900 resultados para the scanning reference electrode technique


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the 1980s the development of the doubly labelled water (DLW) technique made it possible to determine the validity of dietary assessment methods using external, independent markers of intake in free-living populations. Since then, the accuracy of self-reported energy intake (EI) has been questioned on a number of occasions as under-reporting has been found to be prevalent in many different populations. This paper is a review of investigations using the DLW technique in conjunction with self-reported EI measures in groups including adults, children and adolescents, obese persons, athletes, military personnel and trekking explorers. In studies where a person other than the subject is responsible for recording dietary intake, such as parents of young children, EI generally corresponds to DLW determined energy expenditure. However, in instances where the subjects themselves report their intake, EI is generally under-reported when compared with energy expenditure. It was originally believed that this phenomenon of under-reporting was linked to increased adiposity and body size, however, it is now apparent that other factors, such as dietary restraint and socio-economic status, are also involved. This paper therefore aims to present a more comprehensive picture of under-reporting by tying in the findings of many DLW studies with other studies focusing particularly on the characteristics and mechanisms for under-reporting. Awareness of these characteristics and mechanisms will enable researchers to obtain more accurate self-reports of EI using all dietary recording techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of gate-to-drain capacitance (C-gd) measurement as a tool to characterize hot-carrier-induced charge centers in submicron n- and p-MOSFET's has been reviewed and demonstrated. By analyzing the change in C-gd measured at room and cryogenic temperature before and after high gate-to-drain transverse field (high field) and maximum substrate current (I-bmax) stress, it is concluded that the degradation was found to be mostly due to trapping of majority carriers and generation of interface states. These interface states were found to be acceptor states at top half of band gap for n-MOSFETs and donor states at bottom half of band gap for p-MOSFETs. In general, hot electrons are more likely to be trapped in gate oxide as compared to hot holes while the presence of hot holes generates more interface states. Also, we have demonstrated a new method for extracting the spatial distribution of oxide trapped charge, Q(ot), through gate-to-substrate capacitance (C-gb) measurement. This method is simple to implement and does not require additional information from simulation or detailed knowledge of the device's structure. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A two-dimensional numerical simulation model of interface states in scanning capacitance microscopy (SCM) measurements of p-n junctions is presented-In the model, amphoteric interface states with two transition energies in the Si band gap are represented as fixed charges to account for their behavior in SCM measurements. The interface states are shown to cause a stretch-out-and a parallel shift of the capacitance-voltage characteristics in the depletion. and neutral regions of p-n junctions, respectively. This explains the discrepancy between - the SCM measurement and simulation near p-n junctions, and thus modeling interface states is crucial for SCM dopant profiling of p-n junctions. (C) 2002 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to determine the pharmacokinetics of [C-14]diclofenac, [C-14]salicylate and [H-3]clonidine using a single pass rat head perfusion preparation. The head was perfused with 3-[N-morpholino] propane-sulfonic acid-buffered Ringer's solution. Tc-99m-red blood cells and a drug were injected in a bolus into the internal carotid artery and collected from the posterior facial vein over 28 min. A two-barrier stochastic organ model was used to estimate the statistical moments of the solutes. Plasma, interstitial and cellular distribution volumes for the solutes ranged from 1.0 mL (diclofenac) to 1.6 mL (salicylate), 2.0 mL (diclofenac) to 4.2 mL (water) and 3.9 mL (salicylate) to 20.9 mL (diclofenac), respectively. A comparison of these volumes to water indicated some exclusion of the drugs from the interstitial space and salicylate from the cellular space. Permeability-surface area (PS) products calculated from plasma to interstitial fluid permeation clearances (CLPI) (range 0.02-0.40 mL s(-1)) and fractions of solute unbound in the perfusate were in the order: diclofenac>salicylate >clonidine>sucrose (from 41.8 to 0.10 mL s(-1)). The slow efflux of diclofenac, compared with clonidine and salicylate, may be related to its low average unbound fraction in the cells. This work accounts for the tail of disposition curves in describing pharmacokinetics in the head.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The formalin-Tween sedimentation method was compared with the formalin-ether sedimentation for parasitic detection. Of a total 297 fecal specimens examined, 72.1% were positive. The formalin-tween technique was effective for ascertaining helminths, particularly Ascaris lumbricoides, Trichuris trichiura and hookworm eggs; however it has less capability for protozoa detection. This method is simple, inexpensive, less time consuming and highly sensitive when detecting the parasitic infection, particularly when focusing on helminth eggs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Campylobacter was isolated in 178 out of 622 stool samples (200 porcine, 220 bovine, and 202 canine). From these 178 samples, the microorganism was identified in 64 samples (36%) isolated only in Butzler selective medium (BSM), 34 samples (19%) using filtration technique (FT), and in 80 samples (45%) using both BSM and FT. Comparison of the proportion of positivity using both techniques showed a significant value (c2 = 9,184; p > 0.001); BSM (36%) being more efficient than FT (19%). The use of both techniques yielded the highest isolation positivity (45%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: An animal model has been developed to compare the effects of suture technique on the luminal dimensions and compliance of end-to-side vascular anastomoses. METHODS: Carotid and internal mammalian arteries (IMAs) were exposed in three pigs (90 kg). IMAs were sectioned distally to perform end-to-side anastomoses on carotid arteries. One anastomosis was performed with 7/0 polypropylene running suture. The other was performed with the automated suture delivery device (Perclose/Abbott Labs Inc.) that makes a 7/0 polypropylene interrupted suture. Four piezoelectric crystals were sutured on toe, heel and both lateral sides of each anastomosis to measure anastomotic axes. Anastomotic cross-sectional area (CSAA) was calculated with: CSAA = pi x mM/4 where m and M are the minor and major axes of the elliptical anastomosis. Cross-sectional anastomotic compliance (CSAC) was calculated as CSAC=Delta CSAA/Delta P where Delta P is the mean pulse pressure and Delta CSAA is the mean CSAA during cardiac cycle. RESULTS: We collected a total of 1200000 pressure-length data per animal. For running suture we had a mean systolic CSAA of 26.94+/-0.4 mm(2) and a mean CSAA in diastole of 26.30+/-0.5 mm(2) (mean Delta CSAA was 0.64 mm(2)). CSAC for running suture was 4.5 x 10(-6)m(2)/kPa. For interrupted suture we had a mean CSAA in systole of 21.98+/-0.2 mm(2) and a mean CSAA in diastole of 17.38+/-0.3 mm(2) (mean Delta CSAA was 4.6+/-0.1 mm(2)). CSAC for interrupted suture was 11 x 10(-6) m(2)/kPa. CONCLUSIONS: This model, even with some limitations, can be a reliable source of information improving the outcome of vascular anastomoses. The study demonstrates that suture technique has a substantial effect on cross-sectional anastomotic compliance of end-to-side anastomoses. Interrupted suture may maximise the anastomotic lumen and provides a considerably higher CSAC than continuous suture, that reduces flow turbulence, shear stress and intimal hyperplasia. The Heartflo anastomosis device is a reliable instrument that facilitates performance of interrupted suture anastomoses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is controversy over the use of the Ross procedure with regard to the sub-coronary and root replacement technique and its long-term durability. A systematic review of the literature may provide insight into the outcomes of these two surgical subvariants. A systematic review of reports between 1967 and February 2013 on sub-coronary and root replacement Ross procedures was undertaken. Twenty-four articles were included and divided into (i) sub-coronary technique and (ii) root replacement technique. The 10-year survival rate for a mixed-patient population in the sub-coronary procedure was 87.3% with a 95% confidence interval (CI) of 79.7-93.4 and 89.1% (95% CI, 85.3-92.1) in the root replacement technique category. For adults, it was 94 vs 95.3% (CI, 88.9-98.1) and in the paediatric series it was 90 vs 92.7% (CI, 86.9-96.0), respectively. Freedom from reoperation at 10 years was, in the mixed population, 83.3% (95% CI, 69.9-93.4) and 93.3% (95% CI, 89.4-95.9) for sub-coronary versus root replacement technique, respectively. In adults, it was 98 vs 91.2% (95% CI, 82.4-295.8), and in the paediatric series 93.3 vs 92.0% (95% CI, 86.1-96.5) for sub-coronary versus root replacement technique, respectively. The Ross procedure arguably has satisfactory results over 5 and 10 years for both adults and children. The results do not support the advantages of the sub-coronary technique over the root replacement technique. Root replacement was of benefit to patients undergoing reoperations on neoaorta and for long-term survival in mixed series.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Selostus: Mahdollisuus lyhytaikaisen virtsankeruun käyttöön lypsylehmien virtsan pseudouridiinin erityksen määrittämisessä

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: A straightforward original Chimney Graft (CG) protocol has been developed at our institution in selected cases of juxtarenal aortic aneurysm (JRAA). The aim of this study was to present our clinical experience of consecutive series with use of uncovered self-expanding stent (SES) as "Open Chimney" (OCh) in the endovascular repair (EVAR) of JRAA. METHODS: A standard endograft with suprarenal fixation struts is delivered with its proximal covered edge just below the highest RA in JRAA presenting the ostium of the two renal arteries at a different aortic level and the distance between the highest renal artery and the beginning of the aneurysm (improved landing zone) ≥10 mm. The low-lying renal artery is maintained patent by the OCh graft (standard SES) delivered from left brachial access (6 Fr). All clinical, anatomical, and operative data were prospectively collected and retrieved for the study analysis. RESULTS: From July 2010 to November 2012, OCh EVAR was offered to 22 consecutive patients considered unfit for JRAA open repair. All procedures were technically successful with aneurysm exclusion and patent OCh graft. One small perioperative type Ia endoleak spontaneously disappeared at the 3-month CT control. One patient died because of acute decompensated heart failure. One patient presented a left hemispheric stroke. The median follow-up of 18 months (range 7-35) showed aneurysm exclusion in all patients without type I and III endoleaks, SES stenosis, and/or renal impairment. CONCLUSIONS: OCh-EVAR is a straightforward technique that can be employed in selected cases of JRAA, avoiding the more complex and expensive fenestrated EVAR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultrasound-guided core-needle biopsy has high sensitivity in the diagnosis of breast cancer. The present study is aimed at detailing the main steps of such procedure, including indications, advantages, limitations, follow-up and description of the technique, besides presenting a checklist including the critical steps required for an appropriate practice of the technique. In the recent years, an increasing number of patients have required breast biopsy, indicating the necessity of a proportional increase in the number of skilled professionals to carry out the procedures and histological diagnoses. A multidisciplinary approach involving the tripod clinical practice-radiology-pathology is responsible for the highest rate of accuracy of the technique and must always be adopted.