960 resultados para Acrylic dentures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the double crown technique in removable prosthodontics. New ceramic materials like zirconia are increasingly used in combination with CAD/CAM technologies for framework fabrication of fixed prosthesis, tooth- or implant-supported. However, zirconia is also a newly accepted material in removable prosthodontics. It replaces gold alloys for the fabrication of primary telescopic crowns. The Galvanoforming technology is preferably used to fabricate the secondary crowns. The combination of both techniques and materials results in a prosthetic reconstruction of high quality, optimum fit and good biocompatibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On one side, prosthodontic reconstructions compensate for the sequelae of negative changes in the oral cavity; on the other side, they often enhance or accelerate them. As a consequence of negative changes in the oral cavity over time, treatment planning for RPDs becomes highly complex. A set of reliable criteria is necessary for decision-making and problem management It appears that the majority of published data on RPDs does not depict high effectiveness of this treatment modality. From a strict point of view of evidence-based dentistry, the level of evidence is low if not missing for RPDs. Randomized controlled trials on RPDs are difficult to design, they are not feasible for some questions due to the complexity of the material, or may remain without clinical relevance. The literature rarely gives information on the denture design, tooth selection, and management of the compromised structural integrity of teeth. So far treatment outcomes with RPDs must be considered under the aspect of bias due to the bias in indication and patient selection for RPDs. Better clinical models should be elaborated with more stringent concepts for providing RPDs. This encompasses: risk analysis and patient assessment, proper indications for maintenance or extraction of teeth, strategic placement of implants, biomechanical aspects, materials, and technology. Although there is a tendency to offer fixed prostheses to our patients, this might change again with demographic changes and with an increase in the ageing population, an increase in their reduced dentition, and low socioeconomic wealth in large parts of the world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to analyze prosthetic maintenance in partially edentulous patients with removable prostheses supported by teeth and strategic implants. MATERIALS AND METHODS: Sixty patients with removable partial prostheses and combined tooth-implant support were identified within the time period from 1998 to 2006. One group consisted of 42 patients (planned group) with a reduced residual dentition and in need of removable partial dentures (RPDs) or overdentures in the maxilla and/or mandible. They were admitted consecutively for treatment. Due to missing teeth in strategic important positions, one or two implants were placed to improve symmetrical denture support and retention. The majority of residual teeth exhibited an impaired structural integrity and therefore were provided with root copings for denture retention. A few vital teeth were used for telescopic crowns. The anchorage system for the strategic implants was selected accordingly. A second group of 18 patients (repair group) wearing RPDs with the loss of one abutment tooth due to biologic or mechanical failure was identified. These abutment teeth were replaced by 21 implants, and patients continued to wear their original prostheses. The observation time for planned and repair groups was 12 months to 8 years. All patients followed a regular maintenance schedule. Technical or biologic complications with supporting teeth or implants and prosthetic service were registered regularly. RESULTS: Three maxillary implants were lost after loading and three roots with copings had to be removed. Biologic problems included caries and periodontal/peri-implant infection with a significantly higher incidence in the repair group (P < .05). Technical complications with the dentures were rather frequent in both groups, mostly related to the anchorage system (matrices) of root copings and implants. Maintenance and complications were observed more frequently in the first year after delivery of the denture than in the following 3 years (P < .05). No denture had to be remade. CONCLUSIONS: The placement of a few implants allows for maintaining a compromised residual dentition for support of RPDs. The combination of root and implant support facilitates treatment planning and enhances designing the removable denture. It also proves to be a practical rescue method. Technical problems with the anchorage system were frequent, particularly in the first year after delivery of the dentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this research was to study the impact of loading on partial dentures within the supporting soft tissue with respect to different attachment techniques. A finite element model was developed to calculate the stress and strain distribution in this tissue. The model consisted of the left half of a mandible with three remaining teeth that had suffered an atrophy in the anterior region, and a partial denture over the toothless area that was connected at the left mandibular canine using an attachment system. Resulting stress/strain distributions are presented for different load cases using a commercially available prefabricated attachment system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This retrospective study reports the clinical outcome following placement of extraoral implants in severely resorbed posterior ridges to support distal-extension removable dentures. MATERIAL AND METHODS: Consecutively treated patients with partially or completely edentulous ridges, with available bone height in the posterior region of 6 mm or less, were included in the study. Implants originally intended for extraoral use (Straumann) were placed in second molar regions and allowed to heal for 4 to 6 months before abutment connection. At recall appointments, the peri-implant hard and soft tissues were evaluated. Complications with implant components, as well as mechanical and structural failures of the prostheses, were recorded. Two-year survival rates were calculated and life table analyses undertaken. RESULTS: Twenty-nine patients (19 women and 10 men; average age 61.2 years, range, 44 to 75 years) were included in the study. Forty-seven extraoral implants in 26 patients were placed in the second molar site of the mandible. Two extraoral implants in 2 patients failed during the osseointegration phase, yielding an 8-year cumulative success rate of 91.8%. The mean distance from the extraoral implants to the most distal tooth/implant was 28.1 mm (range, 16.7 to 39.2 mm). Twenty-three extraoral implants were restored with magnets, 18 with ball anchors, and 4 with conical cylinders. Replacement of abutments and retention elements was necessary in 2 patients. Four abutments in 2 patients were disconnected from the restorations. CONCLUSIONS: Within the limits of the employed research design, extraoral implants may be used successfully to provide support for distal-extension removable dentures in severely resorbed posterior alveolar ridges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present prospective clinical study was to compare patient-reported outcomes for maxillary conventional dentures and maxillary implant-supported dentures. MATERIAL AND METHODS Twenty-one patients (6 women and 15 men) being edentulous in the maxilla and encountering problems with their existing dentures were included. Twelve patients (4 women and 8 men) received a new set of conventional dentures, due to insufficient dentures. In nine patients (2 women and 7 men), the existing dentures were adjusted by means of relining or rebasing. All patients received implant-supported dentures on two retentive anchors. In total, 42 implants were inserted in the anterior maxilla. The participants rated their satisfaction on their existing conventional dentures, 2 months after insertion of new conventional dentures and 2 months after insertion of implant-supported dentures. Thereby, patients responded to questionnaires capturing the oral health impact profile (OHIP) using visual analog scales. Seven domains (functional limitation, physical pain, psychological discomfort, physical, psychological and social disability and handicap) were assessed. Higher scores implied poorer patient satisfaction. In addition, the questionnaire involved the evaluation of cleaning ability, general satisfaction, speech, comfort, esthetics, stability, and chewing ability. Higher scores implied higher patient satisfaction. RESULTS Patient satisfaction significantly increased for implant-supported dentures compared with old dentures in all seven OHIP subgroups, as well as for cleaning ability, general satisfaction, ability to speak, comfort, esthetics, and stability (P < 0.05). The comparison of new conventional dentures and implant-supported dentures revealed a statistically significantly increased satisfaction for functional limitation (difference of 33.2 mm), psychological discomfort (difference of 36.7 mm), physical disability (difference of 36.3 mm), and social disability (difference of 23.5 mm), (P < 0.05). Additionally, general satisfaction, chewing ability, speech, and stability significantly improved in implant-supported dentures (P < 0.05). CONCLUSIONS Within the limits of this study, maxillary dentures retained by two implants provided some significant short-term improvements over conventional dentures in oral- and health-related quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In adhesion, the wetting process depends on three fundamental factors: the surface topography of the adherend, the viscosity of the adhesive, and the surface energy of both. The aim of this paper is to study the influence of viscosity and surface roughness on the wetting and their effect on the bond strength. For this purpose, an acrylic adhesive with different viscosities was synthesized and some properties, such as viscosity and surface tension, were studied before adhesive curing took place. Furthermore, the contact angle and the lap-shear strength were analyzed using aluminum adherends with two different roughnesses. Scanning electron microscopy was used to determine the effect of the viscosity and the roughness on the joint interface. The results showed that the adhesive exhibits an optimal value of viscosity. Below this value, at low viscosities, the low neoprene content produces poor bond strength due to the reduced toughness of the adhesive. Additionally, it also produces a high shrinkage during curing, which leads to the apparition of residual stresses that weakens the interfacial strength. However, once the optimum value, an increase in the viscosity produces a negative effect on the joint strength as a result of an important decrease in the wettability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poster presented at the 1st International Congress of CiiEM - From Basic Sciences to Clinical Research, 27-28 November 2015, Egas Moniz, Caparica, Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) melt processed disks and solvent cast films were modified by graft co-polyinerization with acrylic acid (AAc) in methanol solution at ambient temperature using gamma irradiation (dose rate of 4.5 kGy/h). To assess the presence of carboxylic acid groups on the surface, reaction with pentafluorophenol was performed prior to X-ray photoelectron spectroscopy analysis. The grafting yield for all samples increased with monomer concentration (2-15%), and for the solvent cast films, it also increased with dose (2-9 kGy). However, the grafting yield of the melt processed disks was largely independent of the radiation dose (2-8 kGy). Toluidine blue was used to stain the modified materials facilitating, visual information about the extent of carboxylic acid functionalization and depth penetration of the grafted copolymer. Covalent linking of glucosamine to the functionalized surface was achieved using carbodimide chemistry verifying that the modified substrates are suitable for biomolecule attachment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High strength, high modulus carbon fibres are becoming increasingly important as high performance engineering materials. This thesis describes how they may be prepared by heat treatment from filaments spun from polyacrylonitrile and its copolymers. The chemistry of the first stages of heat treatment is very important in controlling the mechanical properties of the carbonised product. A cyclisation reaction has been found to be responsible for the relatively high thermal stability of pyrolysed polyacrylonitrile, but without oxidation the fibres degrade and fuse. An initial oxidation stage is, therefore, essential to the preparation of fibre of high orientation. The cyclised product of pyrolysis is probably a poly 1,4 dihydropiridine and oxidation converts this to aromatic structures, and cyclised structures containing carbonyl and other oxygenated groups. Oxidation is found to assist the carbon fibre preparation process, by producing a product which condenses at an earlier stage of heat treatment, before fusion can occur. Carbon fibre strength and modulus are dependent upon producing a highly oriented crystal structure. While oxidation of the polymer stabilises the fibre so as to prevent disorientation, further large increases in orientation, with a commensurate improvement in strength and modulus, can be obtained by stretching at temperatures above 1,700 °C. This process is analogous to the way fibre orientation is increased by the stretching of the precursor. A lamellar graphite structure can be created in high temperature fibre, by carefully controlling the degree of oxidation. This type of graphite can produce very high values of Young's modulus. More often, however, graphite fibre has a fibrillar fine structure, which is explicable in terms of continuous graphite ribbons. A ribbon model is the most satisfactory representation of the structure of carbon fibre, as it explains the mechanism of the development of long range order and the variation of Young's modulus with crystalline preferred orientation.