920 resultados para Aortic Valve Stenosis


Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Stroke is a major cause of morbidity and mortality during open-heart surgery. Up to 60% of intraoperative cerebral events are emboli induced. This randomized, controlled, multicenter trial is the first human study evaluating the safety and efficacy of a novel aortic cannula producing simultaneous forward flow and backward suction for extracting solid and gaseous emboli from the ascending aorta and aortic arch upon their intraoperative release. METHODS Sixty-six patients (25 females; 68±10 years) undergoing elective aortic valve replacement surgery, with or without coronary artery bypass graft surgery, were randomized to the use of the CardioGard (CardioGard Medical, Or-Yehuda, Israel) Emboli Protection cannula ("treatment") or a standard ("control") aortic cannula. The primary endpoint was the volume of new brain lesions measured by diffusion-weighted magnetic resonance imaging (DW-MRI), performed preoperatively and postoperatively. Device safety was investigated by comparisons of complications rate, namely neurologic events, stroke, renal insufficiency and death. RESULTS Of 66 patients (34 in the treatment group), 51 completed the presurgery and postsurgery MRI (27 in the treatment group). The volume of new brain lesion for the treatment group was (mean±standard error of the mean) 44.00±64.00 versus 126.56±28.74 mm3 in the control group (p=0.004). Of the treatment group, 41% demonstrated new postoperative lesions versus 66% in the control group (p=0.03). The complication rate was comparable in both groups. CONCLUSIONS The CardioGard cannula is safe and efficient in use during open-heart surgery. Efficacy was demonstrated by the removal of a substantial amount of emboli, a significant reduction in the volume of new brain lesions, and the percentage of patients experiencing new brain lesions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hintergund Seit mehr als 10 Jahren wird der kathetergestützte Aortenklappenersatz (Transkatheter-Aortenklappenimplantation, „transcatheter aortic valve implantation“, TAVI) durchgeführt. Bereits in der Anfangsphase haben sich eingriffstypische Komplikationen nach transfemoralem Zugang herauskristallisiert. Ziel der Arbeit Beispielhaft wird anhand von 4 Sektionsfällen beschrieben, wie die Indikationsstellung zur TAVI und die Vermeidbarkeit der Komplikation zu prüfen ist. Material und Methoden Bei einer 86-jährigen Frau war es im Rahmen eines Repositionsversuchs des Implantats zu einem Abriss der rechten Beckengefäße gekommen. Bei einer 82-jährigen Frau war es während der Intervention zu einem Einriss des Aortenklappenrings mit Perikardtamponade gekommen. Eine 89-jährige Frau erlitt während der Intervention eine gedeckte Aortenverletzung und war während der anschließenden operativen Versorgung des Defekts verstorben. Im vierten Fall war bei einer 83 Jahre alt gewordenen Patientin im Rahmen des transfemoralen Klappenersatzes die Positionierung der Klappe misslungen, und ventrikelwärts entwickelte sich eine Embolisation der entfalteten Klappe. Es wurde eine zweite gleichartige Klappe positioniert, die in der Aorta hielt. Ergebnisse Die Indikationsstellung zur TAVI war in den 4 Fällen der multimorbiden Patientinnen gerechtfertigt. Die Komplikationen waren sehr unterschiedlich und die Gefäßverletzungen in 2 Fällen aufgrund der begonnenen Operationen nicht mehr zu prüfen. Schlussfolgerungen Die Versorgung einer Komplikation ist beim indikationsgerechten Patientenkollektiv aufgrund der Multimorbidität extrem schwierig und mit zahlreichen weiteren Komplikationen behaftet. Schlüsselwörter Herzklappenerkrankungen – Herzklappenprothese – Minimalinvasive Verfahren – Behandlungsfehler – Inoperabilität

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Ventricular arrhythmias (VAs) from the left ventricular outflow tract (LVOT) region can be inaccessible for ablation because of epicardial fat or overlying coronary arteries. OBJECTIVE We describe surgical cryoablation of this type of VA. METHODS From March 2009 to 2014, 190 consecutive patients with VAs originating from the LVOT underwent ablation at our institution. Four patients (2%) underwent surgical cryoablation for highly symptomatic VAs after failing catheter ablation. RESULTS In all patients, endocardial or percutaneous epicardial mapping was consistent with origin in the LVOT. In 2 patients, the points of earliest activation during VAs were marked with a bipolar pacing lead in the overlying cardiac vein for guidance during surgery. Surgical cryoablation was successful in 3 of the 4 patients. The fourth patient subsequently had successful endocardial catheter ablation. During a mean follow-up of 22 ± 16 months (range 4-42 months), all patients showed abolition of or marked reduction in symptomatic VA. However, 1 patient subsequently required percutaneous intervention to the left anterior descending coronary artery; another developed progressive left ventricular systolic dysfunction caused by nonischemic cardiomyopathy; and a third patient underwent permanent pacemaker implantation because of complete atrioventricular block after concomitant aortic valve replacement. CONCLUSION Surgical cryoablation is an option for highly symptomatic drug-resistant VAs emanating from the LVOT region. Despite extensive preoperative mapping, the procedure is not effective for all patients, and coronary injury is a risk.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The first derivative of pressure over time (dP/dt) is a marker of left ventricular (LV) systolic function that can be assessed during cardiac catheterization and echocardiography. Radial artery dP/dt (Radial-dP/dt) has been proposed as a possible marker of LV systolic function (Nichols & O’Rourke, McDonald’s Blood Flow in Arteries) and we sought to test this hypothesis. Methods:We compared simultaneously recorded RadialdP/ dt (by high-fidelity tonometry) with LV-dP/dt (by highfidelity catheter and echocardiography parameters analogous to LV-dP/dt) in patients without aortic valve disease. In study 1, beat to beat Radial-dP/dt and LV-dP/dt were recorded at rest and during supine exercise in 12 males (aged 61±12 years) undergoing cardiac catheterization. In study 2, 2D-echocardiography and Radial-dP/dt were recorded in 59 patients (43 men; aged 64±10 years) at baseline and peak dobutamine-induced stress. Three measures at the basal septum were taken as being analogous to LV-dP/dt: (1) peak systolic strain rate, (2) strain rate (SR-dP/dt), and (3) tissue velocity during isovolumic contraction. Results: Study 1; there was a significant difference between resting LV-dP/dt (1461±383 mmHg/s) and Radial-dP/dt (1182±319 mmHg/s; P < 0.001), and a poor, but statistically significant, correlation between the variables (R2 = 0.006; P < 0.001) due to the high number of data points compared (n = 681). Similar results were observed during exercise. Study 2; there was a moderate association between baseline Radial-dP/dt and SRdP/ dt (R2 =−0.17; P < 0.01), but no significant relationship between Radial-dP/dt and all other echocardiographic measures analogous to LV-dP/dt at rest or peak stress (P > 0.05). Conclusion: The radial pressurewaveform is not a reliable marker of LV contractility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cardiovascular disease (CVD) continues to be one of the top causes of mortality in the world. World Heart Organization (WHO) reported that in 2004, CVD contributed to almost 30% of death from estimated worldwide death figures of 58 million[1]. Heart failure treatment varies from lifestyle adjustment to heart transplantation; its aims are to reduce HF symptoms, prolong patient survival and minimize risk [2]. One alternative available in the market for HF treatment is Left Ventricular Assist Device (LVAD). Chronic Intermittent Mechanical Support (CIMS) device is a novel (LVAD) heart failure treatment using counterpulsation similar to Intra Aortic Balloon Pumps (IABP). However, the implantation site of the CIMS balloon is in the ascending aorta just distal to aortic valve contrasted with IABP in the descending aorta. Counterpulsation coupled with implantation close to the aortic valve enables comparable flow augmentation with reduced balloon volume. Two prototypes of the CIMS balloon were constructed using rapid prototyping: the straight-body model is a cylindrical tube with a silicone membrane lining with zero expansive compliance. The compliant-body model had a bulging structure that allowed the membrane to expand under native systolic pressure increasing the device’s static compliance to 1.5 mL/mmHg. This study examined the effect of device compliance and vascular compliance on counterpulsating flow augmentation. Both prototypes were tested on a two-element Windkessel model human mock circulatory loop (MCL). The devices were placed just distal to aortic valve and left coronary artery. The MCL mimicked HF with cardiac output of 3 L/min, left ventricular pressure of 85/15 mmHg, aortic pressure of 70/50 mmHg and left coronary artery flow rate of 66 mL/min. The mean arterial pressure (MAP) was calculated to be 57 mmHg. Arterial compliance was set to be1.25 mL/mmHg and 2.5 mL/mmHg. Inflation of the balloon was triggered at the dicrotic notch while deflation was at minimum aortic pressure prior to systole. Important haemodynamics parameters such as left ventricular pressure (LVP), aortic pressure (AoP), cardiac output (CO), left coronary artery flowrate (QcorMean), and dP (Peak aortic diastolic augmentation pressure – AoPmax ) were simultaneously recorded for both non-assisted mode and assisted mode. ANOVA was used to analyse the effect of both factors (balloon and arterial compliance) to flow augmentation. The results showed that for cardiac output and left coronary artery flowrate, there were significant difference between balloon and arterial compliance at p < 0.001. Cardiac output recorded maximum output at 18% for compliant body and stiff arterial compliance. Left coronary artery flowrate also recorded around 20% increase due to compliant body and stiffer arterial compliance. Resistance to blood ejection recorded highest difference for combination of straight body and stiffer arterial compliance. From these results it is clear that both balloon and arterial compliance are statistically significant factors for flow augmentation on peripheral artery and reduction of resistance. Although the result for resistance reduction was different from flow augmentation, these results serves as an important aspect which will influence the future design of the CIMS balloon and its control strategy. References: 1. Mathers C, Boerma T, Fat DM. The Global Burden of disease:2004 update. Geneva: World Heatlh Organization; 2008. 2. Jessup M, Brozena S. Heart Failure. N Engl J Med 2003;348:2007-18.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Despite current recommendations, a high percentage of patients with severe symptomatic aortic stenosis are managed conservatively. The aim of this study was to study symptomatic patients undergoing conservative management from the IDEAS registry, describing their baseline clinical characteristics, mortality, and the causes according to the reason for conservative management. Consecutive patients with severe aortic stenosis diagnosed at 48 centers during January 2014 were included. Baseline clinical characteristics, echocardiographic data, Charlson index, and EuroSCORE-II were registered, including vital status and performance of valve intervention during one-year follow-up. For the purpose of this substudy we assessed symptomatic patients undergoing conservative management, including them in 5 groups according to the reason for performing conservative management [I: comorbidity/frailty (128, 43.8%); II: dementia 18 (6.2%); III: advanced age 34 (11.6%); IV: patients’ refusal 62 (21.2%); and V: other reasons 50 (17.1%)]. We included 292 patients aged 81.5 ± 9 years. Patients from group I had higher Charlson index (4 ± 2.3), higher EuroSCORE-II (7.5 ± 6), and a higher overall (42.2%) and non-cardiac mortality (16.4%) than the other groups. In contrast, patients from group III had fewer comorbidities, lower EuroSCORE-II (4 ± 2.5), and low overall (20.6%) and non-cardiac mortality (5.9%). Patients with severe symptomatic aortic stenosis managed conservatively have different baseline characteristics and clinical course according to the reason for performing conservative management. A prospective assessment of comorbidity and other geriatric syndromes might contribute to improve therapeutic strategy in this clinical setting.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: To analyze the potential contribution of contractility state and ventricular geometry to the development of heart failure in rats with aortic stenosis.Methods: Rats were divided into three groups: compensated aortic stenosis (AS, n = 11), heart failure AS (n = 12) and control rats (C, n = 13).Results: After 21 weeks, failing AS rats presented higher systolic (C = 36.6 +/- 3.1, AS-78.6 +/- 4.8*, failing AS = 104.6 +/- 7.8*) and diastolic meridian stress (C = 6.9 +/- 0.4, AS = 20.1 +/- 1.1*, failing AS = 43.2 +/- 3.2*(dagger)), hydroxyproline (C = 3.6 +/- 0.7 mg/g, AS = 6.6 +/- 0.6* mg/g, failing AS = 9.2 +/- 1.4*(dagger) mg/g) and cross-sectional area (C = 338 +/- 25 mu m(2), AS = 451 +/- 32* mu m(2), failing AS = 508 +/- 36*(dagger) mu m(2)), in comparison with control and compensated AS animals (*p < 0.05 vs. control, (dagger)p < 0.05 vs. AS). In the isometric contraction study, considering the time from peak tension to 50% relaxation (RT50), the relative variation responses, following post-rest contraction and increase in Ca2+ concentration, were higher in failing AS than compensated AS animals. In contrast, following post-rest contraction, compensated AS group presented higher values of the peak developed tension (DT) than failing AS group. Following beta-adrenergic stimulation, control animals presented higher values of +dT/dt and -dT/dt than AS animals. In addition, failing AS animals presented higher TPT values than compensated AS animals.Conclusion: Myocardial contractile dysfunction contributes to the development of heart failure in rats with aortic stenosis. (c) 2006 Elsevier B.V.. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)