950 resultados para synsedimentary faults
Resumo:
The Quaternary Active Faults Database of Iberia (QAFI) is an initiative lead by the Institute of Geology and Mines of Spain (IGME) for building a public repository of scientific data regarding faults having documented activity during the last 2.59 Ma (Quaternary). QAFI also addresses a need to transfer geologic knowledge to practitioners of seismic hazard and risk in Iberia by identifying and characterizing seismogenic fault-sources. QAFI is populated by the information freely provided by more than 40 Earth science researchers, storing to date a total of 262 records. In this article we describe the development and evolution of the database, as well as its internal architecture. Aditionally, a first global analysis of the data is provided with a special focus on length and slip-rate fault parameters. Finally, the database completeness and the internal consistency of the data are discussed. Even though QAFI v.2.0 is the most current resource for calculating fault-related seismic hazard in Iberia, the database is still incomplete and requires further review.
Resumo:
Late Variscan volcanic activity is documented in the Late Carboniferous Salvan-Dorenaz sedimentary basin and in the neighboring basement units of the Aiguilles-Rouges and Mont-Blanc crystalline massifs (Western Alps). Precise U/Pb isotopic dating, zircon morphology and geochemical analyses indicate that volcanism occurred during short-lived pulses and that coexisting crustal and mantle sources were involved in the production of melts. Volcanic and subvolcanic products were emplaced along major N-S to NNE-SSW transtensional fracture zones, similar to the ones that governed intense basement exhumation and that favored the formation and filling of the Late Carboniferous Salvan-Dorenaz continental basin. In the Aiguilles-Rouges massif, dacitic flows outcropping at the base of the Salvan-Dorenaz basin erupted at 308 +/- 3 Ma; they represent the surface equivalent of the nearby Vallorcine peraluminous granite and associated rhyolitic dykes (311 +/- 17 Ma). In the Mont Blanc massif, calc-alkaline rhyolitic dykes were emplaced simultaneously (307 +/- 2 Ma) at shallow crustal levels, but they derive from deeper magma sources denoting enhanced mantellic activity. Recently identified tuffs and volcaniclastic layers embedded at different levels of the Salvan-Dorenaz stratigraphic record testify a 295 +3/-4 Ma old episode of highly explosive volcanism from distant volcanic centers, possibly located in the Aar-Gotthard massifs (Central Alps). Their zircon typology is highly heterogeneous. documenting wall-rock contamination of the melts and/or admixture of crustal sediments, whereas consistent subpopulations point to high-temperature magmas of deep-seated origin and alkaline affinity. The dated volcanic layers from the Salvan-Dorenaz basin set the beginning of the detrital sedimentation at 308 +/- 3 Ma and constrain the deposition of 1.5-1.7 km thick of elastic sediments within a time span of 10-15 Ma. These results infer minimum, long-term subsidence rates during basin evolution in the order of >0.1 mm/a, while in the surrounding basement units estimated exhumation rates are in the range of 1 mm/a. All dated rocks contain inherited zircon populations about 350, 450 or 600 Ma old.
Resumo:
The northwestern margin of the Valencia trough is an area of low strain characterized by slow normal faults and low to moderate seismicity. Since the mid 1990s this area has been the subject of a number of studies on active tectonic which have proposed different approaches to the location of active faults and to the calculation of the parameters that describe their seismic cycle. Fifty-six active faults have been found and a classification has been made in accordance with their characteristics: a) faults with clear evidence of large paleo-, historic or instrumental earthquakes (2/56); b) faults with evidence of accumulated activity during the Plio-Quaternary and with associated instrumental seismicity (7/56); c) faults with evidence of accumulated activity during the Plio-Quaternary and without associated instrumental seismicity (17/56); d) faults with associated instrumental seismicity and without evidence of accumulated activity during the Plio-Quaternary (30/56), and e) faults without evidence of activity or inactive faults. The parameters that describe the seismic cycle of these faults have been evaluated by different methods that use the geological data obtained for each fault except when paleoseismological studies were available. This classification can be applied to other areas with low slip faults because of the simplicity of the approaches adopted. This study reviews the different approaches proposed and describes the active faults located, highlighting the need a) to better understand active faults in slow strain zones through paleoseismological studies, and b) to include them in seismic hazard studies.
Resumo:
Power line modelling has become an interesting research area in recent years as a result of advances in the power line distribution network system. Extensive knowledge about the power line cable characteristics can be implemented in a software algorithm in a modern broadband power-line communication modem. In this study, a novel approach for modelling power line cables (AMCMK) based on the broadband impedance spectroscopy (BIS) and transmission line matrix (TLM) techniques is recommended in characterizing a healthy cable and the various faults associated with low-voltage cables for both open and short circuit situation. Models for different cable conditions are developed and tuned, which include six models for both healthy and faulty cables situations. The models are on the basis of impedance response analysis of the cable. The resulting spectra from the simulations are also cross-correlated to determine the degree of similarities between the healthy cable spectra and their respective faulty spectra.
Resumo:
Na sequência da integração da energia eólica em larga escala foram estabelecidos códigos de rede pelos vários operadores de sistema, exigindo que os parques eólicos permaneçam em serviço durante e após a ocorrência de defeitos na rede a montante. Nos parques eólicos equipados com sistemas de velocidade constante este requisito pode ser assegurado pela instalação, no ponto de interligação à rede, de equipamento de compensação dinâmica de potência reactiva, controlado como fonte de tensão, sendo as funções de controlo baseadas em medidas efectuadas no ponto de interligação relativamente às componentes directas da tensão e da corrente. Como a adopção deste tipo de soluções externas é adequada ao funcionamento do sistema em regime equilibrado, este artigo foca a avaliação do desempenho da solução no caso da ocorrência de defeitos assimétricos. Os resultados obtidos através das simulações dinâmicas evidenciam o aparecimento de sobre tensões nas fases não afectadas pelo defeito que poderão colocar o parque eólico fora de serviço.
Resumo:
In high speed manufacturing systems, continuous operation is desirable, with minimal disruption for repairs and service. An intelligent diagnostic monitoring system, designed to detect developing faults before catastrophic failure, or prior to undesirable reduction in output quality, is a good means of achieving this. Artificial neural networks have already been found to be of value in fault diagnosis of machinery. The aim here is to provide a system capable of detecting a number of faults, in order that maintenance can be scheduled in advance of sudden failure, and to reduce the necessity to replace parts at intervals based on mean time between failures. Instead, parts will need to be replaced only when necessary. Analysis of control information in the form of position error data from two servomotors is described.
Resumo:
A discrete-element model of sea ice is used to study how a 90° change in wind direction alters the pattern of faults generated through mechanical failure of the ice. The sea-ice domain is 400km in size and consists of polygonal floes obtained through a Voronoi tessellation. Initially the floes are frozen together through viscous–elastic joints that can break under sufficient compressive, tensile and shear deformation. A constant wind-stress gradient is applied until the initially frozen ice pack is broken into roughly diamond-shaped aggregates, with crack angles determined by wing-crack formation. Then partial refreezing of the cracks delineating the aggregates is modelled through reduction of their length by a particular fraction, the ice pack deformation is neglected and the wind stress is rotated by 90°. New cracks form, delineating aggregates with a different orientation. Our results show the new crack orientation depends on the refrozen fraction of the initial faults: as this fraction increases, the new cracks gradually rotate to the new wind direction, reaching 90° for fully refrozen faults. Such reorientation is determined by a competition between new cracks forming at a preferential angle determined by the wing-crack theory and at old cracks oriented at a less favourable angle but having higher stresses due to shorter contacts across the joints
Resumo:
A technique to calculate the current waveform for both close-up and remote short-circuit faults on DC supplied railways and subways is presented. Exact DC short-circuit current calculation is best performed by sophisticated computer transient simulations. However, an accurate simplified calculation method based on second-order approximation which can be easily executed with the help of a calculator or a spreadsheet program is proposed.
Resumo:
The distribution of short-circuit current is investigated by means of two methods, one direct and the other analytic; both methods consider uniform probability distribution of line faults. In the direct method, the procedure consists of calculating fault currents at equidistant points along the line, starting from one of the end points and considering the other end open. The magnitude of the current is classified according to Brazilian standards (regulation NBR-7118). The analytic method assumes that the distribution of short-circuit currents through the busbar and the distribution of the line length connected to it are known, as well as the independence of values. The method is designed to determine the probability that fault currents through a line will surpass the pre-established magnitude, thus generating frequency distribution curves of short-circuit currents along the lines.
Resumo:
In some applications like fault analysis, fault location, power quality studies, safety analysis, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of particular interest. In order to investigate effects of neutrals and system grounding on the operation of the distribution feeders with faults, in this research a hybrid short circuit algorithm is generalized. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. Results obtained from several case studies using IEEE 34-node test network are presented and discussed.