988 resultados para root canal length measurement
Resumo:
The aim of this study was to evaluate two root canal filling techniques used in teeth that had their apical foramen disrupted and compare the apical infiltration with an ideal clinical situation. Twenty-seven freshly extracted single-rooted teeth were selected and radiographed to confirm the existence of a single and straight root canal. The crowns were removed at a mean distance of 11 mm from the apex. The teeth had the root canals instrumented and were randomly assigned to 3 groups (n=9): ND group-root canals were filled using the lateral compaction technique and no disruption was performed; DRF group-the apical constriction was disrupted by advancing a #40 K-file 1 mm beyond the original working length, the canals were reinstrumented to create an apical ledge at 1 mm from the apical foramen and were obturated with a master gutta-percha cone with same size as the last file used for reinstrumentation; DF group - the teeth had the apical constriction disrupted and the canals were obturated with a master gutta-percha cone that fit at 1 mm from the apex. The teeth were submitted to dye leakage test with Rhodamine B for 7 days, using vaccum on the initial 5 min. The teeth were sectioned longitudinally and the leakage was measured in a linear fashion from apex to crown. There was no statistically significant difference (p>0.05) between the groups that had the apical foramen disrupted (DF, DRF), but significant difference was found between the disrupted groups and the non-disrupted one (p<0.01). In conclusion, none of the evaluated techniques was able to prevent apical infiltration, so working length so the working length determination has to be established and maintained carefully.
Resumo:
Introduction: An experimental mineral trioxide aggregate sealer (MTAS) has been developed for use as a root canal sealer. The aim of this study was to evaluate the setting time, pH, and calcium ion release of MTAS compared with white Portland cement (CPB-40; Votorantin Cimentos, Camargo Correa SA, Pedro Leopoldo, MG, Brazil), white MTA Angelus (MTA; Angelus, Londrina, PR, Brazil), and AH Plus (Dentsply DeTrey, Konstanz, Germany). Methods: For the evaluation of setting time, each material was analyzed using Gilmore-type needles. Polyethylene tubes with the materials were immersed in distilled water for the measurement of pH (digital pH meter) and calcium release (atomic absorption spectrophotometry). The evaluations were performed at 3, 6, 12, 24, and 48 hours and 7, 14, and 28 days. Data were analyzed by analysis of variance and the Tukey test at 5% significance level. Results: MTAS showed higher calcium release at all experimental periods, a greater increase in pH up to 48 hours and the longest setting time. Conclusions: MTAS presented favorable properties for its indication as a root canal sealer. (J Endod 2011;37:844-846)
Resumo:
Aim To evaluate differences between anatomic and radiographic measurements of root canal wall thickness (RCWT) after each root canal preparation stage during post placement.Methodology Twenty mandibular premolars with a single canal were decoronated and the roots embedded in resin using a teflon muffle. Roots were sectioned horizontally at a pre-established level and canals were prepared for post placement. Endodontic hand files were used for root canal preparation, followed by Gates Glidden drills and Peeso reamers. Standardized radiographs and photographs at pre-established measurement levels were taken before preparation, after root canal instrumentation, after Gates Glidden preparation and after Peeso enlargement. All images were digitized and RCWT at the mesial and distal walls measured (IMAGETOOL 3.0). Differences between radiographic and anatomic measurements were analysed with paired t-tests. ANOVA was used to compare the percentages of radiographic distortions.Results Regardless of the time-point evaluated, RCWT determined by radiographs were greater than the respective anatomic measurements (P < 0.05). The difference detected at each stage was similar and constant (P > 0.05).Conclusions Throughout preparation for post placement, radiographic images overestimated the RCWT by approximately 25%, regardless of the clinical stage evaluated.
Resumo:
Different types of laser have been widely studied for applicability in the oral health area. In the endodontic area, investigations with some types of laser have been conducted to establish safe parameters for clinical application in root canals. However, it has not been duly explained whether the temperature increase caused by laser irradiation could cause alteration in the temperature on the external surface of the root and, consequently, alterations in the cells of the periodontal ligament, causing resorption and even loss of the dental element. The proposal in this paper was to gauge the external root temperature in the apical and cervical regions of the roots of human teeth during root canal irradiation with Nd:yttrium aluminum garnet (YAG) and Er:YAG lasers using different parameters. The novel approach of this paper is the use of the technique of laser applications along the total length of the root canal with series of repetitive irradiation, however, using time of 1 s of irradiation associated with 1 s off to avoid cumulative thermal effects. Experimental results confirm the accuracy of the parameters and exposure regimen obtained. All the parameters used in this paper are acceptable from a clinical as well as a biological point of view. (C) 2009 Laser Institute of America.
Resumo:
The aim of the present study was to evaluate the in vivo antimicrobial activity of 2% chlorhexidine gluconate (FCFRP-USP) used as a root canal irrigating solution in teeth with pulp necrosis and radiographically visible chronic periapical reactions. Culture techniques and measurement of the inhibition zone were used. Twenty-two root canals of incisors and molars of 12 patients were used. After accessing the canal, the first root canal sample was collected with two sterile paper points that were transferred to a tube containing reduced transport fluid. The root canal was instrumented using chlorhexidine solution. A small sterile cotton pellet was placed at the root canal entrance, and the cavity was sealed with zinc oxide-eugenol cement. The canals were maintained empty for 48 h. Three sterile paper points were then introduced to absorb the root canal fluid (second sample). One paper point was placed on an agar plate inoculated with Micrococcus luteus ATCC 9341 and incubated for 24 h at 37°C, and the other two were submitted to microbiological evaluation. Present in 10 cases at baseline, mutans streptococci was reduced by 100% at the second assessment. Treatment showed an efficiency of 77.78% for anaerobic microorganisms at the second assessment. These data suggest that chlorhexidine prevents microbial activity in vivo with residual effects in the root canal system up to 48 h. Copyright © 1999 by The American Association of Endodontists.
Resumo:
Fifty-four extracted human mandibular molars were embedded and sectioned at two levels. The reassembled mesial root canals were prepared with stainless-steel hand K-files (Flexofiles) and either Nitiflex or Mity nickel-titanium hand K-files using a push-pull anticurvature filing technique. Each of the three experimental groups contained 36 mesial canals randomly distributed. Superimposed pre- and postinstrumentation cross-sectional root images were magnified using a stereomicroscope and transferred to a computer for measurement and statistical analysis. The direction and extent of canal center movement were evaluated. At the apical level, the groups produced no significant difference of direction of canal center movement. In cervical sections, all groups tended to move in a distolingual direction. The three groups, however, produced no significant difference in the cervical sections in the extent of canal center movement. In apical sections, Nitiflex produced the least canal center movement. Copyright © 1999 by The American Association of Endodontists.
Resumo:
Aim: Based on the hypothesis the application of a low-viscosity hydrophobic resin coating improves the bond of all-in-one adhesive, the purpose of the study was to evaluate the bond strength of four adhesive systems to bovine root dentin using the push-out test method. Methods and Materials: The root canals of 32 bovine roots (16 mm) were prepared to a length of 12 mm using a FRC Postec Plus preparation drill. The specimens were allocated into four groups according to the adhesive system used: (Group 1) All-in-one Xeno III; (Group 2) All-in-one Xeno III+ScotchBond Multi-Purpose Plus Adhesive; (Group 3) Simplified Etch & Rinse One Step Plus; and (Group 4) Multi-Bottle Etch & Rinse All-Bond 2. A fiber-reinforced composite retention post was reproduced using an additional silicon impression and fabricated with DuoLink resin cement. The root specimens were treated with the selected adhesive systems, and the resin posts were luted in the canals with DuoLink resin cement. Each root specimen was cross sectioned into four samples (±1.8 mm in thickness), and the post sections were pushed-out to determine the bond strength to dentin. Results: Group 2 (2.9±1.2) was statistically higher than Group 1 (1.1±0.5) and Group 3 (1.1±0.5). Groups 1 and 3 showed no statistically significant difference while Group 4 (2.0±0.7) presented similar values (p>0.05) to Groups 1, 2, and 3 [(one-way analysis of variance (ANOVA)] and Tukey test, α=0.05). Conclusion: The hypothesis was accepted since the application of the additional layer of a low-viscosity bonding resin improved the bond of the all-in-one adhesive. Further studies must be conducted to evaluate the long-term bond.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective: To evaluate the impact of the type of root canal preparation, intraradicular post and mechanical cycling on the fracture strength of roots. Material and Methods: Eighty human single rooted teeth were divided into 8 groups according to the instruments used for root canal preparation (manual or rotary instruments), the type of intraradicular post (fiber posts-FRC and cast post and core-CPC) and the use of mechanical cycling (MC) as follows: Manual and FRC; Manual, FRC and MC; Manual and CPC; Manual, CPC and MC; Rotary and FRC; Rotary, FRC and MC; Rotary and CPC; Rotary, CPC and MC. The filling was performed by lateral compactation. All root canals were prepared for a post with a 10 mm length, using the custom # 2 bur of the glass fiber post system. For mechanical cycling, the protocol was applied as follows: an angle of incidence of 45 degrees, 37 degrees C, 88 N, 4 Hz, 2 million pulses. All groups were submitted to fracture strength test in a 45 degrees device with 1 mm/min cross-head speed until failure occurred. Results: The 3-way ANOVA showed that the root canal preparation strategy (p<0.03) and post type (p<0.0001) affected the fracture strength results, while mechanical cycling (p=0.29) did not. Conclusion: The root canal preparation strategy only influenced the root fracture strength when restoring with a fiber post and mechanical cycling, so it does not seem to be an important factor in this scenario.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Aim The aim of the present study was to evaluate the effect of three different formulations of sodium hypochlorite on the microhardness of root canal dentin in cervical and apical segments. Methods Twenty-four extracted human teeth had their roots sectioned along their long axes in a buccolingual direction. One half of each root was selected, and transversely sectioned resulting in two segments, cervical and apical, with similar lengths. The specimens were divided into three groups (n = 16), according to the sodium hypochlorite formulation used: (a) group 1, 2.5% sodium hypochlorite; (b) group 2, Chlor-XTRA; and (c) group 3, 5.5% sodium hypochlorite gel. These groups were subdivided in two subgroups (n = 8): cervical and apical root segments. Before testing the substances, dentin microhardness was measured on each section, 100 μm from the root canal with a Knoop tester. After 15 min of application, a new measurement was performed on each segment. Data were collected and registered for statistical treatment. Results In both segments, the substances reduced dentin microhardness. No differences were observed between the groups, independent of the analyzed segment (P > 0.05). Conclusions All substances reduced dentin microhardness. Chlor-XTRA and 5.5% sodium hypochlorite gel promoted a reduction similar to the 2.5% sodium hypochlorite solution.
Resumo:
The aims of this study were to evaluate the effect of root canal filling techniques on root fracture resistance and to analyze, by finite element analysis (FEA), the expansion of the endodontic sealer in two different root canal techniques. Thirty single-rooted human teeth were instrumented with rotary files to a standardized working length of 14 mm. The specimens were embedded in acrylic resin using plastic cylinders as molds, and allocated into 3 groups (n=10): G(lateral) - lateral condensation; G(single-cone) - single cone; G(tagger) - Tagger's hybrid technique. The root canals were prepared to a length of 11 mm with the #3 preparation bur of a tapered glass fiber-reinforced composite post system. All roots received glass fiber posts, which were adhesively cemented and a composite resin core was built. All groups were subjected to a fracture strength test (1 mm/min, 45°). Data were analyzed statistically by one-way ANOVA with a significance level of 5%. FEA was performed using two models: one simulated lateral condensation and Tagger's hybrid technique, and the other one simulated the single-cone technique. The second model was designed with an amount of gutta-percha two times smaller and a sealer layer two times thicker than the first model. The results were analyzed using von Mises stress criteria. One-way ANOVA indicated that the root canal filling technique affected the fracture strength (p=0.004). The G(lateral) and G(tagger) produced similar fracture strength values, while G(single-cone) showed the lowest values. The FEA showed that the single-cone model generated higher stress in the root canal walls. Sealer thickness seems to influence the fracture strength of restored endodontically treated teeth.
Resumo:
Introduction: This study examined the anatomy of 4-rooted maxillary second molars by using micro computed tomography. Methods: Twenty-five 4-rooted maxillary second molars were scanned to evaluate the size and curvature of the roots; the distance and spatial configuration between some anatomical landmarks; the number of root canals and the position of apical foramina; the occurrence of fusion of roots and enamel pearls; the configuration of the canal at the apical third; the cross-sectional appearance, the volume, and surface area of the root canals. Data were compared by using analysis of variance post hoc Tukey test (alpha = 0.05). Results: The specimens were classified as types I (n = 16), II (n = 7), and III (n = 2). The size of the roots was similar (P > .05), and most of them presented straight with 1 canal, except the mesiobuccal that showed 2 canals in 24% of the samples. The configuration of the pulp chamber was mostly irregular quadrilateral-shaped. The lowest mean distance of the orifices was observed between the buccal roots (P < .05). Accessory canals were present mostly in the apical third. Location of the apical foramina varied considerably. Fusion of roots and enamel pearls occurred in 44% and 8% of the samples, respectively. Mean distance from the pulp chamber floor to the furcation was 2.15 +/- 0.57 mm. No statistical differences were found in the bi-dimensional and 3-dimensional analyses (P > .05). Conclusions: All analyzed parameters showed differences between roots, except for the length of the roots, the configuration of the canals at the apical third, cross-sectional appearance, volume, and surface area of the canals. (J Endod 2012;38:977-982)
Resumo:
The radiopacity of esthetic root canal posts may impair the assessment of their fit to the root canal when using radiographic images. This study determined in vitro the radiographic density of esthetic root canal posts using digital images. Thirty-six roots of human maxillary canines were assigned to six groups (N=6 per group): Reforpost (RP); Aestheti-Plus (AP); Reforpost MIX (RPM); D.T. Light Post (LP); Reforpost Radiopaque (RPR); and White Post DC (WP). Standardized digital images of the posts were obtained in different conditions: outside the root canal, inside the canal before and after cementation using luting material, and with a tissue simulator. Analysis of variance was used to compare the radiopacity mean values among the posts outside the root canal and among the posts under the other conditions, and the t unpaired test to compare the radiopacity between the posts and the dentin, and between the posts and the root canal space. There was no statistically significant difference in radiopacity between RP and RPM, and LP and WP. AP posts showed radiopacity values significantly lower than those for dentin. No statistically significant difference was found between posts (RP and AP) and the root canal space. A statistically significant difference was observed between the luted and non-luted posts; additionally, luted posts with and without tissue simulator showed no significant differences. Most of the cement-luted posts analyzed in this study were distinguishable from the density of adjacent dentin surfaces, allowing radiographic confirmation of the fit of the post in the canal. The success of using esthetic root canal posts depends mainly on the fit of the post within the canal.[1] The radiopacity of a post allows for radiographic imaging to be used to determine the fit, an important factor in a clinical perspective.
Resumo:
To evaluate the effectiveness of Reciproc for the removal of cultivable bacteria and endotoxins from root canals in comparison with multifile rotary systems. The root canals of forty human single-rooted mandibular pre-molars were contaminated with an Escherichia coli suspension for 21 days and randomly assigned to four groups according to the instrumentation system: GI - Reciproc (VDW); GII - Mtwo (VDW); GIII - ProTaper Universal (Dentsply Maillefer); and GIV -FKG Race(™) (FKG Dentaire) (n = 10 per group). Bacterial and endotoxin samples were taken with a sterile/apyrogenic paper point before (s1) and after instrumentation (s2). Culture techniques determined the colony-forming units (CFU) and the Limulus Amebocyte Lysate assay was used for endotoxin quantification. Results were submitted to paired t-test and anova. At s1, bacteria and endotoxins were recovered in 100% of the root canals investigated (40/40). After instrumentation, all systems were associated with a highly significant reduction of the bacterial load and endotoxin levels, respectively: GI - Reciproc (99.34% and 91.69%); GII - Mtwo (99.86% and 83.11%); GIII - ProTaper (99.93% and 78.56%) and GIV - FKG Race(™) (99.99% and 82.52%) (P < 0.001). No statistical difference were found amongst the instrumentation systems regarding bacteria and endotoxin removal (P > 0.01). The reciprocating single file, Reciproc, was as effective as the multifile rotary systems for the removal of bacteria and endotoxins from root canals.