811 resultados para 1180
Resumo:
Purpose: To evaluate the clinical impact of the Varian Exact Couch on dose and volume coverage to targets and critical structures and tumor control probability (TCP) for 6-MV IMRT and Arc Therapy. Methods: Five clinical prostate patients were planned with both, 6-MV 8-field IMRT and 6-MV 2-field RapidArc using the Eclipse treatment planning system (TPS). These plans neglected treatment couch attenuation, as is standard clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the DVHs from each plan iteration. We used a tumor control probability (TCP) model to calculate losses in tumor control resulting from not accounting for the couch top and rails. We also verified dose measurements in a phantom. Results: Failure to account for the treatment couch and rails resulted in clinically unacceptable dose and volume coverage losses to the target for both IMRT and RapidArc. The couch caused average dose losses (relative to plans that ignored the couch) to the prostate of 4.2% and 2.0% for IMRT with the rails out and in, respectively, and 3.2% and 2.9% for RapidArc with the rails out and in, respectively. On average, the percentage of the target covered by the prescribed dose dropped to 35% and 84% for IMRT (rails out and in, respectively) and to 18% and 17% for RapidArc (rails out and in, respectively). The TCP was also reduced by as much as 10.5% (6.3% on average). Dose and volume coverage losses for IMRT plans were primarily due to the rails, while the imaging couch top contributed most to losses for RapidArc. Both the couch top and rails contribute to dose and coverage losses that can render plans clinically unacceptable. A follow-up study we performed found that the less attenuating unipanel mesh couch top available with the Varian Exact couch does not cause a clinically impactful loss of dose or coverage for IMRT but still causes an unacceptable loss for RapidArc. Conclusions: Both the imaging couch top and rails contribute to dose and coverage loss to a degree that, if included, would prevent the plan from meeting clinical planning criteria. Therefore, the imaging and mesh couch tops and rails should be accounted for in Arc Therapy and the imaging couch and rails only in IMRT treatment planning.
Resumo:
This Letter presents a search for new resonances decaying to final states with a vector boson produced in association with a high transverse momentum photon, Vγ, with V=W(→ℓν)or Z(→ℓ+ℓ−), where ℓ =e or μ. The measurements use 20.3fb−1 of proton–proton collision data at a center-of-mass energy of √s=8TeV recorded with the ATLAS detector. No deviations from the Standard Model expectations are found, and production cross section limits are set at 95% confidence level. Masses of the hypothetical aT and ωT states of a benchmark Low Scale Technicolor model are excluded in the ranges [275, 960] GeVand [200, 700] ∪[750, 890] GeV, respectively. Limits at 95% confidence level on the production cross section of a singlet scalar resonance decaying to Zγ final states have also been obtained for masses below 1180 GeV.
Resumo:
The new mineral species vapnikite, Ca3UO6, was found in larnite pyrometamorphic rocks of the Hatrurim Formation at Jabel Harmun in the Judean desert, Palestinian Autonomy, Israel. Vapnikite is an analogue of the synthetic ordered double-perovskite β-Ca3UO6 and is isostructural with the natural fluorperovskite – cryolite Na3AlF6. Vapnikite Ca3UO6 (P21/n,Z = 2, a = 5.739(1), b = 5.951(1), c = 8.312(1) Å, β = 90.4(1)°, V = 283.9(1) Å3) forms yellow-brown xenomorphic grains with a strong vitreous lustre. Small grains up to 20 – 30 m m in size are wedged between larnite, brownmillerite and ye'elimite. Vapnikite has irregular fracture, cleavage and parting were not observed. The calculated density is 5.322 g cm–3, the microhardness is VHN25 = 534 kg mm–2 (mean of seven measurements) corresponding to the hardness of ~5 on the Mohs scale. The crystal structure of vapnikite Ca3UO6 differs from that of its synthetic analogue β-Ca3UO6 by having a larger degree of Ca, U disorder. Vapnikite formed at the high-temperature retrograde stage of pyrometamorphism when larnite rocks were altered by fluids/melts of high alkalinity.
Resumo:
In this article, the realization of a global terrestrial reference system (TRS) based on a consistent combination of Global Navigation Satellite System (GNSS) and Satellite Laser Ranging (SLR) is studied. Our input data consists of normal equation systems from 17 years (1994– 2010) of homogeneously reprocessed GPS, GLONASS and SLR data. This effort used common state of the art reduction models and the same processing software (Bernese GNSS Software) to ensure the highest consistency when combining GNSS and SLR. Residual surface load deformations are modeled with a spherical harmonic approach. The estimated degree-1 surface load coefficients have a strong annual signal for which the GNSS- and SLR-only solutions show very similar results. A combination including these coefficients reduces systematic uncertainties in comparison to the singletechnique solution. In particular, uncertainties due to solar radiation pressure modeling in the coefficient time series can be reduced up to 50 % in the GNSS+SLR solution compared to the GNSS-only solution. In contrast to the ITRF2008 realization, no local ties are used to combine the different geodetic techniques.We combine the pole coordinates as global ties and apply minimum constraints to define the geodetic datum. We show that a common origin, scale and orientation can be reliably realized from our combination strategy in comparison to the ITRF2008.
Resumo:
BACKGROUND: Reduced sensitivity to positive feedback is common in patients with major depressive disorder (MDD). However, findings regarding negative feedback are ambiguous, with both exaggerated and blunted responses being reported. The ventral striatum (VS) plays a major role in processing valenced feedback, and previous imaging studies have shown that the locus of controls (self agency v. external agency) over the outcome influences VS response to feedback. We investigated whether attributing the outcome to one's own action or to an external agent influences feedback processing in patients with MDD. We hypothesized that depressed participants would be less sensitive to the feedback attribution reflected by an altered VS response to self-attributed gains and losses. METHODS: Using functional MRI and a motion prediction task, we investigated the neural responses to self-attributed (SA) and externally attributed (EA) monetary gains and losses in unmedicated patients with MDD and healthy controls. RESULTS: We included 21 patients and 25 controls in our study. Consistent with our prediction, healthy controls showed a VS response influenced by feedback valence and attribution, whereas in depressed patients striatal activity was modulated by valence but was insensitive to attribution. This attribution insensitivity led to an altered ventral putamen response for SA - EA losses in patients with MDD compared with healthy controls. LIMITATIONS: Depressed patients with comorbid anxiety disorder were included. CONCLUSION: These results suggest an altered assignment of motivational salience to SA losses in patients with MDD. Altered striatal response to SA negative events may reinforce the belief of not being in control of negative outcomes contributing to a cycle of learned helplessness.
Resumo:
In this paper, we study the citation decision of a scientific author. By citing a related work, authors can make their arguments more persuasive. We call this the correlation effect. But if authors cite other work, they may give the impression that they think the cited work is more competent than theirs. We call this the reputation effect. These two effects may be the main sources of citation bias. We empirically show that there is a citation bias in Economics by using data from RePEc. We also report how the citation bias differs across regions (U.S., Europe and Asia).
Resumo:
von Ne'man
Resumo:
von Johannes Theis
Resumo:
Aus der Sammlung des Leo Baeck Institute, digitalisiert in Kooperation mit dem Center for Jewish History, NY
Resumo:
Aus der Sammlung des Leo Baeck Institute, digitalisiert in Kooperation mit dem Center for Jewish History, NY
Das Alte Testament im Lichte des alten Orients : Handbuch zur biblisch-orientalischen Altertumskunde
Resumo:
von Alfred Jeremias
Resumo:
von Jakob Horovitz