959 resultados para total hip prosthesis
Resumo:
The aim of this investigation was to assess the diagnostic accuracy of intraoperative cultures for the early identification of patients who are at risk of infection after primary total hip arthroplasty. Four or six swabs were obtained immediately before the wound closure in 263 primary total hip replacements. Patients with a maximum of one positive culture were denoted as patients with a normal profile and did not receive any treatment. Patients with two or more positive cultures, with the same organism identified, were denoted as patients with a risk profile and received treatment with a specific antibiotic as determined by the antibiogram for six weeks. The follow-up ranged from a minimum of one year to five years and eleven months, concentrating on the presence or absence of infection, which was defined as discharge of pus through the surgical wound or as a fistula at any time after surgery. The accuracy of this procedure ( number of cases correctly identified in relation to the total number of cases) in the group of 152 arthroplasties in which 4 swabs per patient were collected was 96%. In the group of 111 arthroplasties in which 6 swabs per patient were collected the accuracy was 95.5%. We conclude that the collection of swabs under the conditions described is a method of high accuracy ( above 95%) for the evaluation of risk of infection after primary total hip arthroplasty.
Resumo:
The occurrence of audible squeaking in some patients with ceramic-on-ceramic (CoC) hip prostheses is a cause for concern. Considering multifactor contributing to this phenomenon, many studies have been conducted over the last decade. Great efforts have been put on understanding the mechanics of the hip squeaking to gain a deep insight into factors resulting in sound emission from hip articulation. Disruption of fluid-film lubrication and friction were reported as main potential causes of hip squeaking, while patient and surgical factors as well as design and material of hip implants were identified as affecting factors. This review article therefore summarised the recent available literature on this subject to provide a platform for future developments. Moreover, high wear rates and ceramic liner fracture as viable consequences of hip squeaking were discussed.
Resumo:
Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.
Resumo:
We describe the use of cable fixation and acute total hip replacement for acetabular fracture in the elderly. 12 patients with acetabular fractures, having a mean age of 79 (65-93) years, were treated with cable fixation and acute total hip arthroplasty. 8 were T-shaped fractures and 4 associated fractures of the posterior column and posterior wall. 1 patient died 5 months after surgery and the remaining 11 were followed for 2 years. All patients had a good clinical outcome. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This surgical technique provides good primary fixation, stabilizes complex acetabular fractures in elderly patients with osteoporotic bone and permits early postoperative mobilization.
Resumo:
BACKGROUND: Medialization of the cup with a respective increase in femoral offset has been proposed in THA to increase abductor moment arms. Insofar as there are potential disadvantages to cup medialization, it is important to ascertain whether the purported biomechanical benefits of cup medialization are large enough to warrant the downsides; to date, studies regarding this question have disagreed. QUESTIONS/PURPOSES: The purpose of this study was to quantify the effect of cup medialization with a compensatory increase in femoral offset compared with anatomic reconstruction for patients undergoing THA. We tested the hypothesis that there is a (linear) correlation between preoperative anatomic parameters and muscle moment arm increase caused by cup medialization. METHODS: Fifteen patients undergoing THA were selected, covering a typical range of preoperative femoral offsets. For each patient, a finite element model was built based on a preoperative CT scan. The model included the pelvis, femur, gluteus minimus, medius, and maximus. Two reconstructions were compared: (1) anatomic position of the acetabular center of rotation, and (2) cup medialization compensated by an increase in the femoral offset. Passive abduction-adduction and flexion-extension were simulated in the range of normal gait. Muscle moment arms were evaluated and correlated to preoperative femoral offset, acetabular offset, height of the greater trochanter (relative to femoral center of rotation), and femoral antetorsion angle. RESULTS: The increase of muscle moment arms caused by cup medialization varied among patients. Muscle moment arms increase by 10% to 85% of the amount of cup medialization for abduction-adduction and from -35% (decrease) to 50% for flexion-extension. The change in moment arm was inversely correlated (R(2) = 0.588, p = 0.001) to femoral antetorsion (anteversion), such that patients with less femoral antetorsion gained more in terms of hip muscle moments. No linear correlation was observed between changes in moment arm and other preoperative parameters in this series. CONCLUSIONS: The benefit of cup medialization is variable and depends on the individual anatomy. CLINICAL RELEVANCE: Cup medialization with compensatory increase of the femoral offset may be particularly effective in patients with less femoral antetorsion. However, cup medialization must be balanced against its tradeoffs, including the additional loss of medial acetabular bone stock, and eventual proprioceptive implications of the nonanatomic center of rotation and perhaps joint reaction forces. Clinical studies should better determine the relevance of small changes of moment arms on function and joint reaction forces.
Resumo:
Background: The type of anesthesia to be used for total hip arthroplasty (THA) is still a matter of debate. We compared the occurrence of per- and post-anesthesia incidents in patients receiving either general (GA) or regional anesthesia (RA). Methods: We used data from 29 hospitals, routinely collected in the Anaesthesia Databank Switzerland register between January 2001 and December 2003. We used multi-level logistic regression models. Results: There were more per- and post-anesthesia incidents under GA compared to RA (35.1% vs 32.7 %, n = 3191, and 23.1% vs 19.4%, n = 3258, respectively). In multi-level logistic regression analysis, RA was significantly associated with a lower incidence of per-anesthetic problems, especially hypertension, compared with GA. During the post-anesthetic period, RA was also less associated with pain. Conversely, RA was more associated with post-anesthetic hypotension, especially for epidural technique. In addition, age and ASA were more associated with incidents under GA compared to RA. Men were more associated with per-anesthetic problems under RA compared to GA. Whereas increased age (>67), gender (male), and ASA were linked with the choice of RA, we noticed that this choice depended also on hospital practices after we adjusted for the other variables. Conclusions: Compared to RA, GA was associated with an increased proportion of per- and post-anesthesia incidents. Although this study is only observational, it is rooted in daily practice. Whereas RA might be routinely proposed, GA might be indicated because of contraindications to RA, patients' preferences or other surgical or anaesthesiology related reasons. Finally, the choice of a type of anesthesia seems to depend on local practices that may differ between hospitals.
Resumo:
Background: The type of anesthesia to be used for total hip arthroplasty (THA) is still a matter of debate. We compared the occurrence of per- and post-anesthesia incidents in patients receiving either general (GA) or regional anesthesia (RA). Methods: We used data from 29 hospitals, routinely collected in the Anaesthesia Databank Switzerland register between January 2001 and December 2003. We used multi-level logistic regression models. Results: There were more per- and post-anesthesia incidents under GA compared to RA (35.1% vs 32.7 %, n = 3191, and 23.1% vs 19.4%, n = 3258, respectively). In multi-level logistic regression analysis, RA was significantly associated with a lower incidence of per-anesthetic problems, especially hypertension, compared with GA. During the post-anesthetic period, RA was also less associated with pain. Conversely, RA was more associated with post-anesthetic hypotension, especially for epidural technique. In addition, age and ASA were more associated with incidents under GA compared to RA. Men were more associated with per-anesthetic problems under RA compared to GA. Whereas increased age (>67), gender (male), and ASA were linked with the choice of RA, we noticed that this choice depended also on hospital practices after we adjusted for the other variables. Conclusions: Compared to RA, GA was associated with an increased proportion of per- and post-anesthesia incidents. Although this study is only observational, it is rooted in daily practice. Whereas RA might be routinely proposed, GA might be indicated because of contraindications to RA, patients' preferences or other surgical or anaesthesiology related reasons. Finally, the choice of a type of anesthesia seems to depend on local practices that may differ between hospitals.
Resumo:
Infection of total hip arthroplasties (THA) leads to significant long-termmorbidity and high healthcare costs. We evaluated the differentreasons for treatment failure using different surgical modalities in a12-year prosthetic joint infection cohort study.Method: All patients hospitalized at our institution with infected THAwere included either retrospectively (1999-2007) or prospectively(2008-2010). THA infection was defined as growth of the same microorganismin ≥2 tissue or synovial fluid culture, visible purulence, sinustract or acute inflammation on tissue histopathology. Outcome analysiswas performed at outpatient visits, followed by contacting patients,their relatives and/or treating physicians afterwards.Results: During the study period, 117 patients with THA were identified.We exclude 2 patients due to missing data. The median age was69 years (range, 33-102 years); 42% were women. THA was mainlyperformed for osteoarthritis (n = 84), followed by trauma (n = 22),necrosis (n = 4), dysplasia (n = 2), rheumatoid arthritis (n = 1), osteosarcoma(n = 1) and tuberculosis (n = 1). 28 infections occurred early(≤3 months), 25 delayed (3-24 months) and 63 late (≥24 months aftersurgery). Infected THA were treated with (i) two-stage exchange in59 patients (51%, cure rate: 93%), (ii) one-stage exchange in 5 (4.3%,cure rate: 100%), (iii) debridement with change of mobile parts in18 (17%, cure rate: 83%), (iv) debridement without change of mobileparts in 17 (14%, cure rate: 53% ), (v) Girdlestone in 13 (11%, curerate: 100%), and (vi) two-stage exchange followed by removal in 3(2.6%). Patients were followed for a mean of 3.9 years (range, 0.1 to 9years), 7 patients died unrelated to the infected THA. 15 patients (13%)needed additional operations, 1 for mechanical reasons (dislocationof spacer) and 14 for persistent infection: 11 treated with debridementand retention (8 without change and 3 with change of mobile parts)and 3 with two-stage exchange. The mean number of surgery was 2.2(range, 1 to 5). The infection was finally eradicated in all patients, butthe functional outcome remained unsatisfactory in 20% (persistentpain or impaired mobility due to spacer or Girdlestone situation).Conclusions: Non-respect of current treatment concept leads totreatment failure with subsequent operations. Precise analysis of eachtreatment failures can be used for improving the treatment algorithmleading to better results.
Resumo:
Potilaiden käsitys terveyteen liittyvästä elämänlaadusta lonkan tekonivelleikkauksen jälkeisenä toipumisaikana – kuuden kuukauden seurantatutkimus Tässä kaksivaiheisessa seurantatutkimuksessa tarkasteltiin potilaiden käsitystä terveyteen liittyvästä elämänlaadusta lonkan tekonivelleikkauksen jälkeisenä toipumisaikana. Tutkimuksen ensimmäisessä vaiheessa tarkoituksena oli sekä kuvailla potilaiden kokemuksia potilaana olosta, saamastaan hoidosta ja terveyspalveluorganisaatiosta että analysoida aikaisempien tutkimusten perusteella leikkauksen tuloksia potilaan kannalta. Toisessa vaiheessa tarkoituksena oli arvioida potilaiden kokemaa elämänlaatua leikkauksen jälkeen, ja sitä vaikuttivatko primaaritulokset (fyysinen toimintakyky, kipu, ahdistus) tai taloudelliset seuraukset (potilaiden itsensämaksamat kustannukset, palvelujen käyttö) terveyteen liittyvään elämänlaatuun. Tutkimuksen tavoitteena oli löytää mahdolliset kriittiset ajankohdat tai tekijät, jotka saattavat hidastaa toipumista ja siten huonontaa potilaiden elämänlaatua. Tätä tietoa voidaan käyttää hoitotyössä kun suunnitellaan sopivaa hoitoa ja tukea toipumisajalle. Tutkimuksen ensimmäisessä vaiheessa primaarileikkaukseen tulevat potilaat (n = 17) kuvailivat teemahaastatteluissa kokemuksiaan kahdesti leikkauksen jälkeen. Haastatteluaineisto analysoitiin induktiivisella sisällönanalyysilla. Lisäksi 17 tutkimusartikkelista analysoitiin deduktiivisella sisällönanalyysilla leikkauksen tuloksia potilaalle, tuloksiin vaikuttavia tekijöitä ja käytetyt tutkimusmetodit. Toisessa vaiheessa primaari- tai revisioleikkaukseen tulevat potilaat (n = 100) arvioivat leikkauksen tuloksia kuuden kuukauden ajan leikkauksen jälkeen: terveyteen liittyvää elämänlaatua, primaarituloksia ja taloudellisia seurauksia. Aineisto kerättiin erilaisilla mittareilla: Sickness Impact Profile, Finnish Version, Stait-Trait Anxiety Inventory, ja Numeric Rating Scale. Lisäksi käytettiin tätä tutkimusta varten tehtyjä kyselylomakkeita: Fyysinen toimintakyky-mittari, Palvelujen käyttö-mittari ja Kustannusmittari. Tutkimuksen toiseen vaiheen tulokset analysoitiin tilastollisilla menetelmillä. Potilaiden terveyteen liittyvä elämänlaatu parani ja kipu lievittyi leikkauksen jälkeen ja fyysinen toimintakyky lisääntyi toipumisaikana. Positiivisista muutoksista huolimatta potilaat kokivat ahdistusta samassa määrin kuin ennen leikkaustakin. Palvelujen käyttö vaihteli toipumisajan kuluessa ja potilaiden maksamissa kustannuksissa oli suuria vaihteluita. Fyysisen toimintakyvyn lisääntyminen ja kivun lieveneminen paransivat terveyteen liittyvää elämänlaatua. Sen sijaan huonompi elämänlaatu toipumisaikana oli yhteydessä suurempaan palvelujen käyttöön, kun taas kustannuksilla ei ollut yhteyttä elämänlaatuun. Potilaiden ominaispiirteet tulisi ottaa enemmän huomioon suunniteltaessa sopivaa leikkauksenjälkeistä hoitoa ja tukea. Potilaat tarvitsevat yksilöllisiä ohjeita, sillä monet taustatekijät (esim. ikä, sukupuoli, preoperatiivinen kipu, siviilisääty, ja leikkaustyyppi) vaikuttavat toipumiseen.
Resumo:
INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.
Resumo:
This prospective study addresses early results of the treatment of acute acetabular fractures in elderly patients by total hip arthroplasty and cerclage wiring.Fifteen patients with an average age of 81 years were treated at our institution between February 1998 and December 2000. There were two transverse fractures, eight T-shaped fractures, two transverse fractures with associated posterior wall fracture, two posterior column fractures with associated posterior wall fracture, and one fracture of both columns. Treatment consisted of cerclage wiring of the fracture and primary non-cemented total hip replacement.All of the patients were followed for a mean of 36 months. Although there was one patient with three hip dislocations during the first 10 months after the operation, we found an excellent or good result for the entire group. During this relatively short follow-up period, we have not found a radiological loss of fracture reduction of more than 1 mm or a cup migration of more than 3.2 mm. All of the fractures healed and no loosening of the implant was evident.Primary total hip arthroplasty combined with internal fixation is a valid treatment option for acetabular fractures in the elderly. Preliminary results are convincing, but a bigger patient population and a longer follow-up time are necessary before we are able to draw final conclusions.
Resumo:
In a prospective study, total hip arthroplasty (THA) patients were assessed preoperatively and postoperatively (n = 95) to determine if tender points (TPs) are associated with poor THA outcomes. Patients with high follow-up TP counts had higher visual analog scale (VAS) for pain and sleep, higher follow-up Western Ontario and McMaster Universities Arthritis Index (pain, stiffness, function), lower Health Assessment Questionnaire, Harris Hip, and Short Form 36 (physical functioning, bodily pain, physical component summary) scores. High follow-up TP were associated with increased pain, pain not relieved by surgery, poor function, and poor sleep. Visual analog scale pain and sleep, Short Form 36 (physical functioning, bodily pain), Western Ontario and McMaster Universities Arthritis Index, Health Assessment Questionnaire, and Harris hip scores improved significantly after THA; TP scores did not. Higher preoperative TP were predictive of higher follow-up TP but were poorly predictive of poor outcome measures after surgery in individual patients, suggesting that preoperative TPs are contraindicative for THA.
Resumo:
Total hip replacement has seen a tremendous development and has become one of the most successful surgical interventions in orthopaedics. While during the first decades of development of total hip arthroplasty the fixation of the implant into the bone was the main concern, the focus has shifted towards surgical technique and soft tissue handling. In order to avoid permanent soft tissue damage, muscular dysfunction and concerns in regards to cosmetics, minimal invasive and anatomic approaches have been developed. We here provide a short overview on various methods of total hip replacements and we describe our technique through a minimal invasive direct anterior approach. While muscle and nerve damage is minimal, this technique allows for a rapid rehabilitation and is associated with an excellent functional outcome and a minimal risk for dislocation.