427 resultados para Coaxial electrospinning


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chitin and chitosan are nontoxic, biodegradable and biocompatible polymers produced by renewable natural sources with applications in diverse areas such as: agriculture, textile, pharmaceutical, cosmetics and biomaterials, such as gels, films and other polymeric membranes. Both have attracted greater interest of scientists and researchers as functional polymeric materials. In this context, the objective of this study was to take advantage of the waste of shrimp (Litopenaeus vannamei and Aristeus antennatus) and crabs (Ucides cordatus) from fairs, beach huts and restaurant in Natal/RN for the extraction of chitin and chitosan for the production of membranes by electrospinning process. The extraction was made through demineralization, deproteinization, deodorization and deacetylation. Morphological analyzes (SEM and XRD), Thermal analysis (TG and DTG), Spectroscopy in the Region of the Infrared with Transformed of Fourier (FTIR) analysis Calorimetry Differential Scanning (DSC) and mechanical tests for traction were performed. In (XRD) the semicrystalline structure of chitosan can be verified while the chitin had higher crystallinity. In the thermal analysis showed a dehydration process followed by decomposition, with similar behavior of carbonized material. Chitosan showed temperature of maximum degradation lower than chitin. In the analysis by Differential Scanning Calorimetry (DSC) the curves were coherent to the thermal events of the chitosan membranes. The results obtained with (DD) for chitosan extracted from Litopenaeus vannamei and Aristeus antennatus shrimp were (80.36 and 71.00%) and Ucides cordatus crabs was 74.65%. It can be observed that, with 70:30 solutions (v/v) (TFA/DCM), 60 and 90% CH3COOH, occurred better facilitate the formation of membranes, while 100:00 (v/v) (TFA/DCM) had formation of agglomerates. In relation to the monofilaments diameters of the chitosan membranes, it was noted that the capillary-collector distance of 10 cm and tensions of 25 and 30 kV contributed to the reduction of the diameters of membranes. It was found that the Young s modulus decreases with increasing concentration of chitosan in the membranes. 90% CH3COOH contributed to the increase in the deformation resulting in more flexible material. The membranes with 5% chitosan 70:30 (v/v) (TFA/DCM) had higher tensile strength

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The determination of the rheology of drilling fluids is of fundamental importance to select the best composition and the best treatment to be applied in these fluids. This work presents a study of the rheological behavior of some addictives used as viscosifiers in water-based drilling fluids. The evaluated addictives were: Carboxymethylcellulose (CMC), Xanthan gum (GX), and Bentonite. The main objective was to rheologically characterize suspensions composed by these addictives, by applying mathematical models for fluid flow behavior, in order to determine the best flow equation to represent the system, as well as the model parameters. The mathematical models applied in this research were: the Bingham Model, the Ostwald de Wale Model, and the Herschel-Bulkley Model. A previous study of hydration time for each used addictive was accomplished seeking to evaluate the effect of polymer and clay hydration on rheological behavior of the fluid. The rheological characterization was made through typical rheology experiments, using a coaxial cylinder viscosimeter, where the flow curves and the thixotropic magnitude of each fluid was obtained. For each used addictive the rheological behavior as a function of temperature was also evaluated as well as fluid stability as a function of the concentration and kind of addictive used. After analyses of results, mixtures of polymer and clay were made seeking to evaluate the rheological modifications provided by the polymer incorporation in the water + bentonite system. The obtained results showed that the Ostwald de Waale model provided the best fit for fluids prepared using CMC and for fluids with Xanthan gum and Bentonite the best fit was given by the Herschel-Bulkley one

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of confinement on the magnetic structure of vortices of dipolar coupled ferromagnetic nanoelements is an issue of current interest, not only for academic reasons, but also for the potential impact in a number of promising applications. Most applications, such as nano-oscillators for wireless data transmission, benefit from the possibility of tailoring the vortex core magnetic pattern. We report a theoretical study of vortex nucleation in pairs of coaxial iron and Permalloy cylinders, with diameters ranging from 21nm to 150nm, and 12nm and 21nm thicknesses, separated by a non-magnetic layer. 12nm thick iron and Permalloy isolated (single) cylinders do not hold a vortex, and 21nm isolated cylinders hold a vortex. Our results indicate that one may tailor the magnetic structure of the vortices, and the relative chirality, by selecting the thickness of the non-magnetic spacer and the values of the cylinders diameters and thicknesses. Also, the dipolar interaction may induce vortex formation in pairs of 12nm thick nanocylinders and inhibit the formation of vortices in pairs of 21nm thick nanocylinders. These new phases are formed according to the value of the distance between the cylinderes. Furthermore, we show that the preparation route may control relative chirality and polarity of the vortex pair. For instance: by saturating a pair of Fe 81nm diameter, 21nm thickness cylinders, along the crystalline anisotropy direction, a pair of 36nm core diameter vortices, with same chirality and polarity is prepared. By saturating along the perpendicular direction, one prepares a 30nm diameter core vortex pair, with opposite chirality and opposite polarity. We also present a theoretical discussion of the impact of vortices on the thermal hysteresis of a pair of interface biased elliptical iron nanoelements, separated by an ultrathin nonmagnetic insulating layer. We have found that iron nanoelements exchange coupled to a noncompensated NiO substrate, display thermal hysteresis at room temperature, well below the iron Curie temperature. The thermal hysteresis consists in different sequences of magnetic states in the heating and cooling branches of a thermal loop, and originates in the thermal reduction of the interface field, and on the rearrangements of the magnetic structure at high temperatures, 5 produce by the strong dipolar coupling. The width of the thermal hysteresis varies from 500 K to 100 K for lateral dimensions of 125 nm x 65 nm and 145 nm x 65 nm. We focus on the thermal effects on two particular states: the antiparallel state, which has, at low temperatures, the interface biased nanoelement with the magnetization aligned with the interface field and the second nanoelement aligned opposite to the interface field; and in the parallel state, which has both nanoelements with the magnetization aligned with the interface field at low temperatures. We show that the dipolar interaction leads to enhanced thermal stability of the antiparallel state, and reduces the thermal stability of the parallel state. These states are the key phases in the application of pairs of ferromagnetic nanoelements, separated by a thin insulating layer, for tunneling magnetic memory cells. We have found that for a pair of 125nm x 65nm nanoelements, separated by 1.1nm, and low temperature interface field strength of 5.88kOe, the low temperature state (T = 100K) consists of a pair of nearly parallel buckle-states. This low temperature phase is kept with minor changes up to T= 249 K when the magnetization is reduced to 50% of the low temperature value due to nucleation of a vortex centered around the middle of the free surface nanoelement. By further increasing the temperature, there is another small change in the magnetization due to vortex motion. Apart from minor changes in the vortex position, the high temperature vortex state remains stable, in the cooling branch, down to low temperatures. We note that wide loop thermal hysteresis may pose limits on the design of tunneling magnetic memory cells

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: So far the only endovascular option to treat patients with thoraco abdominal aortic aneurysms is the deployment of branched grafts. We describe a technique consisting of the deployment of standard off-the- shelf grafts to treat urgent cases.Material and Methods: The sandwich technique consists of the deployment of ViaBahn chimney grafts in combination with standard thoracic and abdominal aortic stent grafts. The chimney grafts are deployed using a transbrachial and transaxillary access. These coaxial grafts are placed inside the thoracic tube graft. After deployment of the infrarenal bifurcated abdominal graft a bridging stent-a short tube graft is positioned inside the thoracic graft further stabilizing the chimney grafts.Results: 5 patients with symptomatic thoraco abdominal aneurysms were treated. There was one Type I endoleak that resolved after 2 months. In all patients 3 stentgrafts had to be used When possible all visceral and renal branches were revascularized. A total number of 17 arteries were reconnected with covered branches. During follow up we lost one target vessel the right renal artery.Conclusion: The sandwich technique in combination with chimney grafts permits a total endovascular exclusion of thoraco abdominal aortic aneurysms. In all cases off-the shelf products and grafts could be used. The number of patients treated so far is still too small to draw further more robust conclusions with regard to long term performance and durability. (C) 2010 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The great interest observed in wireless communication systems has required the development of new configurations of microstrip antennas, because they are easily built and integrated to other microwave circuit components, which is suitable for the construction and development of planar antenna arrays and microwave integrated circuits. This work presents a new configuration of tapered microstrip antenna, which is obtained by impressing U-slots on the conducting patch combined with a transmission line matching circuit that uses an inset length. It is shown that the use of U-slots in the microstrip antenna conducting patch excites new resonating modes, that gives a multiband characteristic for the slotted microstrip antenna, that is suitable for applications in communication systems that operates several frequencies simultaneously. Up to this date, the works reported in the literature deals with the use of Uslotted microstrip rectangular antennas fed by a coaxial probe. The properties of a linear array of microstrip patch tapered antennas are also investigated. The main parameters of the U slotted tapered microstrip antennas are investigated for different sizes and locations of the slots impressed on the conducting patch. The analysis of the proposed antenna is performed by using the resonant cavity and equivalent transmission line methods, in combination with a parametric study, that is conducted by the use of the Ansoft Designer, a commercial computer aided microwave software well known by its accuracy and efficiency. The mentioned methods are used to evaluate the effect in the antennas parameters, like resonant frequency and return loss, produced by variations of the antenna structural parameters, accomplished separately or simultaneously. An experimental investigation is also developed, that consists of the design, construction and measurement of several U slotted microstrip antenna prototypes. Finally, theoretical and simulated results are presented that are in agreement with the measured ones. These results are related to the resonating modes identification and to the determination of the main characteristics of the investigated antennas, such as resonant frequency, return loss, and radiation pattern

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The freezing point depression (FPD) of orange juice at different concentrations was measured by using a simple apparatus. Results showed that the initial freezing point decreased approximately 90% with the increase of juice concentration between 46degrees and 66degrees Brix (water content respectively between 52.8 and 32.8% w/w). The thermal conductivity of orange juice as a function of fluid concentration was also investigated by using a coaxial dual-cylinder apparatus. Below the freezing point, the thermal conductivity was strongly affected by both the orange juice concentration and temperature. Simple equations in terms of water content and temperature could be adjusted to experimental data of FPD and thermal conductivity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laminar axial flow of a pseudoplastic fluid food (soursop, juice) in annular ducts has been experimentally investigated. In the first part of the manuscript, the rheological behavior of soursop juice, being essential for the annular flow analysis, was completely determined from 9.3 to 49.4 degrees Brix and temperatures from 0.4 degrees C to 68.8 degrees C, using a rotational rheometer equipped with coaxial cylinders. In order to test the adequacy of the rheology results, pressure loss data in the laminar pipe flow were collected and then experimental and theoretical friction factors were compared, showing excellent agreement, which indicated the reliability of the Power-Law model for describing the soursop juices. In the second part, pressure loss in annular regions was measured and used to estimate friction factors, which were then compared to those resulted from analytical and semi-analytical equations. The principal contributions of this article are to provide a review on the determination of friction factors-Reynolds number of pseudoplastic fluids in annuli, and also supply extensive new experimental data on the rheological properties and pressure loss of an important shear-thinning fluid food, which is of particular interest for the food engineering process design. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pressure field in a high-power klystron amplifier is investigated to scale the ionic vacuum pump used to maintain the ultra high-vacuum in the device in order to increase its life-time. The investigation is conducted using an 1.3 GHz, 100 A - 240 keV high-power klystron with five reentrant coaxial cavities, assembled in a cylindrical drift tube 1.2 m long. The diffusion equation is solved to the regime molecular flow to obtain the pressure profile along the axis of the klystron drift tube. The model, solved by both analytical and numerical procedures, is able to determine the pressure values in steady-state case. This work considers the specific conductance and all important gas sources, as in the degassing of the drift tube and cavities walls, cathode, and collector. For the drift tube degassing rate equals to q(deg) = 2x10(-12) (-)mbar.L.s(-1) cm(-2) (degassing rate per unit area), to cavities q(cavity) = 3x10(-13) mbar.L.s(-1)cm(-2), to the cathode q(cathode) = 6x10(-9)_mbar.L.s(-1) and to the collector q(collector) = 6x10(-9) mbar.L.s(-1), it was found that a 10 L.s(-1) ionic vacuum pump connected in the output waveguide wall is suitable. In this case, the pressure obtained in the cathode is p(cathode) = 6.3x10(-9) mbar, in the collector p(collector) = 2.7x10(-9) mbar, and in the output waveguide p = 2.1x10(-9) mbar. Although only the steady-state case is analyzed, some aspects that may be relevant in a transient situation, for instance, when the beam hits the drift tube walls, producing a gas burst, is also commented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In 21 normal adult male subjects, the muscular activity of the levator scapulae and rhomboideus major muscles was studied electromyographically during the movements of the shoulder and arm. Two single coaxial needle electrodes were used for registering the action potentials. Concerning shoulder movement, it was shown that the levator scapulae was active in elevation and rhomboideus major was active in retraction. Both muscles were inactive during protrusion, in most events. Concerning free movements of the arm, both muscles were active in abduction, elevation, adduction, flexion and circumduction, but inactive in extension. During the same movements, performed with a load, we observed greater intensity in the activity of these muscles in comparison to their activity during free movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An electromyographic study of the musculus interosseus dorsalis was performed on the right hand of 25 young adult male right-handed volunteers. The electrodes, simple coaxial needles, were implanted one at the ulnar head and the other at the radial head of the muscle. The muscles were analyzed during free movements of the index and against resistance. The same movements were done in four different positions of the fore-arm and hand, without variation in the results for each one of the movements. There was no significant difference between the activities of the ulnar head and radial head. During freely performed movements, muscle activity was recorded only during abduction. During movements against resistance, muscle activity was completely nil only during adduction; during the remaining movements, however, moderate (2+), strong (3+) and very strong activity (4+) was recorded.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The participation of the levator scapulae and rhomboideus major muscles in some movements of the upper limb was analysed in 21 young adult male volunteers. A 2 channel TECA TE4 electromyograph connected with single coaxial needle electrodes was used. In abduction, elevation, adduction, flexion and circumduction participation of both muscles in free movements of the upper limb was found. In extension, however, these muscles were inactive. In the same movements analysed with load, a major intensity of action of these muscles was registered as compared with those obtained in free movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The participation of the trapezius (middle portion) and rhomboideus major muscles submitted to an isometric tension (holding downward dumbells of 11, 15 and 19 kg) was analysed in 40 young adult male vounteers. A 2 channel TECA TE4 electromyograph connected with single coaxial needle electrodes was used. In the initial phase of the test, holding downward, generally the trapezius and rhomboideus major muscles showed activity and no activity, respectively. In the cases where activity was present during the downward positions it was reduced gradually until complete rest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The trapezius (pars superior) and levator scapulae mm were studied in the arm movements of circumduction and pendular oscillation in 30 adult volunteers of both sexes. A two-channel TECA TE 4 electromyograph and single coaxial needle electrodes were used. It was found out that as arm conduction, both muscles show an activity that gradually increases and decreases the intensity at the elevation and lowering phases respectively. It was also noticed that between two consecutive circumductions a 'silent period' in the activity of the above mentioned muscles occurs. In pendular oscillation these muscles show electrical activity both in the forward and backward moving, and both muscles show a 'silent period' when the arm passes by the trunk. It was not observed in these movements any significant difference in activity of these muscles regarding sex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electromyographic study of the trapezius (pars superior) and levator scapulae mm. in the head movements was carried out in 30 young, adult male volunteers of both sexes and with no antecedent muscular or articular problems. The analysis was carried out with a two-channel TECA TE4 electromyograph and with single coaxial needle electrodes. Inactivity of the trapezius (pars superior) and levator scapulae mm. was noticed in all cases, in flexion and extension movements, whereas in homolateral and heterolateral rotation movements, these muscles showed to be inactive in most cases.