987 resultados para CURRENT TRANSIENT SPECTROSCOPY


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The degradation behaviour of SnO(2)-based varistors (SCNCr) due to current pulses (8/20 mu s) is reported here for the first time in comparison with the ZnO-based commercial varistors (ZnO). Puncturing and/or cracking failures were observed in ZnO-based varistors possessing inferior thermo-mechanical properties in comparison with that found in a SCNCr system free of failures. Both systems presented electric degradation related to the increase in the leakage current and decrease in the electric breakdown field, non-linear coefficient and average value of the potential barrier height. However, it was found that a more severe degradation occurred in the ZnO-based varistors concerning their non-ohmic behaviour, while in the SCNCr system, a strong non-ohmic behaviour remained after the degradation. These results indicate that the degradation in the metal oxide varistors is controlled by a defect diffusion process whose rate depends on the mobility, the concentration of meta-stable defects and the amount of electrically active interfaces. The improved behaviour of the SCNCr system is then inferred to be associated with the higher amount of electrically active interfaces (85%) and to a higher energy necessary to activate the diffusion of the specific defects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Light-emitting electrochemical cells (LECs) made of electroluminescent polymers were studied by d.c. and transient current-voltage and luminance-voltage measurements to elucidate the operation mechanisms of this kind of device. The time and external voltage necessary to form electrical double layers (EDLs) at the electrode interfaces could be determined from the results. In the low-and intermediate-voltage ranges (below 1.1 V), the ionic transport and the electronic diffusion dominate the current, being the device operation better described by an electrodynamic model. For higher voltages, electrochemical doping occurs, giving rise to the formation of a p-i-n junction, according to an electrochemical doping model. Copyright (C) EPLA, 2012

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The circulation at the Eastern Brazilian Shelf (EBS), near 13 degrees S, is discussed in terms of the currents and hydrography, associating large-scale circulation, transient and local processes to establish a regional picture of the EBS circulation. The results show that the circulation within the continental shelf and slope region is strongly affected by the seasonal changes in the wind field and mesa/large-scale circulation. Transient processes associated to the passage of Cold Front systems or meso-scale activity and the presence of a local canyon add more complexity to the system. During the austral spring and summer seasons, the prevailing upwelling favorable winds blowing from E-NE were responsible for driving southwestward shelf currents. The interaction with the Western Boundary Current (the Brazil Current), especially during summer, was significant and a considerable vertical shear in the velocity field was observed at the outer shelf. The passage of a Cold Front system during the springtime caused a complete reversal of the mean flow and contributed to the deepening of the Mixed Layer Depth (MLD). In addition, the presence of Salvador Canyon, subject to an upwelling favorable boundary current, enhanced the upwelling system, when compared to the upwelling observed at the adjacent shelf. During the austral autumn and winter seasons the prevailing downwelling favorable winds blowing from the SE acted to total reverse the shelf circulation, resulting in a northeastward flow. The passage of a strong Cold Front, during the autumn season, contributed not only to the strengthening of the flow but also to the deepening of the MLD. The presence of the Salvador Canyon, when subject to a downwelling favorable boundary current, caused an intensification of the downwelling process. Interestingly, the alongshore velocity at the shelf region adjacent to the head of the canyon was less affected when compared to the upwelling situation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis methods of EPR spectroscopy were used to investigate polyion-counterion interactions in polyelectrolyte solutions. The fact that EPR techniques are local methods is exploited and by employing spin-carrying (i.e., EPR-active) probe ions it is possible to examine polyelectrolytes from the counterions’ point of view. It was possible to gain insight into i) the dynamics and local geometry of counterion attachment, ii) conformations and dynamics of local segments of the polyion in an indirect manner, and iii) the spatial distribution of spin probe ions that surround polyions in solution. Analysis of CW EPR spectra of dianion nitroxide spin probe Fremy’s salt (FS, potassium nitrosodisulfonate) in solutions of cationic PDADMAC polyelectrolyte revealed that FS ions and PDADMAC form transient ion pairs with a lifetime of less than 1 ns. This effect was termed as dynamic electrostatic attachment (DEA). By spectral simulation taking into account the rotational dynamics as a uniaxial Brownian reorientation, also the geometry of the attached state could be characterized. By variation of solvent, the effect of solvent viscosity and permittivity were investigated and indirect information of the polyelectrolyte chain motion was obtained. Furthermore, analysis of CW EPR data also indicates that in mixtures of organic solvent/water PDADMAC chains are preferentially solvated by the organic solvent molecules, while in purely aqueous mixtures the PDADMAC chain segments were found in different conformations depending on the concentration ratio R of FS counterions to PDADMAC repeat units.Broadenings in CW EPR spectra of FS ions were assigned to spin-exchange interaction and hence contain information on the local concentrations and distributions of the counterions. From analysis of these broadenings in terms of a modified cylindrical cell approach of polyelectrolyte theory, radial distribution functions for the FS ions in the different solvents were obtained. This approach breaks down in water above a threshold value of R, which again indicates that PDADMAC chain conformations are altered as a function of R. Double electron-electron resonance (DEER) measurements of FS ions were carried out to probe the distribution of attached counterions along polyelectrolyte chains. For a significant fraction of FS spin probes in solution with a rigid-rod model polyelectrolyte containing charged Ru2+-centers, a bimodal distance distribution was found that nicely reproduced the spacings of direct and next-neighbor Ru2+-centers along the polyelectrolyte: 2.35 and 4.7 nm. For the system of FS/PDADMAC, DEER data could be simulated by assuming a two-state distribution of spin probes, one state corresponding to a homogeneous (3-dimensional) distribution of spin probes in the polyelectrolyte bulk and the other to a linear (1-dimensional) distribution of spin probes that are electrostatically condensed along locally extended PDADMAC chain segments. From this analysis it is suggested that the PDADMAC chains form locally elongated structures of a size of at least ~5 nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The weathering of Fe-bearing minerals under extraterrestrial conditions was investigated by Mössbauer (MB) spectroscopy to gain insights into the role of water on the planet Mars. The NASA Mars Exploration Rovers Spirit and Opportunity each carry a miniaturized Mössbauer spectrometer MIMOS II for the in situ investigation of Martian soils and rocks as part of their payload. The MER flight instruments had to be modified in order to work over the Martian diurnal temperature range (180 K – 290 K) and within the unique electronic environment of the rovers. The modification required special calibration procedures. The integration time necessary to obtain a good quality Mössbauer spectrum with the MIMOS II flight instruments was reduced by 30 % through the design of a new collimator. The in situ investigation of rocks along the rover Spirit's traverse in Gusev crater revealed weakly altered olivine basalt on the plains and pervasively altered basalt in the Columbia Hills. Correlation plots of primary Fe-bearing minerals identified by MB spectroscopy such as olivine versus secondary Fe-bearing phases such as nanophase Fe oxides showed that olivine is the mineral which is primarily involved in weathering reactions. This argues for a reduced availability of water. Identification of the Fe-oxyhydroxide goethite in the Columbia Hills is unequivocal evidence for aqueous weathering processes in the Columbia Hills. Experiments in which mineral powders were exposed to components of the Martian atmosphere showed that interaction with the atmosphere alone, in the absence of liquid water, is sufficient to oxidize Martian surface materials. The fine-grained dust suspended in the Martian atmosphere may have been altered solely by gas-solid reactions. Fresh and altered specimens of Martian meteorites were investigated with MIMOS II. The study of Martian meteorites in the lab helped to identify in Bounce Rock the first rock on Mars which is similar in composition to basaltic shergottites, a subgroup of the Martian meteorites. The field of astrobiology includes the study of the origin, evolution and distribution of life in the universe. Water is a prerequisite for life. The MER Mössbauer spectrometers identified aqueous minerals such as jarosite and goethite. The identification of jarosite was crucial to evaluate the habitability of Opportunity's landing site at Meridiani Planum during the formation of the sedimentary outcrop rocks, because jarosite puts strong constrains on pH levels. The identification of olivine in rocks and soils on the Gusev crater plains provide evidence for the sparsity of water under current conditions on Mars. Ratios of Fe2+/Fe3+ were obtained with Mössbauer spectroscopy from basaltic glass samples which were exposed at a deep sea hydrothermal vent. The ratios were used as a measure of potential energy for use by a microbial community. Samples from Mars analogue field sites on Earth exhibiting morphological biosignatures were also investigated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The improvement of devices provided by Nanotechnology has put forward new classes of sensors, called bio-nanosensors, which are very promising for the detection of biochemical molecules in a large variety of applications. Their use in lab-on-a-chip could gives rise to new opportunities in many fields, from health-care and bio-warfare to environmental and high-throughput screening for pharmaceutical industry. Bio-nanosensors have great advantages in terms of cost, performance, and parallelization. Indeed, they require very low quantities of reagents and improve the overall signal-to-noise-ratio due to increase of binding signal variations vs. area and reduction of stray capacitances. Additionally, they give rise to new challenges, such as the need to design high-performance low-noise integrated electronic interfaces. This thesis is related to the design of high-performance advanced CMOS interfaces for electrochemical bio-nanosensors. The main focus of the thesis is: 1) critical analysis of noise in sensing interfaces, 2) devising new techniques for noise reduction in discrete-time approaches, 3) developing new architectures for low-noise, low-power sensing interfaces. The manuscript reports a multi-project activity focusing on low-noise design and presents two developed integrated circuits (ICs) as examples of advanced CMOS interfaces for bio-nanosensors. The first project concerns low-noise current-sensing interface for DC and transient measurements of electrophysiological signals. The focus of this research activity is on the noise optimization of the electronic interface. A new noise reduction technique has been developed so as to realize an integrated CMOS interfaces with performance comparable with state-of-the-art instrumentations. The second project intends to realize a stand-alone, high-accuracy electrochemical impedance spectroscopy interface. The system is tailored for conductivity-temperature-depth sensors in environmental applications, as well as for bio-nanosensors. It is based on a band-pass delta-sigma technique and combines low-noise performance with low-power requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heusler intermetallics Mn$_{2}Y$Ga and $X_{2}$MnGa ($X,Y$=Fe, Co, Ni) undergo tetragonal magnetostructural transitions that can result in half metallicity, magnetic shape memory, or the magnetocaloric effect. Understanding the magnetism and magnetic behavior in functional materials is often the most direct route to being able to optimize current materials and design future ones.rnrnSynchrotron soft x-ray magnetic spectromicroscopy techniques are well suited to explore the the competing effects from the magnetization and the lattice parameters in these materials as they provide detailed element-, valence-, and site-specific information on the coupling of crystallographic ordering and electronic structure as well as external parameters like temperature and pressure on the bonding and exchange.rnrnFundamental work preparing the model systems of spintronic, multiferroic, and energy-related compositions is presented for context. The methodology of synchrotron spectroscopy is presented and applied to not only magnetic characterization but also of developing a systematic screening method for future examples of materials exhibiting any of the above effects. rnrnChapters include an introduction to the concepts and materials under consideration (Chapter 1); an overview of sample preparation techniques and results, and the kinds of characterization methods employed (Chapter 2); spectro- and microscopic explorations of $X_2$MnGa/Ge (Chapter 3); spectroscopic investigations of the composition series Mn$_{2}Y$Ga to the logical Mn$_3$Ga endpoint (Chapter 4); and a summary and overview of upcoming work (Chapter 5). Appendices include the results of a “Think Tank” for the Graduate School of Excellence MAINZ (Appendix A) and details of an imaging project now in progress on magnetic reversal and domain wall observation in the classical Heusler material Co$_2$FeSi (Appendix B).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the most diffused electronic device is the field effect transistor (FET), contained in number of billions in each electronic device. Organic optoelectronics is an emerging field that exploits the unique properties of conjugated organic materials to develop new applications that require a combination of performance, low cost and processability. Organic single crystals are the material with best performances and purity among the variety of different form of organic semiconductors. This thesis is focused on electrical and optical characterization of Rubrene single crystal bulk and thin films. Rubrene bulk is well known but for the first time we studied thin films. The first Current-voltage characterization has been performed for the first time on three Rubrene thin films with three different thickness to extract the charge carriers mobility and to assess its crystalline structure. As results we see that mobility increase with thickness. Field effect transistor based on Rubrene thin films on $SiO_2$ have been characterize by current-voltage (I-V) analyses (at several temperatures) and reveals a hopping conduction. Hopping behavior probably is due to the lattice mismatch with the substrate or intrinsic defectivity of the thin films. To understand effects of contact resistance we tested thin films with the Transmission Line Method (TLM) method. The TLM method revealeds that contact resistance is negligible but evidenced a Schottky behavior in a limited but well determined range of T. To avoid this effect we carried out annealing treatment after the electrode evaporation iswe performed a compete I-V characterization as a function of in temperature to extract the electronic density of states (DOS) distribution through the Space Charge Limited Current (SCLC) method. The results show a DOS with an exponential trenddistribution, as expected. The measured mobility of thin films is about 0.1cm^2/Vs and it increases with the film thickness. Further studies are necessary to investigate the reason and improve performances. From photocurrent spectrum we calculated an Eg of about 2.2eV and both thin films and bulk have a good crystal order. Further measurement are necessary to solve some open problems

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The adsorption of particles and surfactants at water-oil interfaces has attracted continuous attention because of its emulsion stabilizing effect and the possibility to form two-dimensional materials. Herein, I studied the interfacial diffusion of single molecules and nanoparticles at water-oil interfaces using fluorescence correlation spectroscopy. rnrnFluorescence correlation spectroscopy (FCS) is a promising technique to study diffusion of fluorescent tracers in diverse conditions. This technique monitors and analyzes the fluorescence fluctuation caused by single fluorescent tracers coming in and out of a diffraction-limited observation volume “one at a time”. Thus, this technique allows a combination of high precision, high spatial resolution and low tracer concentration. rnrnIn chapter 1, I discussed some controversial questions regarding the properties of water-hydrophobic interfaces and also introduced the current progress on the stability and dynamic of single nanoparticles at water-oil interfaces. The materials and setups I used in this thesis were summarized in chapter 2. rnrnIn chapter 3, I presented a new strategy to study the properties of water-oil interfaces. The two-dimensional diffusion of isolated molecular tracers at water/n-alkane interfaces was measured using fluorescence correlation spectroscopy. The diffusion coefficients of larger tracers with a hydrodynamic radius of 4.0 nm agreed well with the values calculated from the macroscopic viscosities of the two bulk phases. However, for small molecule tracers with hydrodynamic radii of only 1.0 and 0.6 nm, notable deviations were observed, indicating the existence of an interfacial region with a reduced effective viscosity. rnrnIn chapter 4, the interfacial diffusion of nanoparticles at water-oil interfaces was investigated using FCS. In stark contrast to the interfacial diffusion of molecular tracers, that of nanoparticles at any conditions is slower than the values calculated in accordance to the surrounding viscosity. The diffusion of nanoparticles at water-oil interfaces depended on the interfacial tension of liquid-liquid interfaces, the surface properties of nanoparticles, the particle sizes and the viscosities of surrounding liquid phases. In addition, the interfacial diffusion of nanoparticles with Janus motif is even slower than that of their symmetric counterparts. Based on the experimental results I obtained, I drew some possibilities to describe the origin of nanoparticle slowdown at water-oil interfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diese Arbeit widmet sich der Untersuchung der photophysikalischen Prozesse, die in Mischungen von Elektronendonoren mit Elektronenakzeptoren zur Anwendung in organischen Solarzellen auftreten. Als Elektronendonoren werden das Copolymer PBDTTT-C, das aus Benzodithiophen- und Thienothiophene-Einheiten besteht, und das kleine Molekül p-DTS(FBTTh2)2, welches Silizium-überbrücktes Dithiophen, sowie fluoriertes Benzothiadiazol und Dithiophen beinhaltet, verwendet. Als Elektronenakzeptor finden ein planares 3,4:9,10-Perylentetracarbonsäurediimid-(PDI)-Derivat und verschiedene Fullerenderivate Anwendung. PDI-Derivate gelten als vielversprechende Alternativen zu Fullerenen aufgrund der durch chemische Synthese abstimmbaren strukturellen, optischen und elektronischen Eigenschaften. Das gewichtigste Argument für PDI-Derivate ist deren Absorption im sichtbaren Bereich des Sonnenspektrums was den Photostrom verbessern kann. Fulleren-basierte Mischungen übertreffen jedoch für gewöhnlich die Effizienz von Donor-PDI-Mischungen.rnUm den Nachteil der PDI-basierten Mischungen im Vergleich zu den entsprechenden Fulleren-basierten Mischungen zu identifizieren, werden die verschiedenen Donor-Akzeptor-Kombinationen auf ihre optischen, elektronischen und strukturellen Eigenschaften untersucht. Zeitaufgelöste Spektroskopie, vor allem transiente Absorptionsspektroskopie (TA), wird zur Analyse der Ladungsgeneration angewendet und der Vergleich der Donor-PDI Mischfilme mit den Donor-Fulleren Mischfilmen zeigt, dass die Bildung von Ladungstransferzuständen einen der Hauptverlustkanäle darstellt.rnWeiterhin werden Mischungen aus PBDTTT-C und [6,6]-Phenyl-C61-buttersäuremethylesther (PC61BM) mittels TA-Spektroskopie auf einer Zeitskala von ps bis µs untersucht und es kann gezeigt werden, dass der Triplettzustand des Polymers über die nicht-geminale Rekombination freier Ladungen auf einer sub-ns Zeitskala bevölkert wird. Hochentwickelte Methoden zur Datenanalyse, wie multivariate curve resolution (MCR), werden angewendet um überlagernde Datensignale zu trennen. Zusätzlich kann die Regeneration von Ladungsträgern durch Triplett-Triplett-Annihilation auf einer ns-µs Zeitskala gezeigt werden. Darüber hinaus wird der Einfluss des Lösungsmitteladditivs 1,8-Diiodooctan (DIO) auf die Leistungsfähigkeit von p-DTS(FBTTh2)2:PDI Solarzellen untersucht. Die Erkenntnisse von morphologischen und photophysikalischen Experimenten werden kombiniert, um die strukturellen Eigenschaften und die Photophysik mit den relevanten Kenngrößen des Bauteils in Verbindung zu setzen. Zeitaufgelöste Photolumineszenzmessungen (time-resolved photoluminescence, TRPL) zeigen, dass der Einsatz von DIO zu einer geringeren Reduzierung der Photolumineszenz führt, was auf eine größere Phasentrennung zurückgeführt werden kann. Außerdem kann mittels TA Spektroskopie gezeigt werden, dass die Verwendung von DIO zu einer verbesserten Kristallinität der aktiven Schicht führt und die Generation freier Ladungen fördert. Zur genauen Analyse des Signalzerfalls wird ein Modell angewendet, das den gleichzeitigen Zerfall gebundener CT-Zustände und freier Ladungen berücksichtigt und optimierte Donor-Akzeptor-Mischungen zeigen einen größeren Anteil an nicht-geminaler Rekombination freier Ladungsträger.rnIn einer weiteren Fallstudie wird der Einfluss des Fullerenderivats, namentlich IC60BA und PC71BM, auf die Leistungsfähigkeit und Photophysik der Solarzellen untersucht. Eine Kombination aus einer Untersuchung der Struktur des Dünnfilms sowie zeitaufgelöster Spektroskopie ergibt, dass Mischungen, die ICBA als Elektronenakzeptor verwenden, eine schlechtere Trennung von Ladungstransferzuständen zeigen und unter einer stärkeren geminalen Rekombination im Vergleich zu PCBM-basierten Mischungen leiden. Dies kann auf die kleinere Triebkraft zur Ladungstrennung sowie auf die höhere Unordnung der ICBA-basierten Mischungen, die die Ladungstrennung hemmen, zurückgeführt werden. Außerdem wird der Einfluss reiner Fullerendomänen auf die Funktionsfähigkeit organischer Solarzellen, die aus Mischungen des Thienothienophen-basierenden Polymers pBTTT-C14 und PC61BM bestehen, untersucht. Aus diesem Grund wird die Photophysik von Filmen mit einem Donor-Akzeptor-Mischungsverhältnis von 1:1 sowie 1:4 verglichen. Während 1:1-Mischungen lediglich eine co-kristalline Phase, in der Fullerene zwischen den Seitenketten von pBTTT interkalieren, zeigen, resultiert der Überschuss an Fulleren in den 1:4-Proben in der Ausbildung reiner Fullerendomänen zusätzlich zu der co kristallinen Phase. Transiente Absorptionsspektroskopie verdeutlicht, dass Ladungstransferzustände in 1:1-Mischungen hauptsächlich über geminale Rekombination zerfallen, während in 1:4 Mischungen ein beträchtlicher Anteil an Ladungen ihre wechselseitige Coulombanziehung überwinden und freie Ladungsträger bilden kann, die schließlich nicht-geminal rekombinieren.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is the first part of a study investigating a model-based transient calibration process for diesel engines. The motivation is to populate hundreds of parameters (which can be calibrated) in a methodical and optimum manner by using model-based optimization in conjunction with the manual process so that, relative to the manual process used by itself, a significant improvement in transient emissions and fuel consumption and a sizable reduction in calibration time and test cell requirements is achieved. Empirical transient modelling and optimization has been addressed in the second part of this work, while the required data for model training and generalization are the focus of the current work. Transient and steady-state data from a turbocharged multicylinder diesel engine have been examined from a model training perspective. A single-cylinder engine with external air-handling has been used to expand the steady-state data to encompass transient parameter space. Based on comparative model performance and differences in the non-parametric space, primarily driven by a high engine difference between exhaust and intake manifold pressures (ΔP) during transients, it has been recommended that transient emission models should be trained with transient training data. It has been shown that electronic control module (ECM) estimates of transient charge flow and the exhaust gas recirculation (EGR) fraction cannot be accurate at the high engine ΔP frequently encountered during transient operation, and that such estimates do not account for cylinder-to-cylinder variation. The effects of high engine ΔP must therefore be incorporated empirically by using transient data generated from a spectrum of transient calibrations. Specific recommendations on how to choose such calibrations, how many data to acquire, and how to specify transient segments for data acquisition have been made. Methods to process transient data to account for transport delays and sensor lags have been developed. The processed data have then been visualized using statistical means to understand transient emission formation. Two modes of transient opacity formation have been observed and described. The first mode is driven by high engine ΔP and low fresh air flowrates, while the second mode is driven by high engine ΔP and high EGR flowrates. The EGR fraction is inaccurately estimated at both modes, while EGR distribution has been shown to be present but unaccounted for by the ECM. The two modes and associated phenomena are essential to understanding why transient emission models are calibration dependent and furthermore how to choose training data that will result in good model generalization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is the second part of a study investigating a model-based transient calibration process for diesel engines. The first part addressed the data requirements and data processing required for empirical transient emission and torque models. The current work focuses on modelling and optimization. The unexpected result of this investigation is that when trained on transient data, simple regression models perform better than more powerful methods such as neural networks or localized regression. This result has been attributed to extrapolation over data that have estimated rather than measured transient air-handling parameters. The challenges of detecting and preventing extrapolation using statistical methods that work well with steady-state data have been explained. The concept of constraining the distribution of statistical leverage relative to the distribution of the starting solution to prevent extrapolation during the optimization process has been proposed and demonstrated. Separate from the issue of extrapolation is preventing the search from being quasi-static. Second-order linear dynamic constraint models have been proposed to prevent the search from returning solutions that are feasible if each point were run at steady state, but which are unrealistic in a transient sense. Dynamic constraint models translate commanded parameters to actually achieved parameters that then feed into the transient emission and torque models. Combined model inaccuracies have been used to adjust the optimized solutions. To frame the optimization problem within reasonable dimensionality, the coefficients of commanded surfaces that approximate engine tables are adjusted during search iterations, each of which involves simulating the entire transient cycle. The resulting strategy, different from the corresponding manual calibration strategy and resulting in lower emissions and efficiency, is intended to improve rather than replace the manual calibration process.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the recent years chirped-pulse, Fourier-transform microwave (CP-FTMW) spectrometers have chan- ged the scope of rotational spectroscopy. The broad frequency and large dynamic range make possible structural determinations in molecular systems of increasingly larger size from measurements of heavy atom (13C, 15N, 18O) isotopes recorded in natural abundance in the same spectrum as that of the parent isotopic species. The design of a broadband spectrometer operating in the 2–8 GHz frequency range with further improvements in sensitivity is presented. The current CP-FTMW spectrometer performance is benchmarked in the analyses of the rotational spectrum of the water heptamer, (H2O)7, in both 2– 8 GHz and 6–18 GHz frequency ranges. Two isomers of the water heptamer have been observed in a pulsed supersonic molecular expansion. High level ab initio structural searches were performed to pro- vide plausible low-energy candidates which were directly compared with accurate structures provided from broadband rotational spectra. The full substitution structure of the most stable species has been obtained through the analysis of all possible singly-substituted isotopologues (H218O and HDO), and a least-squares rm(1) geometry of the oxygen framework determined from 16 different isotopic species compares with the calculated O–O equilibrium distances at the 0.01 Å level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the recent years chirped-pulse, Fourier-transform microwave (CP-FTMW) spectrometers have changed the scope of rotational spectroscopy. The broad frequency and large dynamic range make possible structural determinations in molecular systems of increasingly larger size from measurements of heavy atom (C-13, N-15, O-18) isotopes recorded in natural abundance in the same spectrum as that of the parent isotopic species. The design of a broadband spectrometer operating in the 2-8 GHz frequency range with further improvements in sensitivity is presented. The current CP-FTMW spectrometer performance is benchmarked in the analyses of the rotational spectrum of the water heptamer, (H2O)(7), in both 2-8 GHz and 6-18 GHz frequency ranges. Two isomers of the water heptamer have been observed in a pulsed supersonic molecular expansion. High level ab initio structural searches were performed to provide plausible low-energy candidates which were directly compared with accurate structures provided from broadband rotational spectra. The full substitution structure of the most stable species has been obtained through the analysis of all possible singly-substituted isotopologues ((H2O)-O-18 and HDO), and a least-squares r(m)((1)) geometry of the oxygen framework determined from 16 different isotopic species compares with the calculated O-O equilibrium distances at the 0.01 angstrom level. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Homeopathic preparations are used in homeopathy and anthroposophic medicine. Although there is evidence of effectiveness in several clinical studies, including double-blinded randomized controlled trials, their nature and mode of action could not be explained with current scientific approaches yet. Several physical methods have already been applied to investigate homeopathic preparations but it is yet unclear which methods are best suited to identify characteristic physicochemical properties of homeopathic preparations. The aim of this study was to investigate homeopathic preparations with UV-spectroscopy. In a blinded, randomized, controlled experiment homeopathic preparations of copper sulfate (CuSO(4); 11c-30c), quartz (SiO(2); 10c-30c, i.e., centesimal dilution steps) and sulfur (S; 11×-30×, i.e., decimal dilution steps) and controls (one-time succussed diluent) were investigated using UV-spectroscopy and tested for contamination by inductively coupled plasma mass spectrometry (ICP-MS). The UV transmission for homeopathic preparations of CuSO(4) preparations was significantly lower than in controls. The transmission seemed to be also lower for both SiO(2) and S, but not significant. The mean effect size (95% confidence interval) was similar for the homeopathic preparations: CuSO(4) (pooled data) 0.0544% (0.0260-0.0827%), SiO(2) 0.0323% (-0.0064% to 0.0710%) and S 0.0281% (-0.0520% to 0.1082%). UV transmission values of homeopathic preparations had a significantly higher variability compared to controls. In none of the samples the concentration of any element analyzed by ICP-MS exceeded 100 ppb. Lower transmission of UV light may indicate that homeopathic preparations are less structured or more dynamic than their succussed pure solvent.