931 resultados para transcranial doppler ultrasound


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Transcranial Doppler (TCD) is widely used to monitor the temporal course of vasospasm after subarachnoid hemorrhage (SAH), but its ability to predict clinical deterioration or infarction from delayed cerebral ischemia (DCI) remains controversial. We sought to determine the prognostic utility of serial TCD examination after SAH. METHODS: We analyzed 1877 TCD examinations in 441 aneurysmal SAH patients within 14 days of onset. The highest mean blood flow velocity (mBFV) value in any vessel before DCI onset was recorded. DCI was defined as clinical deterioration or computed tomographic evidence of infarction caused by vasospasm, with adjudication by consensus of the study team. Logistic regression was used to calculate adjusted odds ratios for DCI risk after controlling for other risk factors. RESULTS: DCI occurred in 21% of patients (n = 92). Multivariate predictors of DCI included modified Fisher computed tomographic score (P = 0.001), poor clinical grade (P = 0.04), and female sex (P = 0.008). After controlling for these variables, all TCD mBFV thresholds between 120 and 180 cm/s added a modest degree of incremental predictive value for DCI at nearly all time points, with maximal sensitivity by SAH day 8. However, the sensitivity of any mBFV more than 120 cm/s for subsequent DCI was only 63%, with a positive predictive value of 22% among patients with Hunt and Hess grades I to III and 36% in patients with Hunt and Hess grades IV and V. Positive predictive value was only slightly higher if mBFV exceeded 180 cm/s. CONCLUSION: Increased TCD flow velocities imply only a mild incremental risk of DCI after SAH, with maximal sensitivity by day 8. Nearly 40% of patients with DCI never attained an mBFV more than 120 cm/s during the course of monitoring. Given the poor overall sensitivity of TCD, improved methods for identifying patients at high risk for DCI after SAH are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Ultrasound Doppler is a new technology that has recently been used in large animal reproduction. As the conventional ultrasound (B-mode) it is a noninvasive technique, but with the advantage of allows the assessment of the hemodynamic of reproductive tract in real time. The observation of important features of the vascularization and changes that occur during physiological processes that were not previously seen on B-mode encourage a reassessment of the concepts already established on the events of the reproductive physiology of animals and their applications. Review: In attempt to re-understand the equine reproductive physiology and finding practical uses to this new technique, authors showed that, during the follicular deviation, features are observed by Doppler before being observed under B-mode ultrasound like changes in the speed of the blood flow two days before deviation of the follicle size and one day before the increase in blood flow area of the follicular wall. According to another study ovulation is characterized by a decreased blood flow of the follicular wall in the last four hours preceding it, as well as the serration of the granulosa layer and formation of a non vascularized apex, but in our ongoing study, the ability to decrease the vascularity was not found. Very vascularized follicles are associated with higher rates of oocyte maturation and pregnant that does less vascularized follicles in the preovulatory phase. Those follicles that have septated evacuation (or prolonged) showed more vascularization and serration of the granulosa one hour before ovulation than follicles that ovulate normally, and this vascularization includes the apex of the follicle, the follicular wall portion that is not vascularized in normal ovulation. Another study reported that hemorrhagic follicles have better vascularization of the follicular wall on the days preceding ovulation than follicles destined to ovulate. Some authors also showed that anovulatory follicles grow in size at the same rate as ovulatory follicles, but the percentage of vascularization of its wall is much smaller at 35 mm. Another study characterized that the vascular wall of the follicle that results in the first ovulation of the year is much smaller on the day before ovulation than the number of vessels present in a follicle that will ovulate in the middle of the breeding season. In these cases, the use of Doppler ultrasound can help to prevent economic losses as insemination of mares in cycles that are not able of resulting in pregnancy. This review aims to gather the information found in the literature about the characteristics of follicular hemodynamic of mares taking into account moments of deviation in follicle size, ovulation, ovulation failure and follicular viability. Conclusion: The Doppler technology has the potential to provide important information about the follicular environment and thus be used in practice in search of the perfect equine reproductive management, achieving better utilization of genetic material and increasing the financial return. The use of this new tool opens a large area for several interesting studies that will contribute to the knowledge of the physiological events of the mare for that this technique can soon be effectively applied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultrasound (B-mode) was used to analyze follicular events in 12 trained female owl monkeys (Aotus azarai infulatus). The animals were examined every 48 hours for over 90days to measure and map follicular growth in both ovaries and to measure (using Doppler velocimetry) local hemodynamic changes during the peri-ovulatory stage. There were 44 follicular growth events, each with two or three follicular waves, and a mean ± SEM interval between events of 17 ± 1.13 days. There were various hemodynamic changes during follicular growth; both vascular resistance index and pulsatility index decreased during the time when the follicle diameter peaked. Thus, both B-mode and Doppler ultrasound were useful for monitoring ovarian follicular events in owl monkeys. © 2013 Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Doppler ultrasound enables the assessment of blood flow in real time and has been widely used to aid in pregnancy diagnosis and monitoring in dogs and cats. This technique has a diferencial when compared with the B-mode ultrasound, as it allows the evaluation of vascular hemodynamic characteristics, while the two-dimensional ultrasound allows the diagnosis of pregnancy and fetal viability. Thus, the objective of this review is to describe how circulation is characterized in the uterine and fetal arteries in bitches during pregnancy using Doppler ultrasonography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are no studies investigating the effect of the contrast infusion on the sensitivity and specificity of the main Doppler criteria of renal artery stenosis (RAS). Our aim was to evaluate the accuracy of these Doppler criteria prior to and following the intravenous administration of perfluorocarbon exposed sonicated albumin (PESDA) in patients suspected of having RAS. Thirty consecutive hypertensive patients (13 males, mean age of 57 ± 10 years) suspected of having RAS by clinical clues, were submitted to ultrasonography (US) of renal arteries before and after enhancement using continuous infusion of PESDA. All patients underwent angiography, and haemodynamically significant RAS was considered when ≥50%. At angiography, it was detected RAS ≥50% in 18 patients, 5 with bilateral stenosis. After contrast, the examination time was slightly reduced by approximately 20%. In non-enhanced US the sensitivity was better when based on resistance index (82.9%) while the specificity was better when based on renal aortic ratio (89.2%). The predictive positive value was stable for all indexes (74.0%–88.0%) while negative predictive value was low (44%–51%). The specificity and positive predictive value based on renal aortic ratio increased after PESDA injection respectively, from 89 to 97.3% and from 88 to 95%. In hypertensives suspected to have RAS the sensitivity and specificity of Duplex US is dependent of the criterion evaluated. Enhancement with continuous infusion of PESDA improves only the specificity based on renal aortic ratio but do not modify the sensitivity of any index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to analyse the cerebral venous outflow in relation to the arterial inflow during a Valsalva manoeuvre (VM). In 19 healthy volunteers (mean age 24.1 +/- 2.6 years), the middle cerebral artery (MCA) and the straight sinus (SRS) were insonated by transcranial Doppler sonography. Simultaneously the arterial blood pressure was recorded using a photoplethysmographic method. Two VM of 10 s length were performed per participant. Tracings of the variables were then transformed to equidistantly re-sampled data. Phases of the VM were analysed regarding the increase of the flow velocities and the latency to the peak. The typical four phases of the VM were also found in the SRS signal. The relative flow velocity (FV) increase was significantly higher in the SRS than in the MCA for all phases, particularly that of phase IV (p < 0.01). Comparison of the time latency of the VM phases of the MCA and SRS only showed a significant difference for phase I (p < 0.01). In particular, there was no significant difference for phase IV (15.8 +/- 0.29 vs. 16.0 +/- 0.28 s). Alterations in venous outflow in phase I are best explained by a cross-sectional change of the lumen of the SRS, while phases II and III are compatible with a Starling resistor. However, the significantly lager venous than the arterial overshoot in phase IV may be explained by the active regulation of the venous tone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) is an alternative to surgery for high-risk patients with severe aortic valve stenosis. Periprocedural stroke is reported at an incidence up to 10%. Magnetic resonance imaging studies have identified new onset of clinically silent ischaemic cerebral lesions more frequently (68-84%). So far, few data are available about cerebral embolism during TAVI. The aim of this study was to determine the frequency of high-intensity transient signals (HITS) and to explore differences in the HITS pattern between transfemoral and transapical access and between self-expanding (SE) and balloon-expandable (BE) deployment technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

the aim of this study was to investigate specific activation patterns and potential gender differences during mental rotation and to investigate whether functional magnetic resonance imaging (fMRI) and functional transcranial Doppler sonography (fTCD) lateralize hemispheric dominance concordantly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (p< or =0.002). At the dose of 2.4 ml of SonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (p<0.01) increased the accuracy, sensitivity and specificity of assessment of disease compared with baseline ultrasound. SonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Intermittent (IT) and continuous (CT) thermodilution and esophageal Doppler (ED), are all used for hemodynamic monitoring. The aim of this study was to test the agreement between these methods during endotoxin (ET) and dobutamine infusion. METHODS: Twenty-two pigs (39 +/- 1.8 kg body weight) were randomized to general anesthesia and either continuous ET (n = 9) or placebo (PL, n = 13) infusion. After 18 hours of ET or PL infusion, the animals were further randomized to receive dobutamine (n = 3 in ET, n = 5 in PL) or PL. A set of measurements using the three methods were obtained every hour, and the relative blood flow changes between two subsequent measurements were calculated. RESULTS: Bias or limits of agreement for flows were 0.73 L/min or 1.80 L/min for IT and CT, -0.33 L/min or 4.29 L/min for IT and ED, and -1.06 or 3.94 for CT and ED (n = 515, each). For flow changes they were 1% or 44%, 2% or 59%, and 3% or 45%, respectively. Bias and limits of agreement did not differ in ET- and PL-treated animals or in animals with or without dobutamine. Despite significant correlation between any two methods, the respective correlation coefficients (r) were small (IT vs. CT: 0.452; IT vs. ED: 0.042; CT vs. ED: 0.069; all p < 0.001). The same directional changes were measured by any two methods in 49%, 40%, and 50%. When IT flows >5 L/min were compared with IT flows 5 L/min.