950 resultados para Buck boost inverter
Resumo:
The frequency responses of two 50 Hz and one 400 Hz induction machines have been measured experimentally over a frequency range of 1 kHz to 400 kHz. This study has shown that the stator impedances of the machines behave in a similar manner to a parallel resonant circuit, and hence have a resonant point at which the Input impedance of the machine is at a maximum. This maximum impedance point was found experimentally to be as low as 33 kHz, which is well within the switching frequency ranges of modern inverter drives. This paper investigates the possibility of exploiting the maximum impedance point of the machine, by taking it into consideration when designing an inverter, in order to minimize ripple currents due to the switching frequency. Minimization of the ripple currents would reduce torque pulsation and losses, increasing overall performance. A modified machine model was developed to take into account the resonant point, and this model was then simulated with an inverter to demonstrate the possible advantages of matching the inverter switching frequency to the resonant point. Finally, in order to experimentally verify the simulated results, a real inverter with a variable switching frequency was used to drive an induction machine. Experimental results are presented.
Resumo:
I defend the buck-passing account of value from Dancy's critique.
Resumo:
There are approximately 29,000 ha of grass buffer strips in the UK under Agri-Environment Schemes; however, typically they are floristically poor and as such are of limited biodiversity value. Introducing a sown wildflower component has the potential to increase dramatically the value of these buffer strips for a suite of native species, including butterflies. This study investigates management practices aiming to promote the establishment and maintenance of wildflowers in existing buffer strips. The effectiveness of two methods used to increase the establishment of wildflowers for the benefit of native butterfly species were tested, both individually and in combination. The management practices were: (1) the application of a selective graminicide (fluazifop-P-butyl) which reduces the dominance of competitive grasses; and (2) scarification of the soil which creates germination niches for sown wildflower seeds. A wildflower seed mix consisting of nine species was sown in conjunction with the scarification treatment. Responses of wildflowers and butterflies were monitored for two years after establishment. Results indicate that the combined scarification and graminicide treatment produced the greatest cover and species richness of sown wildflowers. Butterfly abundance, species richness and diversity were positively correlated with sown wildflower species richness, with the highest values in the combined scarification and graminicide treatment. These findings have confirmed the importance of both scarification as a means of introducing wildflower seed into existing buffer strips, and subsequent management using graminicides, for the benefit of butterflies. Application of this approach could provide tools to help butterfly conservation on farmland in the future.
Resumo:
A Bond Graph is a graphical modelling technique that allows the representation of energy flow between the components of a system. When used to model power electronic systems, it is necessary to incorporate bond graph elements to represent a switch. In this paper, three different methods of modelling switching devices are compared and contrasted: the Modulated Transformer with a binary modulation ratio (MTF), the ideal switch element, and the Switched Power Junction (SPJ) method. These three methods are used to model a dc-dc Boost converter and then run simulations in MATLAB/SIMULINK. To provide a reference to compare results, the converter is also simulated using PSPICE. Both quantitative and qualitative comparisons are made to determine the suitability of each of the three Bond Graph switch models in specific power electronics applications
Resumo:
In this paper, Bond Graphs are employed to develop a novel mathematical model of conventional switched-mode DC-DC converters valid for both continuous and discontinuous conduction modes. A unique causality bond graph model of hybrid models is suggested with the operation of the switch and the diode to be represented by a Modulated Transformer with a binary input and a resistor with fixed conductance causality. The operation of the diode is controlled using an if-then function within the model. The extracted hybrid model is implemented on a Boost and Buck converter with their operations to change from CCM to DCM and to return to CCM. The vector fields of the models show validity in a wide operation area and comparison with the simulation of the converters using PSPICE reveals high accuracy of the proposed model, with the Normalised Root Means Square Error and the Maximum Absolute Error remaining adequately low. The model is also experimentally tested on a Buck topology.
Resumo:
The buck-passing account of value involves a positive and a negative claim. The positive claim is that to be good is to have reasons for a pro-attitude. The negative claim is that goodness itself is not a reason for a pro-attitude. Unlike Scanlon, Parfit rejects the negative claim. He maintains that goodness is reason-providing, but that the reason provided is not an additional reason, additional, that is, to the reason provided by the good-making property. I consider various ways in which this may be understood and reject all of them. So I conclude that buck-passers cannot reject the negative claim.
Resumo:
Os controles de capitais estão novamente em voga em razão dos países emergentes reintroduzirem essas medidas nos últimos anos face a abundante entrada de capital internacional. As autoridades argumentam que tais medidas protegem as economias no caso de uma “parada abrupta” desses fluxos. Será demonstrado que os controles de capitais parecem fazer com que as economias emergentes (EMEs) fiquem mais resistentes diante de uma crise financeira (por exemplo, uma queda na atividade econômica seguida de uma crise é menor quando o controle é maior). No entanto, os controles de capitais parecem deixar as economias emergentes (EMEs) também mais propícias a uma crise. Deste modo, as autoridades devem ser cautelosas na avaliação quanto aos riscos e benefícios relativos a aplicação das medidas dos controles de capitais.
Resumo:
Capital controls are again in vogue as a number of emerging markets have reintroduced these measures in recent years in response to a “flood” of international capital. Policymakers use these tools to buttress their economies against the “sudden stop” risk that accompanies international capital flows. Using a panel VAR model, we show that capital controls appear to make emerging market economies (EMEs) more resistant to financial crises by showing that lower post-crisis output loss is correlated with stronger capital controls. However, EMEs that employ capital controls seem to be more crisis-prone. Thus, policymakers should carefully evaluate whether the benefits of capital controls outweigh their costs.
Resumo:
This work deals with the development of an experimental study on a power supply of high frequency that provides the toch plasmica to be implemented in PLASPETRO project, which consists of two static converters developed by using Insulated Gate Bipolar Transistor (IGBT). The drivers used to control these keys are triggered by Digital Signal Processor (DSP) through optical fibers to reduce problems with electromagnetic interference (EMI). The first stage consists of a pre-regulator in the form of an AC to DC converter with three-phase boost power factor correction which is the main theme of this work, while the second is the source of high frequency itself. A series-resonant inverter consists of four (4) cell inverters operating in a frequency around 115 kHz each one in soft switching mode, alternating itself to supply the load (plasma torch) an alternating current with a frequency of 450 kHz. The first stage has the function of providing the series-resonant inverter a DC voltage, with the value controlled from the power supply provided by the electrical system of the utility, and correct the power factor of the system as a whole. This level of DC bus voltage at the output of the first stage will be used to control the power transferred by the inverter to the load, and it may vary from 550 VDC to a maximum of 800 VDC. To control the voltage level of DC bus driver used a proportional integral (PI) controller and to achieve the unity power factor it was used two other proportional integral currents controllers. Computational simulations were performed to assist in sizing and forecasting performance. All the control and communications needed to stage supervisory were implemented on a DSP