992 resultados para remote-controlled disconnector


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Only recently, during the past five years, consumer electronics has been evolving rapidly. Many products have started to include “smart home” capabilities, enabling communication and interoperability of various smart devices. Even more devices and sensors can be remote controlled and monitored through cloud services. While the smart home systems have become very affordable to average consumer compared to the early solutions decades ago, there are still many issues and things that need to be fixed or improved upon: energy efficiency, connectivity with other devices and applications, security and privacy concerns, reliability, and response time. This paper focuses on designing Internet of Things (IoT) node and platform architectures that take these issues into account, notes other currently used solutions, and selects technologies in order to provide better solution. The node architecture aims for energy efficiency and modularity, while the platform architecture goals are in scalability, portability, maintainability, performance, and modularity. Moreover, the platform architecture attempts to improve user experience by providing higher reliability and lower response time compared to the alternative platforms. The architectures were developed iteratively using a development process involving research, planning, design, implementation, testing, and analysis. Additionally, they were documented using Kruchten’s 4+1 view model, which is used to describe the use cases and different views of the architectures. The node architecture consisted of energy efficient hardware, FC3180 microprocessor and CC2520 RF transceiver, modular operating system, Contiki, and a communication protocol, AllJoyn, used for providing better interoperability with other IoT devices and applications. The platform architecture provided reliable low response time control, monitoring, and initial setup capabilities by utilizing web technologies on various devices such as smart phones, tablets, and computers. Furthermore, an optional cloud service was provided in order to control devices and monitor sensors remotely by utilizing scalable high performance technologies in the backend enabling low response time and high reliability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The goal of the thesis "Conversion of a Micro, Glow-Ignition, Two-Stroke Engine from Nitromethane-Methanol Blend Fuel to Military Jet Propellant (JP-8)" was to demonstrate the ability to operate a small engine on JP-8 and was completed in two phases. The first phase included choosing, developing a test stand for, and baseline testing a nitromethane-methanol-fueled engine. The chosen engine was an 11.5 cc, glow-ignition, two-stroke engine designed for remote-controlled helicopters. A micro engine test stand was developed to load and motor the engine. Instrumentation specific to the low flow rates and high speeds of the micro engine was developed and used to document engine behavior. The second phase included converting the engine to operate on JP-8, completing JP-8-fueled steady-state testing, and comparing the performance of the JP-8-fueled engine to the nitromethane-methanol-fueled engine. The conversion was accomplished through a novel crankcase heating method; by heating the crankcase for an extended period of time, a flammable fuel-air mixture was generated in the crankcase scavenged engine, which greatly improved starting times. To aid in starting and steady-state operation, yttrium-zirconia impregnated resin (i.e. ceramic coating) was applied to the combustion surfaces. This also improved the starting times of the JP-8-fueled engine and ultimately allowed for a 34-second starting time. Finally, the steady-state data from both the nitromethane-methanol and JP-8-fueled micro engine were compared. The JP-8-fueled engine showed signs of increased engine friction while having higher indicated fuel conversion efficiency and a higher overall system efficiency. The minimal ability of JP-8 to cool the engine via evaporative effects, however, created the necessity of increased cooling air flow. The conclusion reached was that JP-8-fueled micro engines could be viable in application, but not without additional research being conducted on combustion phenomenon and cooling requirements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: Cardiopulmonary bypass is associated with ischemia-reperfusion injury to multiple organs. We aimed to evaluate whether remote ischemic preconditioning performed the day before surgery for congenital heart disease with cardiopulmonary bypass attenuates the postoperative inflammatory response and myocardial dysfunction. Methods: This was a prospective, randomized, single-blind, controlled trial. Children allocated to remote ischemic preconditioning underwent 4 periods of 5 minutes of lower limb ischemia by a blood pressure cuff intercalated with 5 minutes of reperfusion. Blood samples were collected 4, 12, 24, and 48 hours after cardiopulmonary bypass to evaluate nuclear factor kappa B activation in leukocytes by quantification of mRNA of I kappa B alpha by real-time quantitative polymerase chain reaction and for interleukin-8 and 10 plasma concentration measurements by enzyme-linked immunosorbent assay. Myocardial dysfunction was assessed by N-terminal pro-B-type natriuretic peptide and cardiac troponin I plasma concentrations, measured by chemiluminescence, and clinical parameters of low cardiac output syndrome. Results: Twelve children were allocated to remote ischemic preconditioning, and 10 children were allocated to the control group. Demographic data and Risk Adjustment for Congenital Heart Surgery 1 classification were comparable in both groups. Remote ischemic preconditioning group had lower postoperative values of N-terminal pro-B-type natriuretic peptide, but cardiac troponin I levels were not significantly different between groups. Interleukin-8 and 10 concentrations and I kappa B alpha gene expression were similar in both groups. Postoperative morbidity was similar in both groups; there were no postoperative deaths in either group. Conclusions: Late remote ischemic preconditioning did not provide clinically relevant cardioprotection to children undergoing cardiopulmonary bypass. (J Thorac Cardiovasc Surg 2012;144:178-83)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Supraceliac aortic clamping in major vascular procedures promotes splanchnic ischemia and reperfusion (I/R) injury that may induce endothelial dysfunction, widespread inflammation, multiorgan dysfunction, and death. We tested the hypothesis that local or remote ischemic preconditioning (IPC) may be protective against injury after supraceliac aortic clamping through the modulation of mesenteric leukocyte-endothelial interactions, as evaluated with intravital microscopy and expression of adhesion molecules. Methods: Fifty-six male Wistar rats (weight, 190 to 250 g), were divided into four groups of 14 rats each: control sham surgery without aortic occlusion; I/R through supraceliac aortic occlusion for 20 minutes, followed by 120 minutes of reperfusion; local IPC through supraceliac aortic occlusion for two cycles of 5 minutes of ischemia and 5 minutes of reperfusion, followed by the same protocol of the IR group; remote IPC through infrarenal aortic occlusion for two cycles of 10 minutes of ischemia and 10 minutes of reperfusion, followed by the same protocol of the IR group. Seven animals per group were used to evaluate in vivo leukocyte-endothelial interactions in postcapillary venules with intravital microscopy and another seven animals per group were used to collect mesentery samples for inmmnohistochemistry demonstration of adhesion molecules expression. Results: Supraceliac aortic occlusion increased the number of rolling leukocytes with slower velocities and increased the number of adherent leukocytes to the venular surface and leukocyte migration to the interstitium. The expression of P-selectin, E-selectin, and intercellular adhesion molecule-1 was also increased significantly after I/R. Local or remote IPC reduced the leukocyte recruitment in vivo and normalized the expression of adhesion molecules. Conclusions: Local or remote IPC reduces endothelial dysfunction on mesenteric microcirculation caused by I/R injury after supraceliac aortic clamping. (J Vase Surg 2010;52:1321-9.) Clinical Relevance: The present study demonstrates that ischemia and reperfusion injury induced by supraceliac aortic occlusion promotes endothelial dysfunction and leukocyte recruitment on mesenteric microcirculation. Local and remote preconditioning reduced leukocyte-endothelial interactions and normalized the expression of endothelial adhesion molecules involved in this process. Although we recognize the limitation of an experimental model, our findings suggest that local and remote ischemic preconditioning minimize the endothelial dysfunction and leukocyte recruitment events that play a central role in systemic inflammation and multiorgan dysfunction after major aortic reconstructions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Twenty-four parents of oppositional preschoolers were randomly assigned to either a self-directed behavioral family intervention condition (SD) or to a waitlist control group (WL). The self-directed parent training program based on self-regulation principles, consisted of a written information package and weekly telephone consultations for 10 weeks. At posttest, in comparison to the WL group, children in the SD group had lower levels of behavior problems on parent report measures of child behavior. At posttreatment, parents in the SD condition reported increased levels of parenting competence and lower levels of dysfunctional parenting practices as compared to parents in the WL condition. In addition, mothers reported lower levels of anxiety, depression, and stress as compared to mothers in the WL condition at posttreatment. Using mother's reports, gains in child behavior and parenting practices achieved at posttreatment were maintained at 4-month follow-up.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ventilation and cooling of deep, hot mines present particular problems in Australia as a consequence of the surface climate, the size of the underground voids, the degree of mechanization and the cost of power in remote areas. A preliminary investigation of the effects of controlled partial recirculation of air was conducted in Mount Isa Mines' Deep Copper section. Gas and dust concentrations were measured in the exhaust air of the major working section to assess the potential for recirculating exhaust air to the intake airways to reduce the cost of providing an acceptable working environment in the deep parts of the mine. Studies were undertaken of airborne dust deposition in vertical airways and the efficiency of usage of the ventilation air in diluting contaminants. It was established that 45% of the respirable dust was deposited in a 130-m vertical raise and 60% of the air supplied to the section could be reused or recirculated. The first major field trial of a controlled partial recirculation system in Australia was undertaken in the light of these results and demonstrated excellent potential for significant reduction in ventilation costs. Gas and dust contaminant levels were well below the threshold limit values during the trial. It is concluded that controlled partial recirculation can be a practical, effective and safe aid to normal ventilation practice in Australian deep, hot mines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fieldbus communication networks aim to interconnect sensors, actuators and controllers within process control applications. Therefore, they constitute the foundation upon which real-time distributed computer-controlled systems can be implemented. P-NET is a fieldbus communication standard, which uses a virtual token-passing medium-access-control mechanism. In this paper pre-run-time schedulability conditions for supporting real-time traffic with P-NET networks are established. Essentially, formulae to evaluate the upper bound of the end-to-end communication delay in P-NET messages are provided. Using this upper bound, a feasibility test is then provided to check the timing requirements for accessing remote process variables. This paper also shows how P-NET network segmentation can significantly reduce the end-to-end communication delays for messages with stringent timing requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Remote engineering (also known as online engineering) may be defined as a combination of control engineering and telematics. In this area, specific activities require computacional skills in order to develop projects where electrical devives are monitored and / or controlled, in an intercative way, through a distributed network (e.g. Intranet or Internet). In our specific case, we will be dealing with an industrial plant. Within the last few years, there has been an increase in the number of activities related to remote engineering, which may be connected to the phenomenon of the large extension experienced by the Internet (e.g. bandwith, number of users, development tools, etc.). This increase opens new and future possibilities to the implementation of advance teleworking (or e-working) positions. In this paper we present the architecture for a remote application, accessible through the Internet, able to monitor and control a roller hearth kiln, used in a ceramics industry for firing materials. The proposed architecture is based on a micro web server, whose main function is to monitor and control the firing process, by reading the data from a series of temperature sensors and by controlling a series of electronic valves and servo motors. This solution is also intended to be a low-cost alternative to other potential solutions. The temperature readings are obtained through K-type thermopairs and the gas flow is controlled through electrovalves. As the firing process should not be stopped before its complete end, the system is equipped with a safety device for that specific purpose. For better understanding the system to be automated and its operation we decided to develop a scale model (100:1) and experiment on it the devised solution, based on a Micro Web Server.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Commonly, when a weblab is developed to support remote experiments in sciences and engineering courses, a particular hardware/software architecture is implemented. However, the existence of several technological solutions to implement those architectures difficults the emergence of a standard, both at hardware and software levels. While particular solutions are adopted assuming that only qualified people may implement a weblab, the control of the physical space and the power consumption are often forgotten. Since controlling these two previous aspects may increase the quality of the weblab hosting the remote experiments, this paper proposes the useof a new layer implemented by a domotic system bus with several devices (e.g. lights, power sockets, temperature sensors, and others) able to be controlled through the Internet. We also provide a brief proof-of-concept in the form of a weblab equipped with a simple domotic system usually implemented in smart houses. The added value to the remote experiment hosted at the weblab is also identified in terms of power savings and environment conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electromagnetic scattering inverse problems, microwave imaging, reconstruction of dielectric media, remote sensing, tomography

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The indication for pulmonary artery banding is currently limited by several factors. Previous attempts have failed to produce adjustable pulmonary artery banding with reliable external regulation. An implantable, telemetrically controlled, battery-free device (FloWatch) developed by EndoArt SA, a medical company established in Lausanne, Switzerland, for externally adjustable pulmonary artery banding was evaluated on minipigs and proved to be effective for up to 6 months. The first human implant was performed on a girl with complete atrioventricular septal defect with unbalanced ventricles, large patent ductus arteriosus and pulmonary hypertension. At one month of age she underwent closure of the patent ductus arteriosus and FloWatch implantation around the pulmonary artery through conventional left thoracotomy. The surgical procedure was rapid and uneventful. During the entire postoperative period bedside adjustments (narrowing or release of pulmonary artery banding with echocardiographic assessment) were repeatedly required to maintain an adequate pressure gradient. The early clinical results demonstrated the clinical benefits of unlimited external telemetric adjustments. The next step will be a multi-centre clinical trial to confirm the early results and adapt therapeutic strategies to this promising technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Remote control systems are a very useful element to control and monitor devices quickly and easily. This paper proposes a new architecture for remote control of Android mobile devices, analyzing the different alternatives and seeking the optimal solution in each case. Although the area of remote control, in case of mobile devices, has been little explored, it may provide important advantages for testing software and hardware developments in several real devices. It can also allow an efficient management of various devices of different types, perform forensic security tasks, etc ... The main idea behind the proposed architecture was the design of a system to be used as a platform which provides the services needed to perform remote control of mobile devices. As a result of this research, a proof of concept was implemented. An Android application running a group of server programs on the device, connected to the network or USB interface, depending on availability. This servers can be controlled through a small client written in Java and runnable both on desktop and web systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present paper reports a bacteria autonomous controlled concentrator prototype with a user-friendly interface for bench-top applications. It is based on a micro-fluidic lab-on-a-chip and its associated custom instrumentation, which consists in a dielectrophoretic actuator, to pre-concentrate the sample, and an impedance analyser, to measure concentrated bacteria levels. The system is composed by a single micro-fluidic chamber with interdigitated electrodes and a instrumentation with custom electronics. The prototype is supported by a real-time platform connected to a remote computer, which automatically controls the system and displays impedance data used to monitor the status of bacteria accumulation on-chip. The system automates the whole concentrating operation. Performance has been studied for controlled volumes of Escherichia coli (E. coli) samples injected into the micro-fluidic chip at constant flow rate of 10 μL/min. A media conductivity correcting protocol has been developed, as the preliminary results showed distortion of the impedance analyser measurement produced by bacterial media conductivity variations through time. With the correcting protocol, the measured impedance values were related to the quantity of bacteria concentrated with a correlation of 0.988 and a coefficient of variation of 3.1%. Feasibility of E. coli on-chip automated concentration, using the miniaturized system, has been demonstrated. Furthermore, the impedance monitoring protocol had been adjusted and optimized, to handle changes in the electrical properties of the bacteria media over time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

G-Rex is light-weight Java middleware that allows scientific applications deployed on remote computer systems to be launched and controlled as if they are running on the user's own computer. G-Rex is particularly suited to ocean and climate modelling applications because output from the model is transferred back to the user while the run is in progress, which prevents the accumulation of large amounts of data on the remote cluster. The G-Rex server is a RESTful Web application that runs inside a servlet container on the remote system, and the client component is a Java command line program that can easily be incorporated into existing scientific work-flow scripts. The NEMO and POLCOMS ocean models have been deployed as G-Rex services in the NERC Cluster Grid, and G-Rex is the core grid middleware in the GCEP and GCOMS e-science projects.