971 resultados para rastreamento do ponto de máxima potência
Resumo:
Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.
Resumo:
A Estenose Pulmonar (EP) é uma doença cardíaca congénita (DCC) caracterizada por obstrução dinâmica ou fixa do trato de saída do ventrículo direito. A EP vem referida como sendo a terceira DCC mais diagnosticada no cão, havendo, no entanto estudos mais recentes classificam-na como a segunda mais comum ou até a primeira. A forma de EP mais comum é a valvular, provando-se ter uma base hereditária poligénica em beagles e pensando-se ter um caracter autossómico recessivo em golden retrievers. As raças mais afetadas pela EP são o bulldog inglês, bulldog francês, boxer, pitbull, schnautzer entre outras. A maioria dos indivíduos afetados por esta condição não apresenta sinais clínicos, sendo a maioria dos indivíduos com EP descobertos pela presença de um sopro e conseguinte investigação. Cerca de 35% dos cães com EP severa demonstram intolerância ao exercício, sincope ou ascite. O sopro detetado à auscultação é sistólico de ejeção crescendo-decrescendo com ponto de máxima intensidade na base esquerda radiando dorsalmente. A ecocardiografia é um método expedito na deteção e caracterização da gravidade da doença. O prognóstico depende da gravidade da lesão e se o individuo está ou não assintomático na altura da apresentação. Este trabalho teve como objetivo estudar a EP numa população canina exposta a ecocardiografia no Hospital Veterinário do Porto (HVP). Neste estudo fez-se uma análise retrospetiva das alterações cardiovasculares diagnosticadas a cães no serviço de ecocardiografia do HVP, entre Março de 2003 e Fevereiro de 2012. Foram sujeitos a ecocardiografia neste período 808 cães, 715 dos quais com alterações cardiovasculares, a prevalência de DCC’s foi de 13.8%. A EP foi a segunda DCC mais diagnosticada nesta população de animais (2.80%), surgindo em 20 dos 99 cães com DCCs (20.2%). A forma de EP mais diagnosticada foi a valvular. As raças Boxer, Terranova, Dogue argentino e Fila brasileiro apresentam um maior risco relativo de terem EP. Não se verificou a existência de uma relação estatística significativa entre o sexo e a EP, quer considerando a amostra completa, quer separando por raça. A instauração de programas e normas de rastreio de EP em reprodutores, em Portugal, permitirá diminuir a incidência da doença e ter uma verdadeira noção da prevalência desta doença na população canina.
Resumo:
No Brasil, a idéia original era de se utilizar o gás natural como substituto do óleo diesel para o uso na frota de veículos pesados nos centros urbanos. Esta idéia deu lugar a uma maior difusão do uso de gás natural na frota de veículos leves, em função de algumas dificuldades inerentes ao mercado do gás natural como substituto do óleo diesel, tais como a pequena diferença de preços entre o óleo diesel e o gás natural. Com a liberação do uso de gás natural para veículos a gasolina, a partir de 1992, e o crescimento de postos de abastecimento, tem-se notado um grande aumento de veículos convertidos, nas cidades onde o combustível encontra-se disponível, como Porto Alegre. Devido ao aumento de veículos convertidos, decidiu-se elaborar um trabalho que descreve os principais componentes dos “Kits” de conversão encontrados atualmente no mercado para os veículos equipados com carburador e injeção eletrônica, assim como procedimentos para a correta instalação destes componentes. Simultaneamente efetuou-se testes em veículos convertidos para o uso do gás natural, com a obtenção de curvas de potência as quais estabelecem um comparativo entre a utilização de gasolina e gás natural. Também foram feitas análises quanto a emissões de gases tóxicos dos veículos convertidos e a verificação do fator Lambda responsável pela máxima potência ao utilizar-se gás natural como combustível Sendo assim, tem-se como objetivos neste trabalho, a análise do desempenho de veículos adaptados para o uso do gás natural em relação a veículos alimentados com combustíveis líquidos, descrevendo detalhadamente os elementos necessários para a conversão de um veículo, procedimentos básicos para uma conversão eficiente e segura, e vários testes de veículos relacionando o uso do gás natural comparativamente ao uso de combustível líquido. O trabalho é concluído com a indicação dos “Kits” de conversão mais eficientes além da demonstração de algumas técnicas de regulagem baseadas nos resultados obtidos nos testes com os veículos convertidos, as quais visam a redução da perda demasiada de potência, a redução do consumo de combustível gás e a redução das emissões de gases tóxicos.
Resumo:
Este trabalho insere em seu conteúdo dois propósitos: o primeiro é o de apresentar uma microusina experimental, uma planta piloto de uma microcentral hidrelétrica automatizada, que foi montada para ser utilizada como laboratório de pesquisas do desempenho de máquinas assíncronas de até 5CV operando como geradores de energia elétrica. Para isso, apresentamos todos os equipamentos com as suas respectivas especificações, a descrição do funcionamento e documentos gerais do projeto. O segundo é fazer uma revisão do uso da máquina assíncrona, funcionando como gerador de energia elétrica ligada à rede de distribuição local. Estudamos e apresentamos algumas conclusões sobre o comportamento deste tipo de gerador, no contexto de uma microcentral hidrelétrica automatizada, em situações operacionais onde se pode contemplar máxima potência ou máximo fator de potência ou, então, máximo rendimento. Realizamos análises teóricas considerando o circuito equivalente do gerador instalado na microcentral; foram geradas curvas das grandezas envolvidas no processo de geração de energia elétrica, e estes resultados foram comparados com as medidas fornecidas pelas leituras dos instrumentos, enquanto a máquina no ambiente da microusina experimental, era submetida à situação de carga zero até a máxima. Com os resultados colhidos procuramos estabelecer uma relação entre a potência mecânica nominal de motores assíncronos com a potência ativa nominal deste tipo de máquina operando como gerador.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Low voltage solar panels increase the reliability of solar panels due to reduction of in series associations the configurations of photovoltaic cells. The low voltage generation requires DCDC converters devices with high efficiency, enabling raise and regulate the output voltage. This study analyzes the performance of a photovoltaic panel of Solarex, MSX model 77, configured to generate an open circuit voltage of 10.5 V, with load voltage of 8.5 V, with short circuit current of 9 A and a power of 77 W. The solar panel was assembled in the isolated photovoltaic system configuration, with and without energy storage as an interface with a DCDC converter, Booster topology. The converter was designed and fabricated using SMD (Surface Mounted Devices) technology IC (integrated circuit) that regulates its output voltage at 14.2 V, with an efficiency of 87% and providing the load a maximum power of 20.88 W. The system was installed and instrumented for measurement and acquisition of the following data: luminosities, average global radiation (data of INPE Instituto Nacional de Pesquisas Espaciais), solar panel and environment temperatures, solar panel and DC-DC converter output voltages, panel, inverter, and battery charge output currents. The photovoltaic system was initially tested in the laboratory (simulating its functioning in ideal conditions of operation) and then subjected to testing in real field conditions. The panel inclination angle was set at 5.5°, consistent with the latitude of Natal city. Factors such as climatic conditions (simultaneous variations of temperature, solar luminosities and ra diation on the panel), values of load resistance, lower limit of the maximum power required by the load (20.88 W) were predominant factors that panel does not operate with energy efficiency levels greater than 5 to 6%. The average converter efficiency designed in the field test reached 95%
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Neste estudo descreve-se as características da estrutura vertical de um episódio de Jatos de Baixos Níveis (JBN) ocorrido no litoral do Pará, utilizando-se para tal, dados das radiossondagens de Ajuruteua, Município de Bragança coletados durante o experimento DESMATA (Impacto do Desmatamento Junto ao Litoral Atlântico da Amazônia) realizado no período de 08 a 22 de abril de 2002. Dentre os casos detectados no período chuvoso, selecionou-se um que se manteve por 12 horas com velocidade média de 15m/s e que estava direcionado de Nordeste para Leste, no ponto de máxima velocidade. Os resultados observacionais indicaram que, este JBN localizado no litoral Paraense foi resultado da ação combinada de dois fatores: (1) oscilação inercial e (2) baroclinia superficial. Estes dois fatores combinados sustentaram este JBN com intensidades entre 10 e 13m/s durante o dia e entre 14 e 16m/s durante a noite, localizado a uma altitude média de 800m acima da superfície.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
This paper presents the application and use of a methodology based on fuzzy theory and simulates its use in intelligent control of a hybrid system for generating electricity, using solar energy, photovoltaic and wind. When using a fuzzy control system, it reached the point of maximum generation of energy, thus shifting all energy generated from the alternative sources-solar photovoltaic and wind, cargo and / or batteries when its use not immediately. The model uses three variables used for entry, which are: wind speed, solar radiation and loading the bank of batteries. For output variable has to choose which of the batteries of the battery bank is charged. For the simulations of this work is used MATLAB software. In this environment mathematical computational are analyzed and simulated all mathematical modeling, rules and other variables in the system described fuzzy. This model can be used in a system of control of hybrid systems for generating energy, providing the best use of energy sources, sun and wind, so we can extract the maximum energy possible these alternative sources without any prejudice to the environment.
Resumo:
Muito interesse tem sido focado no potencial biotecnológico das microalgas, principalmente devido à identificação de diversas substâncias sintetizadas por estes organismos, dentre elas a anidrase carbônica e as ficobiliproteínas. A anidrase carbônica é uma metaloenzima que catalisa a hidratação reversível do CO2 em bicarbonato com alta eficiência, sendo utilizada para captação de CO2 através de sistemas biológicos. A C-ficocianina e a aloficocianina, corantes naturais, são os dois principais componentes das ficobiliproteínas em cianobactérias e apresentam diversas aplicações dentro da indústria alimentícia, cosmética e farmacêutica. O objetivo principal desta tese foi avaliar a produção e a extração da anidrase carbônica e das ficobiliproteínas a partir de diferentes microalgas. Para isso, primeiramente foi realizado uma investigação da produção da anidrase carbônica pela microalga Dunaliella tertiolecta, onde foi estudada a extração da enzima e sua aplicação em sistemas de captura enzimática de CO2. Posteriormente foi avaliada a produção da enzima ao longo do cultivo de diferentes microalgas marinhas e dulcícolas (Dunaliella tertiolecta, Tetraselmis sueccica, Phaeodactylum tricornutum, Nannochloropsis oculata, Isochysis galbana, Chlorella vulgaris e Scenedesmus obliquus). A produção da enzima e de ficobiliproteínas, também, foi estudada para as cianobactérias Spirulina platensis LEB 52, Spirulina sp. LEB 18 e Synechococcus nidulans. Todos os cultivos foram acompanhados em termos de biomassa e pH. Por último, foi realizado um estudo de extração da enzima de P. tricornutum e extração conjunta da anidrase carbônica e de ficobiliproteínas da cianobactéria S. sp. LEB 18. Os cultivos foram realizados em frascos erlenmeyer contendo os meios Conway (marinhas), BG-11 (dulcícolas) e Zarrouk 20% (cianobactérias). Na avaliação da ruptura celular foram testadas as técnicas de maceração em gral e pistilo, agitação em vórtex com pérolas de vidro, sonicação com pérolas de vidro, homogeneizador ultrassônico, secagem, congelamento e descongelamento e a combinação de tratamentos. Maiores rendimentos de extração da enzima a partir da microalga D. tertiolecta foram obtidos utilizando tratamento ultrassônico, juntamente com baixas concentrações de biomassa úmida (0,1 e 0,2 g/L), e a mesma apresentou potencial para aplicação em processos de captação enzimática do CO2. Durante os cultivos, a microalga C. vulgaris se destacou como maior produtora da enzima anidrase carbônica, atingindo valores de atividade enzimática de 44,0 U/L. As cianobactérias apresentaram valores de atividade entre 41,6 e 45,9 U/L, sendo que a S. sp. LEB 18 foi a que apresentou maiores produções de C-ficocianina e aloficocianina no ponto de máxima atividade volumétrica, 65,9 e 82,2 µg/mL, respectivamente. A enzima extraída da biomassa de S. platensis LEB 52 catalisou a hidratação do CO2 que precipitou na forma de CaCO3. Maiores rendimentos de extração da enzima a partir das microalgas P. tricornutum e S. sp. LEB 18 foram obtidos utilizando homogeneizador ultrassônico, que foram 31,3 U/g e 25,5 U/g, respectivamente. A biomassa de S. sp. LEB 18, também apresentou potencial para a extração de ficobiliproteínas, obtendo- se altas concentrações de C-ficocianina (100,5 mg/g) e aloficocianina (69,9 mg/g). Através dos resultados obtidos, pode-se verificar a potencialidade das microalgas e das cianobactérias para produção da enzima anidrase carbônica e das ficobiliproteínas, biomoléculas de alto valor industrial. Este trabalho apresenta processos eficientes para a extração da enzima e de ficobiliproteínas tanto para escala laboratorial como industrial.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Os métodos de fluxo de carga por Newton-Raphson e fluxo de carga desacoplado rápido convencionais são considerados inadequados para a obtenção do ponto de máximo carregamento de sistemas de potência, devido à problemas de mal-condicionamento neste ponto crítico e na sua vizinhança. Neste ponto a matriz Jacobiana do método de Newton-Raphson torna-se singular e considera-se que não são mais válidas as hipóteses de desacoplamento P-V e Q-teta utilizadas para a formulação do método fluxo de carga desacoplado rápido. No entanto, mostra-se neste trabalho, que com pequenas modificações, as versões XB e BX do fluxo de carga desacoplado rápido tornam-se adequadas para a obtenção do ponto de máximo carregamento. Estas novas versões modificadas são comparadas entre si com o intuito de explicitar suas características, assim como da influência da atuação dos limites de geração de potência reativa e de tap's de transformadores. Os resultados obtidos para os sistemas testes do IEEE (14, 30, 57 e 118 barras) mostram que as características de convergência das versões originais são preservadas. Além disso, durante o traçado das curvas PV, os diversos métodos podem ser comutados entre si possibilitando o cálculo de todos os pontos da curva com um número reduzido de iterações.