937 resultados para shear strengthening


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Shear strengthening is required when an RC beam is found deficient in shear, or when its shear capacity falls below its flexural capacity after flexural strengthening. A recent technique for the shear strengthening of RC beams is to provide additional FRP web reinforcement, commonly in the form of bonded external FRP strips/sheets. Over the last few years, several experimental studies have been conducted on this new strengthening technique, which has established its effectiveness. While experimental methods of investigation are extremely useful in obtaining information about the composite behaviour of FRP and reinforced concrete, the use of numerical models such as the one presented in this paper helps in developing a good understanding of the behaviour at lower costs. In the study presented in this paper, ANSYS finite element program is used to examine the response of beams strengthened in shear by FRPs. The FE model is calibrated against test results performed at the University of Kentucky. Once validated, the model is used to examine the influence of fibre orientation, compressive strength of concrete, area of tensile and compressive reinforcements, and amount and distance between stirrups on the strength and ductility of FRP strengthened beam.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Determination of shear strength of brick-mortar bed joint is critical to overcome the sliding-shear or joint-shear failure in masonry. In the recent past, researchers have attempted to enhance the shear strength and deformation capacity of brick-mortar bed joints by gluing fiber-reinforced polymer (FRP) composite across the bed joint. FRP composites offer several advantages like high strength-to-weight ratio, and ease of application in terms of labor, time, and reduced curing period. Furthermore, FRP composites are desirable for strengthening old masonry buildings having heritage value because of its minimal interference with the existing architecture. A majority of earlier studies on shear strengthening of masonry available in the literature adopted masonry having the ratio of modulus of elasticity of masonry unit (Emu) to modulus of elasticity of mortar (Em) greater than one. Information related to shear behavior of FRP glued masonry composed of masonry units having Young's modulus lower than mortar is limited. Hence the present study is focused on characterizing the interfacial behavior of brick-mortar bed joint of masonry assemblages composed of solid burnt clay bricks and cement-sand mortar (E-mu/E-m ratio less than one), strengthened with FRP composites. Masonry triplets and prisms with bed joint inclined to loading axis (0 degrees, 30 degrees, 45 degrees, 60 degrees and 90 degrees) are employed in this study. Glass and carbon FRP composites composed of bidirectional FRP fabric with equal density in both directions are used for strengthening masonry. Masonry triplets are glued with glass and carbon FRP composites in two configurations: (1) both faces of the triplet specimens are fully glued with GFRP composites; and (2) both faces of the triplet specimens are glued with GFRP and CFRP composites in strip form. The performance of masonry assemblages strengthened with FRP composites is assessed in terms of gain in shear strength, shear displacement, and postpeak behavior for various configurations and types of FRP composites considered. A semianalytical model is proposed for the prediction of shear strength of masonry bed joints glued with FRP composites. A composite failure envelope consisting of a Coulomb friction model and a compression cap is obtained for unreinforced masonry and GFRP-strengthened masonry based on the test results of masonry triplets and masonry prisms with bed joints having various inclinations to the loading (C) 2015 American Society of Civil Engineers.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study investigates the structural behavior of precracked reinforced concrete (RC) T-beams strengthened in shear with externally bonded carbon fiber-reinforced polymer (CFRP) sheets. It reports on seven tests on unstrengthened and strengthened RC T-beams, identifying the influence of load history, beam depth, and percentage of longitudinal steel reinforcement on the structural behavior. The experimental results indicate that the contributions of the external CFRP sheets to the shear force capacity can be significant and depend on most of the investigated variables. This study also investigates the accuracy of the prediction of the fiber-reinforced polymer (FRP) contribution in ACI 440.2R-08, UK Concrete Society TR55, and fib Bulletin 14 design guidelines for shear strengthening. A comparison of predicted values with experimental results indicates that the guidelines can overestimate the shear contribution of the externally bonded FRP system. © 2012, American Concrete Institute.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

RC beams shear strengthened with externally bonded fiber-reinforced polymer (FRP) U strips or side strips usually fail owing to debonding of the bonded FRP shear reinforcement. Because such debonding usually occurs in a brittle manner at relatively small shear crack widths, some of the internal steel stirrups intersected by the critical shear crack may not have reached yielding at beam shear failure. Consequently, the yield stress of internal steel stirrups in such a strengthened RC beam cannot be fully utilized. This adverse shear interaction between the internal steel shear reinforcement and the external FRP shear reinforcement may significantly reduce the benefit of the shear strengthening FRP but has not been considered explicitly by any of the shear strength models in the existing design guidelines. This paper presents a new shear strength model considering this adverse shear interaction through the introduction of a shear interaction factor. A comprehensive evaluation of the proposed model, as well as three other shear strength models, is conducted using a large test database. It is shown that the proposed shear strength model performs the best among the models compared, and the performance of the other shear strength models can be significantly improved by including the proposed shear interaction factor. Finally, a design recommendation is presented.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

RC beams shear-strengthened with externally-bonded FRP side strips or U-strips usually fail by debonding. As such debonding occurs in a brittle manner at relatively small shear crack widths, some of the internal steel stirrups may not have reached yielding at beam shear failure. Consequently, the internal steel stirrups cannot be fully utilized. This adverse shear interaction between internal steel stirrups and external FRP strips may significantly reduce the benefit of shear-strengthening FRP but has not been considered by any of the existing FRP strengthening design guidelines. In this paper, an improved shear strength model capable of accounting for the effect of the above shear interaction is first presented, in which the unfavorable effect of shear interaction is reflected through a reduction factor (i.e. shear interaction factor). Using a large test database established in the present study, the performance of the proposed model as well as that of three other shear strength models is then assessed. This assessment shows that the proposed shear strength model performs better than the three existing models. The assessment also shows that the inclusion of the proposed shear interaction factor in the existing models can significantly improve their performance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of fiber-reinforced polymer (FRP) shear strengthening systems for the strength enhancement of existing reinforced concrete structures is discussed. An experimental and analytical research programme is under way to investigate the performance of bonded passive and unbonded prestressed FRP shear systems, and to quantify the effect of the load history on the strengthed behavior. Non-linear finite-element analysis are being developed to model the strengthed behavior. The results will provide insight into the optimum system parameters and contribute to the formulation of design guidance for advanced FRP strengthing strategies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study investigates the effect of thermal cycling on the performance of concrete beams retrofitted with CARDIFRC, a new class of high performance fiber-reinforced cement-based material that is compatible with concrete. Twenty four beams were subjected to 24 h thermal cycles between 25 and 90°C. One third of the beams were reinforced either in flexure only or in flexure and shear with conventional steel reinforcement and used as control specimens. The remaining sixteen beams were retrofitted with CARDIFRC strips to provide external flexural and/or shear strengthening. All beams were exposed to a varied number of 24 h thermal cycles ranging from 0 to 90 and were tested in four-point bending at room temperature. The tests indicated that the retrofitted members were stronger and stiffer than control beams, and more importantly, that their failure initiated in flexure without any signs of interfacial delamination cracking. The results of these tests are presented and compared to analytical predictions. The predictions show good correlation with the experimental results. © 2010 ASCE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study, 21 small beam specimens with a pre-set through-crack were tested with FRP strips bonded to the sides to study the bond behavior between shear-strengthening FRP and concrete (referred to as "the interface" for simplicity hereafter). The test parameters included the bond length, width, thickness of FRP strip and the angle between fiber orientation and crack opening direction (referred to as "fiber tensile angle" θ hereafter) on the bond behavior of the interface. Test results showed that: 1) the small beam test setup with a pre-set crack is suitable for studying the bond behavior between FRP and concrete; 2) the bond length, width, and thickness of the FRP as well as the fiber angle have significant effects on the bond strength; 3) the distribution of FRP strains along the direction perpendicular to the fiber orientation (FRP width direction) is non-uniform; this is mainly attributed to the progressive debonding of the FRP strips in the width direction, with the FRP at the location of larger crack width debonding earlier.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In the last decade the near-surface mounted (NSM) strengthening technique using carbon fibre reinforced polymers (CFRP) has been increasingly used to improve the load carrying capacity of concrete members. Compared to externally bonded reinforcement (EBR), the NSM system presents considerable advantages. This technique consists in the insertion of carbon fibre reinforced polymer laminate strips into pre-cut slits opened in the concrete cover of the elements to be strengthened. CFRP reinforcement is bonded to concrete with an appropriate groove filler, typically epoxy adhesive or cement grout. Up to now, research efforts have been mainly focused on several structural aspects, such as: bond behaviour, flexural and/or shear strengthening effectiveness, and energy dissipation capacity of beam-column joints. In such research works, as well as in field applications, the most widespread adhesives that are used to bond reinforcements to concrete are epoxy resins. It is largely accepted that the performance of the whole application of NSM systems strongly depends on the mechanical properties of the epoxy resins, for which proper curing conditions must be assured. Therefore, the existence of non-destructive methods that allow monitoring the curing process of epoxy resins in the NSM CFRP system is desirable, in view of obtaining continuous information that can provide indication in regard to the effectiveness of curing and the expectable bond behaviour of CFRP/adhesive/concrete systems. The experimental research was developed at the Laboratory of the Structural Division of the Civil Engineering Department of the University of Minho in Guimar\~aes, Portugal (LEST). The main objective was to develop and propose a new method for continuous quality control of the curing of epoxy resins applied in NSM CFRP strengthening systems. This objective is pursued through the adaptation of an existing technique, termed EMM-ARM (Elasticity Modulus Monitoring through Ambient Response Method) that has been developed for monitoring the early stiffness evolution of cement-based materials. The experimental program was composed of two parts: (i) direct pull-out tests on concrete specimens strengthened with NSM CFRP laminate strips were conducted to assess the evolution of bond behaviour between CFRP and concrete since early ages; and, (ii) EMM-ARM tests were carried out for monitoring the progressive stiffness development of the structural adhesive used in CFRP applications. In order to verify the capability of the proposed method for evaluating the elastic modulus of the epoxy, static E-Modulus was determined through tension tests. The results of the two series of tests were then combined and compared to evaluate the possibility of implementation of a new method for the continuous monitoring and quality control of NSM CFRP applications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Los polímeros armados con fibras (FRP) se utilizan en refuerzos de estructuras de hormigón debido sobre todo a sus excelentes propiedades mecánicas, su resistencia a la corrosión y a su ligereza que se traduce en facilidad y ahorro en el transporte, puesta en obra y aplicación, la cual se realiza de forma muy rápida, con pocos operarios y utilizando medios auxiliares ligeros, minimizándose las interrupciones del uso de la estructura y las molestias a los usuarios. Las razones presentadas anteriormente, han despertado un gran inter´es por parte de diferentes grupos de investigación a nivel mundial y que actualmente se encuentran desarrollando nuevas técnicas de aplicación y métodos de cálculo. Sin embargo, las investigaciones realizadas hasta la fecha, muestran un procedimiento bien definido y aceptado en lo referente al cálculo a flexión, lo cual no ocurre con el refuerzo a cortante y aunque se ha demostrado que el refuerzo con FRP es un sistema eficaz para incrementar la capacidad ´ultima frente a esfuerzos cortantes, también se pone de manifiesto la necesidad de más estudios experimentales y teóricos para avanzar en el entendimiento de los mecanismos involucrados para este tipo de refuerzo y establecer un procedimiento de diseño apropiado que maximice las excelentes propiedades de este material. Los modelos que explican el comportamiento del refuerzo a cortante de elementos de hormigón armado son complejos y sin transposición directa a fórmulas ingenieriles. Las normas actualmente en vigor, generalmente, establecen empíricamente la capacidad cortante como la suma de las capacidades del hormigón y el refuerzo transversal de acero. Cuando un elemento es reforzado externamente con FRP, los modelos son evidentemente aun más complejos. Las guías y recomendaciones existentes proponen calcular la capacidad del elemento añadiendo la resistencia aportada por el refuerzo externo de FRP a la ya dada por el hormigón y acero transversal. Sin embargo, la idoneidad de este acercamiento es cuestionable puesto que no tiene en cuenta una posible interacción entre refuerzos. Con base en lo anterior se da origen al tema objeto de este trabajo, el cual está orientado al estudio a cortante de elementos de hormigón armado (HA), reforzados externamente con material compuesto de tejido unidireccional de fibra de carbono y resina epoxi. Inicialmente se hace una completa revisión del estado actual del conocimiento de la resistencia a cortante en elementos de hormigón armado con y sin refuerzo externo de FRP, prestando especial atención en los mecanismos actuantes estudiados hasta la fecha. La bibliografía consultada ha sido exhaustiva y actualizada lo que ha permitido el estudio de los modelos propuestos más importantes, tanto para la descripción del fenómeno de adherencia entre hormigón-FRP como de la valoración del aporte al cortante total hecho por el FRP, a través de sendas bases de datos de ensayos de pull-out y de vigas de hormigón armado ensayadas a cortante. Con base en todo lo anterior, se expusieron los mecanismos actuantes en el aporte a cortante hecho por el FRP en elementos de hormigón armado y la forma como las principales guías de cálculo existentes hasta la fecha los abordan. De igual forma se define un modelo de resistencia de esfuerzos para el FRP y se proponen dos modelos para el cálculo de las tensiones o deformaciones efectivas, de los cuales uno esta basado en el modelo de adherencia propuesto por Oller (2005) y el otro en una regresión multivariante para los mecanismos expuestos. Como complemento del estudio de los trabajos encontrados en la literatura, se lleva acabo un programa experimental que, además de aportar más registros a la exigua base de datos existentes, aporte mayor luz a los puntos que se consideran están deficientemente resueltos. Dentro de este programa se realizaron 32 ensayos sobre 16 vigas de 4.5 m de longitud (dos ensayos por viga), reforzadas a cortante con tejido unidireccional de CFRP. Finalmente, estos estudios han permitido proponer modificaciones a las formulaciones existentes en los códigos y guías en vigor. Abstract Its excellent mechanical properties, as well as its corrosion resistance and light weight, which make it easy to apply and inexpensive to ship to the worksite, are the basis of the extended use of fiber reinforced polymer (FRP) as external strengthening for structures. FRP strengthening is a rapid operation calling for only limited labor and lightweight ancillary equipment, all of which minimizes both the interruption of facility usage and user inconvenience. These advantages have aroused considerable interest in civil engineering science and technology and have led to countless applications the world over. Research studies on the shear strength of FRP-strengthened members have been much fewer in number and more controversial than the research on flexural strengthening, for which a more or less standardized and generally accepted procedure has been established. The research conducted and a host of applications around the world have shown that FRP strengthening is an effective technique for raising ultimate shear strength, but it has also revealed a need for further experimental and theoretical research to advance in the understanding of the mechanisms involved and establish suitable design procedures that optimize the excellent properties of this material The models that explain reinforced concrete (RC) shear strength behavior are complex and cannot be directly transposed to engineering formulas. The standards presently in place generally establish shear capacity empirically as the sum of the capacities of the concrete and the passive reinforcement. When members are externally strengthened with FRP, the models are obviously even more complex. The existing guides and recommendations propose calculating capacity by adding the external strength provided by the FRP to the contributions of the concrete and passive reinforcement. The suitability of this approach is questionable, however, because it fails to consider the interaction between passive reinforcement and external strengthening. The subject of this work is based in above, which is focused on externally shear strengthening for reinforced concrete members with unidirectional carbon fiber sheets bonded with epoxy resin. v Initially a thorough literature review on shear of reinforced concrete beams with and without external FRP strengthening was performed, paying special attention to the acting mechanisms studied to date, which allowed the study of the most important models both to describe the bond phenomenon as well as calculating the FRP shear contribution, through separate databases of pull-out tests and shear tests on reinforced concrete beams externally strengthened with FRP. Based on above, they were exposed the acting mechanisms in a FRP shear strengthening on reinforced concrete beams and how guidelines deal the topic. The same way, it is defined a FRP stress strength model and two more models are proposed for calculating the effective stress, one of these is based on the Oller (2005) bond model and another one is the data best fit, taking into account most of the acting mechanisms. To complement the theoretical part we develop an experimental program that, in addition to providing more records to the meager existing database provide greater understanding to the points considered poorly resolved. The test program included 32 tests of 16 beams (2 per beam) of 4.5 m long, shear strengthened with FRP, externally. Finally, modifications to the existing codes and guidelines are proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A worldwide interest is being generated in the use of fibre reinforced polymer composites (FRP) in rehabilitation of reinforced concrete structures. As a replacement for the traditional steel plates or external post-tensioning in strengthening applications, various types of FRP plates, with their high strength to weight ratio and good resistance to corrosion, represent a class of ideal material in external retrofitting. Within the last ten years, many design guidelines have been published to provide guidance for the selection, design and installation of FRP systems for external strengthening of concrete structures. Use of these guidelines requires understanding of a number of issues pertaining to different properties and structural failure modes specific to these materials. A research initiative funded by the CRC for Construction Innovation was undertaken (primarily at RMIT) to develop a decision support tool and a user friendly guide for use of fibre reinforced polymer composites in rehabilitation of concrete structures. The user guidelines presented in this report were developed after industry consultation and a comprehensive review of the state of the art technology. The scope of the guide was mainly developed based on outcomes of two workshops with Queensland Department of Main Roads (QDMR). The document covers material properties, recommended construction requirements, design philosophy, flexural, shear and torsional strengthening of beams and strengthening of columns. In developing this document, the guidelines published on FIB Bulletin 14 (2002), Task group 9.3, International Federation of Structural Concrete (FIB) and American Concrete Institute Committee 440 report (2002) were consulted in conjunction with provisions of the Austroads Bridge design code (1992) and Australian Concrete Structures code AS3600 (2002). In conclusion, the user guide presents design examples covering typical strengthening scenarios.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper compares and reviews the recommendations and contents of the guide for the design and construction of externally bonded FRP systems for strengthening concrete structures reported by ACI committee 440 and technical report of Externally bonded FRP reinforcement for RC structures (FIB 14) in application of carbon fiber reinforced polymer (CFRP) composites in strengthening of an aging reinforced concrete headstock. The paper also discusses the background, limitations, strengthening for flexure and shear, and other related issues in use of FRP for strengthening of a typical reinforced concrete headstock structure such as durability, de-bonding, strengthening limits, fire and environmental conditions. A case study of strengthening of a bridge headstock using FRP composites is presented as a worked example in order to illustrate and compare the differences between these two design guidelines when used in conjunction with the philosophy of the Austroads (1992) bridge design code.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Advanced composite materials offer remarkable potential in the strengthening of Civil Engineering structures. This research is targeted to provide in depth knowledge and understanding of bond characteristics of advanced and corrosion resistant material carbon fibre reinforced polymer (CFRP) that has a unique design tailor-ability and cost effective nature. The objective of this research is to investigate and compare the bonding mechanism between CFRP strengthened single and double strap steel joints. Investigations have been made in regards to failure mode, ultimate load and effective bond length for CFRP strengthened double and single strap joints. A series of tensile tests were conducted with different bond lengths for both type of joints. The bond behaviour of these specimens was further investigated by using nonlinear finite element analysis. Finally a bilinear relationship of shear stress-slip has been proposed by using the Finite element model for single and double strap joints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses the results of tests on the shear capacity of reinforced concrete columns strengthened with carbon fiber reinforced plastic (CFRP) sheet. The shear transfer mechanism of the specimens reinforced with CFRP sheet was studied. The factors affecting the shear capacity of reinforced concrete columns strengthened with CFRP sheet were analyzed. Several suggestions such as the number of layers, width and tensile strength of the CFRP sheet are proposed for this new strengthening technique. Finally, a simple and practical design method is presented in the paper. The calculated results of the suggested method are shown to be in good agreement with the test results. The suggested design method can be used in evaluating the shear capacity of reinforced concrete columns strengthened with CFRP sheet.