949 resultados para zinc-ion selective electrode
Resumo:
In this paper, a poly(vinyl chloride) (PVC) membrane electrode is prepared for gemfibrozil, 2, 2-dimethyl-5(2,5-xylyloxy) valeric acid, based on its ion pair complexes with hexadecyltrioctyl ammonium iodide (HTOA). The membrane composition of the electrode was optimized by using the sequential level elimination method for orthogonal experimental design. The electrode has a Nernstian response range from 2.5 X 10(-5) to 0.1 mol/l with an average slope of 55.3 mV/decade. The limit of detection is 7.1 X 10(-6) mol/l. The electrode responses were not affected by pH in the range 10.0-12.3. A Na2B4O7-Na2CO3 buffer of pH = 11.0 was selected as the background electrolyte solution for potentiometric measurements. The electrode was used for determining gemfibrozil in pharmaceutical preparations with satisfactory results.
Resumo:
In this article, we report the rare earth ion selective electrodes developed in our laboratory. Rare earth containing functional copolymers, rare earth oxides, and chelates have been used as active materials. Methods for preparing raw materials, behavior of electrodes, and application of rare earth ion selective electrodes in flow injection analysis have been discussed as well.
Resumo:
The modification of conducting polymer polypyrrole(PPy) on glassy carbon(GC)by electrcchemical technique, and the study on doping effect of Br anion and electrochemical behavior of PPy film electrode were reported.A new kind of Br~- ion selective electrode has been prepared successfully.The mechanism of the electrode potential response is based on the doping effect of anion in the conducting polymer.Effect of polymerization conditions on the potential response characteristic is investigated in dtail.The PPy...
Resumo:
The potentiometric and AC impedance characteristics of all solid-state sodium-selective electrodes based on planar screen-printed Ag/AgCl electrodes are described. Two solid-state designs have been investigated. The first was based on the deposition of a sodium-selective PVC membrane directly on top of a screen-printed Ag/AgCl electrode, The second design included a NaCl doped hydrogel layer, between the PVC and Ag\AgCl layers. The hydrogel provides a mechanism to relieve any blockage to charge transfer occurring when PVC membranes are used directly on top of Ag/AgCl and also improves adhesion between the two layers. Results suggest the electrodes display Fast ion exchange kinetics, low noise and drift. The performance compares favorably to that of a conventional ion-selective electrode with internal filling solution.
Resumo:
A flow injection analysis (FIA) system comprising a cysteine selective electrode as detection system was developed for determination of this amino acid in pharmaceuticals. Several electrodes were constructed for this purpose, having PVC membranes with different ionic exchangers and mediator solvents. Better working characteristics were attained with membranes comprising o-nitrophenyl octyl ether as mediator solvent and a tetraphenylborate based ionic-sensor. Injection of 500 µL standard solutions into an ionic strength adjuster carrier (3x10-3 M) of barium chloride flowing at 2.4mL min-1, showed linearity ranges from 5.0x10-5 to 5.0x10-3 M, with slopes of 76.4±0.6mV decade-1 and R2>0.9935. Slope decreased significantly under the requirement of a pH adjustment, selected at 4.5. Interference of several compounds (sodium, potassium, magnesium, barium, glucose, fructose, and sucrose) was estimated by potentiometric selectivity coefficients and considered negligible. Analysis of real samples were performed and considered accurate, with a relative error to an independent method of +2.7%.
Resumo:
A flow injection analysis (FIA) system having a chlormequat selective electrode is proposed. Several electrodes with poly(vinyl chloride) based membranes were constructed for this purpose. Comparative characterization suggestedthe use of membrane with chlormequat tetraphenylborate and dibutylphthalate. On a single-line FIA set-up, operating with 1x10-2 mol L-1 ionic strength and 6.3 pH, calibration curves presented slopes of 53.6±0.4mV decade-1 within 5.0x10-6 and1.0x10-3 mol L-1, andsquaredcorrelation coefficients >0.9953. The detection limit was 2.2x10-6 mol L-1 and the repeatability equal to ±0.68mV (0.7%). A dual-channel FIA manifold was therefore constructed, enabling automatic attainment of previous ionic strength andpH conditions and thus eliminating sample preparation steps. Slopes of 45.5±0.2mV decade -1 along a concentration range of 8.0x10-6 to 1.0x10-3 mol L-1 with a repeatability ±0.4mV (0.69%) were obtained. Analyses of real samples were performed, and recovery gave results ranging from 96.6 to 101.1%.
Resumo:
new PVC membrane ion selective electrode which is highly selective towards Ni(II) ions was constructed using a Schiff base containing a binaphthyl moiety as the ionophore. The sensor exhibited a good Nernstian response for nickel ions over the concentration range 1.0 × 10–1 – 5.0 × 10–6 M with a lower limit of detection of 1.3 × 10–6 M. It has a fast response time and can be used for a period of 4 months with a good reproducibility. The sensor is suitable for use in aqueous solutions in a wide pH range of 3.6 – 7.4 and works satisfactorily in the presence of 25% (v/v) methanol or ethanol. The sensor shows high selectivity to nickel ions over a wide variety of cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for the direct determination of nickel content in real samples: effluent samples, chocolates and hydrogenated oils.