987 resultados para 8-74
Resumo:
A characteristic of Parkinson's disease (PD) is the development of tremor within the 4–6 Hz range. One method used to better understand pathological tremor is to compare the responses to tremor-type actions generated intentionally in healthy adults. This study was designed to investigate the similarities and differences between voluntarily generated 4–6 Hz tremor and PD tremor in regards to their amplitude, frequency and coupling characteristics. Tremor responses for 8 PD individuals (on- and off-medication) and 12 healthy adults were assessed under postural and resting conditions. Results showed that the voluntary and PD tremor were essentially identical with regards to the amplitude and peak frequency. However, differences between the groups were found for the variability (SD of peak frequency, proportional power) and regularity (Approximate Entropy, ApEn) of the tremor signal. Additionally, coherence analysis revealed strong inter-limb coupling during voluntary conditions while no bilateral coupling was seen for the PD persons. Overall, healthy participants were able to produce a 5 Hz tremulous motion indistinguishable to that of PD patients in terms of peak frequency and amplitude. However, differences in the structure of variability and level of inter-limb coupling were found for the tremor responses of the PD and healthy adults. These differences were preserved irrespective of the medication state of the PD persons. The results illustrate the importance of assessing the pattern of signal structure/variability to discriminate between different tremor forms, especially where no differences emerge in standard measures of mean amplitude as traditionally defined.
Resumo:
This study examined physiological and performance effects of pre-cooling on medium-fast bowling in the heat. Ten, medium-fast bowlers completed two randomised trials involving either cooling (mixed-methods) or control (no cooling) interventions before a 6-over bowling spell in 31.9±2.1°C and 63.5±9.3% relative humidity. Measures included bowling performance (ball speed, accuracy and run-up speeds), physical characteristics (global positioning system monitoring and counter-movement jump height), physiological (heart rate, core temperature, skin temperature and sweat loss), biochemical (serum concentrations of damage, stress and inflammation) and perceptual variables (perceived exertion and thermal sensation). Mean ball speed (114.5±7.1 vs. 114.1±7.2 km · h−1; P = 0.63; d = 0.09), accuracy (43.1±10.6 vs. 44.2±12.5 AU; P = 0.76; d = 0.14) and total run-up speed (19.1±4.1 vs. 19.3±3.8 km · h−1; P = 0.66; d = 0.06) did not differ between pre-cooling and control respectively; however 20-m sprint speed between overs was 5.9±7.3% greater at Over 4 after pre-cooling (P = 0.03; d = 0.75). Pre-cooling reduced skin temperature after the intervention period (P = 0.006; d = 2.28), core temperature and pre-over heart rates throughout (P = 0.01−0.04; d = 0.96−1.74) and sweat loss by 0.4±0.3 kg (P = 0.01; d = 0.34). Mean rating of perceived exertion and thermal sensation were lower during pre-cooling trials (P = 0.004−0.03; d = 0.77−3.13). Despite no observed improvement in bowling performance, pre-cooling maintained between-over sprint speeds and blunted physiological and perceptual demands to ease the thermoregulatory demands of medium-fast bowling in hot conditions.
Resumo:
Purpose Anecdotal evidence suggests that some sunglass users prefer yellow tints for outdoor activities, such as driving, and research has suggested that such tints improve the apparent contrast and brightness of real-world objects. The aim of this study was to establish whether yellow filters resulted in objective improvements in performance for visual tasks relevant to driving. Methods Response times of nine young (age [mean ± SD], 31.4 ± 6.7 years) and nine older (age, [mean ± SD], 74.6 ± 4.8) adults were measured using video presentations of traffic hazards (driving hazard perception task) and a simple low-contrast grating appeared at random peripheral locations on a computer screen. Response times were compared when participants wore a yellow filter (with and without a linear polarizer) versus a neutral density filter (with and without a linear polarizer). All lens combinations were matched to have similar luminance transmittances (˜27%). Results In the driving hazard perception task, the young but not the older participants responded significantly more rapidly to hazards when wearing a yellow filter than with a luminance-matched neutral density filter (mean difference, 450 milliseconds). In the low-contrast grating task, younger participants also responded more quickly for the yellow filter condition but only when combined with a polarizer. Although response times increased with increasing stimulus eccentricity for the low-contrast grating task, for the younger participants, this slowing of response times with increased eccentricity was reduced in the presence of a yellow filter, indicating that perception of more peripheral objects may be improved by this filter combination. Conclusions Yellow filters improve response times for younger adults for visual tasks relevant to driving.
Resumo:
Brief self-report symptom checklists are often used to screen for postconcussional disorder (PCD) and posttraumatic stress disorder (PTSD) and are highly susceptible to symptom exaggeration. This study examined the utility of the five-item Mild Brain Injury Atypical Symptoms Scale (mBIAS) designed for use with the Neurobehavioral Symptom Inventory (NSI) and the PTSD Checklist–Civilian (PCL–C). Participants were 85 Australian undergraduate students who completed a battery of self-report measures under one of three experimental conditions: control (i.e., honest responding, n = 24), feign PCD (n = 29), and feign PTSD (n = 32). Measures were the mBIAS, NSI, PCL–C, Minnesota Multiphasic Personality Inventory–2, Restructured Form (MMPI–2–RF), and the Structured Inventory of Malingered Symptomatology (SIMS). Participants instructed to feign PTSD and PCD had significantly higher scores on the mBIAS, NSI, PCL–C, and MMPI–2–RF than did controls. Few differences were found between the feign PCD and feign PTSD groups, with the exception of scores on the NSI (feign PCD > feign PTSD) and PCL–C (feign PTSD > feign PCD). Optimal cutoff scores on the mBIAS of ≥8 and ≥6 were found to reflect “probable exaggeration” (sensitivity = .34; specificity = 1.0; positive predictive power, PPP = 1.0; negative predictive power, NPP = .74) and “possible exaggeration” (sensitivity = .72; specificity = .88; PPP = .76; NPP = .85), respectively. Findings provide preliminary support for the use of the mBIAS as a tool to detect symptom exaggeration when administering the NSI and PCL–C.
Resumo:
The assembly of retroviruses such as HIV-1 is driven by oligomerization of their major structural protein, Gag. Gag is a multidomain polyprotein including three conserved folded domains: MA (matrix), CA (capsid) and NC (nucleocapsid)(1). Assembly of an infectious virion proceeds in two stages(2). In the first stage, Gag oligomerization into a hexameric protein lattice leads to the formation of an incomplete, roughly spherical protein shell that buds through the plasma membrane of the infected cell to release an enveloped immature virus particle. In the second stage, cleavage of Gag by the viral protease leads to rearrangement of the particle interior, converting the non-infectious immature virus particle into a mature infectious virion. The immature Gag shell acts as the pivotal intermediate in assembly and is a potential target for anti-retroviral drugs both in inhibiting virus assembly and in disrupting virus maturation(3). However, detailed structural information on the immature Gag shell has not previously been available. For this reason it is unclear what protein conformations and interfaces mediate the interactions between domains and therefore the assembly of retrovirus particles, and what structural transitions are associated with retrovirus maturation. Here we solve the structure of the immature retroviral Gag shell from Mason-Pfizer monkey virus by combining cryo-electron microscopy and tomography. The 8-angstrom resolution structure permits the derivation of a pseudo-atomic model of CA in the immature retrovirus, which defines the protein interfaces mediating retrovirus assembly. We show that transition of an immature retrovirus into its mature infectious form involves marked rotations and translations of CA domains, that the roles of the amino-terminal and carboxy-terminal domains of CA in assembling the immature and mature hexameric lattices are exchanged, and that the CA interactions that stabilize the immature and mature viruses are almost completely distinct.
Resumo:
The project examined the responsiveness of the telenursing service provided by the Child Health Line (hereinafter referred to as CHL). It aimed to provide an account of population usage of the service, the call request types and the response of the service to the calls. In so doing, the project extends the current body of knowledge pertaining to the provision of parenting support through telenursing. Approximately 900 calls to the CHL were audio-recorded over the December 2005-2006 Christmas-New Year period. A protocol was developed to code characteristics of the call, the interactional features between the caller and nurse call-taker, and the extent to which there was (a) agreement on problem definition and the plan of action and (b) interactional alignment between nurse and caller. A quantitative analysis examined the frequencies of the main topics covered in calls to the CHL and any statistical associations between types of calls, length of calls and nurse-caller alignment. In addition, a detailed qualitative analysis was conducted on a subset of calls dealing with the nurse management of calls seeking medical advice and information. Key findings include: • Overall, 74% of the calls discussed parenting and child development issues, 48% discussed health/medical issues, and 16% were information-seeking calls. • More specifically: o 21% discussed health/medical and parenting and child development issues. o 3% discussed parenting and information-seeking issues. o 5% discussed health/medical, parenting/development and information issues. o 18% exclusively focussed on health and medical issues and therefore were outside the remit of the intended scope of the CHL. These calls caused interactional dilemmas for the nurse call-takers as they simultaneously dealt with parental expectations for help and the CHL guidelines indicating that offering medical advice was outside the remit of the service. • Most frequent reasons for calling were to discuss sleep, feeding, normative infant physical functions and parenting advice. • The average length of calls to the CHL was 7 minutes. • Longer calls were more likely to involve nurse call-takers giving advice on more than one topic, the caller displaying strong emotions, the caller not specifically providing the reason for the call, and the caller discussing parenting and developmental issues. • Shorter calls were characterised by the nurse suggesting that the child receive immediate medical attention, the nurse emphasising the importance or urgency of the plan of action, the caller referring to or requesting confirmation of a diagnosis, and caller and nurse call-taker discussion of health and medical issues. • The majority of calls, 92%, achieved parent-nurse alignment by the conclusion of the call. However, 8% did not. • The 8% of calls that were not aligned require further quantitative and qualitative investigation of the interactional features. The findings are pertinent in the current context where Child Health Line now resides within 13HEALTH. These findings indicate: 1. A high demand for parenting advice. 2. Nurse call-takers have a high level of competency in dealing with calls about parenting and normal child development, which is the remit of the CHL. 3. Nurse call-takers and callers achieve a high degree of alignment when both parties agree on a course of action. 4. There is scope for developing professional practice in calls that present difficulties in terms of call content, interactional behaviour and call closure. Recommendations of the project: 1. There are numerous opportunities for further research on interactional aspects of calls to the CHL, such as further investigations of the interactional features and the association of the features to alignment and nonalignment. The rich and detailed insights into the patterns of nurse-parent interactions were afforded by the audio-recording and analysis of calls to the CHL. 2. The regular recording of calls would serve as a way of increasing understanding of the type and nature of calls received, and provide a valuable training resource. Recording and analysing calls to CHL provides insight into the operation of the service, including evidence about the effectiveness of triaging calls. 3. Training in both recognising and dealing with problem calls may be beneficial. For example, calls where the caller showed strong emotion, appeared stressed, frustrated or troubled were less likely to be rated as aligned calls. In calls where the callers described being ‘at their wits end’, or responded to each proposed suggestion with ‘I’ve tried that’, the callers were fairly resistant to advice-giving. 4. Training could focus on strategies for managing calls relating to parenting support and advice, and parental well-being. The project found that these calls were more likely to be rated as being nonaligned. 5. With the implementation of 13HEALTH, future research could compare nurse-parent interaction following the implementation of triaging. Of the calls, 21% had both medical and parenting topics discussed and 5.3% discussed medical, parenting and information topics. Added to this, in 12% of calls, there was ambiguity between the caller and nurse call-taker as to whether the problem was medical or behavioural.
Resumo:
Between 1995 and 2003, 129 cemented primary THRs were performed using full acetabular impaction grafting to reconstruct acetabular deficiencies. These were classified as cavitary in 74 and segmental in 55 hips. Eighty-one patients were reviewed at mean 9.1 (6.2-14.3) years post-operatively. There were seven acetabular component revisions due to aseptic loosening, and a further 11 cases that had migrated >5mm or tilted >5° on radiological review - ten of which reported no symptoms. Kaplan-Meier analysis of revisions for aseptic loosening demonstrates 100% survival at nine years for cavitary defects compared to 82.6% for segmental defects. Our results suggest that the medium-term survival of this technique is excellent when used for purely cavitary defects but less predictable when used with large rim meshes in segmental defects.
Resumo:
In Anderson v Australian Securities and Investments Commission [2012] QCA 301 the Queensland Court of Appeal allowed an appeal from the decision of the primary judge (ASIC v Managed Investments Ltd No 3 [2012] QSC 74. The Court of Appeal was satisfied that the defendants’ non-compliance with the pleading rules in the Uniform Civil Procedure Rules 1999 (Qld) was justified by the claims to privilege against self-incrimination or exposure to a penalty.
Resumo:
Governments regularly publish empirically derived minimum physical activity (PA) guidelines for youth, in response to the ongoing trend of youth physical inactivity. The purpose of this investigation was to explore parents’ awareness of the national PA guidelines for youth, and adolescents’ and their parents’ perceptions of adolescent PA, and compare these to self-reported adolescent PA. A total of 115 adolescents (aged 12-14) and their parents completed questionnaire assessments. Parents responded to questions concerning their awareness of the national PA guidelines, and whether they believed their child to be sufficiently active. Adolescents completed the International Physical Activity Questionnaire for Adolescents, and questions concerning their perceived level of PA. Adolescents were deemed sufficiently active if they participated in an average of at least 60 minutes of moderate-to-vigorous PA each day. Overall, 104 (90.4%) adolescents and their parents had complete data sets and were included in the analysis. Of the 45 (43.3%) sufficiently and 59 (56.7%) insufficiently active adolescents, 42 (93%) and 41 (69.5%) respectively believed that they were active enough for good general health. Additionally, 41 (91.1%) parents of active and 44 (74.6%) parents of inactive adolescents either agreed or strongly agreed that their child participates in sufficient PA for good general health. Twenty-four (53.3%) parents of active adolescents were unaware of the national PA guidelines, with 10 (22.2%) neither aware or unaware, and 11 (24.4%) aware. Similar results were found for the parents of inactive adolescents with 31 (52.5%) unaware, 17 (28.8%) neither aware or unaware, and 11 (18.6%) aware. These results suggest that the youth PA guidelines are being inadequately received by both adolescents, and their parents. Opportunities to effectively communicate these guidelines such as embedment in curriculum for adolescents, or the dissemination of materials for parents, should be maximised by appropriate authorities.
Resumo:
STUDY DESIGN: Reliability and case-control injury study. OBJECTIVES: 1) To determine if a novel device, designed to measure eccentric knee flexors strength via the Nordic hamstring exercise (NHE), displays acceptable test-retest reliability; 2) to determine normative values for eccentric knee flexors strength derived from the device in individuals without a history of hamstring strain injury (HSI) and; 3) to determine if the device could detect weakness in elite athletes with a previous history of unilateral HSI. BACKGROUND: HSIs and reinjuries are the most common cause of lost playing time in a number of sports. Eccentric knee flexors weakness is a major modifiable risk factor for future HSIs, however there is a lack of easily accessible equipment to assess this strength quality. METHODS: Thirty recreationally active males without a history of HSI completed NHEs on the device on 2 separate occasions. Intraclass correlation coefficients (ICCs), typical error (TE), typical error as a co-efficient of variation (%TE), and minimum detectable change at a 95% confidence interval (MDC95) were calculated. Normative strength data were determined using the most reliable measurement. An additional 20 elite athletes with a unilateral history of HSI within the previous 12 months performed NHEs on the device to determine if residual eccentric muscle weakness existed in the previously injured limb. RESULTS: The device displayed high to moderate reliability (ICC = 0.83 to 0.90; TE = 21.7 N to 27.5 N; %TE = 5.8 to 8.5; MDC95 = 76.2 to 60.1 N). Mean±SD normative eccentric flexors strength, based on the uninjured group, was 344.7 ± 61.1 N for the left and 361.2 ± 65.1 N for the right side. The previously injured limbs were 15% weaker than the contralateral uninjured limbs (mean difference = 50.3 N; 95% CI = 25.7 to 74.9N; P < .01), 15% weaker than the normative left limb data (mean difference = 50.0 N; 95% CI = 1.4 to 98.5 N; P = .04) and 18% weaker than the normative right limb data (mean difference = 66.5 N; 95% CI = 18.0 to 115.1 N; P < .01). CONCLUSIONS: The experimental device offers a reliable method to determine eccentric knee flexors strength and strength asymmetry and revealed residual weakness in previously injured elite athletes.
Resumo:
A method for the rapid and simultaneous determination of 6,7-dimethylesculetin (CAS 120-08-1) and geniposide (CAS 24512-63-8) in rat plasma has been developed, using validated high performance liquid chromatography (HPLC) with solid phase extraction (SPE). The HPLC analysis was performed on a commercially available column (200 mm x 4.6 mm, 5 microm) with acetonitrile-methanol-0.1% aqueous formic acid as mobile phase and the UV detection at 343 nm and 238 nm for 6,7-dimethylesculetin and geniposide, respectively. The calibration curves for 6,7-dimethylesculetin and geniposide were linear over the range 0.4-25.6 microg/mL and 1.12-71.68 microg/mL, respectively. The lower limits of quantitation were 0.40 microg/ mL and 1.12 microg/mL, and the lower limits of detection were 0.06 microg/mL and 0.09 microg/ mL, respectively. The intra-day and inter-day precision for 6,7-dimethylesculetin and geniposide were < 5%, whereas the absolute recovery percentages were > 74%. A successful application of the developed HPLC analysis was demonstrated for the pharmacokinetic study of a Traditional Chinese Medicine formula of Yin Chen Hao Tang preparation.