986 resultados para CTD, Falmouth Scientific Instruments


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe an experimental demonstration of a novel technique for liquid refractometry. A channeled spectrum is produced from an optical beam generated by a diode laser operating below threshold by intercepting half of the beam with a liquid cell. The spectrum is analyzed using a grating and a linear CCD array and provides information on the refractive index of the liquid. The experimental results show that accuracies of better than 0.3% in the index may be obtained with the present method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a novel form of liquid refractometer in which the optical length of a cavity containing the liquid is monitored interferometrically.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present an imaging system based on light emitting diode (LED) illumination that produces multispectral optical images of the human ocular fundus. It uses a conventional fundus camera equipped with a high power LED light source and a highly sensitive electron-multiplying charge coupled device camera. It is able to take pictures at a series of wavelengths in rapid succession at short exposure times, thereby eliminating the image shift introduced by natural eye movements (saccades). In contrast with snapshot systems the images retain full spatial resolution. The system is not suitable for applications where the full spectral resolution is required as it uses discrete wavebands for illumination. This is not a problem in retinal imaging where the use of selected wavelengths is common. The modular nature of the light source allows new wavelengths to be introduced easily and at low cost. The use of wavelength-specific LEDs as a source is preferable to white light illumination and subsequent filtering of the remitted light as it minimizes the total light exposure of the subject. The system is controlled via a graphical user interface that enables flexible control of intensity, duration, and sequencing of sources in synchrony with the camera. Our initial experiments indicate that the system can acquire multispectral image sequences of the human retina at exposure times of 0.05 s in the range of 500-620 nm with mean signal to noise ratio of 17 dB (min 11, std 4.5), making it suitable for quantitative analysis with application to the diagnosis and screening of eye diseases such as diabetic retinopathy and age-related macular degeneration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polyzwitterionic-containing hydrogel materials been proposed for use in biomaterial applications. Polyzwitterions contain anions and cations in the same monomeric unit, unlike polyampholytes which contain them in different monomeric units. The use of cationic and anionic monomers in stoichiometrically equivalent proportions produces charge-balanced polyampholytes (PA) copolymers. Membranes prepared using either betaine-containing (BT) polyzwitterionic copolymers or PA copolymers can share similar properties, but the range of EWCs offered by membranes incorporating BT and PA monomers is greater than that for conventional neutral hydrogels and methacrylic acid-based systems. Here we compare properties of BT-containing and PA-containing copolymer membranes, relevant to their potential as biomedical materials. Membranes of the copolymers were prepared as previously described. Surface energy was determined using a GBX Digidrop (GBX Scientific Instruments), with diidomethane and water as probes. The absorption of proteins was determined by soaking the membranes in 1mg/ml protein solutions for a predetermined time, and measuring UV absorption of the membranes at certain wavelengths. The BT and PA copolymer membranes displayed similar values for the polar components and dispersive components of total surface free energy. This was perhaps not surprising when the structures of the monomers were considered. The BT and PA copolymer membranes displayed differences in their protein absorption over time, with the PA demonstrating higher uptake of protein than the BT. In addition to the aforementioned greater EWC range, the use of BT and PA copolymer membranes also avoids some of the problems associated with net anionicity. Comparison of the BT copolymer with the “pseudo” zwitterionic PA copolymers shows that controlled molecular architecture is required to gain the benefits of balancing the charges present in the copolymers in a way that will make them beneficial to hydrogel design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A catalytic reactor for the trapping of free radicals originating from gas phase catalytic reactions is described and discussed. Radical trapping and identification were initially carried out using a known radical generator such as dicumyl peroxide. The trapping of radicals was further demonstrated by investigating genuine radical oxidation processes, e.g., benzaldehyde oxidation over manganese and cobalt salts. The efficiency of the reactor was finally proven by the partial oxidation of cyclohexane over MoO3, Cr2O3, and WO3, which allowed the identification of all the radical intermediates responsible for the formation of the products cyclohexanol and cyclohexanone. Assignment of the trapped radicals was carried out using spin trapping technique and X -band electron paramagnetic resonance spectroscopy. © 2010 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe an experimental demonstration of a novel technique for liquid refractometry. A channeled spectrum is produced from an optical beam generated by a diode laser operating below threshold by intercepting half of the beam with a liquid cell. The spectrum is analyzed using a grating and a linear CCD array and provides information on the refractive index of the liquid. The experimental results show that accuracies of better than 0.3% in the index may be obtained with the present method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles’ impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5–58 MeV carbon ions and for protons in the energy range2–17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energiesE>~ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on the experimental characterisation of laser-driven ion beams using a Thomson Parabola Spectrometer (TPS) equipped with trapezoidally shaped electric plates, proposed by Gwynne et al. [Rev. Sci. Instrum. 85, 033304 (2014)]. While a pair of extended (30 cm long) electric plates was able to produce a significant increase in the separation between neighbouring ion species at high energies, deploying a trapezoidal design circumvented the spectral clipping at the low energy end of the ion spectra. The shape of the electric plate was chosen carefully considering, for the given spectrometer configuration, the range of detectable ion energies and species. Analytical tracing of the ion parabolas matches closely with the experimental data, which suggests a minimal effect of fringe fields on the escaping ions close to the wedged edge of the electrode. The analytical formulae were derived considering the relativistic correction required for the high energy ions to be characterised using such spectrometer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Telescopic Eye: Aqua Optica was an installation work which explores concepts and philosophies related to instrumental, lens based observations of heavens as experienced when seeing through a telescope. In particular it considers how the eye of the observer and the lens of the telescope must act in unison to extend both the perception and conception of that which is remote and beyond direct naked eye sensing - an act of transcendence. A series of projected images (the video) of celestial objects are observed by the viewer through a large spherical aquatic lens which is mounted on a large wooden tripod. These images slowly dissolve and morph into each other. The sequence in which these images are presented is based on approximate chronological order in which these celestial objects were historically observed through the telescope – such as the local bodies of our the solar system starting with the Moon, Jupiter and Saturn (as first observed by Galileo in 1610) and eventually extending out to distant nebula, star clusters and galaxies. For the Transduction exhibition the Telescopic Eye: Aqua Optica was installed outside in a small quadrangle next to the Tech Bar and as the night drew darker it was able to also embody the lighting and other visual elements from the surrounding buildings and streets. The Aqua Optica system often encompasses such local lighting and images as a added layer to the video projection work. In this case (at night and outside at Federation Square) the extent of the layering was very successful and increased dramatically as the night became darker. This multi layering of images invokes (for the viewer) a connection between the immediate environment of the Federation square and cityscape with the vastly distant images of the cosmos. For me such a multilayered imaging represents how scientific instruments of observation can generate a complex and augmented visualisation of reality, one which has historically come to re-define our conception of the cosmos and our place in it both spatially and temporally.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This chapter describes two cases, one from Germany and the other from Australia in which science journals were used in classrooms that adopted an inquiry-based approach to teaching science. We are interested in the following research questions:1. In what ways do teachers use journals to promote student learning of science?2. What evidence of reasoning is present in the cases in respect of the use of learning journals?3. When and in which form is feedback given in journals?

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Preterm infants have an increased risk of low bone mass and subsequent fracture due to limited bone mass accretion in utero and a greater need for bone nutrients. The diagnosis of ostepeonia of prematurity remains difficult as there is no sctreening test which is both sensitive and specific.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Antibiotic overuse is a global public health issue that is influenced by several factors. The degree and prevalence of antibiotic overuse is difficult to measure directly. A more practical approach, such as the use of a psycho-social measurement instrument, might allow for the observation and assessment of patterns of antibiotic use. Study objective: The aim of this paper is to review the nature, validity, and reliability of measurement scales designed to measure factors associated with antibiotic misuse/overuse. Design: This study is descriptive and includes a systematic integration of the measurement scales used in the literature to measure factors associated with antibiotic misuse/overuse. The review included 70 international scientific publications from 1992 to 2010. Main results: Studies have presented scales to measure antibiotic misuse. However, the workup of these instruments is often not mentioned, or the scales are used with only early-phase validation, such as content or face validity. Other studies have discussed the reliability of these scales. However, the full validation process has not been discussed in any of the reviewed measurement scales. Conclusion: A reliable, fully validated measurement scale must be developed to assess the factors associated with the overuse of antibiotics. Identifying these factors will help to minimize the misuse of antibiotics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The International Classification of Functioning, Disability and Health (ICF) assumes a biopsychosocial basis for disability and provides a framework for understanding how environmental factors contribute to the experience of disability. To determine the utility of prevalent disability assessment instruments, the authors examined the extent to which a range of such instruments addressed the impact of environmental factors on the individual and whether the instruments designed for different disability groups focused differentially on the environment. Items from 20 widely used disability assessment instruments were linked to the five chapters of the ICF environment component using standardized classification rules. Nineteen of the 20 instruments reviewed measured the environment to varying degrees. It was determined that environmental factors from the Natural Environment and Attitudes chapters were not well accommodated by the majority of instruments. Instruments developed for people with intellectual disabilities had the greatest environmental coverage. Only one instrument provided a relatively comprehensive and economical account of environmental barriers. The authors conclude that ICF classification of environmental factors provides a valuable resource for evaluating the environmental content of existing disability-related instruments, and that it may also provide a useful framework for revising instruments in use and for developing future disability assessment instruments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis presents an interdisciplinary analysis of how models and simulations function in the production of scientific knowledge. The work is informed by three scholarly traditions: studies on models and simulations in philosophy of science, so-called micro-sociological laboratory studies within science and technology studies, and cultural-historical activity theory. Methodologically, I adopt a naturalist epistemology and combine philosophical analysis with a qualitative, empirical case study of infectious-disease modelling. This study has a dual perspective throughout the analysis: it specifies the modelling practices and examines the models as objects of research. The research questions addressed in this study are: 1) How are models constructed and what functions do they have in the production of scientific knowledge? 2) What is interdisciplinarity in model construction? 3) How do models become a general research tool and why is this process problematic? The core argument is that the mediating models as investigative instruments (cf. Morgan and Morrison 1999) take questions as a starting point, and hence their construction is intentionally guided. This argument applies the interrogative model of inquiry (e.g., Sintonen 2005; Hintikka 1981), which conceives of all knowledge acquisition as process of seeking answers to questions. The first question addresses simulation models as Artificial Nature, which is manipulated in order to answer questions that initiated the model building. This account develops further the "epistemology of simulation" (cf. Winsberg 2003) by showing the interrelatedness of researchers and their objects in the process of modelling. The second question clarifies why interdisciplinary research collaboration is demanding and difficult to maintain. The nature of the impediments to disciplinary interaction are examined by introducing the idea of object-oriented interdisciplinarity, which provides an analytical framework to study the changes in the degree of interdisciplinarity, the tools and research practices developed to support the collaboration, and the mode of collaboration in relation to the historically mutable object of research. As my interest is in the models as interdisciplinary objects, the third research problem seeks to answer my question of how we might characterise these objects, what is typical for them, and what kind of changes happen in the process of modelling. Here I examine the tension between specified, question-oriented models and more general models, and suggest that the specified models form a group of their own. I call these Tailor-made models, in opposition to the process of building a simulation platform that aims at generalisability and utility for health-policy. This tension also underlines the challenge of applying research results (or methods and tools) to discuss and solve problems in decision-making processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Earth's ecosystems are protected from the dangerous part of the solar ultraviolet (UV) radiation by stratospheric ozone, which absorbs most of the harmful UV wavelengths. Severe depletion of stratospheric ozone has been observed in the Antarctic region, and to a lesser extent in the Arctic and midlatitudes. Concern about the effects of increasing UV radiation on human beings and the natural environment has led to ground based monitoring of UV radiation. In order to achieve high-quality UV time series for scientific analyses, proper quality control (QC) and quality assurance (QA) procedures have to be followed. In this work, practices of QC and QA are developed for Brewer spectroradiometers and NILU-UV multifilter radiometers, which measure in the Arctic and Antarctic regions, respectively. These practices are applicable to other UV instruments as well. The spectral features and the effect of different factors affecting UV radiation were studied for the spectral UV time series at Sodankylä. The QA of the Finnish Meteorological Institute's (FMI) two Brewer spectroradiometers included daily maintenance, laboratory characterizations, the calculation of long-term spectral responsivity, data processing and quality assessment. New methods for the cosine correction, the temperature correction and the calculation of long-term changes of spectral responsivity were developed. Reconstructed UV irradiances were used as a QA tool for spectroradiometer data. The actual cosine correction factor was found to vary between 1.08-1.12 and 1.08-1.13. The temperature characterization showed a linear temperature dependence between the instrument's internal temperature and the photon counts per cycle. Both Brewers have participated in international spectroradiometer comparisons and have shown good stability. The differences between the Brewers and the portable reference spectroradiometer QASUME have been within 5% during 2002-2010. The features of the spectral UV radiation time series at Sodankylä were analysed for the time period 1990-2001. No statistically significant long-term changes in UV irradiances were found, and the results were strongly dependent on the time period studied. Ozone was the dominant factor affecting UV radiation during the springtime, whereas clouds played a more important role during the summertime. During this work, the Antarctic NILU-UV multifilter radiometer network was established by the Instituto Nacional de Meteorogía (INM) as a joint Spanish-Argentinian-Finnish cooperation project. As part of this work, the QC/QA practices of the network were developed. They included training of the operators, daily maintenance, regular lamp tests and solar comparisons with the travelling reference instrument. Drifts of up to 35% in the sensitivity of the channels of the NILU-UV multifilter radiometers were found during the first four years of operation. This work emphasized the importance of proper QC/QA, including regular lamp tests, for the multifilter radiometers also. The effect of the drifts were corrected by a method scaling the site NILU-UV channels to those of the travelling reference NILU-UV. After correction, the mean ratios of erythemally-weighted UV dose rates measured during solar comparisons between the reference NILU-UV and the site NILU-UVs were 1.007±0.011 and 1.012±0.012 for Ushuaia and Marambio, respectively, when the solar zenith angle varied up to 80°. Solar comparisons between the NILU-UVs and spectroradiometers showed a ±5% difference near local noon time, which can be seen as proof of successful QC/QA procedures and transfer of irradiance scales. This work also showed that UV measurements made in the Arctic and Antarctic can be comparable with each other.