820 resultados para Composite tapered beams
Resumo:
Reconstruction of defects in the craniomaxillofacial (CMF) area has mainly been based on bone grafts or metallic fixing plates and screws. Particularly in the case of large calvarial and/or craniofacial defects caused by trauma, tumours or congenital malformations, there is a need for reliable reconstruction biomaterials, because bone grafts or metallic fixing systems do not completely fulfill the criteria for the best possible reconstruction methods in these complicated cases. In this series of studies, the usability of fibre-reinforced composite (FRC) was studied as a biostable, nonmetallic alternative material for reconstructing artificially created bone defects in frontal and calvarial areas of rabbits. The experimental part of this work describes the different stages of the product development process from the first in vitro tests with resin-impregnated fibrereinforced composites to the in vivo animal studies, in which this FRC was tested as an implant material for reconstructing different size bone defects in rabbit frontal and calvarial areas. In the first in vitro study, the FRC was polymerised in contact with bone or blood in the laboratory. The polymerised FRC samples were then incubated in water, which was analysed for residual monomer content by using high performance liquid chromatography (HPLC). It was found that this in vitro polymerisation in contact with bone and blood did not markedly increase the residual monomer leaching from the FRC. In the second in vitro study, different adhesive systems were tested in fixing the implant to bone surface. This was done to find an alternative implant fixing system to screws and pins. On the basis of this study, it was found that the surface of the calvarial bone needed both mechanical and chemical treatments before the resinimpregnated FRC could be properly fixed onto it. In three animal studies performed with rabbit frontal bone defects and critical size calvarial bone defect models, biological responses to the FRC implants were evaluated. On the basis of theseevaluations, it can be concluded that the FRC, based on E-glass (electrical glass) fibres forming a porous fibre veil enables the ingrowth of connective tissues to the inner structures of the material, as well as the bone formation and mineralization inside the fibre veil. Bone formation could be enhanced by using bioactive glass granules fixed to the FRC implants. FRC-implanted bone defects healed partly; no total healing of defects was achieved. Biological responses during the follow-up time, at a maximum of 12 weeks, to resin-impregnated composite implant seemed to depend on the polymerization time of the resin matrix of the FRC. Both of the studied resin systems used in the FRC were photopolymerised and the heat-induced postpolymerisation was used additionally.
Resumo:
Many colour ornaments are composite traits consisting of at least four components, which themselves may be more complex, determined by independent evolutionary pathways, and potentially being under different environmental control. To date, little evidence exists that several different components of colour elaboration are condition dependent and no direct evidence exists that different ornamental components are affected by different sources of variation. For example, in carotenoid-based plumage colouration, one of the best-known condition-dependent ornaments, colour elaboration stems from both condition-dependent pigment concentration and structural components. Some environmental flexibility of these components has been suggested, but specifically which and how they are affected remains unknown. Here, we tested whether multiple colour components may be condition dependent, by using a comprehensive 3 × 2 experimental design, in which we carotenoid supplemented and immune challenged great tit nestlings (Parus major) and quantified effects on different components of colouration. Plumage colouration was affected by an interaction between carotenoid availability and immune challenge. Path analyses showed that carotenoid supplementation increased plumage saturation via feather carotenoid concentration and via mechanisms unrelated to carotenoid deposition, while immune challenge affected feather length, but not carotenoid concentration. Thus, independent condition-dependent pathways, affected by different sources of variation, determine colour elaboration. This provides opportunities for the evolution of multiple signals within components of ornamental traits. This finding indicates that the selective forces shaping the evolution of different components of a composite trait and the trait's signal content may be more complex than believed so far, and that holistic approaches are required for drawing comprehensive evolutionary conclusions.
Resumo:
A method for generating beams with arbitrary polarization and shape is proposed. Our design requires the use of a Mach-Zehnder set-up combined with translucent liquid crystal displays in each arm of the interferometer; in this way, independent manipulation of each transverse beam components is possible. The target of this communication is to develop a numerical procedure for calculating the holograms required for dynamically encode any amplitude value and polarization state in each point of the wavefront. Several examples demonstrating the capabilities of the method are provided.
Resumo:
In recent years there has been growing interest in composite indicators as an efficient tool of analysis and a method of prioritizing policies. This paper presents a composite index of intermediary determinants of child health using a multivariate statistical approach. The index shows how specific determinants of child health vary across Colombian departments (administrative subdivisions). We used data collected from the 2010 Colombian Demographic and Health Survey (DHS) for 32 departments and the capital city, Bogotá. Adapting the conceptual framework of Commission on Social Determinants of Health (CSDH), five dimensions related to child health are represented in the index: material circumstances, behavioural factors, psychosocial factors, biological factors and the health system. In order to generate the weight of the variables, and taking into account the discrete nature of the data, principal component analysis (PCA) using polychoric correlations was employed in constructing the index. From this method five principal components were selected. The index was estimated using a weighted average of the retained components. A hierarchical cluster analysis was also carried out. The results show that the biggest differences in intermediary determinants of child health are associated with health care before and during delivery.
Resumo:
Diplomityössä perehdytään lujitemuovikomposiitteihin sekä niiden valmistusmenetelmiin. Tavoitteena on kehittää lujitemuovinen paperikoneen kaavinterän kannatinpalkkirakenne. Suunniteltavalla tuotteella pyritään korvaamaan perinteisesti teräksestä valmistetut paperikoneiden kaavinterän pidikepalkit paremmin tarkoitukseen sopivalla lujitemuovisella rakenteella sekä parantamaan jo tuotannossa olevan tuotteen ominaisuuksia. Työssä selvitetään tuotteen vaatimukset, joiden pohjalta laaditaan tuotteen vaatimusprofiili ja suoritetaan materiaalinvalinta perustuen ominaisarvovertailuihin. Suunnitteluosiossa tutkitaan eri rakenneratkaisujen soveltuvuutta kohteeseen. Tutkimustulosten perusteella saatiin kattava kuva eri materiaalien soveltuvuudesta kohteeseen sekä kehitettiin rakenneratkaisu, joka täyttää tuotteelta vaaditut ominaisuudet. Tutkimustulosten pohjalta syntyi myös uuden tyyppinen rakenne jolla saavutetaan huomattavaa tilansäästöä perinteisiin rakenneratkaisuihin nähden. Tämän rakenneratkaisun kehitystyötä on tarkoitus jatkaa.
Resumo:
Fiber-reinforced composite as oral implant material: Experimental studies of glass fiber and bioactive glass in vitro and in vivo Department of Prosthetic Dentistry and Biomaterials Science, Institute of Dentistry, University of Turku, Turku, Finland 2008. Biocompatibility and mechanical properties are important variables that need to be determined when new materials are considered for medical implants. Special emphasis was placed on these characteristics in the present work, which aimed to investigate the potential of fiber-reinforced composite (FRC) material as an oral implant. Furthermore, the purpose of this study was to explore the effect of bioactive glass (BAG) on osseointegration of FRC implants. The biocompatibility and mechanical properties of FRC implants were studied both in vitro and in vivo. The mechanical properties of the bulk FRC implant were tested with a cantilever bending test, torsional test and push-out test. The biocompatibility was first evaluated with osteoblast cells cultured on FRC substrates. Bone bonding was determined with the mechanical push-out test and histological as well as histomorplanimetric evaluation. Implant surface was characterized with SEM and EDS analysis. The results of these studies showed that FRC implants can withstand the static load values comparably to titanium. Threaded FRC implants had significantly higher push-out strength than the threaded titanium implants. Cell culture study revealed no cytotoxic effect of FRC materials on the osteoblast-like-cells. Addition of BAG particles enhanced cell proliferation and mineralization of the FRC substrates The in vivo study showed that FRC implants can withstand static loading until failure without fracture. The results also suggest that the FRC implant is biocompatible in bone. The biological behavior of FRC was comparable to that of titanium after 4 and 12 weeks of implantation. Furthermore, addition of BAG to FRC implant increases peri-implant osteogenesis and bone maturation.
Resumo:
This paper presents a composite index of early childhood health using a multivariate statistical approach. The index shows how child health varies across Colombian departments, -administrative subdivisions-. In recent years there has been growing interest in composite indicators as an efficient analysis tool and a way of prioritizing policies. These indicators not only enable multi-dimensional phenomena to be simplified but also make it easier to measure, visualize, monitor and compare a country’s performance in particular issues. We used data collected from the Colombian Demographic and Health Survey, DHS, for 32 departments and the capital city, Bogotá, in 2005 and 2010. The variables included in the index provide a measure of three dimensions related to child health: health status, health determinants and the health system. In order to generate the weight of the variables and take into account the discrete nature of the data, we employed a principal component analysis, PCA, using polychoric correlation. From this method, five principal components were selected. The index was estimated using a weighted average of the components retained. A hierarchical cluster analysis was also carried out. We observed that the departments ranking in the lowest positions are located on the Colombian periphery. They are departments with low per capita incomes and they present critical social indicators. The results suggest that the regional disparities in child health may be associated with differences in parental characteristics, household conditions and economic development levels, which makes clear the importance of context in the study of child health in Colombia.
Resumo:
Automated Fiber Placement is being extensively used in the production of major composite components for the aircraft industry. This technology enables the production of tow-steered panels, which have been proven to greatly improve the structural efficiency of composites by means of in-plane stiffness variation and load redistribution. However, traditional straight-fiber architectures are still preferred. One of the reasons behind this is related to the uncertainties, as a result of process-induced defects, in the mechanical performance of the laminates. This experimental work investigates the effect of the fiber angle discontinuities between different tow courses in a ply on the un-notched and open-hole tensile strength of the laminate. The influence of several manufacturing parameters are studied in detail. The results reveal that 'ply staggering' and '0% gap coverage' is an effective combination in reducing the influence of defects in these laminates
Resumo:
The aim of this paper is to provide a formal framework for designing highly focused fields with specific transversal features when the incoming beam is partially polarized. More specifically, we develop a field with a transversal component that remains unpolarized in the focal area. Moreover, its longitudinal component exhibits non-zero values on axis. Special attention is paid to the design of the input beam and the development of the experiment. The implementation of such fields is possible by using an interferometric setup combined with the use of digital holography techniques. Experimental results are compared with those obtained numerically.
Resumo:
Bioactive glasses are surface-active ceramic materials which support and accelerate bone growth in the body. During the healing of a bone fracture or a large bone defect, fixation is often needed. The aim of this thesis was to determine the dissolution behaviour and biocompatibility of a composite consisting of poly(ε-caprolactone-co-DL-lactide) and bioactive glass (S53P4). In addition the applicability as an injectable material straight to a bone defect was assessed. In in vitro tests the dissolution behaviour of plain copolymer and composites containing bioactive glass granules was evaluated, as well as surface reactivity and the material’s capability to form apatite in simulated body fluid (SBF). The human fibroblast proliferation was tested on materials in cell culture. In in vivo experiments, toxicological tests, material degradation and tissue reactions were tested both in subcutaneous space and in experimental bone defects. The composites containing bioactive glass formed a unified layer of apatite on their surface in SBF. The size and amount of glass granules affected the degradation of polymer matrix, as well the material’s surface reactivity. In cell culture on the test materials the human gingival fibroblasts proliferated and matured faster compared with control materials. In in vitro tests a connective tissue capsule was formed around the specimens, and became thinner in the course of time. Foreign body cell reactions in toxicological tests were mild. In experimental bone defects the specimens with a high concentration of small bioactive glass granules (<45 μm) formed a dense apatite surface layer that restricted the bone ingrowth to material. The range of large glass granules (90-315 μm) with high concentrations formed the best bonding with bone, but slow degradation on the copolymer restricted the bone growth only in the superficial layers. In these studies, the handling properties of the material proved to be good and tissue reactions were mild. The reactivity of bioactive glass was retained inside the copolymer matrix, thus enabling bone conductivity with composites. However, the copolymer was noticed to degradate too slowly compared with the bone healing. Therefore, the porosity of the material should be increased in order to improve tissue healing.
Resumo:
Eighteen circular blocks of resins cured either by a LED or a halogen lamp (20, 40 and 60 s), had their top (T) and bottom (B) surfaces studied using a FT-Raman spectrometer. Systematic changes in the intensity of the methacrylate C=C stretching mode at 1638 cm-1 as a function of exposure duration were observed. The calculated degree of conversion (DC) ranged from 45.0% (B) to 52.0% (T) and from 49.0% (B) to 55.0% (T) for the LED and halogen lamp, respectively. LED and halogen light produced similar DC values with 40 and 60 s of irradiation.
Resumo:
In terms of the Fourier spectrum, a simple but general analytical expression is given for the evanescent field associated to a certain kind of non-paraxial exact solutions of the Maxwell equations. This expression enables one to compare the relative weight of the evanescent wave with regard to the propagating field. In addition, in those cases in which the evanescent term is significant, the magnitude of the field components across the transverse profile (including the evanescent features) can be determined. These results are applied to some illustrative examples.
Resumo:
The development of load-bearing osseous implant with desired mechanical and surface properties in order to promote incorporation with bone and to eliminate risk of bone resorption and implant failure is a very challenging task. Bone formation and resoption processes depend on the mechanical environment. Certain stress/strain conditions are required to promote new bone growth and to prevent bone mass loss. Conventional metallic implants with high stiffness carry most of the load and the surrounding bone becomes virtually unloaded and inactive. Fibre-reinforced composites offer an interesting alternative to metallic implants, because their mechanical properties can be tailored to be equal to those of bone, by the careful selection of matrix polymer, type of fibres, fibre volume fraction, orientation and length. Successful load transfer at bone-implant interface requires proper fixation between the bone and implant. One promising method to promote fixation is to prepare implants with porous surface. Bone ingrowth into porous surface structure stabilises the system and improves clinical success of the implant. The experimental part of this work was focused on polymethyl methacrylate (PMMA) -based composites with dense load-bearing core and porous surface. Three-dimensionally randomly orientated chopped glass fibres were used to reinforce the composite. A method to fabricate those composites was developed by a solvent treatment technique and some characterisations concerning the functionality of the surface structure were made in vitro and in vivo. Scanning electron microscope observations revealed that the pore size and interconnective porous architecture of the surface layer of the fibre-reinforced composite (FRC) could be optimal for bone ingrowth. Microhardness measurements showed that the solvent treatment did not have an effect on the mechanical properties of the load-bearing core. A push-out test, using dental stone as a bone model material, revealed that short glass fibre-reinforced porous surface layer is strong enough to carry load. Unreacted monomers can cause the chemical necrosis of the tissue, but the levels of leachable resisidual monomers were considerably lower than those found in chemically cured fibre-reinforced dentures and in modified acrylic bone cements. Animal experiments proved that surface porous FRC implant can enhance fixation between bone and FRC. New bone ingrowth into the pores was detected and strong interlocking between bone and the implant was achieved.