748 resultados para BIS-GMA POLYMER
Resumo:
[1868-1870] (1871)
Resumo:
T.2 (1906)
Resumo:
Bd.2 (1811)
Resumo:
Perineural and intraneural fibrosis is thought to be the main cause of failure of the many surgical treatments of neuropathic pain. We have used Adcon-T/N carbohydrate polymer gel for prevention of perineural fibrosis in several parts of the body. In this retrospective study, 54 patients who presented with postoperative neuropathic pain had microsurgical epineural neurolysis and relocation of a terminal neuroma. In 19 of them, the carbohydrate gel was applied at the same time. The mean follow-up was four years and the nerve distribution varied. Postoperative improvement in pain scores (visual analogue scale (VAS) and neuropathic pain scale inventory (NPSI)), sensitivity, overall improvement and satisfaction were equivalent in the two groups, with pain relief in about 80% of the patients. There was no significant beneficial effect in the carbohydrate gel group. Patients treated with this device had a higher infection rate (21 compared with 0, p = 0.01) and delayed wound healing (31.6 compared with 11.8, p = 0.2). We conclude that good long-term pain relief is obtained postoperatively independently of the addition of carbohydrate gel. There was a slight but not significant trend towards profound pain relief with the gel.
Resumo:
Aquest article tracta el tema del “ne bis in idem” com a garantia processal penal del sistema interamericà de protecció dels drets humans. Tot fent referència als casos portats a la Cort Inteamericana de Drets Humans, s’hi presenten algunes consideracions que s’han tingut en compte a l’hora de flexibilitzar-ne el principi. Aquesta garantia es compara amb el sistema del “double jeopardy” de la common law. Així mateix, es compara també amb altres sistemes de protecció dels drets humans, com l’europeu, el del Tribunal Penal Internacional i el del Pacte de Drets Civils i Polítics de les Nacions Unides. Per concloure, es destaca la importància de l’harmonització de les garanties del procés penal en relació amb la discussió de conflictes jurisdiccionals. Aquest text és fruit de les reflexions debatudes Durand el curs de postgrau de la Facultat de Dret de la Universitat de São Paulo, “As Garantias do Processo Penal no Sistema Interamericano de Direitos Humanos”, 2008.
Resumo:
Este artículo trata el tema del ne bis in idem como garantía procesal penal dentro del sistema interamericano de protección de los derechos humanos. Haciendo referencia a los casos llevados ante la Corte Interamericana de Derechos Humanos, se presentan algunas reflexiones que fueron tomadas en consideración para la flexibilización del principio. Esta garantía se compara con el sistema del “double jeopardy” de la common law. Asimismo, se compara también con otros sistemas de protección de los derechos humanos, como el europeo, el del Tribunal Penal Internacional y el del Pacto de Derechos Civiles y Políticos de las Naciones Unidas. Finalmente, se destaca la importancia de la armonización de garantías del proceso penal en la discusión de conflictos jurisdiccionales. Este texto es producto de las reflexiones debatidas en el curso de postgrado de la Facultad de Derecho de la Universidad de São Paulo, “As Garantias do Processo Penal no Sistema Interamericano de Direitos Humanos”, 2008.
Resumo:
Static incubation tests, where microcapsules and beads are contacted with polymer and protein solutions, have been developed for the characterization of permselective materials applied for bioartificial organs and drug delivery. A combination of polymer ingress, detected by size-exclusion chromatography, and protein ingress/ egress, assessed by gel electrophoresis, provides information regarding the diffusion kinetics, molar mass cutoff(MMCO) and permeability. This represents an improvement over existing permeability measurements that are based on the diffusion of a single type of solute. Specifically, the permeability of capsules based on alginate, cellulose sulfate, polymethylene-co-guanidine were characterized as a function of membrane thickness. Solid alginate beads were also evaluated. The MMCO of these capsules was estimated to be between 80 and 90 kDa using polymers, and between 116-150 kDa with proteins. Apparently, the globular shape of the proteins (radius of gyration (Rg) of 4.2-4.6 nm) facilitates their passage through the membrane, comparatively to the polysaccharide coil conformation (Rg of 6.5-8.3 nm). An increase of the capsule membrane thickness reduced these values. The MMCO of the beads, which do not have a membrane limiting their permselective properties, was higher, between 110 and 200 kDa with dextrans, and between 150 and 220 kDa with proteins. Therefore, although the permeability estimated with biologically relevant molecules is generally higher due to their lower radius of gyration, both the MMCO of synthetic and natural watersoluble polymers correlate well, and can be used as in vitro metrics for the immune protection ability of microcapsules and microbeads. This article shows, to the authors' knowledge, the first reported concordance between permeability measures based on model natural and biological macromolecules.
Resumo:
BACKGROUND: carbon nanotubes (CNT) can have adverse effects on health. Therefore, minimizing the risk associated with CNT exposure is of crucial importance. The aim of this work was to evaluate if coating multi-walled CNT (MWCNT) with polymers could modify their toxicity, thus representing a useful strategy to decrease adverse health effects of CNT. We used industrially-produced MWCNT uncoated (NT1) or coated (50/50 wt%) with acid-based (NT2) or polystyrene-based (NT3) polymer, and exposed murine macrophages (RAW 264.7 cell line) or Balb/c mice by intratracheal administration. Biological experiments were performed both in vitro and in vivo, examining time- and dose-dependent effects of CNT, in terms of cytotoxicity, expression of genes and proteins related to oxidative stress, inflammation and tissue remodeling, cell and lung tissue morphology (optical and transmission electron microscopy), and bronchoalveolar lavage fluid content analysis.RESULTS: extensive physico-chemical characterization of MWCNT was performed, and showed, although similar dimensions for the 3 MWCNT, a much smaller specific surface area for NT2 and NT3 as compared to NT1 (54.1, 34 and 227.54 m(2)/g respectively), along with different surface characteristics. MWCNT-induced cytotoxicity, oxidative stress, and inflammation were increased by acid-based and decreased by polystyrene-based polymer coating both in vitro in murine macrophages and in vivo in lung of mice monitored for 6 months.CONCLUSIONS: these results demonstrate that coating CNT with polymers, without affecting their intrinsic structure, may constitute a useful strategy for decreasing CNT toxicity, and may hold promise for improving occupational safety and that of general the user.
Resumo:
Using numerical simulations we investigate shapes of random equilateral open and closed chains, one of the simplest models of freely fluctuating polymers in a solution. We are interested in the 3D density distribution of the modeled polymers where the polymers have been aligned with respect to their three principal axes of inertia. This type of approach was pioneered by Theodorou and Suter in 1985. While individual configurations of the modeled polymers are almost always nonsymmetric, the approach of Theodorou and Suter results in cumulative shapes that are highly symmetric. By taking advantage of asymmetries within the individual configurations, we modify the procedure of aligning independent configurations in a way that shows their asymmetry. This approach reveals, for example, that the 3D density distribution for linear polymers has a bean shape predicted theoretically by Kuhn. The symmetry-breaking approach reveals complementary information to the traditional, symmetrical, 3D density distributions originally introduced by Theodorou and Suter.
Resumo:
En aquest treball s’ha plantejat estudiar la capacitat de diferents bissulfonamides per promoure, actuant com a àcids Brønsted, l’addició estereoselectiva d’un grup al·lil o un indole a un catió acilimini. Per això, s’han sintetitzat diversos tipus de bis-sulfonamides amb simetria C2, en forma enantiopura, i preparat precursors genèrics de cations N-acilimini. S’han dut a terme reaccions d’al·lilació i d’addició d’indole en diferents condicions i amb les diferents sulfonamides. Es va estudiar la possible estereoselectivitat dels productes d’addició, però en cap cas la presència de les bis-sulfonamides sintetitzades en la reacció ha afectat a l’estereoselectivitat de les addicions.
Resumo:
The case of a 38-year old man with recurrent adenocarcinoma of the right lung and infiltration of the thoracic wall, who underwent a right pneumonectomy with thoracic wall resection, is described. Dissection of the right pulmonary hilous was extremely difficult due to the previous operations. The superior vena cava (SVC) was accidentally ligated, resulting in profound hypotension and increased venous pressure in the internal jugular vein. Immediate blood aspiration through a 8.5-French introducer sheath lowered the venous congestion. After the SVC was cross-clamped, the Bispectral Index (BIS) acutely decreased to 0 and remained low during the resuscitation. Over the next 5 hours, BIS was directly affected by mean arterial pressure. Four days postoperatively, the patient was neurologically intact.