122 resultados para scintigraphy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Testicular tumors do not occur frequently. Primary treatment is surgical, and radiotherapy and chemotherapy can play important roles in cases of metastatic disease. Bone scintigraphy is used largely for early detection of skeletal metastases from several tumors, and conventional radiographic studies are less sensitive than the nuclear technique for such a purpose. The aim of this study was to identify the role of bone scintigraphy in cases of testicular tumors, regardless of the grade. Materials and Methods: The authors examined 28 patients (8 to 52 years old) with proved testicular tumors using Tc-99m MDP (750 MBq; 20 mCi) injected intravenously. Whole-body images were obtained 2 hours later, at 500,000 counts per image. Radiographic studies were obtained to investigate abnormal areas noted on scintigraphy. Results: The results of bone scintigraphy were abnormal in seven cases, consisting of variable but diffuse uptake in the iliac bone on the same side as the affected testicle. MDP uptake was substantial in five of these patients (four seminomas, one nonseminoma; only two radiographic studies were abnormal), and the two other patients had moderate uptake of the radiopharmaceutical (two seminomas; radiographic studies were normal). Metastases were confirmed by biopsy in three cases. Discussion: Early metastases from seminomas can occur through the lymphatic drainage toward the iliac lymph node chain. This could explain these findings. The scintigraphic aspects of the affected iliac bones seem characteristic. Conclusions: Early detection of metastases is very important to ensure the efficacy of radiotherapy and chemotherapy. Bone scintigraphy may play an important role in such cases and seems to be more sensitive than conventional radiography. Testicular tumor metastases should be considered when iliac involvement is observed. Paget's disease should be included in a differential diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The usefulness of stress myocardial perfusion scintigraphy for cardiovascular (CV) risk stratification in chronic kidney disease remains controversial. We tested the hypothesis that different clinical risk profiles influence the test. We assessed the prognostic value of myocardial scintigraphy in 892 consecutive renal transplant candidates classified into four risk groups: very high (aged epsilon 50 years, diabetes and CV disease), high (two factors), intermediate (one factor) and low (no factor). The incidence of CV events and death was 20 and 18, respectively (median follow-up 22 months). Altered stress testing was associated with an increased probability of cardiovascular events only in intermediate-risk (one risk factor) patients [30.3 versus 10, hazard ratio (HR) 2.37, confidence interval (CI) 1.693.33, P 0.0001]. Low-risk patients did well regardless of scan results. In patients with two or three risk factors, an altered stress test did not add to the already increased CV risk. Myocardial scintigraphy was related to overall mortality only in intermediate-risk patients (HR 2.8, CI 1.55.1, P 0.007). CV risk stratification based on myocardial stress testing is useful only in patients with just one risk factor. Screening may avoid unnecessary testing in 60 of patients, help stratifying for risk of events and provide an explanation for the inconsistent performance of myocardial scintigraphy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone scintigraphy is the standard procedure for the detection of bone metastases in breast cancer patients. FDG-PET/CT has been reported to be a sensitive tool for tumor staging in different malignant diseases. However, its accuracy for the detection of bone metastases has not been compared to bone scintigraphy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports an example of the application of pharmaceutical technology to wildlife management, specifically the design of an oral delivery system for the common brushtail possum in New Zealand. Designing an oral delivery system requires a knowledge of the time taken for particulates to reach target sites within the gastrointestinal tract (GIT). The transit time for fluid and indigestible particles of two different size ranges was determined in the common brushtail possum (Trichosurus vulpecula). Technetium-labelled (Tc-99m) anion exchange resin particles (75-125 or 500-700 mu m diameter) or solution (Tc-99m-labelled diethylenetriamine pentaacetic acid, Tc-99m-DTPA) was administered orally. At predetermined times after dosing (3, 6, 12, 24 or 32 h), the distribution of radioactivity throughout excised gastrointestinal tracts was determined by gamma scintigraphy. The transit profile was similar for the three formulations investigated. Unlike other closely related hindgut fermenting marsupials, there was no evidence to support the presence of a colonic separating mechanism in the common brushtail possum. Gastrointestinal transit was independent of body mass, gender and time of day that the dose is given. To target the hindgut for oral delivery of protein and peptide biocontrol agents, the formulation Would need to protect the bioactive for approximately 12 h prior to release. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cintigrafia óssea de corpo inteiro representa um dos exames imagiológicos mais frequentes realizados em medicina nuclear. Para além de outras aplicações, este procedimento é capaz de fornecer o diagnóstico de metástases ósseas. Em doentes oncológicos, a presença de metástases ósseas representa um forte indicador prognóstico da longevidade do doente. Para além disso, a presença ou ausência de metástases ósseas irá influenciar o planeamento do tratamento, requerendo para isso uma interpretação precisa dos resultados imagiológicos. Problema: Tendo em conta que a metastização óssea é considerada uma complicação severa relacionada com aumento da morbilidade e diminuição de sobrevivência dos doentes, o conceito de patient care torna-se ainda mais imperativo nestas situações. Assim, devem ser implementadas as melhores práticas imagiológicas de forma a obter o melhor resultado possível do procedimento efetuado, associado ao desconforto mínimo do doente. Uma técnica provável para atingir este objetivo no caso específico da cintigrafia óssea de corpo inteiro é a redução do tempo de aquisição, contudo, as imagens obtidas por si só teriam qualidade de tal forma reduzida que os resultados poderiam ser enviesados. Atualmente, surgiram novas técnicas, nomeadamente relativas a processamento de imagem, através das quais é possível gerar imagens cintigráficas com contagem reduzida de qualidade comparável àquela obtida com o protocolo considerado como standard. Ainda assim, alguns desses métodos continuam associados a algumas incertezas, particularmente no que respeita a sustentação da confiança diagnóstica após a modificação dos protocolos de rotina. Objetivos: O presente trabalho pretende avaliar a performance do algoritmo Pixon para processamento de imagem por meio de um estudo com fantoma. O objetivo será comparar a qualidade de imagem e a detetabilidade fornecidas por imagens não processadas com aquelas submetidas à referida técnica de processamento. Para além disso, pretende-se também avaliar o efeito deste algoritmo na redução do tempo de aquisição. De forma a atingir este objetivo, irá ser feita uma comparação entre as imagens obtidas com o protocolo standard e aquelas adquiridas usando protocolos mais rápidos, posteriormente submetidas ao método de processamento referido. Material e Métodos: Esta investigação for realizada no departamento de Radiologia e Medicina Nuclear do Radboud University Nijmegen Medical Centre, situado na Holanda. Foi utilizado um fantoma cilíndrico contendo um conjunto de seis esferas de diferentes tamanhos, adequado à técnica de imagem planar. O fantoma foi preparado com diferentes rácios de atividade entre as esferas e o background (4:1, 8:1, 17:1, 22:1, 32:1 e 71:1). Posteriormente, para cada teste experimental, o fantoma foi submetido a vários protocolos de aquisição de imagem, nomeadamente com diferentes velocidades de aquisição: 8 cm/min, 12 cm/min, 16 cm/min e 20 cm/min. Todas as imagens foram adquiridas na mesma câmara gama - e.cam Signature Dual Detector System (Siemens Medical Solutions USA, Inc.) - utilizando os mesmos parâmetros técnicos de aquisição, à exceção da velocidade. Foram adquiridas 24 imagens, todas elas submetidas a pós-processamento com recurso a um software da Siemens (Siemens Medical Solutions USA, Inc.) que inclui a ferramenta necessária ao processamento de imagens cintigráficas de corpo inteiro. Os parâmetros de reconstrução utilizados foram os mesmos para cada série de imagens, estando estabelecidos em modo automático. A análise da informação recolhida foi realizada com recurso a uma avaliação objetiva (utilizando parâmetros físicos de qualidade de imagem) e outra subjetiva (através de dois observadores). A análise estatística foi efetuada recorrendo ao software SPSS versão 22 para Windows. Resultados: Através da análise subjetiva de cada rácio de atividade foi demonstrado que, no geral, a detetabilidade das esferas aumentou após as imagens serem processadas. A concordância entre observadores para a distribuição desta análise foi substancial, tanto para imagens não processadas como imagens processadas. Foi igualmente demonstrado que os parâmetros físicos de qualidade de imagem progrediram depois de o algoritmo de processamento ter sido aplicado. Para além disso, observou-se ao comparar as imagens standard (adquiridas com 8 cm/min) e aquelas processadas e adquiridas com protocolos mais rápidos que: imagens adquiridas com uma velocidade de aquisição de 12 cm/min podem fornecer resultados melhorados, com parâmetros de qualidade de imagem e detetabilidade superiores; imagens adquiridas com uma velocidade de 16 cm/min fornecem resultados comparáveis aos standard, com valores aproximados de qualidade de imagem e detetabilidade; e imagens adquiridas com uma velocidade de 20 cm/min resultam em valores diminuídos de qualidade de imagem, bem como redução a nível da detetabilidade. Discussão: Os resultados obtidos foram igualmente estabelecidos por meio de um estudo clínico numa investigação independente, no mesmo departamento. Foram incluídos cinquenta e um doentes referidos com carcinomas da mama e da próstata, com o objetivo de estudar o impacto desta técnica na prática clínica. Os doentes foram, assim, submetidos ao protocolo standard e posteriormente a uma aquisição adicional com uma velocidade de aquisição de 16 cm/min. Depois de as imagens terem sido cegamente avaliadas por três médicos especialistas, concluiu-se que a qualidade de imagem bem como a detetabilidade entre imagens era comparável, corroborando os resultados desta investigação. Conclusão: Com o objetivo de reduzir o tempo de aquisição aplicando um algoritmo de processamento de imagem, foi demonstrado que o protocolo com 16 cm/min de velocidade de aquisição será o limite para o aumento dessa mesma velocidade. Após processar a informação, este protocolo fornece os resultados mais equivalentes àqueles obtidos com o protocolo standard. Tendo em conta que esta técnica foi estabelecida com sucesso na prática clínica, pode-se concluir que, pelo menos em doentes referidos com carcinomas da mama e da próstata, o tempo de aquisição pode ser reduzido para metade, duplicando a velocidade de aquisição de 8 para 16 cm/min.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Extrapulmonary small cell and small cell neuroendocrine tumors of unknown primary site are, in general, aggressive neoplasms with a short median survival. Like small cell lung cancer (SCLC), they often are responsive to chemotherapy and radiotherapy. Small cell lung cancer and well differentiated neuroendocrine carcinomas of the gastrointestinal tract and pancreas tend to express somatostatin receptors. These tumors may be localized in patients by scintigraphic imaging using radiolabeled somatostatin analogues. A patient with an anaplastic neuroendocrine small cell tumor arising on a background of multiple endocrine neoplasia type 1 syndrome is reported. The patient had a known large pancreatic gastrinoma and previously treated parathyroid adenopathy. At presentation, there was small cell cancer throughout the liver and skeleton. Imaging with a radiolabeled somatostatin analogue, 111In- pentetreotide (Mallinckrodt Medical B. V., Petten, Holland), revealed all sites of disease detected by routine biochemical and radiologic methods. After six cycles of chemotherapy with doxorubicin, cyclophosphamide, and etoposide, there was almost complete clearance of the metastatic disease. 111In-pentetreotide scintigraphy revealed uptake consistent with small areas of residual disease in the liver, the abdomen (in mesenteric lymph nodes), and posterior thorax (in a rib). The primary gastrinoma present before the onset of the anaplastic small cell cancer showed no evidence of response to the treatment. The patient remained well for 1 year and then relapsed with brain, lung, liver, and skeletal metastases. Despite an initial response to salvage radiotherapy and chemotherapy with carboplatin and dacarbazine, the patient died 6 months later.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental evidence suggests that somatostatin analogues may have a role to play in the management of lung tumours. We evaluated membrane preparations of nine small cell lung cancer (SCLC) cell lines and of tumour samples from 3 patients with non-small cell lung cancer (NSCLC), 1 patient with an atypical carcinoid and another with a bronchial carcinoid for the presence of specific binding sites for RC-160, a potent growth inhibitory octapeptide analogue of somatostatin. Specific binding was noted on six of nine SCLC lines. Radio-receptor assay on the cell line NCI H 69 showed evidence of two specific binding sites for RC-160, one with high affinity and the other with low affinity. Binding sites were also found on all five tumour samples. Scatchard analysis indicated the presence of a single class of receptors with high affinity in each case. Histological assessment of the resected specimens before binding assay showed them to be comprised of tumour cells and necrotic tissue, stroma and/or inflammatory cells. Therefore, the specific binding of RC-160 may be to tissues other than the tumour cells. In 3 patients, from whom the tumour samples were obtained, radiolabelled somatostatin analogue scintigraphy using [111In] pentetreotide was performed prior to surgery. In all cases, the radiolabel localised the disease. This study demonstrates the presence of specific binding sites for RC-160 in SCLC. Furthermore, the detection of specific binding in vitro and in vivo in NSCLC and intrapulmonary carcinoids demonstrates that these tumours contain cells which express specific binding sites for somatostatin. These results suggest that RC-160 may have a role toplay as a therapeutic agent in lung cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite developments in diagnosis and treatment, lung cancer is the commonest cause of cancer death in Europe and North America. Due to increasing cigarette consumption, the incidence of the disease and resultant mortality is rising dramatically in women. Novel approaches to the management of lung cancer are urgently required. Somatostatin is a tetradecapeptide first identified in the pituitary and subsequently throughout the body particularly in neuroendocrine cells of the pancreas and gastrointestinal tract and the nervous system. The peptide has numerous functions including inhibition of hormone release, immunomodulation and neurotransmission and is an endogenous inhibitor of cell proliferation and angiogenesis. Somatostatin and its analogs, including octreotide (SMS 201-995), somatuline (BIM 23014) and vapreotide (RC-160), act by binding to specific somatostatin receptors (SSTR) of which there are 5 principal subtypes, SSTR-1-5. Although elevated plasma somatostatin levels may be detected in 14-15% of patients, tumor cell expression appears rare. SSTR may be expressed by lung tumors, particularly small cell lung cancer and bronchial carcinoid disease. [111In]pentetreotide scintigraphy may have a role to play in the localization and staging of lung cancers both before and following treatment, and in detecting relapsed disease. The potential role of radiolabelled somatostatin analogs as radiotherapeutic agents in the management of lung cancer is currently being explored. Somatostatin analog therapy results in significant growth inhibition of both SSTR-positive and SSTR-negative lung tumors in vivo. Recent work indicates that these agents may enhance the efficacy of chemotherapeutic agents in the treatment of solid tumors including lung cancer. Copyright © 2001 S. Karger AG, Basel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gastric motility disorders, including delayed gastric emptying (gastroparesis), impaired postprandial fundic relaxation, and gastric myoelectrical disorders, can occur in type 1 diabetes, chronic renal failure, and functional dyspepsia (FD). Symptoms like upper abdominal pain, early satiation, bloating, nausea and vomiting may be related to gastroparesis. Diabetic gastroparesis is related to autonomic neuropathy. Scintigraphy is the gold standard in measuring gastric emptying, but it is expensive, requires specific equipment, and exposes patients to radiation. It also gives information about the intragastric distribution of the test meal. The 13C-octanoic acid breath test (OBT) is an alternative, indirect method of measuring gastric emptying with a stable isotope. Electrogastrography (EGG) registers the slow wave originating in the pacemaker area of the stomach and regulating the peristaltic contractions of the antrum. This study compares these three methods of measuring gastric motility in patients with type 1 diabetes, functional dyspepsia, and chronic renal failure. Currently no effective drugs for treating gastric motility disorders are available. We studied the effect of nizatidine on gastric emptying, because in preliminary studies this drug has proven to have a prokinetic effect due to its cholinergic properties. Of the type 1 patients, 26% had delayed gastric emptying of solids as measured by scintigraphy. Abnormal intragastric distribution of the test meal occurred in 37% of the patients, indicating impaired fundic relaxation. The autonomic neuropathy score correlated positively with the gastric emptying rate of solids (P = 0.006), but HbA1C, plasma glucose levels, or abdominal symptoms were unrelated to gastric emptying or intragastric distribution of the test meal. Gastric emptying of both solids and liquids was normal in all FD patients but abnormal intragastric distribution occurred in 38% of the patients. Nizatidine improved symptom scores and quality of life in FD patients, but not significantly. Instead of enhancing, nizatidine slowed gastric emptying in FD patients (P < 0.05). No significant difference appeared in the frequency of the gastric slow waves measured by EGG in the patients and controls. The correlation between gastric half-emptying times of solids measured by scintigraphy and OBT was poor both in type 1 diabetes and FD patients. According to this study, dynamic dual-tracer scintigraphy is more accurate than OBT or EGG in measuring gastric emptying of solids. Additionally it provides information about gastric emptying of liquids and the intragastric distribution of the ingested test meal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives:
We studied whether an increase in adenosine dose overcomes caffeine antagonism on adenosine-mediated coronary vasodilation.

Background:
Caffeine is a competitive antagonist at the adenosine receptors, but it is unclear whether caffeine in coffee alters the actions of exogenous adenosine, and whether the antagonism can be surmounted by increasing the adenosine dose.

Methods:
Myocardial perfusion scintigraphy (MPS) was used to assess adenosine-induced hyperemia in 30 patients before (baseline) and after coffee ingestion (caffeine). At baseline, patients received 140 µg/kg/min of adenosine combined with low-level exercise. For the caffeine study, 12 patients received 140 µg/kg/min of adenosine (standard) and 18 patients received 210 µg/kg/min (high dose) after caffeine intake (200 mg). Myocardial perfusion was assessed semiquantitatively and quantitatively, and perfusion defect was characterized according to the presence of reversibility.

Results:
Caffeine reduced the magnitude of perfusion abnormality induced by standard adenosine as measured by the summed difference score (SDS) (12.0 ± 4.4 at baseline vs. 4.1 ± 2.1 after caffeine, p < 0.001) as well as defect size (18% [3% to 38%] vs. 8% [0% to 22%], p < 0.01), whereas it had no effect on the abnormalities caused by high-dose adenosine (SDS, 7.7 ± 4.0 at baseline vs. 7.8 ± 4.2 after caffeine, p = 0.7). There was good agreement between baseline and caffeine studies for segmental defect category (kappa = 0.72, 95% confidence interval: 0.65 to 0.79) in the high-dose group. An increase in adenosine after caffeine intake was well tolerated.

Conclusions:
Caffeine in coffee attenuates adenosine-induced coronary hyperemia and, consequently, the detection of perfusion abnormality by adenosine MPS. This can be overcome by increasing the adenosine dose without compromising test tolerability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of a compact gamma camera with high spatial resolution is of great interest in Nuclear Medicine as a means to increase the sensitivity of scintigraphy exams and thus allow the early detection of small tumours. Following the introduction of the wavelength-shifting fibre (WSF) gamma camera by Soares et al. and evolution of photodiodes into highly sensitive silicon photomultipliers (SiPMs), this thesis explores the development of a WSF gamma camera using SiPMs to obtain the position information of scintillation events in a continuous CsI(Na) crystal. The design is highly flexible, allowing the coverage of different areas and the development of compact cameras, with very small dead areas at the edges. After initial studies which confirmed the feasibility of applying SiPMs, a prototype with 5 5 cm2 was assembled and tested at room temperature, in an active field-of-view of 10 10 mm2. Calibration and characterisation of intrinsic properties of this prototype were done using 57Co, while extrinsic measurements were performed using a high-resolution parallel-hole collimator and 99mTc. In addition, a small mouse injected with a radiopharmaceutical was imaged with the developed prototype. Results confirm the great potential of SiPMs when applied in a WSF gamma camera, achieving spatial resolution performance superior to the traditional Anger camera. Furthermore, performance can be improved by an optimisation of experimental conditions, in order to minimise and control the undesirable effects of thermal noise and non-uniformity of response of multiple SiPMs. The development and partial characterisation of a larger SiPM WSF gamma camera with 10 10 cm2 for clinical application are also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – A estimativa da função renal relativa (FRR) através de cintigrafia renal (CR) com ácido dimercaptossuccínico marcado com tecnécio-99 metaestável (99mTc-DMSA) pode ser influenciada pela profundidade renal (PR), atendendo ao efeito de atenuação por parte dos tecidos moles que envolvem os rins. Dado que raramente é conhecida esta mesma PR, diferentes métodos de correção de atenuação (CA) foram desenvolvidos, nomeadamente os que utilizam fórmulas empíricas, como os de Raynaud, de Taylor ou de Tonnesen, ou recorrendo à aplicação direta da média geométrica (MG). Objetivos – Identificar a influência dos diferentes métodos de CA na quantificação da função renal relativa através da CR com 99mTc-DMSA e avaliar a respetiva variabilidade dos resultados de PR. Metodologia – Trinta e um pacientes com indicação para realização de CR com 99mTc-DMSA foram submetidos ao mesmo protocolo de aquisição. O processamento foi efetuado por dois operadores independentes, três vezes por exame, variando para o mesmo processamento o método de determinação da FRR: Raynaud, Taylor, Tonnesen, MG ou sem correção de atenuação (SCA). Aplicou-se o teste de Friedman para o estudo da influência dos diferentes métodos de CA e a correlação de Pearson para a associação e significância dos valores de PR com as variáveis idade, peso e altura. Resultados – Da aplicação do teste de Friedman verificaram-se diferenças estatisticamente significativas entre os vários métodos (p=0,000), excetuando as comparações SCA/Raynaud, Tonnesen/MG e Taylor/MG (p=1,000) para ambos os rins. A correlação de Pearson demonstra que a variável peso apresenta uma correlação forte positiva com todos os métodos de cálculo da PR. Conclusões – O método de Taylor, entre os três métodos de cálculo de PR, é o que apresenta valores de FRR mais próximos da MG. A escolha do método de CA influencia significativamente os parâmetros quantitativos de FRR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Neuroendocrine neoplasms (NENs) are difficult to diagnose. We used SwissNET data to characterise NEN patients followed in the two academic centres of western Switzerland (WS), and to compare them with patients followed in eastern Switzerland (ES) as well as with international guidelines. METHOD: SwissNET is a prospective database covering data from 522 consecutive patients (285 men, 237 women) from WS (n = 99) and ES (n = 423). RESULTS: Mean ± SD age at diagnosis was 59.0 ± 15.7 years. Overall, 76/522 experienced a functional syndrome, with a median interval of 1.0 (IQR: 1.0-3.0) year between symptoms onset and diagnosis. A total of 51/522 of these tumours were incidental. The primary tumour site was the small intestine (29%), pancreas (21%), appendix (18%) and lung (11%) in both regions combined. In all, 513 functional imaging studies were obtained (139 in WS, 374 in ES). Of these, 381 were 111In-pentetreotide scintigraphies and 20 were 68Ga-DOTATOC PET. First line therapy was surgery in 87% of patients, medical therapy (biotherapy or chemotherapy) in 9% and irradiation in 3% for both regions together. CONCLUSION: Swiss NEN patients appear similar to what has been described in the literature. Imaging by somatostatin receptor scintigraphy (SRS) is widely used in both regions of Switzerland. In good accordance with published guidelines, data on first line therapy demonstrate the crucial role of surgery. The low incidence of biotherapy suggests that long-acting somatostatin analogues are not yet widely used for their anti-proliferative effects. The SwissNET initiative should help improve compliance with ENETS guidelines in the workup and care of NEN patients.