973 resultados para B ... n C ... f.


Relevância:

70.00% 70.00%

Publicador:

Resumo:

In a search for regulatory proteins that interact with the leucine zipper motif of c-Fos in the yeast two-hybrid screen, we have identified a protein (FZA-B) that has extensive sequence similarity to SUG1 of Saccharomyces cerevisiae. Here we show that FZA-B can functionally substitute for SUG1 in yeast and that FZA-B interacts with Fos proteins in vitro through their leucine zippers. In rat liver and in HeLa cells, FZA-B is present in the 26S proteasome complex, as is c-Fos. Immobilized antibody raised against an FZA-B-specific peptide depleted peptidase activity, proteasomal proteins, FZA-B, and c-Fos from a 26S proteasome preparation. FZA-B is found predominantly in the nuclear fraction of COS cells expressing an FZA-B transgene and in the nuclear 26S proteasome of HeLa cells. We conclude that FZA-B is the mammalian homolog of SUG1 (mSug1) and that it is present in the nuclear 26S proteasome of cells. Our results suggest that mSug1 may be involved in the degradation of c-Fos and other transcription factors.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Oral administration of autoantigens can prevent and partially suppress autoimmune diseases in a number of experimental models, Depending on the dose of antigen fed, this approach appears to involve distinct yet reversible and short-lasting mechanisms (anergy/deletion and suppression) and usually requires repeated feeding of large (suppression) to massive (anergy/deletion) amounts of autoantigens to be effective. Most importantly, this approach is relatively less effective in animals already systemically sensitized to the fed antigen, such as in animals already harboring autoreactive T cells and, thus, presumably also in humans suffering from an autoimmune disorder. We have previously shown that feeding a single dose of minute amounts of antigens conjugated to cholera toxin B subunit (CTB) can effectively suppress delayed-type hypersensitivity reactions in systemically immune animals. We now report that feeding small amounts of myelin basic protein (MBP) conjugated to CTB either before or after disease induction protected rats from experimental autoimmune encephalomyelitis. Such treatment was as effective in suppressing interleukin 2 production and proliferative responses of lymph node cells to MBP as treatment involving repeated feeding with much larger (50- to 100-fold) doses of free MBP. Different from the latter treatment, which led to decreased production of interferon-gamma in lymph nodes, low-dose oral CTB-MBP treatment was associated with increased interferon-gamma production. Most importantly, low-dose oral CTB-MBP treatment greatly reduced the level of leukocyte infiltration into spinal cord tissue compared with treatment with repeated feeding of large doses of MBP. These results suggest that the protection from experimental autoimmune encephalomyelitis achieved by feeding CTB-conjugated myelin autoantigen involves immunomodulating mechanisms that are distinct from those implicated by conventional protocols of oral tolerance induction.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aus der Sammlung des Leo Baeck Institute, digitalisiert in Kooperation mit dem Center for Jewish History, NY

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aus der Sammlung des Leo Baeck Institute, digitalisiert in Kooperation mit dem Center for Jewish History, NY

Relevância:

70.00% 70.00%

Publicador:

Resumo:

von Dr. H.P. Chajes

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This prospective study evaluated serum procalcitonin (PCT) and C-reactive protein (CRP) as markers for systemic inflammatory response syndrome (SIRS)/sepsis and mortality in patients with traumatic brain injury and subarachnoid haemorrhage. Sixty-two patients were followed for 7 days. Serum PCT and CRP were measured on days 0, 1, 4, 5, 6 and 7. Seventy-seven per cent of patients with traumatic brain injury and 83% with subarachnoid haemorrhage developed SIRS or sepsis (P= 0.75). Baseline PCT and CRP were elevated in 35% and 55% ofpatients respectively (P=0.03). There was a statistically non-significant step-wise increase in serum PCT levels from no SIRS (0.4 +/- 0.6 ng/ml) to SIRS (3.05 +/- 9.3 ng/ml) to sepsis (5.5 +/- 12.5 ng/ml). A similar trend was noted in baseline PCT in patients with mild (0.06 +/- 0.9 ng/ml), moderate (0.8 +/- 0.7 ng/ml) and severe head injury (1.2 +/- 1.9 ng/ml). Such a gradation was not observed with serum CRP There was a non-significant trend towards baseline PCT being a better marker of hospital mortality compared with baseline CRP (ROC-AUC 0.56 vs 0.31 respectively). This is the first prospective study to document the high incidence of SIRS in neurosurgical patients. In our study, serum PCT appeared to correlate with severity of traumatic brain injury and mortality. However, it could not reliably distinguish between SIRS and sepsis in this cohort. This is in pan because baseline PCT elevation seemed to correlate with severity of injury. Only a small proportion ofpatients developed sepsis, thus necessitating a larger sample size to demonstrate the diagnostic usefulness of serum PCT as a marker of sepsis. Further clinical trials with larger sample sizes are required to confirm any potential role of PCT as a sepsis and outcome indicator in patients with head injuries or subarachnoid haemorrhage.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Aim: To rapidly quantify hepatitis B virus (HBV) DNA by real-time PCR using efficient TaqMan probe and extraction methods of virus DNA. Methods: Three standards were prepared by cloning PCR products which targeted S, C and X region of HBV genome into pGEM-T vector respectively. A pair of primers and matched TaqMan probe were selected by comparing the copy number and the Ct values of HBV serum samples derived from the three different standard curves using certain serum DNA. Then the efficiency of six HBV DNA extraction methods including guanidinium isothiocyanate, proteinase K, NaI, NaOH lysis, alkaline lysis and simple boiling was analyzed in sample A, B and C by real-time PCR. Meanwhile, 8 clinical HBV serum samples were quantified. Results: The copy number of the same HBV serum sample originated from the standard curve of S, C and X regions was 5.7 × 104/ mL, 6.3 × 102/mL and 1.6 × 103/mL respectively. The relative Ct value was 26.6, 31.8 and 29.5 respectively. Therefore, primers and matched probe from S region were chosen for further optimization of six extraction methods. The copy number of HBV serum samples A, B and C was 3.49 × 109/mL, 2.08 × 106/mL and 4.40 × 107/mL respectively, the relative Ct value was 19.9, 30 and 26.2 in the method of NaOH lysis, which was the efficientest among six methods. Simple boiling showed a slightly lower efficiency than NaOH lysis. Guanidinium isothiocyanate, proteinase K and NaI displayed that the copy number of HBV serum sample A, B and C was around 105/ mL, meanwhile the Ct value was about 30. Alkaline failed to quantify the copy number of three HBV serum samples, Standard deviation (SD) and coefficient variation (CV) were very low in all 8 clinical HBV serum samples, showing that quantification of HBV DNA in triplicate was reliable and accurate. Conclusion: Real-time PCR based on optimized primers and TaqMan probe from S region in combination with NaOH lysis is a simple, rapid and accurate method for quantification of HBV serum DNA. © 2006 The WJG Press. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

New information on possible resource value of sea floor manganese nodule deposits in the eastern north Pacific has been obtained by a study of records and collections of the 1972 Sea Scope Expedition. Nodule abundance (percent of sea floor covered) varies greatly, according to photographs from eight stations and data from other sources. All estimates considered reliable are plotted on a map of the region. Similar maps show the average content of Ni, Cu, Mn and Co at 89 stations from which three or more nodules were analyzed. Variations in nodule metal content at each station are shown graphically in an appendix, where data on nodule sizes are also given. Results of new analyses of 420 nodules from 93 stations for mn, fe, ni, cu, CO, and zn are listed in another appendix. Relatively high Ni + Cu content is restricted chiefly to four groups of stations in the equatorial region, where group averages are 1.86, 1.99, 2.47, and 2.55 weight-percent. Prepared for United States Department of the Interior, Bureau of Mines. Grant no. GO284008-02-MAS. - NTIS PB82-142571.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper uses survey data to explore employee satisfaction with working time arrangements within a large supermarket chain in Queensland. The findings confirm those in the literature that employees have a diverse range of working time preferences, and that employees will be more satisfied if those preferences are met by their employer. In general, many full-time employees wanted shorter hours and a sizeable proportion of part-time employees wanted longer working hours. This paper is a preliminary attempt at teasing out the explanations behind working time preferences.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective The review addresses two distinct sets of issues: 1. specific functionality, interface, and calculation problems that presumably can be fixed or improved; and 2. the more fundamental question of whether the system is close to being ready for ‘commercial prime time’ in the North American market. Findings Many of our comments relate to the first set of issues, especially sections B and C. Sections D and E deal with the second set. Overall, we feel that LCADesign represents a very impressive step forward in the ongoing quest to link CAD with LCA tools and, more importantly, to link the world of architectural practice and that of environmental research. From that perspective, it deserves continued financial support as a research project. However, if the decision is whether or not to continue the development program from a purely commercial perspective, we are less bullish. In terms of the North American market, there are no regulatory or other drivers to press design teams to use a tool of this nature. There is certainly interest in this area, but the tools must be very easy to use with little or no training. Understanding the results is as important in this regard as knowing how to apply the tool. Our comments are fairly negative when it comes to that aspect. Our opinion might change to some degree when the ‘fixes’ are made and the functionality improved. However, as discussed in more detail in the following sections, we feel that the multi-step process — CAD to IFC to LCADesign — could pose a serious problem in terms of market acceptance. The CAD to IFC part is impossible for us to judge with the information provided, and we can’t even begin to answer the question about the ease of using the software to import designs, but it appears cumbersome from what we do know. There does appear to be a developing North American market for 3D CAD, with a recent survey indicating that about 50% of the firms use some form of 3D modeling for about 75% of their projects. However, this does not mean that full 3D CAD is always being used. Our information suggests that AutoDesk accounts for about 75 to 80% of the 3D CAD market, and they are very cautious about any links that do not serve a latent demand. Finally, other system that link CAD to energy simulation are using XML data transfer protocols rather than IFC files, and it is our understanding that the market served by AutoDesk tends in that direction right now. This is a subject that is outside our area of expertise, so please take these comments as suggestions for more intensive market research rather than as definitive findings.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Relatively little research attention has been given to the development of standardised and psychometrically sound scales for measuring influences relevant to the utilisation of health services. This study aims to describe the development, validation and internal reliability of some existing and new scales to measure factors that are likely to influence utilisation of preventive care services provided by general practitioners in Australia.----- Methods: Relevant domains of influence were first identified from a literature review and formative research. Items were then generated by using and adapting previously developed scales and published findings from these. The new items and scales were pre-tested and qualitative feedback was obtained from a convenience sample of citizens from the community and a panel of experts. Principal Components Analyses (PCA) and internal reliability testing (Cronbach's alpha) were then conducted for all of the newly adapted or developed scales utilising data collected from a self-administered mailed survey sent to a randomly selected population-based sample of 381 individuals (response rate 65.6 per cent).----- Results: The PCA identified five scales with acceptable levels of internal consistency were: (1) social support (ten items), alpha 0.86; (2) perceived interpersonal care (five items), alpha 0.87, (3) concerns about availability of health care and accessibility to health care (eight items), alpha 0.80, (4) value of good health (five items), alpha 0.79, and (5) attitudes towards health care (three items), alpha 0.75.----- Conclusion The five scales are suitable for further development and more widespread use in research aimed at understanding the determinants of preventive health services utilisation among adults in the general population.