816 resultados para Composite Physical Function Scale
Resumo:
Visual counts of ice-rafted debris (IRD), foraminifera, and radiolaria were made for ~1500 samples in Site 1094 spanning the last four climatic cycles (marine isotope stages 1-11). Most, but not all, of the IRD variability is captured by whole-core physical properties including magnetic susceptibility and Q-ray attenuation bulk density. Glacial periods are marked by high IRD abundance and millennial-scale variability, which may reflect instability of ice shelves in the Weddell Sea region. Each interglacial period exhibits low IRD and high foraminiferal abundance during the early part of the interglacial, indicating relatively warm sea-surface temperatures and reduced influence of sea ice. IRD increases and foraminiferal abundances decrease during the latter part of each interglacial, indicating a return to more glacial-like conditions. Glacial terminations I and V are each characterized by a step-wise reduction in ice-rafting punctuated by a brief pulse in IRD delivery and reversal in delta18O. The coarse fraction of the sediment is dominated by ash and radiolaria, and the relative abundance of these components is remarkably similar to the concentration of Na+ in Vostok. Each of these variables is believed to be controlled mainly by sea-ice cover, thereby providing a means for sediment-ice core correlation.
Resumo:
Mode of access: Internet.
Resumo:
This paper investigates the input-output characteristics of structural health monitoring systems for composite plates based on permanently attached piezoelectric transmitter and sensor elements. Using dynamic piezoelectricity theory and a multiple integral transform method to describe the propagating and scattered flexural waves an electro-mechanical model for simulating the voltage input-output transfer function for circular piezoelectric transmitters and sensors adhesively attached to an orthotropic composite plate is developed. The method enables the characterization of all three physical processes, i.e. wave generation, wave propagation and wave reception. The influence of transducer, plate and attached electrical circuit characteristics on the voltage output behaviour of the system is examined through numerical calculations, both in frequency and the time domain. The results show that the input-output behaviour of the system is not properly predicted by the transducers' properties alone. Coupling effects between the transducers and the tested structure have to be taken into account, and adding backing materials to the piezoelectric elements can significantly improve the sensitivity of the system. It is shown that in order to achieve maximum sensitivity, particular piezoelectric transmitters and sensors need to be designed according to the structure to be monitored and the specific frequency regime of interest.
Resumo:
Morningness scales have been translated into several languages, but it lack of normative data and methodological differences make cross-cultural comparisons difficult. This study examines the psychometric properties and factor structure of the Composite Scale of Morningness (CSM) in samples from five countries: France (n = 627), Italy (n, = 702), Spain (n = 391), Thailand (n. = 503), and Australia (17 = 654). Strong national differences are identified. A quadratic relationship between age and CSM total score was apparent in the Australian data with a downward trend after age 35 yrs. There was no age effect in air), sample in the range from 18 to 29 yrs. Factor analysis identified a three-factor solution in all groups for both men and women. Tucker's congruence coefficients indicate that: (1) this solution is highly congruent between sexes in each culture, and (2) a morning affect factor is highly congruent between cultures. These results indicate there are national differences in factorial structure and that cut-off scores used to categorize participants as morning- and evening-types should be established for different cultural and age groups.
Resumo:
Objective: To establish concurrent validity, interrater and test-retest reliability of the Modified Elderly Mobility Scale (MEMS). Methods: Ninety elderly patients were scored on the MEMS. To establish concurrent validity, 75 patients MEMS scores were compared to Functional Independence Measure (FIM) scores using Spearman's correlation. Videotaped patient performances were used to establish interrater and test-retest reliability using percentage absolute agreement and intraclass correlation coefficients (ICCs). Results: The total MEMS score demonstrated a significant association with the motor (r = 0.725) and total FIM scores (r = 0.718). Absolute agreement for interrater reliability was greater than 93% for all test items, with 97 and 98% for the two new measures, respectively. Test-retest reliability demonstrated similar high levels of absolute agreement and had ICCs ranging from 0.870 to 1.0. Conclusions: The MEMS is a quick, valid and reliable test of motor function of elderly patients with a spread of functional levels.
Resumo:
The purpose of this paper was to evaluate the psychometric properties of a stage-specific selfefficacy scale for physical activity with classical test theory (CTT), confirmatory factor analysis (CFA) and item response modeling (IRM). Women who enrolled in the Women On The Move study completed a 20-item stage-specific self-efficacy scale developed for this study [n = 226, 51.1% African-American and 48.9% Hispanic women, mean age = 49.2 (67.0) years, mean body mass index = 29.7 (66.4)]. Three analyses were conducted: (i) a CTT item analysis, (ii) a CFA to validate the factor structure and (iii) an IRM analysis. The CTT item analysis and the CFA results showed that the scale had high internal consistency (ranging from 0.76 to 0.93) and a strong factor structure. Results also showed that the scale could be improved by modifying or eliminating some of the existing items without significantly altering the content of the scale. The IRM results also showed that the scale had few items that targeted high self-efficacy and the stage-specific assumption underlying the scale was rejected. In addition, the IRM analyses found that the five-point response format functioned more like a four-point response format. Overall, employing multiple methods to assess the psychometric properties of the stage-specific self-efficacy scale demonstrated the complimentary nature of these methods and it highlighted the strengths and weaknesses of this scale.
Resumo:
In this PhD study, the effects of the cation substitutions on the physical properties of pyroxenes have been discussed. The results of this work extend the knowledge on pyroxenes with different chemical compositions. These properties might be used in the development of ceramic pigments, advanced materials and for the mineralogical phase identification. First of all, the crystallographic differences between Ge and Si pyroxenes have been examined. The structure of C2/c Ca rich Ge clinopyroxenes is very close to the low pressure C2/c structural configuration found in Ca-rich Si-pyroxenes. The shear of the unit cell is very similar, and the difference between a Ge end member and the corresponding Si-rich one is less than 1°. Instead, a remarkable difference exists between Ca-poor Si and Ge clinopyroxenes. First, Ca-poor Ge pyroxenes do not display a P21/c symmetry, but retain the C2/c symmetry; second, the observed C2/c structure shows, at room pressure, the configuration with highly kinked tetrahedral chains characteristic of the high pressure C2/c symmetry of Si Ca-poor pyroxenes. In orthopyroxenes, with Pbca symmetry, Ge-pyroxenes have volume larger than Si-pyroxenes. Samples along the system CaCoGe2O6 - CoCoGe2O6 have been synthesized at three different temperatures: 1050 °C, 1200 °C and 1250 °C. The aim of these solid state syntheses was to obtain a solid solution at ambient pressure, since the analogues Si-system needs high pressure. Unfortunately, very limited solution occurs because the structure forms of the two end member (high temperature for CaCoGe2O6 and high pressure CoCoGe2O6) are incompatible. The phase diagram of this system has been sketched and compared to that of Si. The cobalt end member (CoCoGe2O6) is stable at ambient pressure in two symmetries: at 1050 °C C2/c and 1200 °C Pbca. The impurity phase formed during these experiments is cobalt spinel. Raman spectroscopy has been used to investigate the vibrational properties of Ca-pyroxenes CaCoGe2O6, CaMgGe2O6, CaMgSi2O6 and CaCoSi2O6. A comparison between silicate and germanate pyroxenes shows significant changes in peak positions of the corresponding modes caused mainly by the difference of the Ge-Si atomic weight along with the distortion and compression of the coordination polyhedra. Red shift in Raman spectra of germanates has been calculated by a rough scale factor calculated by a simple harmonic oscillator model, considering the different bond lengths for 4-coordinated Si ~ 1.60- 1.65 Å vs Ge–O distance ~1.70 - 1.80 Å. The Raman spectra of CaMgGe2O6 and CaCoGe2O6 have been classified, in analogy with silicate (Wang et al., 2001) counterparts, in different ranges: - R1 (880-640 cm-1): strong T-O stretching modes of Ge and non-bridging O1 and O2 atoms within the GeO4 tetrahedron; - R2 (640-480 cm-1): stretching/bending modes of Ge-Obr-Ge bonds (chain stretching and chain bending); - R4 (480-360 cm-1): O-Ge-O vibrations; - R3 (360-240 cm-1): motions of the cations in M2 and M1 sites correlated with tetrahedral chain motion and tilting tetrahedra; - R5 (below 240 cm-1): lattice modes. The largest shift with respect to CaMgSi2O6 - CaCoSi2O6 is shown by the T-O stretching and chain modes. High-pressure Raman spectroscopy (up to about 8 GPa) on the same samples of Ca-pyroxenes using an ETH-type diamond anvil cell shows no phase transition within the P-ranges investigated, as all the peak positions vary linearly as a function of pressure. Our data confirm previous experimental findings on Si-diopside (Chopelas and Serghiou, 2000). In the investigated samples, all the Raman peaks shift upon compression, but the major changes in wavenumber with pressure are attributed to the chain bending (Ge-Obr-Ge bonds) and tetrahedra stretching modes (Ge-Onbr). Upon compression, the kinking angle, the bond lengths and T-T distances between tetrahedra decrease and consequently the wavenumber of the bending chain mode and tetrahedra stretching mode increases. Ge-pyroxenes show the higher P-induced peak-position shifts, being more compressible than corresponding silicates. The vibrational properties of CaM2+Ge2O6 (M2+ =Mg, Mn, Fe, Co, Ni, Zn) are reported for the first time. The wavenumber of Ge-Obr-Ge bending modes decreases linearly with increasing ionic radius of the M1 cation. No simple correlation has been found with M1 atomic mass or size or crystallographic parameters for the peak at ~850 cm-1 and in the low wavenumber regions. The magnetic properties of the system CaCoSi2O6 - CoCoSi2O6 have been investigated by magnetometry. The join is always characterized by 1 a.p.f.u. of cobalt in M1 site and this causes a pure collinear antiferromagnetic behaviour of the intra-chain superexchange interaction involving Co ions detected in all the measurements, while the magnetic order developed by the cobalt ions in M2 site (intra-chain) is affected by weak ferromagnetism, due to the non-collinearity of their antiferromagnetic interaction. In magnetically ordered systems, this non-collinearity effect promotes a spin canting of anti-parallel aligned magnetic moments and thus is a source of weak ferromagnetic behaviour in an antiferromagnetic. The weak ferromagnetism can be observed only for the samples with Co content higher than 0.5 a.p.f.u. in M2, when the concentration is sufficiently high to create a long range order along the M2 chain which is magnetically independent of M1 chain. The ferromagnetism was detected both in the M(T) at 10 Oe and M(H).
Resumo:
Methods for understanding classical disordered spin systems with interactions conforming to some idealized graphical structure are well developed. The equilibrium properties of the Sherrington-Kirkpatrick model, which has a densely connected structure, have become well understood. Many features generalize to sparse Erdös- Rényi graph structures above the percolation threshold and to Bethe lattices when appropriate boundary conditions apply. In this paper, we consider spin states subject to a combination of sparse strong interactions with weak dense interactions, which we term a composite model. The equilibrium properties are examined through the replica method, with exact analysis of the high-temperature paramagnetic, spin-glass, and ferromagnetic phases by perturbative schemes. We present results of replica symmetric variational approximations, where perturbative approaches fail at lower temperature. Results demonstrate re-entrant behaviors from spin glass to ferromagnetic phases as temperature is lowered, including transitions from replica symmetry broken to replica symmetric phases. The nature of high-temperature transitions is found to be sensitive to the connectivity profile in the sparse subgraph, with regular connectivity a discontinuous transition from the paramagnetic to ferromagnetic phases is apparent.
Resumo:
The deposition and properties of electroless nickel composite coatings containing graphite, PTFE and chromium were investigated. Solutions were developed for the codeposition of graphite and chromium with electroless nickel. Solutions for the deposition of graphite contained heavy metal ions for stability, with non-ionic and anionic surfactants to provide wetting and dispersion of the particles. Stability for the codeposition of chromium particles was achieved by oxidation of the chromium. Thin oxide layers of 200 nm thick prevented initiation of the electroless reaction onto the chromium. A mechanism for the formation of electroless composite coatings was considered based on the physical adsorption of particles and as a function of the adsorption of charged surfactants and metal cations from solution. The influence of variables such as particle concentration in solution, particle size, temperature, pH, and agitation on the volume percentage of particles codeposited was studied. The volume percentage of graphite codeposited was found to increase with concentration in solution and playing rate. An increase in particle size and agitation reduced the volume percentage codeposited. The hardness of nickel-graphite deposits was found to decrease with graphite content in the as-deposited and heat treated condition. The frictional and wear properties of electroless nickel-graphite were studied and compared to those of electroless nickel-PTFE. The self-lubricating nature of both coatings was found to be dependent on the ratio of coated area to uncoated area, the size and content of lubricating material in the deposit, and the load between contacting surfaces. The mechanism of self-lubrication was considered, concluding that graphite only produced an initial lubricating surface due to the orientation of flakes, unlike PTFE, which produced true self-lubrication throughout the coating life. Heat treatment of electroless nickel chromium deposits at 850oC for 8 and 16 hours produced nickel-iron-chromium alloy deposits with a phosphorus rich surface of high hardness. Coefficients of friction and wear rates were intially moderate for the phosphorus rich layer but increased for the nickel-iron-chromium region of the coating.
Resumo:
Novel surface plasmonic optical fiber sensors have been fabricated using multiple coatings deposited on a lapped section of a single mode fiber. UV laser irradiation processing with a phase mask produces a nano-scaled surface relief grating structure resembling nano-wires. The resulting individual corrugations produced by material compaction are approximately 20 μm long with an average width at half maximum of 100 nm and generate localized surface plasmons. Experimental data are presented that show changes in the spectral characteristics after UV processing, coupled with an overall increase in the sensitivity of the devices to surrounding refractive index. Evidence is presented that there is an optimum UV dosage (48 joules) over which no significant additional optical change is observed. The devices are characterized with regards to change in refractive index, where significantly high spectral sensitivities in the aqueous index regime are found, ranging up to 4000 nm/RIU for wavelength and 800 dB/RIU for intensity. © 2013 Optical Society of America.
Resumo:
In the new health paradigm, the connotation of health has extended beyond the measures of morbidity and mortality to include wellness and quality of life. Comprehensive assessments of health go beyond traditional biological indicators to include measures of physical and mental health status, social role-functioning, and general health perceptions. To meet these challenges, tools for assessment and outcome evaluation are being designed to collect information about functioning and well-being from the individual's point of view.^ The purpose of this study was to profile the physical and mental health status of a sample of county government employees against U.S. population norms. A second purpose of the study was to determine if significant relationships existed between respondent characteristics and personal health practices, lifestyle and other health how the tools and methods used in this investigation can be used to guide program development and facilitate monitoring of health promotion initiatives.^ The SF-12 Health Survey (Ware, Kosinski, & Keller, 1995), a validated measure of health status, was administered to a convenience sample of 450 employees attending one of nine health fairs at an urban worksite. The instrument has been utilized nationally which enabled a comparative analysis of findings of this study with national results.^ Results from this study demonstrated that several respondent characteristics and personal health practices were associated with a greater percentage of physical and/or mental scale scores that were significantly "worse" or significantly "better" than the general population. Respondent characteristics that were significantly related to the SF-12 physical and/or mental health scale scores were gender, age, education, ethnicity, and income status. Personal health practices that were significantly related to SF-12 physical and/or mental scale scores were frequency of vigorous exercise, presence of chronic illness, being at one's prescribed height and weight, eating breakfast, smoking and drinking status. This study provides an illustration of the methods used to analyze and interpret SF-12 Health Survey data, using norm-based interpretation guidelines which are useful for purposes of program development and collecting information on health at the community level. ^