÃO: A quantidade de gordura presente no músculo levantador da pálpebra superior, nas condições do presente estudo, não está associada com idade, sexo, grau de ptose ou função do músculo levantador. Novos estudos serão necessários para avaliar a real alteração que ocorre no músculo levantador da pálpebra de indivíduos com ptose palpebral.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do estudo foi avaliar a eficácia do fixador esquelético pino-resina, configuração tipo II, coadjuvado pelo enxerto ósseo esponjoso autólogo, no tratamento das complicações secundárias à imobilização inadequada de fraturas do rádio e ulna em 10 cães, com peso entre 1,8 e 33,6 kg. Detectou-se não-união (n=4), osteomielite (n=1), má-união (n=1), falência ou quebra de implante (n=4), sendo 60% das lesões referente ao uso prévio de pino intramedular no rádio. A montagem do fixador foi realizada com transfixação de pinos lisos em sua maioria angulados, cujas extremidades excedentes foram dobradas e estabilizadas com resina acrílica. em todos os casos, utilizou-se enxerto esponjoso autólogo fresco, após debridamento do foco de fratura. O tempo de permanência do aparelho variou entre 45 dias e 5 meses e a maior complicação foi o afrouxamento dos pinos transfixantes. A consolidação das fraturas ocorreu por formação de calo periosteal de mínimo a moderado, indicando boa rigidez da montagem.