900 resultados para reliability study
Resumo:
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.
Resumo:
Study Design. Reliability study. Objectives. To assess between-acquisition reliability of new multilevel trunk cross sections measurements, in order to define what is a real change when comparing 2 trunk surface acquisitions of a same patient, before and after surgery or throughout the clinical monitoring. Summary of Background Data. Several cross-sectional surface measurements have been proposed in the literature for noninvasive assessment of trunk deformity in patients with adolescent idiopathic scoliosis (AIS). However, only the maximum values along the trunk are evaluated and used for monitoring progression and assessing treatment outcome. Methods. Back surface rotation (BSR), trunk rotation (TR), and coronal and sagittal trunk deviation are computed on 300 cross sections of the trunk. Each set of 300 measures is represented as a single functional data, using a set of basis functions. To evaluate between-acquisition variability at all trunk levels, a test-retest reliability study is conducted on 35 patients with AIS. A functional correlation analysis is also carried out to evaluate any redundancy between the measurements. Results. Each set of 300 measures was successfully described using only 10 basis functions. The test-retest reliability of the functional measurements is good to very good all over the trunk, except above the shoulders level. The typical errors of measurement are between 1.20° and 2.2° for the rotational measures and between 2 and 6 mm for deviation measures. There is a very strong correlation between BSR and TR all over the trunk, a moderate correlation between coronal trunk deviation and both BSR and TR, and no correlation between sagittal trunk deviation and any other measurement. Conclusion. This novel representation of trunk surface measurements allows for a global assessment of trunk surface deformity. Multilevel trunk measurements provide a broader perspective of the trunk deformity and allow a reliable multilevel monitoring during clinical follow-up of patients with AIS and a reliable assessment of the esthetic outcome after surgery.
Resumo:
The purpose of this study was to apply and compare two time-domain analysis procedures in the determination of oxygen uptake (VO2) kinetics in response to a pseudorandom binary sequence (PRBS) exercise test. PRBS exercise tests have typically been analysed in the frequency domain. However, the complex interpretation of frequency responses may have limited the application of this procedure in both sporting and clinical contexts, where a single time measurement would facilitate subject comparison. The relative potential of both a mean response time (MRT) and a peak cross-correlation time (PCCT) was investigated. This study was divided into two parts: a test-retest reliability study (part A), in which 10 healthy male subjects completed two identical PRBS exercise tests, and a comparison of the VO2 kinetics of 12 elite endurance runners (ER) and 12 elite sprinters (SR; part B). In part A, 95% limits of agreement were calculated for comparison between MRT and PCCT. The results of part A showed no significant difference between test and retest as assessed by MRT [mean (SD) 42.2 (4.2) s and 43.8 (6.9) s] or by PCCT [21.8 (3.7) s and 22.7 (4.5) s]. Measurement error (%) was lower for MRT in comparison with PCCT (16% and 25%, respectively). In part B of the study, the VO2 kinetics of ER were significantly faster than those of SR, as assessed by MRT [33.4 (3.4) s and 39.9 (7.1) s, respectively; P<0.01] and PCCT [20.9 (3.8) s and 24.8 (4.5) s; P < 0.05]. It is possible that either analysis procedure could provide a single test measurement Of VO2 kinetics; however, the greater reliability of the MRT data suggests that this method has more potential for development in the assessment Of VO2 kinetics by PRBS exercise testing.
Resumo:
This master´s thesis presents a reliability study conducted among onshore oil fields in the Potiguar Basin (RN/CE) of Petrobras company, Brazil. The main study objective was to build a regression model to predict the risk of failures that impede production wells to function properly using the information of explanatory variables related to wells such as the elevation method, the amount of water produced in the well (BSW), the ratio gas-oil (RGO), the depth of the production bomb, the operational unit of the oil field, among others. The study was based on a retrospective sample of 603 oil columns from all that were functioning between 2000 and 2006. Statistical hypothesis tests under a Weibull regression model fitted to the failure data allowed the selection of some significant predictors in the set considered to explain the first failure time in the wells
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.
Resumo:
Impairment due to narcolepsy strongly limits job performance, but there are no standard criteria to assess disability in people with narcolepsy and a scale of disease severity is still lacking. We explored: 1. the interobserver reliability among Italian Medical Commissions making disability and handicap benefit decisions for people with narcolepsy, searching for correlations between the recognized disability degree and patients’ features; 2. the willingness to report patients to the driving licence authority; 3. possible sources of variance in judgement. Fifteen narcoleptic patients were examined by four Medical Commissions in simulated sessions. Raw agreement and interobserver reliability among Commissions were calculated for disability and handicap benefit decisions and for driving licence decisions. Levels of judgement differed on percentage of disability (p<0.001), severity of handicap (p=0.0007) and the need to inform the driving licence authority (p=0.032). Interobserver reliability ranged from Kappa = - 0.10 to Kappa = 0.35 for disability benefit decision and from Kappa = - 0.26 to Kappa = 0.36 for handicap benefit decision. The raw agreement on driving licence decision ranged from 73% to 100% (Kappa not calculable). Spearman’s correlation between percentages of disability and patients’ features showed correlations with age, daytime naps, sleepiness, cataplexy and quality of life. This first interobserver reliability study on social benefit decisions for narcolepsy shows the difficulty of reaching an agreement in this field, mainly due to variance in interpretation of the assessment criteria. The minimum set of indicators of disease severity correlating with patients’ self assessments encourages a disability classification of narcolepsy.
Resumo:
This project develops K(bin), a relatively simple, binomial based statistic for assessing interrater agreement in which expected agreement is calculated a priori from the number of raters involved in the study and number of categories on the rating tool. The statistic is logical in interpretation, easily calculated, stable for small sample sizes, and has application over a wide range of possible combinations from the simplest case of two raters using a binomial scale to multiple raters using a multiple level scale.^ Tables of expected agreement values and tables of critical values for K(bin) which include power to detect three levels of the population parameter K for n from 2 to 30 and observed agreement $\ge$.70 calculated at alpha =.05,.025, and.01 are included.^ An example is also included which describes the use of the tables for planning and evaluating an interrater reliability study using the statistic, K(bin). ^
Resumo:
El objetivo de este Proyecto Final de Carrera es la realización de un ensayo de fiabilidad de componentes electrónicos, más concretamente de diodos LED, con el fin de estudiar su comportamiento a lo largo del tiempo de vida. Debido a la larga duración de los LEDs, un ensayo de este tipo podría durar años, por lo que es necesario realizar un ensayo acelerado que acorte significativamente el tiempo del experimento, para ello, han de someterse a esfuerzos mayores que en condiciones normales de funcionamiento. En la actualidad, los LEDs son usados en infinidad de aplicaciones, debido a sus múltiples ventajas respecto a otros sistemas de iluminación o señalización convencionales. En numerosos casos se utilizan en el exterior, soportando cambios de temperaturas y de humedad elevados, de ahí, la importancia de realizar ensayos de fiabilidad, que muestren sus posibles causas de fallo, los efectos que producen estos fallos y los aspectos de diseño, fabricación y mantenimiento que puedan afectarles. Como consecuencia del envejecimiento de los LEDs, pueden mostrar una reducción en el flujo luminoso y un empeoramiento de las propiedades cromáticas. Los LEDs utilizados en este Proyecto son de AlInGaP, rojos, de alta luminosidad. Para acelerar el ensayo, se utilizará una cámara climática que simule unas condiciones ambientales determinadas, en concreto, 85º C y 85% HR. Además, se realiza una monitorización periódica, siendo necesaria la utilización de un sistema automático de medida diseñado en LabVIEW, el cual, de manera simultánea realizará medidas y gestionará la inyección de corriente a los LEDs mientras se encuentren en el interior de la cámara climática. Se fabrican dos placas con 4 tiras de LEDs para inyectar un nivel de corriente diferente en cada una y así poder comparar la degradación en función de este parámetro. Fuera de la cámara climática se van a medir las curvas características de tensióncorriente de cada LED a una temperatura ambiente constante, fijada por un módulo Peltier. También se realizarán medidas de potencia luminosa y de espectro de emisión. Se analizarán los resultados obtenidos de cada una de las medidas y se realizará un estudio de fiabilidad y del proceso de degradación sufrido por los LEDs. Este PFC se puede dividir en las siguientes fases de trabajo, siendo el ensayo la parte más larga en el tiempo: · Búsqueda de bibliografía, documentación y normas aplicables. · Familiarización con los equipos y software, estudiando el manejo y funcionamiento de la cámara climática temperatura-humedad y el software a aplicar (LabVIEW y software del espectrómetro). · Desarrollo del hardware y sistemas necesarios para la realización del ensayo. · Realización del ensayo. · Análisis de resultados. ABSTRACT. The objective of this end of degree project is conducting an essay reliability of electronic components, more concretely LEDs, in order to study their behavior throughout its lifespan. Due to the long duration of the LEDs, a essay of this type could last for years, so it is necessary to perform an accelerated essay which significantly shorten the time of the experiment, testing should be subjected to greater efforts than in normal operation. Today, LEDs are used in many applications due to its many advantages over other conventional lighting systems or signaling. In numerous cases are used on the outside, enduring high changes in temperature and humidity, hence the importance of reliability essays, showing the possible causes of failure, the effects produced by these failures and aspects of design, manufacturing and maintenance that may affect them. As a result of the ageing of the LEDs, they may show a reduction in light output and a worsening of the chromatic properties. The LEDs used in this project are AlInGaP, red and high brightness. To speed up the essay will be used a climatic chamber to simulate specific environmental conditions, specifically 85 ° C and 85 % RH. In addition, is pe rformed a periodic monitoring using an automatic measurement system designed in LabVIEW , which , simultaneously will performed measurements and will manage the injection current to the LEDs while are inside of the climatic chamber. 4 strips of LEDs are created to inject a different level of current in each, so can compare the degradation in terms of this parameter. Out of the climatic chamber are obtained the characteristic curves of voltage-current of each LED at a constant room temperature, set by a Peltier module. Also, measures light power and the emitted spectrum. The results of each of the measures and a reliability study and degradation suffered by the LEDs will be discussed. This PFC can be divided into the following steps, the essay being the longest part: • Search bibliography, documentation and standards. • Familiarization with equipment and software, studying the management and the operation of the temperature-humidity environmental chamber and applying software (LabVIEW applications and spectrometer software). • Development of hardware and systems necessary for the conduct of the essay. • Carrying out the essay. • Analysis of results.
Resumo:
A la hora del estudio de los fenómenos acústicos, es necesario el conocimiento de las características técnicas de los elementos utilizados. Un parte importante de ello son los micrófonos, sus características son esenciales para la obtención y comparación de los datos. Intentando describirlas, este trabajo quiere presentar un estudio detallado de una de las características que influyen en ellos, la característica de vida, especializándose en un tipo de micrófonos, los electret. La metodología seguida para el estudio de estos micrófonos se basa en la recopilación de información tras ensayos a diferentes temperaturas con el fin de caracterizarlos según las distintas distribuciones de vida existentes. En cuanto a los contenidos, se comienza explicando una base histórica de estos, origen, características generales y su evolución a lo largo de los años. Seguidamente se especifica una base teórica sobre distintas características que los afectan, antecedentes, y una explicación de las distintas distribuciones y formas del cálculo de vida. Posteriormente comienza la explicación del material utilizado, así como todas las características, para poder explicar la realización del estudio. Para ello: - Se han realizado tres ensayos a diferentes temperaturas, 140º, 125º y 110º dentro de una cámara térmica - Cada ensayo ha constado de diez micrófonos - El número de horas dentro de la cámara térmica ha variado dependiendo de la temperatura a la que se sometían los micrófonos en cada ensayo. - Tras cada hora se ha realizado una medida de cada uno de los micrófonos del nivel de presión sonora a la entrada, con el fin de ir comparándolos tras cada tiempo dentro de la cámara térmica. - Finalmente se ha realizado un estudio de fiabilidad con el que se ha obtenido el tiempo de vida. ABSTRACT. When the study of acoustic phenomena, the knowledge of technical characteristics for the different elements used is needed. An important part of this are the microphones, their characteristics are essential for obtaining and comparing data. Trying to describe it, this paper wants to present a detailed analysis of one of the characteristics that influence them, the characteristic of life, focusing in one type of microphones, the electret. The methodology for the study of these microphones is based on gathering information after some test at different temperatures in order to characterize them with different existing distributions of life. As for the contents, begins with a historical basis of them, origin, general characteristics and their evolution through the years. Afterward a theoretical background on different characteristics that affect them, history and an explanation of different distributions for calculating life forms. Then it begins with the explanation of the material used, as well as the features, in order to explain the study. For that: - There were three test at different temperatures, 140º, 125º and 110º in a thermal camera - Each test has consisted in ten microphones - The number of hours inside the thermal camera has varied depending on the subjected test which the microphones were - After each hour, it has been made a measurement of each microphone of their sound level pressure, in order to compare them after every hour inside the thermal camera - Finally, it has been made a reliability study to obtain their lifetime
Resumo:
Background and Purpose. A new method of dynamometry has been developed to measure the performance of the craniocervical (CC) flexor muscles by recording the torque that these muscles exert on the cranium around the CC junction. This report describes the method, the specifications of the instrument, and the preliminary reliability data. Subjects and Methods. For the reliability study, 20 subjects (12 subjects with a history of neck pain, 8 subjects without a history of neck pain) performed, on 2 occasions, maximal voluntary isometric contraction (MVIC) tests of CC flexion in 3 positions within the range of CC flexion and submaximal sustained tests (20% and 50% of MVIC) in the middle range of CC flexion (craniocervical neutral position). Reliability coefficients were calculated to establish the test-retest reliability of the measurements. Results. The method demonstrated good reliability over 2 sessions in the measurement of MVIC (intraclass correlation coefficient [ICC] =.79-.93, SEM=0.6-1.4 N-m) and in the measurement of steadiness (standard deviation of torque amplitude) of a sustained contraction at 20% of NMC (ICC=.74-.80, SEM=0.01 N-m), but not at 50% of MVIC (ICC=.07-.76, SEM=0.04-0.13 N-m). Discussion and Conclusion. The new dynamometry method appears to have potential clinical application in the measurement of craniocervical flexor muscle performance.
Resumo:
Objectives: To report the research and development of a new approach to Functional Capacity Evaluation, the Gibson Approach to Functional Capacity Evaluation (GAPP FCE) for chronic back pain clients. Methods: Four Studies, including pilot and feasibility testing, expert review, and preliminary interrater reliability examination, are described here. Participants included 7 healthy young adults and 19 rehabilitation clients with back pain who underwent assessment using the GAPP FCE. Thirteen therapists were trained in the approach and were silently observed administering the Functional Capacity Evalutions by at least 1 other trained therapists or the first investigator Or both. An expert review using 5 expert occupational therapists was also conducted. Results: Study 1, the pilot with healthy individuals, indicated that the GAPP FCE was a feasible approach with good utility. Study 2, a pilot using 2 trained therapists assessing 5 back pain clients, supported the clinical feasibility of the approach. The expert review in Study 3 found support for GAPP FCE. Study 4, a trial of the approach with 14 rehabilitation clients, found support for the interrater reliability of recommendations for return to work based on performance in the GAPP FCE. Discussion: The evidence thus far available supports the GAPP FCE as ail approach that provides a Sound method for evaluating the performance of the physical demands of work with clients with chronic back pain. The tool has been shown to have good face and content validity, to meet acceptable test standards, and to have reasonable interrater reliability. Further research is occurring to look at a larger interrater reliability study, to further examine content validity, and to examine predictive validity.
Resumo:
Macular pigment (MP) is the collective name for three carotenoids, lutein, zeaxanthin and meso-zeaxanthin, which are found at high concentrations in the central macula. The macular carotenoids, like all carotenoids, are entirely of dietary origin. The term ‘macular pigment optical density’ (MPOD) refers to the peak concentration of MP in the retina, which varies from one individual to the next and is measurable in vivo. On account of its blue-light-filtering and antioxidant properties, MP has become a subject of interest with respect to age-related macular degeneration (AMD), the hypothesis being that MP helps to protect against AMD; the higher the MPOD, the lower the risk for AMD. Recently, a new MPOD-measuring device, the MPS 9000 (MPS), entered the ophthalmic market. Using this device, the research described here aimed to contribute new information to the MP literature. A second MPOD instrument, the Macular Pigment Reflectometer, was also used at times, but a reliability study (included in the thesis) demonstrated that it was unsuitable for use on its own. First, a series of exploratory investigations were undertaken to maximize the accuracy and consistency of MPOD measurements taken with the MPS; a protocol was established that substantially improved repeatability. Subsequently, a series of MPOD-based studies were conducted on anisometropia, South Asian race, blue-light-filtering contact lenses, and dietary modification with kale. The principle findings were as follows: interocular MPOD differences were not attributable to interocular refractive error differences; young adults of South Asian origin had significant gender-related MPOD differences (males>females, p<0.01), and they also had significantly higher MPOD than Caucasians (p<0.0005); wearing blue-light-filtering contact lenses for eight months did not affect MPOD; and dietary modification with kale for 16 weeks did not increase MPOD. This body of research adds new insights to MP knowledge, which in turn may contribute to MP knowledge in the context of AMD.
Resumo:
To investigate the validity and reliability of surface electromyography (EMG) as a new non-invasive determinant of the metabolic response to incremental exercise in elite cyclists. The relation between EMG activity and other more conventional methods for analysing the aerobic-anaerobic transition such as blood lactate measurements (lactate threshold (LT) and onset of blood lactate accumulation (OBLA)) and ventilatory parameters (ventilatory thresholds 1 and 2 (VT1 and VT2)) was studied.Twenty eight elite road cyclists (age 24 (4) years; VO2MAX 69.9 (6.4) ml/kg/min; values mean (SD)) were selected as subjects. Each of them performed a ramp protocol (starting at 0 W, with increases of 5 W every 12 seconds) on a cycle ergometer (validity study). In addition, 15 of them performed the same test twice (reliability study). During the tests, data on gas exchange and blood lactate levels were collected to determine VT1, VT2, LT, and OBLA. The root mean squares of EMG signals (rms-EMG) were recorded from both the vastus lateralis and the rectus femoris at each intensity using surface electrodes. Results - A two threshold response was detected in the rms-EMG recordings from both muscles in 90% of subjects, with two breakpoints, EMG(T1) and EMG(T2), at around 60-70% and 80-90% of VO2MAX respectively. The results of the reliability study showed no significant differences (p > 0.05) between mean values of EMG(T1) and EMG(T2) obtained in both tests. Furthermore, no significant differences (p > 0.05) existed between mean values of EMG(T1), in the vastus lateralis and rectus femoris, and VT1 and LT (62.8 (14.5) and 69.0 (6.2) and 64.6 (6.4) and 68.7 (8.2)% of VO2MAX respectively), or between mean values of EMG(T2), in the vastus lateralis and rectus femoris, and VT2 and OBLA (86.9 (9.0) and 88.0 (6.2) and 84.6 (6.5) and 87.7 (6.4)% of VO2MAX respectively). Rms-EMG may be a useful complementary non-invasive method for analysing the aerobic-anaerobic transition (ventilatory and lactate thresholds) in elite cyclists.