949 resultados para Corona del diente


Relevância:

20.00% 20.00%

Publicador:

Resumo:

pplication of pulsed plasma for gas cleaning is gaining prominence in recent years mainly from the energy consideration point of view. Normally, gas treatment is carried out, at or above room temperature, by a conventional dry type corona reactor. However, this treatment is still inadequate in the removal of certain stable gases present in the exhaust/flue gas mixture. The authors report some interesting results of the treatment of such stable gases with pulsed plasma at very low ambient temperature. Also reported in the paper is an improvement in DeNO/DeNOx efficiency using unconventional wet-type reactors, designed and fabricated by the authors, operating at different ambient temperatures. Apart from laboratory tests on simulated gas mixtures, field tests were also carried out on the exhaust gas of a 8 kW diesel engine. Further, an attempt was made to test the feasibility of a helical wire as a corona electrode in place of the conventional straight wire electrode. A comparative analysis of the various tests is presented together with a note on the energy consideration

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A plasma-assisted catalytic reactor was used to remove nitrogen oxides (NOx) from diesel engine exhaust operated under different load conditions. Initial studies were focused on plasma reactor (a dielectric barrier discharge reactor) treatment of diesel exhaust at various temperatures. The nitric oxide (NO) removal efficiency was lowered when high temperature exhaust was treated using plasma reactor. Also, NO removal efficiency decreased when 45% load exhaust was treated. Studies were then made with plasma reactor combined with a catalytic reactor consisting of a selective catalytic reduction (SCR) catalyst, V2O5/TiO2. Ammonia was used as a reducing agent for SCR process in a ratio of 1:1 to NOx. The studies were focused on temperatures of the SCR catalytic reactor below 200°C. The plasma-assisted catalytic reactor was operated well to remove NOx under no-load and load conditions. For an energy input of 96 J/l, the NOx removal efficiencies obtained under no-load and load conditions were 90% and 72% respectively at an exhaust temperature of 100°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Application of pulsed plasma for gas cleaning is gaining prominence in recent years mainly from the energy consideration point of view. Normally, gas treatment is carried out, at or above room temperature, by a conventional dry type corona reactor. However, this treatment is still inadequate in the removal of certain stable gases present in the exhaust/flue gas mixture. The authors report some interesting results of the treatment of such stable gases with pulsed plasma at very low ambient temperature. Also reported in the paper is an improvement in DeNO/DeNOx efficiency using unconventional wet-type reactors, designed and fabricated by the authors, operating at different ambient temperatures. Apart from laboratory tests on simulated gas mixtures, field tests were also carried out on the exhaust gas of a 8 kW diesel engine. Further, an attempt was made to test the feasibility of a helical wire as a corona electrode in place of the conventional straight wire electrode. A comparative analysis of the various tests is presented together with a note on the energy consideration

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed study on the removal of oxides of nitrogen (NOx) from the exhaust of a stationary diesel engine was carried out using non-thermal plasma (dielectric barrier discharge) process. The objective of the study was to explore the effect of different voltage energizations and exhaust composition on the NOx removal process. Three types of voltage energizations, namely AC, DC and Pulse were examined. Due to the ease of generation of high voltage AC/DC electrical discharges from automobile/Vehicular battery supply for possible retrofitting in exhaust cleaning circuit, it was found relevant to investigate individual energisation cases in detail for NOx removal. AC and Pulse energisations exhibit a superior NOx removal efficiency compared to DC energisation. However,Pulse energisation is found to be more energy efficient. Experiments were further carried out with filtered/ unfiltered (raw) exhaust under pulse energisations. The results were discussed with regard to NOx removal, energy consumption and formation of by-products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The components of EHV/UHV lines and substations can produce significant corona. To limit the consequent Radio Interference and Audible Noise on these systems, suitable corona control rings are employed. The shapes of these rings could vary from circular to rectangular with smooth bends. Many manufacturers seem to adopt trial and error method for arriving at the final design. As such neither the present testing standard nor the final design adopted consider the practical scenario like corona produced by deposition of dirt, bird droppings, etc. The present work aims to make a first step in addressing this practically important problem. This requires an accurate evaluation of the electric field and a reliable method for the evaluation of corona inception. Based on a thorough survey of pertinent literature, the critical avalanche criteria as applicable to large electrodes, has been adopted. Taking the rain drop on the surface as the biggest protrusion, conducting protrusions modeled as semi-ellipsoid is considered as representative for deposition of dust or the boundary of bird droppings etc. Through examples of 4 00 kV and 765 kV class toroidal corona rings, the proposed method is demonstrated. This work is believed to be useful to corona ring manufacturers for EHV/UHV systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Radio Interference (RI) from electric power transmission line hardware, if not controlled, poses serious electromagnetic interference to system in the vicinity. The present work mainly concerns with the RI from the insulator string along with the associated line hardware. The laboratory testing for the RI levels are carried out through the measurement of the conducted radio interference levels. However such measurements do not really locate the coronating point, as well as, the mode of corona. At the same time experience shows that it is rather difficult to locate the coronating points by mere inspection. After a thorough look into the intricacies of the problem, it is ascertained that the measurement of associated ground end currents could give a better picture of the prevailing corona modes and their intensities. A study on the same is attempted in the present work. Various intricacies of the problem,features of ground end current pulses and its correlation with RI are dealt with. Owing to the complexity of such experimental investigations, the study made is not fully complete nevertheless it seems to be first of its kind.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corona discharge is recognized as one of the mechanisms that can influence the surface hydrophobicity of Silicone Rubber (SR) because of the chemical changes that occur on its surface. In this study SR samples were exposed to positive and negative DC corona for 25 and 50 hours using a needle-plane electrode system. Hydrophobicity changes were monitored using a sessile drop contact angle measurement facility. The physical changes on the surface were studied using Scanning Electron Microscopy (SEM) and surface roughness measurements. The effect of positive dc corona was found to be different from that of negative dc corona. Significant surface degradation and loss of hydrophobicity was found in the case of negative dc corona exposed samples. Significant improvement in the above mentioned properties were obtained by adding small quantities of nSIL into the SR matrix.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corona is an unavoidable phenomena in high voltage power transmission system, in spite of suitably designed insulator accessories and transmission line hardware. It is a proven fact that the continuous occurrence of corona can subject the polymeric insulator to a severe degradation. Further, moisture in the air has a positive influence on the corona activity. This paper presents the methodology to evaluate the corona performance of the silicone rubber housing material with simultaneous application of cold fog. Analysis conducted after corona treatment by the Fourier Transform Infrared Spectroscopy (FTIR) present an interesting results showing a higher hydroxylation of sample surface under the moisture application than in the normal condition for both AC and DC excitation. FTIR spectrum also indicates the presence of nitric acid on the treated surface with coldfog application. Results obtained from SEM analysis are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With increasing energy demand, it necessitates to generate and transmit the electrical power with minimal losses. High voltage power transmission is the most economical way of transmitting bulk power over long distances. Transmission insulator is one of the main components used as a mechanical support and to electrically isolate the conductor from the tower. Corona from the hardware and conductors can significantly affect the performance of the polymeric insulators. In the present investigation a methodology is presented to evaluate the corona performance of the polymeric shed material under different environment conditions for both ac and dc excitation. The results of the comprehensive analysis on various polymeric samples and the power released from the corona electrode for both the ac and dc excitation are presented. Some interesting results obtained from the chemical analysis confirmed the presence of nitric acid species on the treated sample which in long term will affect the strength of the insulator, also the morphological changes were found to be varying for different experimental conditions. (C) 2015 The Authors. Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corona discharges resulting from the metal parts of insulators and the line hardware affect the long term performance of the polymeric insulators used for outdoor application and can lead to its eventual failure. The authors previous work, involved in developing a new methodology to evaluate the performance of polymeric shed materials subjected to corona stresses in the presence of natural fog condition, results revealed more surface hydroxylation thereby resulting in more loss of hydropobhicity. With the increase in industrialization, there is an increase in acidic component of the rain as well as the fog (moisture). The present work, reports the effect of acid fog on the corona performance of the polymeric insulators for both AC and DC excitation, interesting results are obtained. A comparison of the experimental investigations revealed that the acidic fog has more effect than that of the normal fog. This fact has been confirmed by physico-chemical analysis like the scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), x-ray photoelectron spectroscopy (XPS) and contact angle measurement. The effect of DC corona is found to be lesser in comparison with the AC; however the hydroxylation induced by the DC corona under the presence of fog is similar with that of AC excitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La presente investigación fue realizada en la micro cuenca el Coyote ubicada en el municipio de Condega Departamento de Estelí, como parte del convenio de la Universidad Nacional Agraria con el proyecto CARE/MARENA/P IMCHAS, con el fin de mejorar las condiciones ambientales de la micro cuenca. La intención de la investigación fue evaluar la composición florística del bosque ripario de la parte alta, media y baja de la micro cuenca donde se desarrolló en tres etapas: re conocimiento del área, realización del inventario forestal y diagnóstico de la vegetación arbórea. La metodología que se utilizó en dicho estudio fue la aplicación de un inventario forestal con un área muestreada de 0.24 ha (inventario sis temá tico con par celas de 0.01 ha cada una, con un a intensidad de muestreo 0.08 %. La composición florística existente en el bosque la conforman un total de 66 individuos mayores a los 10cm de DAP equivalentes a 31 especies arbóreas, y 18 familias botánicas, sobresaliendo la Fabaceae (5), Mimosaceae (5) y Anacardiaceae (3 especies). En las clases diamétricas la mayoría de los individuos se encuentran en la categoría diamétrica de 10 - 19.9 (clases 1) siendo la parte alta el sitio que más árboles posee con (66.66 arb ha - 1 ) y la parte media con 20.83 arb ha - 1 la parte alta con el m enor número de árboles 8.33 arb ha - 1 en la categoría de 20 - 39.9 (clase 2 y 3), donde el mayor número de individuos se encuentran en la parte baja de la microcuenca con 66.66 arb ha - 1 y la parte me dia con 20.83 arb ha - 1 , la parte alta con el men or número de árboles 8.33 arb ha - 1 . Las categorías silviculturales el mayor porcentaje de árboles presentan fuste recto sin daño evidente (categoría 1), distribuidos de la siguiente manera 13.64 % en la parte alta, 10.61 % en la parte media y 16.67 % en la parte baja. En la categoría de iluminación vertical plena el may or porcentaje de árboles se encuentra en la (categoría 2), distribuidos para la parte alta y la parte media el 4.55% y la parte baja con el 13.64% . Encontramos en la parte baja el 18.18% de árboles sin lianas (categorí a 1), observándose para la parte media el 10.61% y la parte alta el 15.15%, en esta misma categoría. En cuanto a la vigorosidad de los árboles en el bosque ripario la parte baja de la microcuenca tiene el mayor porcentaje con 17.67%, con buen follaje y buena vitalidad aparente, sin daño que afecte su crecimiento (categoría 1), seguida de la parte alta con 13.64% y la parte media con 12.12%. La regeneración natural e n (área muestr eada 0.024 ), consiguiente fue de 541.7 plantas ha - 1 , representada por 10 familias botánicas (Euphorbiaceae, Sterculiaceae, Anacardiaceae, Rutaceae, Mimosaceae, Fagaceae, Myrtaceae, Arecaceae, Verbenaceae y Bignonaceae).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo fue evaluar el establecimiento de tres especies forestales de valor comercial, Swietenia humilis, Cedrela odorata y Pachira quinata, como medida de enriquecimiento del bosque seco secundario de Nandaime, como medida de enriquecimiento del bosque seco. Se establecieron tres parcelas cuadradas con área de 625 m² (25 m x 25 m) y un espaciamiento de 3 m x 3 m entre plantas y líneas. Se plantaron 15 plantas por especie para un total de 45 individuos por parcelas, cada parcela con un porcentaje de cobertura de dosel correspondiente a: 0 a 20%, 20 a 50% y 50% a más. Las variables medidas fueron sobrevivencia, daños por insectos. Se obtuvo un porcentaje general de sobrevivencia de 53%, C. odorata es la especie que presentó valores más bajos (0%) en la cobertura0 a 20% y mayor de 50, los principales daños causados fueron notorios en los meses secos al final del período evaluado, principalmente en la cobertura mayor a 50%. Con los resultados obtenidos de las tres especies evaluadas se concluye que las especies P. quinata y Swietenia humilis, pueden utilizarse en plantaciones de enriquecimiento forestal con cobertura inferior al a 50% mientras C. odorata siempre y cuando se establezca un sistema de monitoreo y control de agentes de agentes que incrementan el riesgo de mortalidad de la especie.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La cuantificación del cambio de uso del suelo presenta aún altos niveles de incertidumbre, lo que repercute por ejemplo en la estimación de las emisiones de CO 2 . En este estudio se desarrollaron métodos, basados en imágenes de satélite y trabajo de campo, para estimar la tasa de cambio de la cobertura y uso del suelo, y las emisiones de CO 2 en la subcuenca río Dipilto, Nueva Segovia. La superficie de los tipos de vegetación se determinó con imágenes Landsat. Se utilizaron datos de carbono de nueve parcelas de muestreo en bosque de pino que fueron correlacionadas, para establecer un modelo de regresión lineal con el objetivo de estimar el Stock de Carbono. La sobreposición y algebra de mapas se utilizó para el escenario de emisiones de CO 2 . El análisis con imágenes de los años 1993, 2000 y 2011 reveló que durante es tos 18 años la velocidad a la que se perdieron los bosques latifoliados cerrado fue variable. Durante los primeros 7 años (1993 a 2000) se registró un aumento de 99.95 ha , que corresponde a una tasa de deforestación de - 1.45 % anual. Durante los últimos once años (2000 a 2011) esta cantidad cambió totalmente, ya que se eliminaron 331.76 h a , que corresponde a una tasa de deforestación anual de 3.41 %. Finalmente considerando el periodo de análisis, se transformaron más de 232.01 h a por año, correspondiente a u na tasa de deforestación anual de 1.55 %. La imagen de 2011 demostró que las reservas o Stock de C oscila entre 40 - 150 t/ha. Este intervalo de valores fue estimado por un modelo de regresión con razonable ajuste (R2 = 0.73 ), cuyas variables independientes fueron la reflectancia de las distintas bandas como índices de vegetación e infrarrojo cercano. Las pérdidas de C se estimaron en intervalos 1 - 191 t/h a en 20.76% del área. El 32.85% del área se mantuvo estable y 46.39% ganancias de 1 - 210 t/ha. La combinación de imágenes de resolución espacial media como son las de la serie Landsat para definir trayectorias de cambio de la cobertura del suelo, es una opción viable para la solución de interrogantes relacionadas con el cambio climático, tales como la estimación de las emisiones de CO 2 derivadas del cambio de uso del suelo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En la microcuenca El Coyote localizada en el municipio de Condega, Estelí, se evaluó la calidad del agua superficial de sde febrero del 2010 a febrero del 2011. El propósito fue la identificación de indicadores que faciliten la vigilancia y monitoreo de la calidad del agua . Se integró un sistema multimétrico utilizando las características físicoquímicas y bacteriológicas, macro invertebrados acuáticos, la caracterización morfométrica de la microcuenca y la información resultante a nivel de comunidad (cambios en el uso del suelo). En la determinación de la relación de la calidad del agua con la estructura de la macrofauna acuática (macroinvertebrados) se usó el método Biological Monitoring Working Party (BMWP/Col ) . La microcuenca tiene 144 afluentes con una forma oval - oblonga - alargada, y su curva hipsométrica refleja un estado de equilibrio relativo de juvenil a madurez. El uso del suelo es inadecuado y su entorno natural fue valorado como subóptimo. Aunque los parámetros fisico químicos indicaron que las aguas son alcalinas, con un nivel aceptable de oxigeno disuelto, categorizadas según el Diagrama de Riverside como aguas aptas par a riego (C2 - S1), y aceptables según valores determinados para DBO 5 y DQO; sin embargo, requieren de un tratamiento de descontaminación previo a su uso doméstico y agropecuario. Además, debido a la presencia de coliformes fecales estas aguas no están aptas para consumo humano . Los macroinvertebrados varían, según la estacionalidad, en riqueza, abundancia y distribución, presentando una disminución en el número de individuos en la época lluviosa (t= 5.21, p<2.18E - 07). E l 6 8 . 91 % de los macroinvertebrados bioin dicadores se distribuyeron en cinco familias : Leptohyphidae , Baetidae , Hydropsychidae , Chironomidae y Physidae , siendo el cariotipo piedra el que present ó mayor diversidad y abundancia . El promedio del BMWP /Col fue de 60.06, indicando una calidad del agua entre dudosa y aceptable , y el índice ASPT de 6.71 señala una contaminación moderada ; estos resultados coincide n con los obtenidos utilizando la batería de indicadores fisicoquímicos y bacteriológicos .