874 resultados para ARTIFICIAL VENTILATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The automatic diagnostic discrimination is an application of artificial intelligence techniques that can solve clinical cases based on imaging. Diffuse liver diseases are diseases of wide prominence in the population and insidious course, yet early in its progression. Early and effective diagnosis is necessary because many of these diseases progress to cirrhosis and liver cancer. The usual technique of choice for accurate diagnosis is liver biopsy, an invasive and not without incompatibilities one. It is proposed in this project an alternative non-invasive and free of contraindications method based on liver ultrasonography. The images are digitized and then analyzed using statistical techniques and analysis of texture. The results are validated from the pathology report. Finally, we apply artificial intelligence techniques as Fuzzy k-Means or Support Vector Machines and compare its significance to the analysis Statistics and the report of the clinician. The results show that this technique is significantly valid and a promising alternative as a noninvasive diagnostic chronic liver disease from diffuse involvement. Artificial Intelligence classifying techniques significantly improve the diagnosing discrimination compared to other statistics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetically engineered bioreporters are an excellent complement to traditional methods of chemical analysis. The application of fluorescence flow cytometry to detection of bioreporter response enables rapid and efficient characterization of bacterial bioreporter population response on a single-cell basis. In the present study, intrapopulation response variability was used to obtain higher analytical sensitivity and precision. We have analyzed flow cytometric data for an arsenic-sensitive bacterial bioreporter using an artificial neural network-based adaptive clustering approach (a single-layer perceptron model). Results for this approach are far superior to other methods that we have applied to this fluorescent bioreporter (e.g., the arsenic detection limit is 0.01 microM, substantially lower than for other detection methods/algorithms). The approach is highly efficient computationally and can be implemented on a real-time basis, thus having potential for future development of high-throughput screening applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Clearance of alveolar oedema depends on active transport of sodium across the alveolar-epithelial barrier. beta-Adrenergic agonists increase clearance of pulmonary oedema, but it has not been established whether beta-agonist stimulation achieves sufficient oedema clearance to improve survival in animals. The objective of this study was to determine whether the increased pulmonary oedema clearance produced by intratracheal dopamine improves the survival of rats after mechanical ventilation with high tidal volume (HVT). METHODS This was a randomized, controlled, experimental study. One hundred and thirty-two Wistar-Kyoto rats, weighing 250 to 300 g, were anaesthetized and cannulated via endotracheal tube. Pulmonary oedema was induced by endotracheal instillation of saline solution and mechanical ventilation with HVT. Two types of experiment were carried out. The first was an analysis of pulmonary oedema conducted in six groups of 10 rats ventilated with low (8 ml/kg) or high (25 ml/kg) tidal volume for 30 or 60 minutes with or without intratracheally instilled dopamine. At the end of the experiment the animals were exsanguinated and pulmonary oedema analysis performed. The second experiment was a survival analysis, which was conducted in two groups of 36 animals ventilated with HVT for 60 minutes with or without intratracheal dopamine; survival of the animals was monitored for up to 7 days after extubation. RESULTS In animals ventilated at HVT with or without intratracheal dopamine, oxygen saturation deteriorated over time and was significantly higher at 30 minutes than at 60 minutes. After 60 minutes, a lower wet weight/dry weight ratio was observed in rats ventilated with HVT and instilled with dopamine than in rats ventilated with HVT without dopamine (3.9 +/- 0.27 versus 4.9 +/- 0.29; P = 0.014). Survival was significantly (P = 0.013) higher in animals receiving intratracheal dopamine and ventilated with HVT, especially at 15 minutes after extubation, when 11 of the 36 animals in the HVT group had died as compared with only one out of the 36 animals in the HVT plus dopamine group. CONCLUSION Intratracheal dopamine instillation increased pulmonary oedema clearance in rats ventilated with HVT, and this greater clearance was associated with improved survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Using a bench test model, we investigated the hypothesis that neonatal and/or adult ventilators equipped with neonatal/pediatric modes currently do not reliably administer pressure support (PS) in neonatal or pediatric patient groups in either the absence or presence of air leaks. METHODS: PS was evaluated in 4 neonatal and 6 adult ventilators using a bench model to evaluate triggering, pressurization, and cycling in both the absence and presence of leaks. Delivered tidal volumes were also assessed. Three patients were simulated: a preterm infant (resistance 100 cm H2O/L/s, compliance 2 mL/cm H2O, inspiratory time of the patient [TI] 400 ms, inspiratory effort 1 and 2 cm H2O), a full-term infant (resistance 50 cm H2O/L/s, compliance 5 mL/cm H2O, TI 500 ms, inspiratory effort 2 and 4 cm H2O), and a child (resistance 30 cm H2O/L/s, compliance 10 mL/cm H2O, TI 600 ms, inspiratory effort 5 and 10 cm H2O). Two PS levels were tested (10 and 15 cm H2O) with and without leaks and with and without the leak compensation algorithm activated. RESULTS: Without leaks, only 2 neonatal ventilators and one adult ventilator had trigger delays under a given predefined acceptable limit (1/8 TI). Pressurization showed high variability between ventilators. Most ventilators showed TI in excess high enough to seriously impair patient-ventilator synchronization (> 50% of the TI of the subject). In some ventilators, leaks led to autotriggering and impairment of ventilation performance, but the influence of leaks was generally lower in neonatal ventilators. When a noninvasive ventilation algorithm was available, this was partially corrected. In general, tidal volume was calculated too low by the ventilators in the presence of leaks; the noninvasive ventilation algorithm was able to correct this difference in only 2 adult ventilators. CONCLUSIONS: No ventilator performed equally well under all tested conditions for all explored parameters. However, neonatal ventilators tended to perform better in the presence of leaks. These findings emphasize the need to improve algorithms for assisted ventilation modes to better deal with situations of high airway resistance, low pulmonary compliance, and the presence of leaks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanical ventilation (MV) is life-saving but potentially harmful for lungs of premature infants. So far, animal models dealt with the acute impact of MV on immature lungs, but less with its delayed effects. We used a newborn rodent model including non-surgical and therefore reversible intubation with moderate ventilation and hypothesized that there might be distinct gene expression patterns after a ventilation-free recovery period compared to acute effects directly after MV. Newborn rat pups were subjected to 8 hr of MV with 60% oxygen (O(2) ), 24 hr after injection of lipopolysaccharide (LPS), intended to create a low inflammatory background as often recognized in preterm infants. Animals were separated in controls (CTRL), LPS injection (LPS), or full intervention with LPS and MV with 60% O(2) (LPS + MV + O(2) ). Lungs were recovered either directly following (T:0 hr) or 48 hr after MV (T:48 hr). Histologically, signs of ventilator-induced lung injury (VILI) were observed in LPS + MV + O(2) lungs at T:0 hr, while changes appeared similar to those known from patients with chronic lung disease (CLD) with fewer albeit larger gas exchange units, at T:48 hr. At T:0 hr, LPS + MV + O(2) increased gene expression of pro-inflammatory MIP-2. In parallel anti-inflammatory IL-1Ra gene expression was increased in LPS and LPS + MV + O(2) groups. At T:48 hr, pro- and anti-inflammatory genes had returned to their basal expression. MMP-2 gene expression was decreased in LPS and LPS + MV + O(2) groups at T:0 hr, but no longer at T:48 hr. MMP-9 gene expression levels were unchanged directly after MV. However, at T:48 hr, gene and protein expression increased in LPS + MV + O(2) group. In conclusion, this study demonstrates the feasibility of delayed outcome measurements after a ventilation-free period in newborn rats and may help to further understand the time-course of molecular changes following MV. The differences obtained from the two time points could be interpreted as an initial transitory increase of inflammation and a delayed impact of the intervention on structure-related genes. Pediatr Pulmonol. 2012; 47:1204-1214. © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Hemodynamic resuscitation should be aimed at achieving not only adequate cardiac output but also sufficient mean arterial pressure (MAP) to guarantee adequate tissue perfusion pressure. Since the arterial pressure response to volume expansion (VE) depends on arterial tone, knowing whether a patient is preload-dependent provides only a partial solution to the problem. The objective of this study was to assess the ability of a functional evaluation of arterial tone by dynamic arterial elastance (Ea(dyn)), defined as the pulse pressure variation (PPV) to stroke volume variation (SVV) ratio, to predict the hemodynamic response in MAP to fluid administration in hypotensive, preload-dependent patients with acute circulatory failure. METHODS We performed a prospective clinical study in an adult medical/surgical intensive care unit in a tertiary care teaching hospital, including 25 patients with controlled mechanical ventilation who were monitored with the Vigileo(®) monitor, for whom the decision to give fluids was made because of the presence of acute circulatory failure, including arterial hypotension (MAP ≤65 mmHg or systolic arterial pressure <90 mmHg) and preserved preload responsiveness condition, defined as a SVV value ≥10%. RESULTS Before fluid infusion, Ea(dyn) was significantly different between MAP responders (MAP increase ≥15% after VE) and MAP nonresponders. VE-induced increases in MAP were strongly correlated with baseline Ea(dyn) (r(2) = 0.83; P < 0.0001). The only predictor of MAP increase was Ea(dyn) (area under the curve, 0.986 ± 0.02; 95% confidence interval (CI), 0.84-1). A baseline Ea(dyn) value >0.89 predicted a MAP increase after fluid administration with a sensitivity of 93.75% (95% CI, 69.8%-99.8%) and a specificity of 100% (95% CI, 66.4%-100%). CONCLUSIONS Functional assessment of arterial tone by Ea(dyn), measured as the PVV to SVV ratio, predicted arterial pressure response after volume loading in hypotensive, preload-dependent patients under controlled mechanical ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adult triatomines occasionally fly into artificially lit premises in Amazonia. This can result in Trypanosoma cruzi transmission to humans either by direct contact or via foodstuff contamination, but the frequency of such behaviour has not been quantified. To address this issue, a light-trap was set 45 m above ground in primary rainforest near Manaus, state of Amazonas, Brazil and operated monthly for three consecutive nights over the course of one year (432 trap-hours). The most commonly caught reduviids were triatomines, including 38 Panstrongylus geniculatus, nine Panstrongylus lignarius, three Panstrongylus rufotuberculatus, five Rhodnius robustus, two Rhodnius pictipes, one Rhodnius amazonicus and 17 Eratyrus mucronatus. Males were collected more frequently than females. The only month without any catches was May. Attraction of most of the known local T. cruzi vectors to artificial light sources is common and year-round in the Amazon rainforest, implying that they may often invade premises built near forest edges and thus become involved in disease transmission. Consequently, effective Chagas disease prevention in Amazonia will require integrating entomological surveillance with the currently used epidemiological surveillance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyses characteristics of lung injuries produced by alveolar overdistension in three animal species. Mechanical ventilation at normal tidal volume (10 mL/Kg) and high tidal volume (50 mL/Kg) was applied for 30 min in each species. Data were gathered on wet/dry weight ratio, histological score, and area of alveolar collapse. Five out of six rabbits with high tidal volume developed tension pneumothorax, and the rabbit results were therefore not included in the histological analysis. Lungs from the pigs and rats showed minimal histological lesions. Pigs ventilated with high tidal volume had significantly greater oedema, higher neutrophil infiltration, and higher percentage area of alveolar collapse than rats ventilated with high tidal volume. We conclude that rabbits are not an appropriate species for in vivo studies of alveolar overdistension due to their fragility. Although some histological lesions are observed in pigs and rats, the lesions do not appear to be relevant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El proyecto trata de abordar la relación sinérgica actual que mantienen los paramentos verticales con la iluminación y la inclusión de nuevas funciones. La investigación se centra en locales comerciales de planta baja de distintas marcs y productos (tiendas de ropa, restaurantes, peluquerias, etc) que busquen destacarse de sus competidores directos en un gran ciudad, mediante la diferenciación que aporta el diseño interior y la gestión de sus paramentos y la relación de éstos con la iluminación.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La litiasi urinària és un trastorn que implica la formació de precipitats en qualsevol part del tracte urinari. Aquest és un desordre comú que afecta aproximadament a una desena part de la població de la Unió Europea al llarg de la seva vida. A més, durant els cinc anys posteriors a un episodi litiàsic el percentatge de recurrència dels pacients és del 45 al 75%. Aquest trastorn urinari està influït per una gran quantitat de variables, d’origen fisiològic, psicològic i ambiental. Els episodis litiàsics, es poden solucionar espontàniament, amb l’expulsió del càlcul renal, o bé a través de diverses intervencions mèdiques. Els tractaments mèdics derivats de la litiasi urinària; és a dir, la fragmentació del càlcul, intervencions quirúrgiques i tractaments posteriors generen unes grans despeses als sistemes mèdics. Pels motius exposats, la identificació del desordre que ha originat l’episodi litiàsic és de radical importància, per tal de minimitzar el risc de reincidència. Els mètodes més usuals per determinar les causes que desencadenen la formació del càlcul renal són les anàlisis d’orina i l’estudi del càlcul generat. La correcta descripció de la composició i, especialment, l’estructura del càlcul renal pot aportar informació clau sobre les possibles causes de la seva formació, tant de l’inici de nucleació del càlcul com de les successives etapes de creixement cristal·lí. Tenint en compte aquest darrer aspecte, el present estudi s’ha dirigit a la caracterització de càlculs urinaris mitjançant l’aplicació de metodologies d’imatge química (Hyperspectral Imaging), el que va contribuir a determinar les principals característiques espectrals de cada compost majoritari als càlculs renals. D’altra banda, la utilització de mostres de composició coneguda ha possibilitat la creació d’un model amb Xarxes Neuronals Artificials, que permet la classificació de noves mostres de composició desconeguda, de manera més ràpida que el procediment actual. Aquest treball constitueix una nova contribució a la comprensió de l’estructura de les pedres de ronyó, així com les condicions de la seva formació. Els resultats obtinguts destaquen les possibilitats que presenten les tècniques emprades al camp de la litiasi renal, que permeten complementar els coneixements existents enfocats a millorar la qualitat de vida dels pacients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest projecte s’ha centrat en tractar la part de la Visió per Computador que s’encarrega del seguiment d’objectes dins d'una seqüència d’imatges. Concretament, s’ha fet una aproximació al seguiment d’objectes dins d’una escena qualsevol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La finalitat d'aquest projecte és la realització d'un estudi comparatiu de l'algoritme basat en una colònia artificial d'abelles, Artificial Bee Colony (ABC), comparat amb un conjunt d'algoritmes fonamentats en el paradigma de la computació evolutiva. S'utilitzarà l'eficàcia a l'hora d'optimitzar diverses funcions com a mesura comparativa. Els algoritmes amb els quals es comparara l'algoritme ABC són: algoritmes genètics, evolució diferencial i optimització amb eixam de partícules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Desarrollo de un robot seguidor de líneas, en el que se implementan diversas soluciones de las áreas de sistemas embebidos e inteligencia artificial.