982 resultados para video-assisted thoracoscopic surgery (VATS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The conservative treatment of acute necrotizing pancreatitis has greatly improved due to broad antibiotic treatment and improved organ support in intensive care units. Nevertheless, infected necrosis or persistent multi-organ dysfunction are predictors of poor outcome. In these patients, there is still a need to perform necrosectomy. Open surgery results in extensive operative trauma and is associated with high morbidity and mortality. Therefore, several minimally invasive techniques have been developed recently. Retroperitoneal necrosectomy has been shown to be safe and to reduce morbidity and mortality compared to the open procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduced in 2008, the femtosecond laser is a promising new technological advance which plays an ever increasing role in cataract surgery where it automates the three main surgical steps: corneal incision, capsulotomy and lens fragmentation. The proven advantages over manual surgery are: a better quality of incision with reduced induced astigmatism; increased reliability and reproducibility of the capsulotomy with increased stability of the implanted lens; a reduction in the use of ultrasound. Regarding refractive results or safety, however, no prospective randomized study to date has shown significant superiority compared with standard manual technique. The significant extra cost generated by this laser, undertaken by the patient, is a limiting factor for both its use and study. This review outlines the potential benefits of femtosecond-laser-assisted cataract surgery due to the automation of key steps and the safety of this new technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Robotic-assisted minimally invasive urologic surgery was developed to minimise surgical trauma resulting in quicker recovery. It has many potential benefits for patients with localised prostate cancer over traditional surgical techniques without taking a risk with the oncological result.

Objectives:
To report the specific surgical outcomes for the first Australian cohort of patients with localised prostate cancer that had undergone robotic-assisted radical prostatectomy (RARP) surgery. The outcomes represent the acute (in-hospital) recovery phase and include pain, length of stay (LOS), urinary catheter management and wound management.

Methods:
Prospective descriptive survey of 214 consecutive patients admitted to a large metropolitan private hospital in Melbourne, Australia between December 2003 and June 2005. Patients had undergone RARP surgery for localised prostate cancer. Data were collected from the medical records and through interview at the time of discharge. Descriptive statistics were used to describe the frequency and proportion of outcomes. Patient characteristics were tabulated using cross tabulation frequency distribution and measures of central tendency.

Results:
The findings from this study are highly encouraging when compared to outcomes associated with traditional surgical techniques. Transurethral catheter duration (median 7 days (IQ range 2)) and LOS (median 3 days (IQ range 2)) were considerably reduced. While operation time (median 3.30 h (IQ range 1.07)) was marginally reduced we would expect a further reduction as the surgical team becomes more skilled.

Conclusion:
The findings from this study contribute to building a comprehensive picture of patient outcomes in the acute (in-hospital) recovery phase for a cohort of Australian patients who have undergone RARP surgery for localised prostate cancer. As such, these findings will provide valuable information with which to plan care for patients’ who undergo robotic-assisted surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: We aimed to evaluate whether the inclusion of videothoracoscopy in a pleural empyema treatment algorithm would change the clinical outcome of such patients. METHODS: This study performed quality-improvement research. We conducted a retrospective review of patients who underwent pleural decortication for pleural empyema at our institution from 2002 to 2008. With the old algorithm (January 2002 to September 2005), open decortication was the procedure of choice, and videothoracoscopy was only performed in certain sporadic mid-stage cases. With the new algorithm (October 2005 to December 2008), videothoracoscopy became the first-line treatment option, whereas open decortication was only performed in patients with a thick pleural peel (>2 cm) observed by chest scan. The patients were divided into an old algorithm (n = 93) and new algorithm (n = 113) group and compared. The main outcome variables assessed included treatment failure (pleural space reintervention or death up to 60 days after medical discharge) and the occurrence of complications. RESULTS: Videothoracoscopy and open decortication were performed in 13 and 80 patients from the old algorithm group and in 81 and 32 patients from the new algorithm group, respectively (p < 0.01). The patients in the new algorithm group were older (41 +/- 1 vs. 46.3 +/- 16.7 years, p=0.014) and had higher Charlson Comorbidity Index scores [0(0-3) vs. 2(0-4), p = 0.032]. The occurrence of treatment failure was similar in both groups (19.35% vs. 24.77%, p= 0.35), although the complication rate was lower in the new algorithm group (48.3% vs. 33.6%, p = 0.04). CONCLUSIONS: The wider use of videothoracoscopy in pleural empyema treatment was associated with fewer complications and unaltered rates of mortality and reoperation even though more severely ill patients were subjected to videothoracoscopic surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oncological liver surgery and interventions aim for removal of tumor tissue while preserving a sufficient amount of functional tissue to ensure organ regeneration. This requires detailed understanding of the patient-specific internal organ anatomy (blood vessel system, bile ducts, tumor location). The introduction of computer support in the surgical process enhances anatomical orientation through patient-specific 3D visualization and enables precise reproduction of planned surgical strategies though stereotactic navigation technology. This article provides clinical background information on indications and techniques for the treatment of liver tumors, reviews the technological contributions addressing the problem of organ motion during navigated surgery on a deforming organ, and finally presents an overview of the clinical experience in computer-assisted liver surgery and interventions. The review concludes that several clinically applicable solutions for computer aided liver surgery are available and small-scale clinical trials have been performed. Further developments will be required more accurate and faster handling of organ deformation and large clinical studies will be required for demonstrating the benefits of computer aided liver surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In rapidly evolving domains such as Computer Assisted Orthopaedic Surgery (CAOS) emphasis is often put first on innovation and new functionality, rather than in developing the common infrastructure needed to support integration and reuse of these innovations. In fact, developing such an infrastructure is often considered to be a high-risk venture given the volatility of such a domain. We present CompAS, a method that exploits the very evolution of innovations in the domain to carry out the necessary quantitative and qualitative commonality and variability analysis, especially in the case of scarce system documentation. We show how our technique applies to the CAOS domain by using conference proceedings as a key source of information about the evolution of features in CAOS systems over a period of several years. We detect and classify evolution patterns to determine functional commonality and variability. We also identify non-functional requirements to help capture domain variability. We have validated our approach by evaluating the degree to which representative test systems can be covered by the common and variable features produced by our analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Durch die von Rapid Prototyping gebotenen Möglichkeiten können computergestützte 3D Operationsplanungen präzise in der Operation umgesetzt werden. An der Universitätsklinik Balgrist wurden in den letzten 3 Jahren nahezu 100 Patienten erfolgreich behandelt, deren Operation in 3D geplant und mit patienten-spezifischen Schablonen umgesetzt wurde. Wir beschreiben die Genauigkeit dieser Methode und berichten über die hierbei gesammelten Erfahrungen. Aufgrund der Flexibilität der Rapid Prototyping Technologie, gibt es nicht immer nur einen Weg wie eine 3D geplante Operation umgesetzt werden kann. Wir zeigen daher anhand von Fallbeispielen unterschiedliche Strategien auf und beschreiben deren Vor- und Nachteile. Ausserdem präsentieren wir die Weiterentwicklung der Methode zur Anwendung an kleinerer Anatomie wie Knochen des Handgelenkes oder der Finger.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduced about two decades ago, computer-assisted orthopedic surgery (CAOS) has emerged as a new and independent area, due to the importance of treatment of musculoskeletal diseases in orthopedics and traumatology, increasing availability of different imaging modalities, and advances in analytics and navigation tools. The aim of this paper is to present the basic elements of CAOS devices and to review state-of-the-art examples of different imaging modalities used to create the virtual representations, of different position tracking devices for navigation systems, of different surgical robots, of different methods for registration and referencing, and of CAOS modules that have been realized for different surgical procedures. Future perspectives will also be outlined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A base do tratamento cirúrgico da Síndrome do Desfiladeiro Torácico (SDT) é a ressecção da primeira costela, podendo associar-se à escalenectomia ou ainda à ressecção de costela cervical. Esta última é feita tradicionalmente por meio de um acesso supraclavicular ou mesmo axilar, o qual é tecnicamente mais trabalhoso. Pode ser realizada também por meio de acesso paraescapular. Embora tecnicamente atrativa e associada à menor invasividade e maior segurança, com ótimo resultado estético, a ressecção da primeira costela torácica, por intermédio de cirurgia videoassistida transaxilar ou pela técnica videotoracoscópica, é pouco relatada na literatura, e nenhuma referência foi encontrada sobre ressecção de costela cervical mediante essa técnica. Neste artigo, apresentamos essa inovação cirúrgica realizada com sucesso para ressecção de costela cervical em duas pacientes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this prospective clinical study was to evaluate the location of paravertebral catheters that were placed using the classical landmark puncture technique and to correlate the distribution of contrast dye injected through the catheters with the extent of somatic block. Paravertebral catheter placement was attempted in 31 patients after video-assisted thoracic surgery. In one patient, an ultrasound-guided approach was chosen after failed catheter placement using the landmark method. A fluoroscopic examination in two planes using contrast dye was followed by injection of local anaesthetic and subsequent clinical testing of the extent of the anaesthetised area. In nine patients (29%), spread of contrast dye was not seen within the paravertebral space as intended. Misplaced catheters were in the epidural space (three patients), in the erector spinae musculature (five patients), and in the pleural space (one patient). There was also a discrepancy between the radiological findings and the observed distribution of loss of sensation. We have demonstrated an unacceptably high misplacement rate of paravertebral catheters using the landmark method. Additional research is required to compare the efficacy and safety of continuous paravertebral block using ultrasound-guided techniques or surgical inserted catheters.