990 resultados para Diagnostic category


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic accuracy and management recommendations of realtime teledermatology consultations using low-cost telemedicine equipment were evaluated. Patients were seen by a dermatologist over a video-link and a diagnosis and treatment plan were recorded. This was followed by a face-to-face consultation on the same day to confirm the earlier diagnosis and management plan. A total of 351 patients with 427 diagnoses participated. Sixty-seven per cent of the diagnoses made over the video-link agreed with the face-to-face diagnosis. Clinical management plans were recorded for 214 patients with 252 diagnoses. For this cohort, 44% of the patients were seen by the same dermatologist at both consultations, while 56% were seen by a different dermatologist. In 64% of cases the same management plan was recommended at both consultations; a sub-optimum treatment plan was recommended in 8% of cases; and in 9% of cases the video-link management plans were judged to be inappropriate. In 20% of cases the dermatologist was unable to recommend a suitable management plan by video-link. There were significant differences in the ability to recommend an optimum management plan by video-link when a different dermatologist made the reference management plan. The results indicate that a high proportion of dermatological conditions can be successfully managed by realtime teledermatology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We tested the hypothesis that evaluative bias in common ingroup contexts versus crossed categorization contexts can be associated with two distinct underlying processes. We reasoned that in common ingroup contexts, self-categorization, but not perceived complexity, would be positively related to intergroup bias. In contrast, in crossed categorization contexts, perceived complexity, but not self-categorization, would be negatively related to intergroup bias. In two studies, and in line with predictions, we found that while self-categorization and intergroup bias were related in common ingroup contexts, this was not the case in crossed categorization contexts. Moreover, we found that perceived category complexity, and not self-categorization, predicted bias in crossed categorization contexts. We discuss the implications of these findings for models of social categorization and intergroup bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In contrast to the multitude of studies on fungal PCR assay methods, little work has been reported evaluating Candida PCR performance when using whole blood compared with serum in candidaemic patients. Here, a comparison of the performance of whole-blood and serum specimens using a set of real-time PCR Candida species assays is described. Specimens were collected prospectively from non-neutropenic adults who were recruited to a diagnostic clinical trial, the primary purpose of which was to verify the performance of the assays using serum; in all, 104 participants also had whole-blood specimens submitted for analysis in addition to the serum specimen. Of these participants, 10 had laboratory-confirmed candidaemia and 94 were categorized as being 'unlikely' to have invasive Candida infection. PCR results from the whole-blood specimens are presented here and compared with the results from serum specimens in this subgroup among whom both specimen types were obtained contemporaneously. All participants with candidaemia were PCR-positive from serum samples; however, only seven were PCR-positive from whole blood. All specimens from patients in the 'unlikely' category were PCR-negative in both types of specimen. Moreover, DNA extraction from serum required 1 h; extraction from whole blood required approximately 3 h. These data tentatively suggest that, overall, serum is an appropriate specimen for Candida PCR for detection of candidaemia in non-neutropenic adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ineffective risk stratification can delay diagnosis of serious disease in patients with hematuria. We applied a systems biology approach to analyze clinical, demographic and biomarker measurements (n = 29) collected from 157 hematuric patients: 80 urothelial cancer (UC) and 77 controls with confounding pathologies.

Methods: On the basis of biomarkers, we conducted agglomerative hierarchical clustering to identify patient and biomarker clusters. We then explored the relationship between the patient clusters and clinical characteristics using Chi-square analyses. We determined classification errors and areas under the receiver operating curve of Random Forest Classifiers (RFC) for patient subpopulations using the biomarker clusters to reduce the dimensionality of the data.

Results: Agglomerative clustering identified five patient clusters and seven biomarker clusters. Final diagnoses categories were non-randomly distributed across the five patient clusters. In addition, two of the patient clusters were enriched with patients with ‘low cancer-risk’ characteristics. The biomarkers which contributed to the diagnostic classifiers for these two patient clusters were similar. In contrast, three of the patient clusters were significantly enriched with patients harboring ‘high cancer-risk” characteristics including proteinuria, aggressive pathological stage and grade, and malignant cytology. Patients in these three clusters included controls, that is, patients with other serious disease and patients with cancers other than UC. Biomarkers which contributed to the diagnostic classifiers for the largest ‘high cancer- risk’ cluster were different than those contributing to the classifiers for the ‘low cancer-risk’ clusters. Biomarkers which contributed to subpopulations that were split according to smoking status, gender and medication were different.

Conclusions: The systems biology approach applied in this study allowed the hematuric patients to cluster naturally on the basis of the heterogeneity within their biomarker data, into five distinct risk subpopulations. Our findings highlight an approach with the promise to unlock the potential of biomarkers. This will be especially valuable in the field of diagnostic bladder cancer where biomarkers are urgently required. Clinicians could interpret risk classification scores in the context of clinical parameters at the time of triage. This could reduce cystoscopies and enable priority diagnosis of aggressive diseases, leading to improved patient outcomes at reduced costs. © 2013 Emmert-Streib et al; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensitive and specific urinary biomarkers can improve patient outcomes in many diseases through informing early diagnosis. Unfortunately, to date, the accuracy and translation of diagnostic urinary biomarkers into clinical practice has been disappointing. We believe this may be due to inappropriate standardization of diagnostic urinary biomarkers. Our objective was therefore to characterize the effects of standardizing urinary levels of IL-6, IL-8, and VEGF using the commonly applied standards namely urinary creatinine, osmolarity and protein. First, we report results based on the biomarker levels measured in 120 hematuric patients, 80 with pathologically confirmed bladder cancer, 27 with confounding pathologies and 13 in whom no underlying cause for their hematuria was identified, designated “no diagnosis”. Protein levels were related to final diagnostic categories (p = 0.022, ANOVA). Osmolarity (mean = 529 mOsm; median = 528 mOsm) was normally distributed, while creatinine (mean = 10163 µmol/l, median = 9350 µmol/l) and protein (0.3297, 0.1155 mg/ml) distributions were not. When we compared AUROCs for IL-6, IL-8 and VEGF levels, we found that protein standardized levels consistently resulted in the lowest AUROCs. The latter suggests that protein standardization attenuates the “true” differences in biomarker levels across controls and bladder cancer samples. Second, in 72 hematuric patients; 48 bladder cancer and 24 controls, in whom urine samples had been collected on recruitment and at follow-up (median = 11 (1 to 20 months)), we demonstrate that protein levels were approximately 24% lower at follow-up (Bland Altman plots). There was an association between differences in individual biomarkers and differences in protein levels over time, particularly in control patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanostructure and molecular orientation play a crucial role in determining the functionality of organic thin films. In practical devices, such as organic solar cells consisting of donor-acceptor mixtures, crystallinity is poor and these qualities cannot be readily determined by conventional diffraction techniques, while common microscopy only reveals surface morphology. Using a simple nondestructive technique, namely, continuous-wave electron paramagnetic resonance spectroscopy, which exploits the well-understood angular dependence of the g-factor and hyperfine tensors, we show that in the solar cell blend of C-60 and copper phthalocyanine (CuPc)-for which X-ray diffraction gives no information-the CuPc, and by implication the C-60, molecules form nanoclusters, with the planes of the CuPc molecules oriented perpendicular to the film surface. This information demonstrates that the current nanostructure in CuPc:C-60 solar cells is far from optimal and suggests that their efficiency could be considerably increased by alternative film growth algorithms.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Scanning laser polarimetry (SLP) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the SLP for diagnosing glaucoma. METHODS: A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the SLP for glaucoma was performed. Two reviewers independently selected and appraised the manuscripts. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS: A total of 47 papers were identified of which the first 10 (from 1997 to 2000) and the last 10 articles (from 2004 to 2005) were appraised. Interobserver rating agreement of STARD items was high (85.5% agreement, ?=0.796). The number of STARD items properly reported ranged from 3/25 to 19/25. Only a quarter of studies (5/20) explicitly reported more than half of the STARD items. Important aspects of the methodology were often missing such as participant sampling (reported in 40% of manuscripts), masking of the readers of the index test and reference standard (reported in 20% of manuscripts), and estimation of uncertainty (eg, 95% confidence intervals, reported in 25% of manuscripts). There was a slight increase in the number of STARD items reported with time. CONCLUSIONS: The quality of reporting of diagnostic accuracy tests for glaucoma with SLP is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. © 2007 Lippincott Williams & Wilkins, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the diagnostic capability of tendency oriented perimetry (TOP) in glaucoma. METHODS. A): The diagnostic accuracy of mean defect (MD), square-root of the loss variance (sLV), and number of pathologic points (NPP) was calculated in 295 normal and 414 glaucoma eyes (179 early, 112 moderate, and 123 advanced) examined with TOP. B): Threshold fluctuation (F) and its relationship with the loss variance (LV) was measured in 34 normal and 33 glaucoma eyes (mean MD=3 dB; SD=3.9) for TOP and for full-threshold perimetry (FT). C): Twenty-eight eyes with stable glaucoma (mean MD=9.5 dB; SD=7.2) were examined six times to quantify LV error. D): TOP and FT were tested with the simulation program PeriSim using different behavior models. RESULTS. A): The best diagnostic index in early glaucoma (MD

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. Scanning laser tomography with the Heidelberg retina tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) has been proposed as a useful diagnostic test for glaucoma. This study was conducted to evaluate the quality of reporting of published studies using the HRT for diagnosing glaucoma. METHODS. A validated Medline and hand search of English-language articles reporting on measures of diagnostic accuracy of the HRT for glaucoma was performed. Two reviewers selected and appraised the papers independently. The Standards for Reporting of Diagnostic Accuracy (STARD) checklist was used to evaluate the quality of each publication. RESULTS. A total of 29 articles were included. Interobserver rating agreement was observed in 83% of items (? = 0.76). The number of STARD items properly reported ranged from 5 to 18. Less than a third of studies (7/29) explicitly reported more than half of the STARD items. Descriptions of key aspects of the methodology were frequently missing. For example, the design of the study (prospective or retrospective) was reported in 6 of 29 studies, and details of participant sampling (e.g., consecutive or random selection) were described in 5 of 29 publications. The commonest description of diagnostic accuracy was sensitivity and specificity (25/29) followed by area under the ROC curve (13/29), with 9 of 29 publications reporting both. CONCLUSIONS. The quality of reporting of diagnostic accuracy tests for glaucoma with HRT is suboptimal. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies. Copyright © Association for Research in Vision and Ophthalmology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the quality of reporting of all diagnostic studies published in five major ophthalmic journals in the year 2002 using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative parameters. Methods: Manual searching was used to identify diagnostic studies published in 2002 in five leading ophthalmic journals, the American Journal of Ophthalmology (AJO), Archives of Ophthalmology (Archives), British Journal of Ophthalmology (BJO), Investigative Ophthalmology and Visual Science (IOVS), and Ophthalmology. The STARD checklist of 25 items and flow chart was used to evaluate the quality of each publication. Results: A total of 16 publications were included (AJO = 5, Archives = 1, BJO = 2, IOVS = 2, and Ophthalmology = 6). More than half of the studies (n = 9) were related to glaucoma diagnosis. Other specialties included retina (n = 4) cornea (n = 2), and neuro-ophthalmology (n = 1). The most common description of diagnostic accuracy was sensitivity and specificity values, published in 13 articles. The number of fully reported items in evaluated studies ranged from eight to 19. Seven studies reported more than 50% of the STARD items. Conclusions: The current standards of reporting of diagnostic accuracy tests are highly variable. The STARD initiative may be a useful tool for appraising the strengths and weaknesses of diagnostic accuracy studies.