913 resultados para ASSISTED RESECTION
Resumo:
OBJECTIVE: To correlate the postoperative voice outcome to preoperative glottic involvement, following partial cricotracheal resection (PCTR) in children. The glottic involvement was analysed based on the extent of subglottic stenosis (SGS) in the endoscopic image and functional dynamic assessment using flexible endoscopy. METHODS: We conducted an interobserver study in which two ENT surgeons, blinded to one another's interpretation, independently rated the extent of SGS based on the endoscopic image along with the dynamic functional airway assessment, of 108 children who underwent PCTR for grade III or IV stenosis. Based on the observation, the glottic involvement was rated into 4 categories: Evaluation of the voice was based on a parent/patient proxy questionnaire sent in 2008 to assess the current functional status of the patient's voice. RESULTS: Among the 77 patients available for long-term outcome with a minimum 1-year follow-up, 31 patients had isolated SGS free from vocal cords (group A) and 30 had SGS reaching the under surface of vocal cords with partial or no impairment of abduction of vocal cords (group B). Twelve patients belonged to group C with posterior glottic stenosis and/or vocal cord fusion (without cricoarytenoid ankylosis) and 4 patients had transglottic stenosis and or/bilateral cricoarytenoid ankylosis (group D). The long-term voice outcome following PCTR as perceived by the parent or patient was normal in 18% (14 of 77 patients) and the remaining 63 patients demonstrated mild to severe dysphonia. Patients belonging to group A and B exhibited either normal voice or mild dysphonia. Patients in group C demonstrated dysphonia, which was moderate in severity in the majority (83%). All patients in group D with transglottic stenosis and/or CAA showed severe dysphonia. CONCLUSION: Children with associated glottic involvement are at high risk for poor voice outcome following PCTR. The severity of dysphonia was found to be proportional to the preoperative glottic involvement. Preoperative rating of the extent of glottic involvement based on endoscopic image and dynamic assessment was found to be useful in prognosticating the voice outcome.
Resumo:
Object Recent years have been marked by efforts to improve the quality and safety of pedicle screw placement in spinal instrumentation. The aim of the present study is to compare the accuracy of the SpineAssist robot system with conventional fluoroscopy-guided pedicle screw placement. Methods Ninety-five patients suffering from degenerative disease and requiring elective lumbar instrumentation were included in the study. The robot cohort (Group I; 55 patients, 244 screws) consisted of an initial open robot-assisted subgroup (Subgroup IA; 17 patients, 83 screws) and a percutaneous cohort (Subgroup IB, 38 patients, 161 screws). In these groups, pedicle screws were placed under robotic guidance and lateral fluoroscopic control. In the fluoroscopy-guided cohort (Group II; 40 patients, 163 screws) screws were inserted using anatomical landmarks and lateral fluoroscopic guidance. The primary outcome measure was accuracy of screw placement on the Gertzbein-Robbins scale (Grade A to E and R [revised]). Secondary parameters were duration of surgery, blood loss, cumulative morphine, and length of stay. Results In the robot group (Group I), a perfect trajectory (A) was observed in 204 screws (83.6%). The remaining screws were graded B (n = 19 [7.8%]), C (n = 9 [3.7%]), D (n = 4 [1.6%]), E (n = 2 [0.8%]), and R (n = 6 [2.5%]). In the fluoroscopy-guided group (Group II), a completely intrapedicular course graded A was found in 79.8% (n = 130). The remaining screws were graded B (n = 12 [7.4%]), C (n = 10 [6.1%]), D (n = 6 [3.7%]), and E (n = 5 [3.1%]). The comparison of "clinically acceptable" (that is, A and B screws) was neither different between groups (I vs II [p = 0.19]) nor subgroups (Subgroup IA vs IB [p = 0.81]; Subgroup IA vs Group II [p = 0.53]; Subgroup IB vs Group II [p = 0.20]). Blood loss was lower in the robot-assisted group than in the fluoroscopy-guided group, while duration of surgery, length of stay, and cumulative morphine dose were not statistically different. Conclusions Robot-guided pedicle screw placement is a safe and useful tool for assisting spine surgeons in degenerative spine cases. Nonetheless, technical difficulties remain and fluoroscopy backup is advocated.
Resumo:
New child wish after vasectomy: vasovasostomy or assisted reproductive medicine? In the case of a new child wish after vasectomy, there are two options: vaso-vasostomy (VV) or biopsy of the testicle associated with intra-cytoplasmatic sperm injection (ICSI). Both methods are not reimbursed. The VV offers a cumulative pregnancy rate of 28-40%, depending on pre-, intra- and postoperative factors. The age of the female partner and the time after vasectomy are the most important factors. Pregnancy rates after ICSI are 29-41% per transfer. Cumulative pregnancy rates vary between 60-80%. Malformation rates after ICSI in this special collective are not investigated yet, the "general" ICSI-collective differs completely compared to the a priori fertile couples after vasectomy. Couples have to inform themselves about the experience of the doctors and their rate of success in order to minimize the risk of failure.
Resumo:
Background. Early identification of pathogens from blood cultures using matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry may optimize the choice of empirical antibiotic therapy in the setting of bloodstream infections. We aimed to assess the impact of this new technology on the use of antibiotic treatment in patients with gram-negative bacteremia. Methods. We conducted a prospective observational study from January to December 2010 to evaluate the sequential and separate impacts of Gram stain reporting and MALDI-TOF bacterial identification performed on blood culture pellets in patients with gram-negative bacteremia. The primary outcome was the impact of MALDI-TOF on empirical antibiotic choice. Results. Among 202 episodes of gram-negative bacteremia, Gram stain reporting had an impact in 42 cases (20.8%). MALDI-TOF identification led to a modification of empirical therapy in 71 of all 202 cases (35.1%), and in 16 of 27 cases (59.3%) of monomicrobial bacteremia caused by AmpC-producing Enterobacteriaceae. The most frequently observed impact was an early appropriate broadening of the antibiotic spectrum in 31 of 71 cases (43.7%). In total, 143 of 165 episodes (86.7%) of monomicrobial bacteremia were correctly identified at genus level by MALDI-TOF. Conclusions. In a low prevalence area for extended spectrum betalactamases (ESBL) and multiresistant gram-negative bacteria, MALDI-TOF performed on blood culture pellets had an impact on the clinical management of 35.1% of all gram-negative bacteremia cases, demonstrating a greater impact than Gram stain reporting. Thus, MALDI-TOF could become a vital second step beside Gram stain in guiding the empirical treatment of patients with bloodstream infection.
Resumo:
We report here the case of a 55 year old female that underwent surgery for a well differentiated squamous cell carcinoma of the esophagus (middle third). Four months after surgery, she complains of neck pain, for which she is prescribed non steroidal antiinflammatory drugs (NSAID). A CT-scan and a Barium swallow are then normal. After three weeks of treatment, the patient is admitted on emergency to the Intensive Care Unit for a resuscitation hematemesis and atrial fibrillation with a fast ventricular response. The symptoms are stabilized after the transfusion of a few packed red blood cells. A few hours later, however, a massive hematemesis recurs and the patient dies despite intense resuscitation measures. Autopsy reveals three gastric ulcers, one of which had perforated through the cardiac left ventricular wall
Resumo:
Silver has been demonstrated to be a powerful cationization agent in mass spectrometry (MS) for various olefinic species such as cholesterol and fatty acids. This work explores the utility of metallic silver sputtering on tissue sections for high resolution imaging mass spectrometry (IMS) of olefins by laser desorption ionization (LDI). For this purpose, sputtered silver coating thickness was optimized on an assorted selection of mouse and rat tissues including brain, kidney, liver, and testis. For mouse brain tissue section, the thickness was adjusted to 23 ± 2 nm of silver to prevent ion suppression effects associated with a higher cholesterol and lipid content. On all other tissues, a thickness of at 16 ± 2 nm provided the best desorption/ionization efficiency. Characterization of the species by MS/MS showed a wide variety of olefinic compounds allowing the IMS of different lipid classes including cholesterol, arachidonic acid, docosahexaenoic acid, and triacylglyceride 52:3. A range of spatial resolutions for IMS were investigated from 150 μm down to the high resolution cellular range at 5 μm. The applicability of direct on-tissue silver sputtering to LDI-IMS of cholesterol and other olefinic compounds presents a novel approach to improve the amount of information that can be obtained from tissue sections. This IMS strategy is thus of interest for providing new biological insights on the role of cholesterol and other olefins in physiological pathways or disease.
Resumo:
BACKGROUND AND PURPOSE: Endovascular treatment of wide-neck bifurcation aneurysms often results in incomplete occlusion or aneurysm recurrence. The goals of this study were to compare results of coil embolization with or without the assistance of self-expandable stents and to examine how stents may influence neointima formation. MATERIALS AND METHODS: Wide-neck bifurcation aneurysms were constructed in 24 animals and, after 4-6 weeks, were randomly allocated to 1 of 5 groups: 1) coil embolization using the assistance of 1 braided stent (n = 5); 2) coil embolization using the assistance of 2 braided stents in a Y configuration (n = 5); 3) coil embolization without stent assistance (n = 6); 4) Y-stenting alone (n = 4); and 5) untreated controls (n = 4). Angiographic results were compared at baseline and at 12 weeks, by using an ordinal scale. Neointima formation at the neck at 12 weeks was compared among groups by using a semiquantitative grading scale. Bench studies were performed to assess stent porosities. RESULTS: Initial angiographic results were improved with single stent-assisted coiling compared with simple coiling (P = .013). Angiographic results at 12 weeks were improved with any stent assistance (P = .014). Neointimal closure of the aneurysm neck was similar with or without stent assistance (P = .908), with neointima covering coil loops but rarely stent struts. Y-stent placement alone had no therapeutic effect. Bench studies showed that porosities can be decreased with stent compaction, but a relatively stable porous transition zone was a limiting factor. CONCLUSIONS: Stent-assisted coiling may improve results of embolization by allowing more complete initial coiling, but these high-porosity stents did not provide a scaffold for more complete neointimal closure of aneurysms.
Resumo:
The self-assembled growth of GaN nanorods on Si (111) substrates by plasma-assisted molecular beam epitaxy under nitrogen-rich conditions is investigated. An amorphous silicon nitride layer is formed in the initial stage of growth that prevents the formation of a GaN wetting layer. The nucleation time was found to be strongly influenced by the substrate temperature and was more than 30 min for the applied growth conditions. The observed tapering and reduced length of silicon-doped nanorods is explained by enhanced nucleation on nonpolar facets and proves Ga-adatom diffusion on nanorod sidewalls as one contribution to the axial growth. The presence of Mg leads to an increased radial growth rate with a simultaneous decrease of the nanorod length and reduces the nucleation time for high Mg concentrations.
Resumo:
Use of assisted reproductive technology (ART) is increasing in many developed countries. Arterial and venous thromboembolic complications are reported during ART with an incidence of 0.1%. The development of these events has been mainly ascribed to the presence of ovarian hyperstimulation syndrome (OHSS). Precise mechanisms by which OHSS and exogenous hormonal stimulation used in ART induce thromboembolic events remain unclear. However, vascular endothelial growth factor secreted during OHSS, high estradiol concentrations, and blood hyperviscosity play a major role in inducing a prothrombotic state. Therefore, before planning an ART, individual thromboembolic risk should be assessed and thromboprophylaxis offered to high risk patients. Prophylaxis should be initiated in women who develop moderate-to-severe OHSS.
Resumo:
BACKGROUND: Assisted reproductive technology (ART) involves the manipulation of early embryos at a time when they may be particularly vulnerable to external disturbances. Environmental influences during the embryonic and fetal development influence the individual's susceptibility to cardiovascular disease, raising concerns about the potential consequences of ART on the long-term health of the offspring. METHODS AND RESULTS: We assessed systemic (flow-mediated dilation of the brachial artery, pulse-wave velocity, and carotid intima-media thickness) and pulmonary (pulmonary artery pressure at high altitude by Doppler echocardiography) vascular function in 65 healthy children born after ART and 57 control children. Flow-mediated dilation of the brachial artery was 25% smaller in ART than in control children (6.7±1.6% versus 8.6±1.7%; P<0.0001), whereas endothelium-independent vasodilation was similar in the 2 groups. Carotid-femoral pulse-wave velocity was significantly (P<0.001) faster and carotid intima-media thickness was significantly (P<0.0001) greater in children conceived by ART than in control children. The systolic pulmonary artery pressure at high altitude (3450 m) was 30% higher (P<0.001) in ART than in control children. Vascular function was normal in children conceived naturally during hormonal stimulation of ovulation and in siblings of ART children who were conceived naturally. CONCLUSIONS: Healthy children conceived by ART display generalized vascular dysfunction. This problem does not appear to be related to parental factors but to the ART procedure itself. CLINICAL TRIAL REGISTRATION: URL: www.clinicaltrials.gov. Unique identifier: NCT00837642.
Resumo:
A surgeon facing the problem of a child with subglottic stenosis currently has a wide range of surgical options. Cricotracheal resection is the preferred option for grade IV and severe grade III stenoses that are clear of the vocal cords. Laryngotracheal reconstruction as a less extensive procedure is preferred for some grade II and less severe grade III stenoses. Stenosis close to the vocal cords remains a challenge and can be treated by extended partial cricotracheal resection. Pediatric surgeons and otolaryngologists should learn carefully the technique of partial cricotracheal resection for use in infants and children to achieve better results than with laryngotracheal reconstructions.
Resumo:
Map units directly related to properties of soil-landscape are generated by local soil classes. Therefore to take into consideration the knowledge of farmers is essential to automate the procedure. The aim of this study was to map local soil classes by computer-assisted cartography (CAC), using several combinations of topographic properties produced by GIS (digital elevation model, aspect, slope, and profile curvature). A decision tree was used to find the number of topographic properties required for digital cartography of the local soil classes. The maps produced were evaluated based on the attributes of map quality defined as precision and accuracy of the CAC-based maps. The evaluation was carried out in Central Mexico using three maps of local soil classes with contrasting landscape and climatic conditions (desert, temperate, and tropical). In the three areas the precision (56 %) of the CAC maps based on elevation as topographical feature was higher than when based on slope, aspect and profile curvature. The accuracy of the maps (boundary locations) was however low (33 %), in other words, further research is required to improve this indicator.
Resumo:
Electrically assisted bicycles (EAB) are flourishing in cities throughout the world and capitalize on ecological and practical advantages, helping in the fight against pollution, CO2 emissions and traffic jam. Human power is necessary to activate the electrical support, so that it equals to a moderate intensity physical activity (> 3 MET), or a vigorous one on hilly courses (>6 MET). The ecological benefits are obvious and transportation departments tend to support citizens who purchase one. EAB offer increased mobility at speeds of 15 to 25 km/h depending on hills and fitness of the rider, but could cause more accidents. EAB is linked to a real physical activity beneficial for health, but potentially more dangerous than a traditional bicycle.
Resumo:
Purpose: Tumour-free resection margins (RMs) are mandatory in breast-conserving surgery. On-site intraoperative ultrasound (US)-guided tumour resection with extemporaneous histopathological assessment of RMs has been described. Remote intraoperative US assessment of RMs is an alternative. The purpose of this study was to evaluate the relationship of lumpectomy RMs measurements between remote intraoperative US and postoperative histopathology.Methods and Materials: In a retrospective IRB-approved review of 100 consecutive lumpectomies performed between October 2009 and April 2011 for presumed non-palpable breast cancer, 71 women (mean age 63.8years) were included. Twenty-nine patients were excluded because of absence of cancer at histopathology and/or incomplete data. Measurements of lumpectomy minimal RMs and tumour maximal diameter obtained on remote intraoperative US and postoperative histopathology were compared.Results: Minimal RMs were 0.35±0.32 (mean±SD) and 0.35±0.32cm on remote intraoperative US and postoperative histopathology, respectively. No significant difference was found between these measurements (p=0.37). Tumour maximal diameter was 1.02±0.51 (mean±SD) and 1.33±0.74cm on remote intraoperative US and postoperative histopathology, respectively. US measurements were significantly smaller (p<0.001). The 71 breast carcinoma (CA) consisted of: invasive canalar (n=49), invasive lobular (n=11), in situ (n=3) and other types of CA (n=8). Twenty-nine patients had intraoperative re-excision (24 without residual CA), while 16 patients were re-operated due to insufficient histopathological RMs (12 without residual CA).Conclusion: Good correlation of minimal RMs between remote intraoperative US and postoperative histopathology warrants use of both techniques in a complementary manner. Remote intraoperative US is helpful in taking rapid decision of re-excision and maintaining low re-operation rate after breast-conserving surgery for non-palpable cancer.
Resumo:
We present a high‐resolution electron microscopy study of the microstructure of boron nitride thin films grown on silicon (100) by radio‐frequency plasma‐assisted chemical vapor deposition using B2H6 (1% in H2) and NH3 gases. Well‐adhered boron nitride films grown on the grounded electrode show a highly oriented hexagonal structure with the c‐axis parallel to the substrate surface throughout the film, without any interfacial amorphous layer. We ascribed this textured growth to an etching effect of atomic hydrogen present in the gas discharge. In contrast, films grown on the powered electrode, with compressive stress induced by ion bombardment, show a multilayered structure as observed by other authors, composed of an amorphous layer, a hexagonal layer with the c‐axis parallel to the substrate surface and another layer oriented at random