568 resultados para 1259


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate a simple mnemonic rule (the RB-RB/LB-LB rule) for recording intra-oral radiographs with optimal projection for the control of dental implants.Methods: 30 third-year dental students received a short lesson in the RB-RB/LB-LB mnemonic rule. The rule is as follows: if right blur then raise beam (RB-RB), i.e. if implant threads are blurred at the right side of the implant, the X-ray beam direction must be raised towards the ceiling to obtain sharp threads on both implant sides; if left blur then lower beam (LB-LB), i.e. if implant threads are blurred at the left side of the implant, the X-ray beam direction must be lowered towards the floor to obtain sharp threads on both implant sides. Intra-oral radiographs of four screw-type implants placed with different inclination in a Frasaco upper or lower jaw dental model (Frasaco GmbH, Tettnang, Germany) were recorded. The students were unaware of the inclination of the implants and were instructed to re-expose each implant, implementing the mnemonic rule, until an image of the implant with acceptable quality (subjectively judged by the instructor) was obtained. Subsequently, each radiograph was blindly assessed with respect to sharpness of the implant threads and assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable and (4) hopeless.Results: For all implants, from one non-perfect exposure to the following, a higher score was obtained in 64% of the cases, 28% received the same score and 8% obtained a lower score. Only a small variation was observed among exposures of implants with different inclination. on average, two exposures per implant (range: one to eight exposures) were needed to obtain a clinically acceptable image.Conclusion: The RB-RB/LB-LB mnemonic rule for recording intra-oral radiographs of dental implants with a correct projection was easy to implement by inexperienced examiners. Dentomaxillofacial Radiology (2012) 41, 298-304. doi: 10.1259/dmfr/20861598

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to compare two methods for the evaluation of periapical lesion changes following endodontic therapy (digital subtraction technique and morphometric analysis) by outlining the radiolucent area.Methods: 13 human anterior teeth with pulp necrosis and chronic periapical lesions were used. Periapical radiographs were taken immediately after endodontic therapy (0) and then 2 months, 4 months and 6 months post treatment, using an intraoral radiographic film holder stabilized with impression material. The films were processed in a standard manner and the digitized images were submitted to digital subtraction using Adobe Photoshop 6.0. New bone formation or bone resorption areas were then measured. In the morphometric analysis, the periapical lesions were outlined using VixWin 2000 and the area (in square millimetres) was recorded. The obtained data were submitted to agreement analysis for comparison of the two techniques.Results: There was no correlation between the areas of radiographic changes detected by digital subtraction and periapical lesion outline (r=0.02-0.45). The new bone formation areas observed by digital subtraction presented higher values, with bone changes being especially evident in the 2 month follow-up radiographs, which suggests a higher sensitivity for this method.Conclusions: Both methods are suitable for the evaluation of periapical lesion changes, but the digital subtraction technique is more sensitive for detecting radiographic periapical changes. Dentomaxillofacial Radiology (2009) 38, 438-444. doi: 10.1259/dmfr/53304677

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lipases from oilseeds have a great potential for commercial exploration as industrial enzymes. Lipases are used mixed with surfactants in cleaning and other formulated products, and accordingly, both components must be compatible with each other. This work presents the results of the effects of anionic, cationic and nonionic surfactants, polyethylene glycol and urea on the activity and stability of a lipase extracted of oilseeds from Pachira aquatica. The enzyme was purified and the spectrophotometric assays were done using p-nitrophenyl acetate (p-NPA) as substrate pH 7.5 and 25 degrees C. The activity was significantly enhanced by the cationic surfactant CTAB. Bile salts increased the lipase activity in the tested concentration range, whereas anionic and nonionic surfactants showed an inhibitory effect. Aqueous solutions of PEG activated the lipase and maximum activation (161%) occurred in PEG 12,000. This effect on lipase that can be due to exposition of some hydrophobic residues located in the vicinity of the active site or aggregation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of the present study was to describe the clinical and MRI findings of the temporomandibular joint (TMJ) in patients with major depressive disorders (MDDs) of the non-psychotic type.Methods: 40 patients (80 TMJs) who were diagnosed as having MDDs were selected for this study. The clinical examination of the TMJs was conducted according to the research diagnostic criteria and temporomandibular disorders (TMDs). The MRIs were obtained bilaterally in each patient with axial, parasagittal and paracoronal sections within a real-time dynamic sequence. Two trained oral radiologists assessed all images. For statistical analyses, Fisher's exact test and chi(2) test were applied (alpha = 0.05).Results: Migraine was reported in 52.5% of subjects. Considering disc position, statistically significant differences between opening patterns with and without alteration (p = 0.00) and between present and absent joint noises (p = 0.00) were found. Regarding muscular pain, patients with and without abnormalities in disc function and patients with and without abnormalities in disc position were not statistically significant (p = 0.42 and p = 0.40, respectively). Significant differences between mandibular pathway with and without abnormalities (p=0.00) and between present and absent joint noises (p=0.00) were observed.Conclusion: Based on the preliminary results observed by clinical and MRI examination of the TMJ, no direct relationship could be determined between MDDs and TMDs. Dentomaxillofacial Radiology (2012) 41, 316-322. doi: 10.1259/dmfr/27328352

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To compare simulated periodontal bone defect depth measured in digital radiographs with dedicated and non-dedicated software systems and to compare the depth measurements from each program with the measurements in dry mandibles.Methods: Forty periodontal bone defects were created at the proximal area of the first premolar in dry pig mandibles. Measurements of the defects were performed with a periodontal probe in the dry mandible. Periapical digital radiographs of the defects were recorded using the Schick sensor in a standardized exposure setting. All images were read using a Schick dedicated software system (CDR DICOM for Windows v.3.5), and three commonly available non-dedicated software systems (Vix Win 2000 v.1.2; Adobe Photoshop 7.0 and Image Tool 3.0). The defects were measured three times in each image and a consensus was reached among three examiners using the four software systems. The difference between the radiographic measurements was analysed using analysis of variance (ANOVA) and by comparing the measurements from each software system with the dry mandibles measurements using Student's t-test.Results: the mean values of the bone defects measured in the radiographs were 5.07 rum, 5.06 rum, 5.01 mm and 5.11 mm for CDR Digital Image and Communication in Medicine (DICOM) for Windows, Vix Win, Adobe Photoshop, and Image Tool, respectively, and 6.67 mm for the dry mandible. The means of the measurements performed in the four software systems were not significantly different, ANOVA (P = 0.958). A significant underestimation of defect depth was obtained when we compared the mean depths from each software system with the dry mandible measurements (t-test; P congruent to 0.000).Conclusions: the periodontal bone defect measurements in dedicated and in three non-dedicated software systems were not significantly different, but they all underestimated the measurements when compared with the measurements obtained in the dry mandibles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cherubism is a rare hereditary fibro-osseous childhood disease characterized by bone degradation and fibrous tissue replacement at the angles of the mandible and at the tuberosity areas of the maxilla that leads to prominence of the lower face and an appearance reminiscent of the cherub's portrayal in Renaissance art. This disease has an autosomal dominant hereditary characteristic. The purpose of this report is to analyse laboratory tests, clinicopathological and radiographic features of cherubism and its intraoral manifestations in a patient during 4-years of follow-up, correlating the features observed in this case with those of the literature. Also discussed is the atypical and aggressive behaviour of this case during puberty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The formalism of supersymmetric quantum mechanics supplies a trial wave function to be used in the variational method. The screened Coulomb potential is analyzed within this approach. Numerical and exact results for energy eigenvalues are compared.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To verify the behavior of the mineral bone content and density in male adolescents according to age and secondary sexual characters. Methods: 47 healthy adolescents between 10 and 19 years old were assessed according to weight, height, body mass index, puberty stage, calcium intake, bone mineral density and content in the lumbar spine and in the proximal femur. The bone mass was measured through bone densitometries. The intake of calcium was calculated through a 3-day diet. The BMI (body mass index) was calculated with the Quetelet Index and the puberty stage was defined according to Tanner's criteria. The analysis used descriptive statistics such as average and standard deviation, and variance estimates to compare the different age groups. Moreover, the Tukey test was used to determine the significant differences. Results: It was evident that the calcium intake in the different ages assessed has not reached the minimum value of 800 mg. The bone mineral density and content showed an increase after the age of 14, as well as when the teenagers reached the sexual maturation stage G4. The mineralization parameters showed a high level when the teenagers were in the G3 stage, however, without statistical significance. Conclusion: The results indicate an important level of bone mineralization during adolescence. Maturation levels superior to G3 have shown more mineralization. This study proves that the critical years for bone mass gain start after the 14-15 years old or older. Copyright © 2004 by Sociedade Brasileira de Pediatria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. Methods: 257 non-filled approximal surfaces from human permanent premolars and molars were recorded by two intraoral digital receptors, a storage phosphor plate (Digora Optime, Soredex) and a solid-state CMOS sensor (Digora Toto, Soredex), and scanned in a cone beam CT unit (3D Accuitomo FPD80, Morita) with a FOV of 4 cm and a voxel size of 0.08 mm. Image sections were carried out in the axial and mesiodistal tooth planes. Six observers recorded surface cavitation in all images. Validation of the true absence or presence of surface cavitation was performed by inspecting the surfaces under strong light with the naked eye. Differences in sensitivity, specificity and agreement were estimated by analysing the binary data in a generalized linear model using an identity link function. Results: A significantly higher sensitivity was obtained by all observers with CBCT (p,0.001), which was not compromised by a lower specificity. Therefore, a significantly higher overall agreement was obtained with CBCT (p,0.001). There were no significant differences between the Digora Optime phosphor plate system and the Digora Toto CMOS sensor for any parameter. Conclusions: CBCT was much more accurate in the detection of surface cavitation in approximal surfaces than intraoral receptors. The differences are interpreted as clinically significant. A CBCT examination performed for other reasons should also be assessed for approximal surface cavities in teeth without restorations. © 2013 The British Institute of Radiology.