941 resultados para Bag Sampling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined how marine plankton interaction networks, as inferred by multivariate autoregressive (MAR) analysis of time-series, differ based on data collected at a fixed sampling location (L4 station in the Western English Channel) and four similar time-series prepared by averaging Continuous Plankton Recorder (CPR) datapoints in the region surrounding the fixed station. None of the plankton community structures suggested by the MAR models generated from the CPR datasets were well correlated with the MAR model for L4, but of the four CPR models, the one most closely resembling the L4 model was that for the CPR region nearest to L4. We infer that observation error and spatial variation in plankton community dynamics influenced the model performance for the CPR datasets. A modified MAR framework in which observation error and spatial variation are explicitly incorporated could allow the analysis to better handle the diverse time-series data collected in marine environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data on the abundance and biomass of zooplankton off the northwestern Portuguese coast, separately estimated with a Longhurst-Hardy Plankton Recorder (LHPR) and a Bongo net, were analysed to assess the comparative performance of the samplers. Zooplankton was collected along four transects perpendicular to the coast, deployments alternating between samplers. Total zooplankton biomass measured using the LHPR was significantly higher than that using the Bongo net. Apart from Appendicularia and Cladocera, abundances of other taxa (Copepoda, Mysidacea, Euphausiacea, Decapoda larvae, Amphipoda, Siphonophora, Hydromedusae, Chaetognatha and Fish eggs) were also consistently higher in the LHPR. Some of these differences were probably due to avoidance by the zooplankton of the Bongo net. This was supported by a comparative analysis of prosome length of the copepod Calanus helgolandicus sampled by the two nets that showed that Calanus in the LHPR samples were on average significantly larger, particularly in day samples. A ratio estimator was used to produce a factor to convert Bongo net biomass and abundance estimates to equate them with those taken with the LHPR. This method demonstrates how results from complementary zooplankton sampling strategies can be made more equivalent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Largely used as a natural biological tag in studies of dispersal/connectivity of fish, otolith elemental fingerprinting is usually analyzed by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). LA-ICP-MS produces an elemental fingerprint at a discrete time-point in the life of a fish and can generate data on within-otolith variability of that fingerprint. The presence of within-otolith variability has been previously acknowledged but not incorporated into experimental designs on the presumed, but untested, grounds of both its negligibility compared to among-otolith variability and of spatial autocorrelation among multiple ablations within an otolith. Here, using a hierarchical sampling design of spatial variation at multiple scales in otolith chemical fingerprints for two Mediterranean coastal fishes, we explore: 1) whether multiple ablations within an otolith can be used as independent replicates for significance tests among otoliths, and 2) the implications of incorporating within-otolith variability when assessing spatial variability in otolith chemistry at a hierarchy of spatial scales (different fish, from different sites, at different locations on the Apulian Adriatic coast). We find that multiple ablations along the same daily rings do not necessarily exhibit spatial dependency within the otolith and can be used to estimate residual variability in a hierarchical sampling design. Inclusion of within-otolith measurements reveals that individuals at the same site can show significant variability in elemental uptake. Within-otolith variability examined across the spatial hierarchy identifies differences between the two fish species investigated, and this finding leads to discussion of the potential for within-otolith variability to be used as a marker for fish exposure to stressful conditions. We also demonstrate that a 'cost'-optimal allocation of sampling effort should typically include some level of within-otolith replication in the experimental design. Our findings provide novel evidence to aid the design of future sampling programs and improve our general understanding of the mechanisms regulating elemental fingerprints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Species size distributions for metazoan benthic invertebrates conform to the highly conservative bimodal pattern, regardless of the sieve mesh sizes or numbers of sieves used in their extraction. This pattern is not an artefact of sampling a size continuum as suggested by computer simulations using just 2 fixed mesh sizes in Bett (2013; Mar Ecol Prog Ser 487:1-6). Meiobenthos and macrobenthos are coherent entities, each with a distinct suite of functional attributes, and should not be regarded as a single unit for ecological modelling purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ocean Sampling Day was initiated by the EU-funded Micro B3 (Marine Microbial Biodiversity, Bioinformatics, Biotechnology) project to obtain a snapshot of the marine microbial biodiversity and function of the world's oceans. It is a simultaneous global mega-sequencing campaign aiming to generate the largest standardized microbial data set in a single day. This will be achievable only through the coordinated efforts of an Ocean Sampling Day Consortium, supportive partnerships and networks between sites. This commentary outlines the establishment, function and aims of the Consortium and describes our vision for a sustainable study of marine microbial communities and their embedded functional traits.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a series of N-chloro-acetylated dipeptides were synthesised by the application of Houghten's methodology of multiple analog peptide syntheses. The peptides, all of which contain a C-terminal free acid, were tested as inactivators of bovine cathepsin B, in an attempt at exploiting the known and, amongst the cysteine proteinases, unique carboxy dipeptidyl peptidase activity of the protease. We have succeeded in obtaining a number of effective inactivators, the most potent of which-chloroacetyl-Leu-Leu-OH, inactivates the enzyme with an apparent second-order rate constant of 3.8 x 10(4) M-1 min(-1). In contrast, the esterified analog, chloroacetyl-Leu-Leu-OMe, inactivates the enzyme some three orders of magnitude less efficiently, lending credence to our thesis that a free carboxylic acid moiety is an important determinant for inhibitor effectiveness. This preliminary study has highlighted a number of interesting features about the specificity requirements of the bovine proteinase and we believe that our approach has great potential for the rapid delineation of the subsite specificities of cathepsin B-like proteases from various species. (c) 2005 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Closing feedback loops using an IEEE 802.11b ad hoc wireless communication network incurs many challenges sensitivity to varying channel conditions and lower physical transmission rates tend to limit the bandwidth of the communication channel. Given that the bandwidth usage and control performance are linked, a method of adapting the sampling interval based on an 'a priori', static sampling policy has been proposed and, more significantly, assuring stability in the mean square sense using discrete-time Markov jump linear system theory. Practical issues including current limitations of the 802.11 b protocol, the sampling policy and stability are highlighted. Simulation results on a cart-mounted inverted pendulum show that closed-loop stability can be improved using sample rate adaptation and that the control design criteria can be met in the presence of channel errors and severe channel contention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 37-m thick layer of stratified clay encountered during a site investigation at Swann's Bridge, near the sea-coast at Limavady, Northern Ireland, is one of the deepest and thickest layers of this type of material recorded in Ireland. A study of the relevant literature and stratigraphic evidence obtained from the site investigation showed that despite being close to the current shoreline, the clay was deposited in a fresh-water glacial lake formed approximately 13 000 BP. The 37-m layer of clay can be divided into two separate zones. The lower zone was deposited as a series of laminated layers of sand, silt, and clay, whereas the upper zone was deposited as a largely homogeneous mixture. A comprehensive series of tests was carried out on carefully selected samples from the full thickness of the deposit. The results obtained from these tests were complex and confusing, particularly the results of tests done on samples from the lower zone. The results of one-dimensional compression tests, unconsolidated undrained triaxial tests, and consolidated undrained triaxial compression tests showed that despite careful sampling, all of the specimens from the lower zone exhibited behaviour similar to that of reconstituted clays. It was immediately clear that the results needed explanation. This paper studies possible causes of the results from tests carried out on the lower Limavady clay. It suggests a possible mechanism based on anisotropic elasticity, yielding, and destructuring that provides an understanding of the observed behaviour.Key words: clay, laminations, disturbance, yielding, destructuring, reconstituted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of a study aimed at determining the most important experimental parameters for automated, quantitative analysis of solid dosage form pharmaceuticals (seized and model 'ecstasy' tablets) are reported. Data obtained with a macro-Raman spectrometer were complemented by micro-Raman measurements, which gave information on particle size and provided excellent data for developing statistical models of the sampling errors associated with collecting data as a series of grid points on the tablets' surface. Spectra recorded at single points on the surface of seized MDMA-caffeine-lactose tablets with a Raman microscope (lambda(ex) = 785 nm, 3 mum diameter spot) were typically dominated by one or other of the three components, consistent with Raman mapping data which showed the drug and caffeine microcrystals were ca 40 mum in diameter. Spectra collected with a microscope from eight points on a 200 mum grid were combined and in the resultant spectra the average value of the Raman band intensity ratio used to quantify the MDMA: caffeine ratio, mu(r), was 1.19 with an unacceptably high standard deviation, sigma(r), of 1.20. In contrast, with a conventional macro-Raman system (150 mum spot diameter), combined eight grid point data gave mu(r) = 1.47 with sigma(r) = 0.16. A simple statistical model which could be used to predict sigma(r) under the various conditions used was developed. The model showed that the decrease in sigma(r) on moving to a 150 mum spot was too large to be due entirely to the increased spot diameter but was consistent with the increased sampling volume that arose from a combination of the larger spot size and depth of focus in the macroscopic system. With the macro-Raman system, combining 64 grid points (0.5 mm spacing and 1-2 s accumulation per point) to give a single averaged spectrum for a tablet was found to be a practical balance between minimizing sampling errors and keeping overhead times at an acceptable level. The effectiveness of this sampling strategy was also tested by quantitative analysis of a set of model ecstasy tablets prepared from MDEA-sorbitol (0-30% by mass MDEA). A simple univariate calibration model of averaged 64 point data had R-2 = 0.998 and an r.m.s. standard error of prediction of 1.1% whereas data obtained by sampling just four points on the same tablet showed deviations from the calibration of up to 5%.