869 resultados para remoção mecânica
Resumo:
In the petroleum industry, water is always present in the reservoir formation together with petroleum and natural gas and this fact provokes the production of water with petroleum, resulting in a great environmental impact. Several methods can be applied for treatment of oily waters, such as: gravitational vases, granulated media filtration systems, flotation process, centrifugation process and the use of hydrocyclones, which can also be used in a combined way. However, the flotation process has showed a great efficiency as compared with other methods, because these methods do not remove great part of the emulsified oil. In this work was investigated the use of surfactants derived from vegetable oils, OSS and OGS, as collectors, using the flotation process in a glass column with a porous plate filter in its base for the input of the gaseous steam. For this purpose, oil/water emulsions were prepared using mechanical stirring, with concentrations around 300 ppm. The air flow rate was set at 700 cm3/min and the porous plate filter used for the generation of the air bubbles has pore size varying from 16 to 40 Pm. The column operated at constant volume (1500mL). A new methodology has been developed to collect the samples, where, instead of collecting the water phase, it was collected the oil phase removed by the process in the top of the flotation column. It has been observed that it is necessary to find an optimum surfactant concentration to achieve enhanced removal efficiency. Being for OSS 1.275 mmol/L and for OGS 0.840 mmol/L, with removal efficiencies of 93% and 99%, respectively, using synthetic solutions. For the produced water, the removal in these concentrations was 75% for OSS and 65% for OGS. It is possible to remove oil from water in a flotation process using surfactants of high HLB, fact that is against the own definition of HLB (Hydrophile-Lipophile Balance). The interfacial tension is an important factor in the oil removal process using a flotation process, because it has direct interference in the coalescence of the oil drops. The spreading of the oil of the air bubble should be considered in the process, and for the optimum surfactant concentrations it reached a maximum value. The removal kinetics for the flotation process using surfactants in the optimum concentration has been adjusted according to a first order model, for synthetic water as for the produced water.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Reabilitação Oral - FOAR
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Contamination of groundwater by BTX has been featured in recent decades. This type of contamination is due to small and continuous leaks at gas stations, causing serious problems to public health and the environment. Based on these antecedents, the search for new alternatives for treating contaminated water is shown to be essential. Therefore, this study aimed to evaluate the efficiency of removal of BTX by adsorption processes employing commercial alumina (Al2O3) and alumina supported with iron (Fe/Al2O3) as adsorbents. It was prepared by a in a synthetic gasoline solution and distilled water to simulate an actual sample. Initially, the adsorbents were characterized by techniques XRD, TG / DTG, XRF, FTIR and SEM/EDS, several trials, where he was placed synthetic solution to react in the presence of Al2O3 and Fe/Al2O3 in a closed, mechanical stirring system were performed varying the catalyst concentration 2, 4 and 6 g.L-1 every 0, 10, 30 60, 90 and 120 min, aliquots were taken and brought to analysis by gas chromatography flame ionization with headspace extraction. The results indicated that the absorbent which has higher BTX removal capacity was the Fe/Al2O3 at a concentration of 6 g.L-1, pH = 4 and time of 90 minutes reaction, resulting in an efficiency, resulting in a 86,5% efficiency for benzene removal, for the 95,4% toluene, 90,8% for ɱ,ρ- xylene and 93.7% for the θ-xylenes. Subsequently, we performed a kinetic study of the reactions, the values of experimental adsorption capacity (qe) showed agreement with the values of the theoretical adsorption capacity (qc) to the pseudo-second-order model in the adsorption tests using 2 and 6 gL-1 of Al2O3 and assays using 2, 4 and 6 g.L-1 of Fe/Al2O3. A fact corroborated by the R2 values, thus indicating that the chemical interactions are present in the adsorption mechanisms of BTX.
Resumo:
A introdução na prática clínica da intervenção coronária percutânea veio revolucionar o diagnóstico e tratamento da doença arterial. Todavia, as técnicas utilizadas quer para obter acesso vascular bem como para assegurar o seu devido encerramento são várias. Vários foram os estudos conduzidos ao longo do tempo que visaram a análise da eficácia e segurança destes dispositivos de encerramento vascular após punção percutânea. Este trabalho espelha primordialmente uma revisão bibliográfica alusiva ao tema em questão, contudo, e de forma concomitante, aborda uma visão de experiência prática de índole profissional pessoal face ao globalmente experienciado pelos enfermeiros num contexto específico no serviço de UCIC do HFF. Esta realidade prática contém o contacto com métodos de encerramento vascular após realização de cateterismo cardíaco como, os dispositivos Femoseal®, Angioseal®, a compressão mecânica através de TR Band® no caso de abordagem arterial radial e Femostop®, assim como compressão manual no caso de abordagem arterial femoral, sendo estes dois últimos abordados neste trabalho. Método e Participantes: Com o fito de apropriar a experiência clinica da prática diária e evidenciá-la como matriz integrante na prestação de cuidados surgiu a necessidade de realizar este estudo formulando duas questões (Quantos anos tem de experiência no contexto de trabalho que exige o contacto/conhecimento/utilização de dispositivos de encerramento vascular após procedimento de cateterismo cardíaco percutâneo?; Qual o método/dispositivo de encerramento vascular após cateterismo cardíaco percutâneo por via femoral que para si é garante de maior segurança e eficiência face ao propósito que se presta?) Estas questões foram colocadas à respectiva equipa de Enfermagem, sendo que se obtiveram de um universo de 31 enfermeiros, respostas de uma amostra de 21 elementos. Conclusão: Este trabalho não permite uma generalização/padronização dos resultados, tanto que se remete para um serviço específico. Contudo, no nosso contexto permite concluir que ambas as técnicas de compressão, seja mecânica ou manual, são preferidas pela amostra, apesar de existir uma discreta prevalência da compressão manual. Esta última também se verifica quanto maior for a experiência do enfermeiro neste contexto. Podemos ainda concluir que os enfermeiros do sexo feminino tem preferência pela compressão mecânica e os enfermeiros do sexo masculino pela compressão manual.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2016.