989 resultados para Composite Resins


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The pigmentation of indirect composite resins has been one of the most common reasons that lead the restorative treatment to failure. The purpose of this study was to investigate the effect of different solutions on color stability of indirect composite resins. Five brands of indirect composite resins were tested: Adoro, Resilab, Cristobal, Sinfony and Epricord. The samples were immerged in eleven solutions (n=10): common liquid foods (coke soft drink, red wine, coffee and orange juice), mounthrinses (Listerine, Oral-B, Colgate Plax and Periogard) and bleaching agents (carbamide peroxide 16%, 7.5% and hydrogen peroxide 38%) and artificial saliva (control group). The color was measured by a spectrophotometer before and after 7, 14 and 21 days of immersion in common liquid foods, after 12, 24, 36 and 60 hours of immersion in mounthrinses and after 7 and 14 days of immersion in bleaching agents. The Cristobal and Adoro resins showed highest values of ΔE statistically significant compared to the others resin brands. Adoro’s ΔE values changed significantly after the immersion process in red wine and coffee and also between periods measured. The resins Cristobal and Sinfony showed the highest values of ΔE after the immersion process in Listerine with difference statistically significant in comparison to control group. Besides, there was difference statistically significant of the ΔE values  for  Cristobal  after  immersion  in hydrogen peroxide 7,5% in comparison to control group. It can be conclude that all the solutions promoted color change on the indirect composite resins. However, ΔE values  are  whitin  the  values clinically acceptable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A case report of a patient who presents as chief complaint presence of stained restorations in the anterior teeth. After analysis and discussion of the clinical therapeutic approaches to be adopted, it was observed the presence of type class IV restorations on teeth 11 and 21, due to an oblique coronal fracture in the past. But the patient was not satisfied with the aesthetic result, then where was planned the realization of the removal of the restorations, for subsequently be used direct restorative materials for the correction of form, function and esthetics. The final result showed that the restorations were able to return the form, function and aesthetic dental, thereby evidencing the proven development of restorative dentistry in the solution of aesthetic problems.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective was to evaluate the effect of thermocycling on the color variation of three different composite resins . We studied was Resin Enamel on 3 levels : ( Esthetic X , Opallis and Venus ) ; Resin Dentin in three levels : ( Esthetic X , Opallis and Venus ) and Thermocycling on level 1 : ( 3,000 cycles ) ; variable was the change of color gauged by spectrophotometry . 60 specimens , subdivided into 6 groups were made : GI - Esthetic X Enamel ; GII - Esthetic X dentin ; GIII - Opallis Enamel ; GIV - Opallis dentin ; GV - Enamel and GVI Venus - Venus dentin . The specimens were prepared with a matrix to standardize samples . The inserts of incrementally resins and polymerized with a halogen light Ultralux unit ( Dabi Atlante , Brazil ) with a power of 450mW / cm ² . After fabrication , underwent color reading with a UV Visible Spectrophotometer reflection , UV -2450 ( Shimadzu , Kyoto , Japan ) , with the changes calculated by the system CIE L * a * b * . Then isolates were stored in artificial saliva at 35 ° C ± 2 ° C during 3 months containers being subjected to the effects of thermal cycling for 3000 cycles over the range of 5C to 55C . Again subjected to chromatic evaluation. For the analysis of the results of color change of the studied resins was applied ANOVA two factors at 5 % . The results showed a statistically equal resins enamel GI and GV ( p = 0.79 ) ; the same was not observed for GI and G III resins , where the color change was higher for resin G III ( p = 0.0000002 ) . The same was observed between G III and GV , where the resin enamel G III showed a statistically superior to the color change ( p = 0.0000005 ) Average . Resins to dentin was there a statistical equality between the materials studied . We conclude that the resins studied change in color and resin enamel G III was the most suffered major color changes after aging by thermocycling .

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A healthy and attractive smile is very valued in today s society. Yet this requires better aesthetic and cosmetic solutions from dental surgeons.The present paper presents a case report of diastema closure using an association of tooth movement induced by orthodontic elastics,dental cosmetics and resin-bonded prosthesis. The female patient L.B.A.J., aged 19 years, visited the Integrated Clinic of Araçatuba DentalSchool UNESP mainly complaining of missing teeth and poor esthetics. After anamnesis, clinical and radiographic examination revealedhypodontia of the maxillary right and left first premolars, abnormal maxillary right lateral incisor shape and diastema between the maxillaryright lateral incisor and canine and between the maxillary left lateral incisor and canine. Planning was done which included indication ofdiastema closure with composite resin restoration and metal-free resin-bonded prosthesis, with a structure made of Vectris (Ivoclar VivadentInc., Amherst, NT, USA). The option for dental cosmetics associated with resin-bonded prosthesis after movement with orthodontic elasticsresulted in an excellent aesthetic outcome of low cost and short treatment duration.Indexing terms: composite resins; diastema; fixed resin bonded partial denture.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the behavior of reinforced composites with polyamide 6 fibers aligned (6000 rpm) and alignment (120 rpm) with or without CNT using the flexural strength test. After preparation of nanofibers aligned nylon 6 (6000 rpm) and alignment (120 rpm) with and without incorporation of nanotube carbon by the method of electrospinning, were performed one control group (n = 10) and 4 experimental groups (n = 40) G1: Control (just resin Charisma - Heraeus Kulzer) ;G2 Resin + N6 aligned (6000 rpm) + CNT; G3:Resin + N6 alignment (120 rpm) + CNT; G4: Resin + aligned ( 6000 rpm) N6. G5: Resin + N6 alignment (120 rpm). The fibers were cut to the dimensions of 0,3 x 15 mm and were applied an adhesive at the surface (Single Bond 2) for 5 min and cured. In the matrix, was added resin in the proximal box (Charisma A2, Heraeus Kulzer) and cured for 40 s. (power 1100 mW / cm²). A first layer of resin and on the resin was deposited. The resin layers specimens were light irradiated with three overlapping exposures delivered. For each resin layer were light irradiated for 40 sec. The samples were tested with a cross-speed of 1 mm / min, and a 50 Kgf at Universal testing machine (EMIC mod.DL2000). The Dunnet test showed that only the nanotube group was significantly different from the control group. The ANOVA two-way indicates that the nanotube factor was statistically significant (p < 0.05) and there is no interaction between factors and orientation nanotube. The presence of nanotube showed lower fracture resistance values for aligned and unaligned groups. The results of this study showed that the orientation of the fibers does not influence the strength of composite resins and the incorporation of nylon nanofibers with carbon nanotubes decreased the fracture resistance values. The presence of the fibers has not been able to improve the strength of the material in any of the...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the behavior of reinforced composites with polyamide 6 fibers aligned (6000 rpm) and alignment (120 rpm) with or without CNT using the flexural strength test. After preparation of nanofibers aligned nylon 6 (6000 rpm) and alignment (120 rpm) with and without incorporation of nanotube carbon by the method of electrospinning, were performed one control group (n = 10) and 4 experimental groups (n = 40) G1: Control (just resin Charisma - Heraeus Kulzer) ;G2 Resin + N6 aligned (6000 rpm) + CNT; G3:Resin + N6 alignment (120 rpm) + CNT; G4: Resin + aligned ( 6000 rpm) N6. G5: Resin + N6 alignment (120 rpm). The fibers were cut to the dimensions of 0,3 x 15 mm and were applied an adhesive at the surface (Single Bond 2) for 5 min and cured. In the matrix, was added resin in the proximal box (Charisma A2, Heraeus Kulzer) and cured for 40 s. (power 1100 mW / cm²). A first layer of resin and on the resin was deposited. The resin layers specimens were light irradiated with three overlapping exposures delivered. For each resin layer were light irradiated for 40 sec. The samples were tested with a cross-speed of 1 mm / min, and a 50 Kgf at Universal testing machine (EMIC mod.DL2000). The Dunnet test showed that only the nanotube group was significantly different from the control group. The ANOVA two-way indicates that the nanotube factor was statistically significant (p < 0.05) and there is no interaction between factors and orientation nanotube. The presence of nanotube showed lower fracture resistance values for aligned and unaligned groups. The results of this study showed that the orientation of the fibers does not influence the strength of composite resins and the incorporation of nylon nanofibers with carbon nanotubes decreased the fracture resistance values. The presence of the fibers has not been able to improve the strength of the material in any of the...

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the effect of mouth rinse solutions Lion color stability, surface roughness and microhardness of two composite resins. Material and Methods: Fifty test specimens of each composite (Filtek Z250 and Z350; 3M ESPE) were made using a teflon matrix (12x2 mm). Color, surface roughness and Knoop microhardness baseline measurements of each specimen were made and specimens (n=10) were immersed in 5 mouth rinse solutions: G1: distilled water (control), G2: Plax Classic, G3: Plax alcohol-free; G4: Periogard, and G5: Listerine. Final measurements of color, roughness and microhardness were performed and the results submitted to statistical analysis (2-way ANOVA, Bonferroni's test; p<0.05). Results: The most significant color change was observed for Z250 when immersed in Listerine (p<0.05). Z350 showed greater color change when immersed in Plax alcohol-free (p<0.05), but with no significant difference for Listerine (p>0.05). With regard to roughness, both composites showed significant changes when immersed in Listerine in comparison with Plax alcohol-free (p<0.05). Microhardness of Z350 was shown to be significantly changed when the composite was immersed in Plax alcohol-free (p<0.05). Conclusion: Composite changes depended on the material itself rather than the mouth rinse solution used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diferentes fatores devem ser considerados nos casos de substituição de restaurações em dentes anteriores, tais como tratamento periodontal e tipo de material utilizado. Nessas situações, uma abordagem multidisciplinar é fundamental. Pacientes com resinas antigas próximas à margem gengivaI normalmente apresentam inflamação do tecido nessa região; por esse motivo, uma adequação prévia é fundamental para o sucesso do tratamento restaurador. Além disso, cuidados na substituição dessas restaurações devem ser considerados pelo profissional e pelo paciente. Os laminados cerâmicos têm sido amplamente utilizados em dentes anteriores; no entanto, esse tratamento deve ser indicado em situações específicas, de tal forma que seja o mais conservador possível. Assim, o presente trabalho demonstra, por meio de um caso clínico, a associação da Periodontia e Dentística na substituição de resinas compostas por laminados cerâmicos, de forma conservadora.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods: The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2) to be tested after 24 hours (24 h) and 6 months (6 m) of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results: Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26) nor time (p=0.62). No interaction between material × time was detected (p=0.28). Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53) and 30.06 (1.95), CF 34.26 (3.47) and 32.75 (4.18), ASEP 29.54 (4.14) and 33.47 (2.47), P90 30.27 (2.03) and 31.34 (2.19). Conclusions: The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage.